1.
Laser-induced fluorescence of pheophorbide a (Ph- a ) was used for in vitro photodynamic imaging (PDI) of a rat pancreatic acinar tumor. A 400 nm excitation induced a 470 nm autofluorescence and a 678 nm dye fluorescence in tumors and their surrounding pancreas 24 h after a 9 mg kg−1 body weight Ph- a intravenous administration. With lower intensities in these blood-rich tumors than in pancreas, Ph- a fluorescence signals are unable to provide tumor images. A dimensionless function (the ratio of Ph- a fluorescence by autofluorescence, called Rt for the tumor and Rp for the pancreas) was used for fluorescence contrast calculation (C = Rt/Rp) between six tumors and their paired pancreas. Among five available laser excitation wavelengths, only the 355 nm excitation gave a distinctive contrast (C = 1.5). The PDI of six intrapancreatic tumors and their intraperitoneal metastasis and of two control normal pancreas was thus performed ex vivo using a 355 nm excitation source delivered by a tripled Nd: YAG laser and a charged-coupled device camera. Fluorescence images were recorded at 680 nm (dye), 640 nm (background) and 470 nm (autofluorescence) through three corresponding 10 nm width bandpass filters. Computed division for each pixel of Ph- a fluorescence values by autofluorescence generated false color image. In this way, contrasted tumor images were obtained. But in five out of six animals false-positive images were present due to an autofluorescence decrease in some normal pancreatic areas. A 470 nm autofluorescence imaging on the same tumors gave in all cases false-positive image and false-negative in half of the cases. These observations suggest that autofluorescence alone is unable to achieve accurate PDI of pancreatic carcinoma and that using Ph- a as a PDI dye needs strong improvements.  相似文献   

2.
In the present study, we investigated remote laser-induced fluorescence (LIF), at a distance of 4.8 m, of a variety of natural minerals and rocks, and Hawaiian Ti (Cordyline terminalis) plant leaves. These minerals included calcite cleavage, calcite onex and calcite travertine, gypsum, fluorapatite, Dover flint and chalk, chalcedony and nephelene syenite, and rubies containing rock. Pulsed laser excitation of the samples at 355 and 266 nm often resulted in strong fluorescence. The LIF bands in the violet-blue region at approximately 413 and approximately 437 nm were observed only in the spectrum of calcite cleavage. The green LIF bands with band maxima in the narrow range of approximately 501-504 nm were observed in the spectra of all the minerals with the exception of the nephelene syenite and ruby rocks. The LIF red bands were observed in the range approximately 685-711 nm in all samples. Excitation with 532 nm wavelength laser gave broad but relatively low fluorescence background in the low-frequency region of the Raman spectra of these minerals. One microsecond signal gating was effective in removing nearly all background fluorescence (with peak at approximately 610 nm) from calcite cleavage Raman spectra, indicating that the fluorescence was probably from long-lifetime inorganic phosphorescence.  相似文献   

3.
Abstract Benzoporphyrin derivative monoacid ring A (BPD-MA) is a chlorin-like photosensitizer currently in clinical trials for cancer and psoriasis. It has maximal absorption peaks at both 630 and 690 nm and can be activated at both these wavelengths. In vitro phototoxicity tests using the P8 15 murine mastocytoma cell lines conducted over wavelengths of light between 678 and 700 nm emitted by an argon-ion pumped dye laser showed that equivalent cell kill could be achieved between 682 and 690 nm. Tests on in vivo phototoxicity of normal skin of DBN2 mice injected with 2 mg/kg of BPD-MA and exposed to light at 125 J/cm2, between 620 and 700 nm, demonstrated peaks of normal skin damage occurring at 630–640 nm and 680–690 nm. In tests carried out with light between 620 and 700 nm, at 10 nm increments, it was seen that light delivered at 680–690 nm caused slightly more damage to normal skin than light delivered at 630–640 nm. When lower doses of light between 675 and 705 nm were tested using smaller increments, it was determined that equivalent skin damage occurred over a range of 68–95 nm. Antitumor efficacy in tumor-bearing DBN2 mice was tested between 683 and 695 nm. It was found that equivalent antitumor efficacy, determined by assessing tumor-free status at 20 days posttreatment, occurred at wavelengths between 685 and 693 nm. When tumor-bearing animals injected with BPD-MA at 2 mdkg and exposed to light 3 h later were treated with either 630 or 690 nm light at various doses, it was observed that 690 nm light was more effective at tumor ablation than was 630 nm light, demonstrating that while similar damage to normal skin may be effected by equivalent doses of light at either wavelength, tumor ablation was greater at 690 nm. Further, our data suggest that alternative light sources with bandwidths greater than those of the argon-ion pumped dye laser (±0.3 nm) may have equivalent efficacy with this photosensitizer.  相似文献   

