首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Amitriptyline, citalopram, fluoxetine, and fluvoxamine were isolated by electro membrane extraction (EME) from 70 μl of untreated plasma (pH 7.4), through a supported liquid membrane (SLM) of 1-ethyl-2-nitrobenzene immobilized in the pores of a porous polypropylene hollow fiber, and into 30 μl of 10 mM HCOOH as acceptor solution inside the lumen of the hollow fiber. The driving force of the extraction was a 9 V potential sustained over the SLM with a common battery, with the positive electrode placed in the plasma sample and the negative electrode placed in the acceptor solution. Extractions were performed under totally stagnant conditions with a very simple device for 1 min (kinetic regime), and subsequently the acceptor solution was analyzed directly by liquid chromatography–mass spectrometry (LC–MS). Recoveries were 12, 13, 22, and 17% for fluoxetine, amitriptyline, citalopram, and fluvoxamine, respectively. Sample clean-up was comparable to reversed-phase solid-phase extraction (SPE), but EME required substantially less time than SPE. The time advantage of EME was further improved by parallel extraction of three samples (for 1 min) with the same 9 V battery. EME from plasma combined with LC–MS provided limits of quantification (S/N = 10) in the range 0.4–2.3 ng/ml, linearity in the range 1–1000 ng/ml with r2-values of 0.998–0.999, and repeatability in the range 3.2–8.9% RSD in the mid-therapeutic window (100 ng/ml).  相似文献   

2.
The present work describes the first systematic study of electromembrane extraction (EME) from biological matrices under physiological conditions. Six basic drugs with protein binding in the range of 20–97% were extracted from untreated human plasma and whole blood through a supported liquid membrane (SLM) consisting of 1-ethyl-2-nitrobenzene impregnated in the walls of a hollow fiber, and into an acidified aqueous solution inside the lumen of the fiber. The electrical potential difference over the membrane reduced the protein binding of the drugs and transported the free drug fraction over the membrane. Recoveries in the range 25–65% were obtained with 10-min extraction time and an applied voltage of only 10 V over the SLM. Interday precision better than 20% RSD and linearity in the range 0.5–10 μg/mL were obtained for nortriptyline and methadone. Extraction from untreated whole blood was also demonstrated with recoveries in the range 19–51%.  相似文献   

3.
Planar polyamide 6 nanofibrous membrane was for the first time used in direct coupling of supported liquid membrane (SLM) extraction to CE analysis. Disposable microextraction device with the nanofibrous membrane was preassembled and stored for immediate use. The membrane in the device was impregnated with 1 µL of 1‐ethyl‐2‐nitrobenzene and the device was subsequently filled with 10 µL of acceptor solution (10 mM HCl) and 15 µL of donor solution (sample). The device was in‐line coupled to CE system for selective extraction and direct injection, separation and quantification of model basic drugs (nortriptyline, haloperidol, loperamide and papaverine) from standard saline solutions (150 mM NaCl) and from undiluted human body fluids (urine and blood plasma). Compared to standard polypropylene supporting material, the nanofibrous membrane demonstrated superior characteristics in terms of lower consumption of organic solvents, constant volumes of operational solutions, full transparency and possibility to preassemble the devices. Extraction parameters were better or comparable for the nanofibrous vs. the polypropylene membrane and the hyphenated SLM‐CE method with the nanofibrous membrane was characterized by good repeatability (RSD ≤ 11.3%), linearity (r2 ≥ 0.9953; 0.5–20 mg/L), sensitivity (LOD ≤ 0.4 mg/L) and transfer (27–126%) of the basic drugs.  相似文献   

4.
A large screening of different components in the supported liquid membrane (SLM) in electromembrane extraction (EME) was performed to test the extraction efficiency on eight model peptides. Electromembrane extraction from a 500 μL acidified aqueous sample containing the model peptides in the concentration 10 μg/mL was used. Extraction time was 5 min with an electric potential of 10 V and 900 rpm agitation of the sample vial. The samples were extracted through a hollow fiber-based SLM with different compositions of organic solvents and carriers. A small volume of acidified acceptor solution (25 μL) was after extraction analyzed directly, or with some dilution, on CE or HPLC. This article has identified mono- or di-substituted phosphate groups as the prominent group of carrier molecules needed to obtain acceptable recoveries. For the organic solvents, primary alcohols and ketones have shown promise regarding recovery and reproducibility, with some differences in selectivity. A new composition of the SLM, namely 2-octanone and tridecyl phosphate (90:10 w/w) has proved to give higher extraction recoveries and lower standard deviation than SLMs previously reported in the literature.  相似文献   