4.
The differentiation of proteins commonly found as binding media in paintings is presented based on spectrally resolved and time-resolved laser-induced fluorescence (LIF) and total emission spectroscopy. Proteins from eggs and animal glue were analysed with pulsed laser excitation at 248 nm (KrF excimer) and 355 nm (third harmonic of Nd:YAG) for spectrally resolved measurements, and at 337 nm (N2) and 405 nm (N2 pumped dye laser) for spectrally resolved lifetime measurements and fluorescence lifetime imaging (FLIM). Total emission spectra of binding media are used for the interpretation of LIF spectra. Time-resolved techniques become decisive with excitation at longer wavelengths as fluorescence lifetime permits the discrimination amongst binding media, despite minimal spectral differences; spectrally resolved measurements of fluorescence lifetime have maximum differences between the binding media examined using excitation at 337 nm, with maximum observed fluorescence at 410 nm. FLIM, which measures the average lifetime of the emissions detected, can also differentiate between media, is non-invasive and is potentially advantageous for the analysis of paintings. Figure The fluorescence of solid ox glue extracted from collagen can be visualised in this Total Fluorescence Spectrum; three different peaks from multiple fluorophores are present and allow the discrimination between collagen- and non-collagen proteinaceous binding media found in paintings  相似文献   

5.
Clinical interest in laser-induced fluorescence (LIF) spectroscopy and photodynamic therapy (PDT) is growing rapidly and may ultimately lead to close parallel use of these techniques. However, variations in LIF due to photosensitizer retention as well as tissue damage and healing processes may interfere with autofluorescence-based diagnostic methods. We have investigated the compatibility of these two techniques by quantifying PDT-induced changes in LIF in the human esophagus. Fluorescence spectra were collected endoscopically at excitation wavelengths (lambda ex) of 337, 400 and 410 nm in 32 patients. Measurements were performed immediately before and after PDT treatment with porfimer sodium and during follow-up procedures. In the months following PDT regions of reepithelialized squamous showed reduced autofluorescence in comparison with untreated squamous regions (P = 0.0007). Photosensitizer fluorescence was undetectable with lambda ex = 337 nm during follow-up procedures, whereas for lambda ex = 400 and 410 nm porfimer sodium fluorescence was noted for nearly a year after treatment. Therefore, residual photosensitizer fluorescence is likely to affect certain LIF-based diagnostic techniques during a period when patients are at high risk for tumor recurrence. Modification of LIF systems and/or the use of alternative photosensitizers may be required to optimize the detection of lesions in the post-PDT patient. Given the potential of LIF as a method for surveillance following cancer therapy, further investigation of the compatibility of specific LIF approaches with cancer pharmaceuticals may be warranted.  相似文献   

6.
Little is known about the photoreceptors involved in the photoperiodism of unicellular organisms, which we elucidated by deriving their action spectra. The flagellated alga Euglena gracilis exhibits photoperiodism, with a long-day response in cell reproduction. The underlying clock is a circadian rhythm with photoinductive capability, peaking at subjective dusk and occurring at the 26th hour in continuous darkness (DD) when transferred from continuous light (LL); it regulates photoinduction, a high-irradiance response (HIR), of a dark-capability of progressing through cell division. We derived the action spectra by irradiating E. gracilis with monochromatic light for 3h at around the 26th hour; the action maxima occurred at 380, 450-460, 480, 610, 640, 660, 680, and 740nm. Except for the maximum at 450-460nm, which was always a major maximum, the maxima greatly depended on the red (R)/far-red (FR) ratio of the prior LL. The high R/FR ratio resulted in a dominant major peak at 640nm and minor peaks at 480 and 680nm, whereas the low ratio resulted in dominant major peaks at 610 and 740nm and minor peaks at 380 and 660nm; the critical fluence was minimally about 60mmolm(-2). These HIRs resulted from the accumulation of corresponding low-fluence responses (LFRs) because we found that repetition of a 3-min light/dark cycle, with critical fluences of 1mmolm(-2), lasting for 3h resulted in the same photoinduction as the continuous 3-h irradiation. Moreover, these LFRs expressed photoreversibility. Thus, photoperiodic photoinduction involves Euglena-phytochrome (640 and 740nm) and blue photoreceptor (460nm). Although 380, 480, 610, 660, and 680nm may also represent Euglena-phytochrome, a definite conclusion awaits further study.  相似文献   

7.
Spectrally resolved fluorescence imaging of human colonic adenomas   总被引:2,自引:0,他引:2  
Native fluorescence (autofluorescence) of human tissues can be a valuable source of diagnostic information for detecting premalignant and malignant lesions in the human body. Digital imaging of autofluorescence may be useful for localization of such lesions during endoscopic examinations. Tissue fluorescence of 31 adenomatous polyps obtained from 16 patients has been excited in vitro using the 325 nm line of a He-Cd laser. Digital images of the autofluorescence are recorded in six spectral bands. This study provides new data about the spatial distributions of autofluorescence intensities emitted in different spectral bands by colonic adenomatous lesions and normal colonic mucosa. Areas characterized by autofluorescence intensity lower than in normal mucosa are found for a majority of the polyps under study. The observed patterns of spatial distribution differ for the different spectral bands and for different polypoid lesions. No inverse correlation is found between the emission intensity and the thickness of colonic mucosa. The results indicate the spectral bands most useful for diagnostic applications and demonstrate the complexity of the optical processes involved in shaping both the spectra and intensities of the autofluorescence.  相似文献   

8.
Dihydroxyacetone (DHA) has been proposed as a potential alternative to dansyl chloride for use as a fluorescence marker on skin to assess stratum corneum turnover time in vivo. However, the fluorescence from DHA on skin has not been adequately studied. To address this void, a noninvasive, noncontact spectral imaging system is used to characterize the fluorescence spectrum of DHA on skin in vivo and to determine the optimal wavelengths over which to collect the DHA signal that minimizes the contributions from skin autofluorescence. The DHA-skin fluorescence signal dominates the 580-680 nm region of the visible spectrum when excited with ultraviolet radiation in the 320-400 nm wavelength region (UVA). An explanation of the time-dependent spectral features is proposed in terms of DHA polymerization and binding to skin.  相似文献   

9.
We demonstrate the fabrication and characterization of a novel, inexpensive microchip capable of laser induced fluorescence (LIF) detection using integrated waveguides with built-in optical filters. Integrated wavelength-selective optical waveguides are fabricated by doping poly(dimethysiloxane) (PDMS) with dye molecules. Liquid-core waveguides are created within dye-doped PDMS microfluidic chips by filling channels with high refractive index liquids. Dye molecules are allowed to diffuse into the liquid core from the surrounding dye-doped PDMS. The amount of diffusion is controlled by choosing either polar (low diffusion) or apolar (high diffusion) liquid waveguide cores. The doping dye is chosen to absorb excitation light and to transmit fluorescence emitted by the sample under test. After 24 h, apolar waveguides demonstrate propagation losses of 120 dB cm(-1) (532 nm) and 4.4 dB cm(-1) (633 nm) while polar waveguides experience losses of 8.2 dB cm(-1) (532 nm) and 1.1 dB cm(-1) (633 nm) where 532 and 633 nm light represent the excitation and fluorescence wavelengths, respectively. We demonstrate the separation and detection of end-labelled DNA fragments using polar waveguides for excitation light delivery and apolar waveguides for fluorescence collection. We demonstrate that the dye-doped waveguides can provide performance comparable to a commercial dielectric filter; however, for the present choice of dye, their ultimate performance is limited by autofluorescence from the dye. Through the detection of a BK virus polymerase chain reaction (PCR) product, we demonstrate that the dye-doped PDMS system is an order of magnitude more sensitive than a similar undoped system (SNR: 138 vs. 9) without the use of any external optical filters at the detector.  相似文献   