5.
In this work, the simple analytical method for the determination of four fluoroquinolone antibiotics: ciprofloxacin, enrofloxacin, norfloxacin and danofloxacin, in environmental surface water samples is described. Sample pretreatment step was performed by the application of a technique based on supported liquid membrane extraction with the configuration of single hollow fiber (HF-SLM). The HPLC system with diode array detection was used for final analysis of studied analytes. Various parameters affecting the extraction efficiency during HF-SLM enrichment, such as type of membrane diluent, pH of donor (sample) and acceptor phases, as well as an enrichment time and salt content of sample were studied. Using the presented hollow-fiber extraction high recovery (70–80%) was achieved. It gave enrichment factor above 100. The detection limits in surface water samples, for the four target antibiotics, were at range 0.01–0.02 μg/l, when 10 ml samples were processed. The obtained results demonstrate the applicability of presented method for the selective extraction of fluoroquinolones in environmental water samples at ultratrace level. Errors, expressed as relative standard deviation (RSD) were below 8%, for all tested concentration levels.  相似文献   

6.
The present study has for the first time demonstrated the isolation of peptides from human plasma by electromembrane extraction (EME). Angiotensin 1, angiotensin 2, and angiotensin 3 migrated from 500 μL of diluted plasma, through a thin layer of 1-octanol and 8% di-(2-ethylhexyl) phosphate immobilized as a supported liquid membrane (SLM) in the pores of a porous hollow fiber, and into a 25 μL aqueous acceptor solution present inside the lumen of the fiber. The driving force for the extraction was a 15 V potential difference applied across the SLM. After only 10 min of EME, the peptides were isolated from diluted plasma (pH 3) with extraction recoveries between 25 and 43%. After optimization, the extraction system was evaluated using spiked plasma samples of angiotensin 2. The evaluation was performed by liquid chromatography electrospray mass spectrometry, showing linearity of angiotensin 2 in the range 2.5–125.0 ng/mL (r2 = 0.989), and repeatability (RSD) between 5.6 and 11.6% (n = 6). The results demonstrate the possibility of isolating angiotensin peptides from plasma in only 10 min, using electromembrane extraction. The experimental findings are therefore promising with regard to future peptide extractions.  相似文献   

7.
An electro membrane extraction (EME) methodology was utilized to study the isolation of some environmentally important pollutants, such as chlorophenols, from aquatic media based upon the electrokinetic migration process. The analytes were transported by application of an electrical potential difference over a supported liquid membrane (SLM). A driving force of 10 V was applied to extract the analytes through 1-octanol, used as the SLM, into a strongly alkaline solution. The alkaline acceptor solution was subsequently analyzed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The parameters influencing electromigration, including volumes and pH of the donor and acceptor phases, the organic solvent used as the SLM, and the applied voltage and its duration, were investigated to find the most suitable extraction conditions. Since the developed method showed a rather high degree of selectivity towards pentachlorophenol (PCP), validation of the method was performed using this compound. An enrichment factor of 23 along with acceptable sample clean-up was obtained for PCP. The calibration curve showed linearity in the range of 0.5–1000 ng/mL with a coefficient of estimation corresponding to 0.999. Limits of detection and quantification, based on signal-to-noise ratios of 3 and 10, were 0.1 and 0.4 ng/mL, respectively. The relative standard deviation of the analysis at a PCP concentration of 0.5 ng/mL was found to be 6.8% (n = 6). The method was also applied to the extraction of this contaminant from seawater and an acceptable relative recovery of 74% was achieved at a concentration level of 1.0 ng/mL.  相似文献   

8.
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor–SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7–8, which was below the pKa-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pKa-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature.  相似文献   