10.
Sample autofluorescence (fluorescence of inherent components of tissue and fixative-induced fluorescence) is a significant problem in direct imaging of molecular processes in biological samples. A large variety of naturally occurring fluorescent components in tissue results in broad emission that overlaps the emission of typical fluorescent dyes used for tissue labeling. In addition, autofluorescence is characterized by complex fluorescence intensity decay composed of multiple components whose lifetimes range from sub-nanoseconds to a few nanoseconds. For these reasons, the real fluorescence signal of the probe is difficult to separate from the unwanted autofluorescence. Here we present a method for reducing the autofluorescence problem by utilizing an azadioxatriangulenium (ADOTA) dye with a fluorescence lifetime of approximately 15 ns, much longer than those of most of the components of autofluorescence. A probe with such a long lifetime enables us to use time-gated intensity imaging to separate the signal of the targeting dye from the autofluorescence. We have shown experimentally that by discarding photons detected within the first 20 ns of the excitation pulse, the signal-to-background ratio is improved fivefold. This time-gating eliminates over 96 % of autofluorescence. Analysis using a variable time-gate may enable quantitative determination of the bound probe without the contributions from the background.  相似文献   

11.
Time-resolved reflectance spectroscopy was performed on tumor-bearing mice, administered with disulphonated aluminum phthalocyanine (AlS(2)Pc, 5 mg/kg body weight), before, during and after photodynamic therapy. This allowed us to evaluate the absorption spectrum of AlS(2)Pc in vivo from 610 to 700 nm, and to investigate how the therapeutic irradiation affects it. Two tumor locations (intraderma on the back and intramuscular in the leg), and two uptake times (3 and 12 h) were considered. As already observed previously, the absorption spectrum of AlS(2)Pc in vivo is centered at 680-685 nm. The irradiation causes a blue-shift of the measured line shape, more or less marked depending on the experimental conditions. A reduction in absorption is also often observed upon illumination with therapeutic light doses.  相似文献   

12.
Calcium Ruby m-Cl (X = H, Y = Cl) is a visible-light excited red-emitting calcium concentration ([Ca2+]) indicator dye (579/598 nm peak excitation/emission) with a side arm for conjugation via EDC or click chemistry. Its large molar extinction and high quantum yield rank it among the brightest long-wavelength Ca2+ indicators. Calcium Ruby is a promising alternative to existing dyes for imaging [Ca2+] in multicolor fluorescence applications or in the presence of yellow-green cellular autofluorescence.  相似文献   

13.
The combination of remote/standoff sensing and laser-induced fluorescence (LIF) spectroscopy shows potential for detection of uranyl (UO2(2+)) compounds. Uranyl compounds exhibit characteristic emission in the 450-600 nm (22,200 to 16,700 cm(-1)) spectral region when excited by wavelengths in the ultraviolet or in the short-wavelength portion of the visible spectrum. We report a parametric study of the effects of excitation wavelength [including 532 nm (18,797 cm(-1)), 355 nm (28,169 cm(-1)), and 266 nm (37,594 cm(-1))] and excitation laser power on solid-state uranium compounds. The uranium compounds investigated include uranyl nitrate, uranyl sulfate, uranyl oxalate, uranium dioxide, triuranium octaoxide, uranyl acetate, uranyl formate, zinc uranyl acetate, and uranyl phosphate. We observed the characteristic uranyl fluorescence spectrum from the uranium compounds except for uranium oxide compounds (which do not contain the uranyl moiety) and for uranyl formate, which has a low fluorescence quantum yield. Relative uranyl fluorescence intensity is greatest for 355 nm excitation, and the order of decreasing fluorescence intensity with excitation wavelength (relative intensity/laser output) is 355 nm > 266 nm > 532 nm. For 532 nm excitation, the emission spectrum is produced by two-photon excitation. Uranyl fluorescence intensity increases linearly with increasing laser power, but the rate of fluorescence intensity increase is different for different emission bands.  相似文献   

14.
A system for time-gated fluorescence imaging was used to perform measurements on tumor-bearing mice treated with hematoporphyrin derivative (HpD). The aim of the study was to define the potential of this technique in the diagnosis of tumors by taking advantage of the long fluorescence lifetime of the exogenous dye with respect to the decay times of the natural fluorescence. After the administration of three different drug doses (5, 10 and 25 mg/kg body weight), fluorescence images were acquired at various uptake times (from 2 h to 10 d), to determine the best instrumental conditions and experimental procedure for the detection of tumors in the murine model considered. The optimal fluorescence contrast between the tumor area and the surrounding healthy tissue was found at 12 h after the administration of either 5 or 10 mg/kg HpD and was anticipated at 8 h for the highest drug dose. In this optimum condition, the tumor region could be identified even after the injection of 5 mg/kg HpD. A better fluorescence contrast was always obtained in 15 ns-delayed images with respect to synchronous ones.  相似文献   

15.
Chan KC  Muschik GM  Issaq HJ 《Electrophoresis》2000,21(10):2062-2066
Two solid-state UV lasers were applied to the laser-induced fluorescence (LIF) detection of various groups of compounds after separation by capillary electrophoresis. These lasers are thermoelectric-cooled, highly compact, and inexpensive. Such lasers provide few mW of quasi-continuous wave (CW) power which are sufficient and stable for LIF detection. Native fluorescence detection of tryptophan-containing proteins and peptides and related indoles was achieved at the nM level with the laser operating at 266 nm. Detection of fluorescamine-labeled amino acids and peptides was also possible at the nM level with the laser operating at 355 nm. Amino acids at a concentration as low as 10 ng/mL could be labeled with fluorescamine. Solid-state UV-LIF detection of the tryptic digest of cytochrome c after fluorescamine derivatization was demonstrated.  相似文献   

16.
The objective of our study was to investigate whether digital imaging of autofluorescence could be applied in the detection of colonic malignancies. Autofluorescence was excited with a 325 nm line from a He-Cd laser. Images were recorded in vitro in six spectral bands. The material for study was 50 resected specimens for which images of 64 areas were recorded. The main result is the observation that for a majority of malignant and premalignant lesions the intensity of autofluorescence was lower than for the corresponding normal mucosa in all of the spectral bands selected for imaging. The spectral bands centered around 440 nm and 475 nm seem to be most promising in terms of possible future clinical applications.  相似文献   

17.
LEDs present an alternative to lasers in LIF detection with CE, resulting in LED-induced fluorescence (LEDIF). LEDs are much less expensive, consume less energy and are more stable. In addition, LED light sources allow a greater range of wavelengths to better match the maximum wavelength for the fluorescence of the dye. Antibodies were largely studied in SDS capillary gel electrophoresis (SDS-CGE) and LIF detection with different dyes to label the proteins. In this work, our goal is to show that LEDs can advantageously replace lasers. We used 5-carboxytetramethylrhodamine succinimidyl ester (5-TAMRA.SE), 3-(2-furoyl)-quinoline-2 carboxaldehyde (FQ), and naphthalene-2,3-dialdehyde (NDA) to label IgG and we compared the LIF sensitivity with that obtained from LEDIF. We measured that the LOD values of LEDIF are identical to that obtained with the wavelength equivalent laser, and for 5-TAMRA.SE analysis, LOD values are about six times better than when the classical 488 nm laser was used.  相似文献   