9.
Electromembrane extraction (EME) of polar basic drugs from human plasma was investigated for the first time using pure bis(2-ethylhexyl) phosphite (DEHPi) as the supported liquid membrane (SLM). The polar basic drugs metaraminol, benzamidine, sotalol, phenylpropanolamine, ephedrine, and trimethoprim were selected as model analytes, and were extracted from 300 μL of human plasma, through 10 μL of DEHPi as SLM, and into 100 μL of 10 mM formic acid as acceptor solution. The extraction potential across the SLM was 100 V, and extractions were performed for 20 min. After EME, the acceptor solutions were analyzed by high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In contrast to other SLMs reported for polar basic drugs in the literature, the SLM of DEHPi was highly stable in contact with plasma, and the system-current across the SLM was easily kept below 50 μA. Thus, electrolysis in the sample and acceptor solution was kept at an acceptable level with no detrimental consequences. For the polar model analytes, representing a log P range from −0.40 to 1.32, recoveries in the range 25–91% were obtained from human plasma. Strong hydrogen bonding and dipole interactions were probably responsible for efficient transfer of the model analytes into the SLM, and this is the first report on efficient EME of highly polar analytes without using any ionic carrier in the SLM.  相似文献   

10.
Electromembrane extraction (EME) of basic drugs from 10 μL sample volumes was performed through an organic solvent (2-nitrophenyl octyl ether) immobilized as a supported liquid membrane (SLM) in the pores of a flat polypropylene membrane (25 μm thickness), and into 10 μL 10 mM HCl as the acceptor solution. The driving force for the extractions was 3–20 V d.c. potential sustained over the SLM. The influence of the membrane thickness, extraction time, and voltage was investigated, and a theory for the extraction kinetics is proposed. Pethidine, nortriptyline, methadone, haloperidol, and loperamide were extracted from pure water samples with recoveries ranging between 33% and 47% after only 5 min of operation under totally stagnant conditions. The extraction system was compatible with human urine and plasma samples and provided very efficient sample pretreatment, as acidic, neutral, and polar substances with no distribution into the organic SLM were not extracted across the membrane. Evaluation was performed for human urine, providing linearity in the range 1–20 μg/mL, and repeatability (RSD) in average within 12%.  相似文献   

11.
Effects of organic solvent type, pH value, and composition of donor/acceptor solution on the efficacy of electromembrane extraction (EME) were examined. For the first time, a comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter‐ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes (SLMs). The EME transfer of model analytes correlated well with electrophoretic mobilities of inorganic cations, which were added to acceptor solutions during their alkalization with alkali metal hydroxides, and were highest for counter‐cations with highest mobilities. Up to a 53‐fold improvement of extraction efficiency was achieved for EMEs using optimized composition of donor (alkalized with KOH to pH 7) and acceptor (10 mM CsOH, pH 12) solutions. Six chlorophenols (CPs) were selected as model analytes due to the wide range of pH values that are required for their ionization and due to their high environmental relevance; quantitative measurements were carried out by CE with UV detection. Extraction recoveries of the six CPs ranged between 14 and 25% for 5 min EMEs at 150 V and 750 rpm across SLMs impregnated with 1‐ethyl‐2‐nitrobenzene. Calibration curves were strictly linear (r2 ≥ 0.999) in 0.01–10 μg/mL range, repeatability values of peak areas were between 0.7 and 5.6% and LODs for standard solutions and environmental samples were better than 5 ng/mL.  相似文献   

12.
In this paper, an electromembrane extraction (EME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of six widely used non-steroidal anti-inflammatory drugs (NSAIDs): salicylic acid (SAC), ketorolac (KTR), ketoprofen (KTP), naproxen (NAX), diclofenac (DIC) and ibuprofen (IBU). The drugs were extracted from basic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 1-octanol impregnated in the walls of a S6/2 Accurel® polypropylene hollow fiber, and into a basic aqueous acceptor solution resent inside the lumen of the hollow fiber with a potential difference of 10 V applied over the SLM. Extractions that were carried out in 10 min using a potential of 10 V from pH 12 NaOH aqueous solutions shown concentration enrichments factors of 28-49 in a pH 12 NaOH aqueous acceptor solution. The proposed method was successfully applied to urban wastewaters. Excellent selectivity was demonstrated as no interfering peaks were detected. The procedure allows very low detection and quantitation limits of 0.0009-9.0 and 0.003-11.1 μg L−1, respectively.  相似文献   