18.
New L -shaped fluorophores possessing five conjugated rings have been synthesized through a four-step procedure involving diketopyrrolopyrrole synthesis and its double N-alkylation, followed by trimethylsilyl bromide-mediated rearrangement to thieno[2,3-f]isoindole-5,8-dione and an intramolecular Friedel–Crafts reaction. In comparison with the parent isoindolediones and π-expanded diketopyrrolopyrroles, these new dyes show red-shifted absorption and emission (up to ≈630 nm). Their structural rigidity is responsible for both the observed small Stokes shifts and large fluorescence quantum yields. Tissue imaging studies revealed that these new dyes show advantageous features including minimal autofluorescence interference and pronounced solvent-sensitive emission. Interestingly, there is a fundamental difference between a dye possessing an amino group and its analog bearing an N-alkyl substituent. The former dye under two-photon excitation at 900 nm gives bright images whereas its N-alkylated counterpart does not. A new type of membrane localization has been discovered by an N-alkylated isoindoledione possessing a benzofuryl substituent. In spite of the fact that the fluorescence quantum yield of this dye in a range of solvents is rather low, it does stain cell membranes exclusively. This new mode of cellular staining opens the door towards further development of membrane staining dyes.  相似文献   

19.
Although histochemical and immunohistochemical methods are the standard procedures in diagnosis of lymphoproliferative disorders, useful improvements in evidencing histopathologic manifestations can be obtained with the introduction of tissue autofluorescence analyses. We used microspectrofluorometry and a Multispectral Imaging Autofluorescence Microscopy (MIAM) technique to analyze lymph-node biopsies from patients with lymphoadenopathy of different origins. Images of tissue autofluorescence were obtained by excitation at 365 nm of lymph-node sections and sequential detection with interference filters (50 nm bandwidth) peaked at 450, 550 and 658 nm. Monochrome images were combined together in a single red-green-blue color image. Most of the fluorescence was observed within the blue spectral band because of large contributions from extracellular collagen and elastin fibers as well as from reduced form of intracellular nicotinamide adenine dinucleotide (phosphate). Autofluorescence imaging shows morphological differences between neoplastic and non-neoplastic tissues. The reactive hyperplasia samples show the typical lymph-node organization with weak fluorescent follicles separated by high fluorescent connective trabeculae. In the neoplastic lymph nodes the loss of follicle organization is observed. Consequently, MIAM permits to discriminate between non-neoplastic and neoplastic tissues on the basis of their autofluorescence pattern. Multispectral imaging of tissue autofluorescence may present some advantages with respect to standard histochemical microscopy since it (1) does not require any chemical manipulation of samples; (2) gives real-time results performing the analysis immediately upon specimen resection; and (3) supplies a representation of the biological structure organization linked to endogenous fluorophores.  相似文献   

20.
FLUORESCENCE SPECTRA IN LUNG WITH PORPHYRIN INJECTION   总被引:2,自引:0,他引:2  
The fluorescence emission spectra from human bronchial mucosa and tumors, before and after injection of dihematoporphyrin ether/ester, have been measured with an optical multichannel analyzer from 500 to 750 nm. Fluorescence was excited with a violet krypton ion laser (average wavelength 410 nm). The autofluorescence spectra decrease monotonically with increasing wavelength except for a small broad peak near 600 nm. The spectra from tumor sites, after injection of the fluorescent porphyrin, exhibit the characteristic fluorescence emission at 630 and 690 nm, added to the autofluorescence spectrum. The spectra from control or nontumor sites are similar but the magnitude of the component due to the injected porphyrin is smaller than at a tumor site. The magnitude ratio of tumor to control site fluorescence depends on concentration of the porphyrin, tumor thickness, and time after injection. Autofluorescence degrades contrast and thus makes very thin tumors difficult to image. Subtraction of the autofluorescence background is desirable.  相似文献   