13.
Fundamental experiments on electromembrane extraction were performed to increase the basic knowledge about the current and the mass transfer of target peptides and background electrolyte ions. Three peptides (angiotensin 2, bradykinin, and enkephalin) were extracted from 500 μL aqueous donor solution (1 mM HCl, positive electrode), through a 200 μm supported liquid membrane (SLM) of 1‐octanol/di‐isobutylketon/di‐(2‐ethylhexyl) phosphate (55:35:10 w/w/w) sustained in the pores of a porous hollow fiber, and into 25 μL aqueous acceptor solution (50 mM HCl, negative electrode) present inside the lumen of the fiber by the application of an electrical potential (50 V) and agitation (1050 rpm). Recoveries were typically in the range of 55–65% after 5 min of extraction and were principally determined by the chemical composition of the SLM and by the applied voltage. The electrical current in the system was measured during the extraction and was close to 350 μA. The current arose to some extent from mass transfer of the target peptides, but the major contribution was due to a background current from di‐(2‐ethylhexyl) phosphate in the SLM and from mass transfer of background electrolytes. Operation at relatively low background current was important to maintain a stable system.  相似文献   

14.
Combining the continuous flow liquid-liquid extraction (CFLLE) and supported liquid membrane (SLM) extraction, a novel aqueous-aqueous extraction technique that we termed continuous flow liquid membrane extraction (CFLME) is developed for trace-enrichment. The analyte was firstly extracted into the organic phase in the CFLLE step, then transported onto the organic liquid membrane that formed on the surface of the micro porous membrane of the SLM equipment. Finally, it passed through the liquid membrane and was trapped by the acceptor. Aspects related to CFLME were studied by using dichloromethane as liquid membrane, and sulfonylurea herbicides as model compounds. An enrichment factor of over 1000 was obtained when 10 μg l−1 of MSM was enriched for 120 min by this technique. The drawbacks of only a few organic solvents can be selected as liquid membrane with a limited lifetime in SLM operation was overcome. In this CFLME method, almost all solvents that used in the conventional liquid-liquid extraction (LLE) can be adopted and the lifetime of liquid membrane is no longer a problem.  相似文献   

15.
By the application of an electrical potential difference (25 V), 37 different peptides were extracted from 500 μL aqueous sample (10 mM formic acid, positive electrode), through a supported liquid membrane (SLM) impregnated in the walls of a porous hollow fiber, and into 25 μL aqueous acceptor solution (100 mM formic acid, negative electrode) present inside the lumen of the fiber. Most of the peptides were obtained by tryptic digestion of cytochrome c and bovine serum albumin, which yielded complex samples for extraction. Three different SLMs were utilized to correlate the peptides extractability with the highly variable physical-chemical properties of the peptides. The first SLM (pure eugenol) provided an electromembrane extraction system for hydrophobic and intermediate peptides (hydrophilicity values below 0.2), where the extraction of peptides into the SLM was mainly based on solvent interactions. The second SLM (1-octanol/di-isobutylketone/di-(2-ethylhexyl) phosphate) extracted both hydrophobic and hydrophilic peptides (hydrophilicity values in the range from -2 to+1) successfully, and the transfer of peptides was principally based on ionic interactions with di-(2-ethylhexyl) phosphate. The third SLM (1-octanol/15-crown-5 ether) was selective for hydrophobic peptides (negative hydrophilicity values), and complexation of the peptides with the crown ether was important for the migration of peptides into the acceptor solution.  相似文献   

16.
Electromembrane extraction (EME) was carried out using a novel instrumentation capable of impedometric monitoring of the system during the extraction. This instrumentation involves a classical two-electrode assembly fed by two time-resolved potential functions, the first for the extraction of analyte and the second for obtaining the impedance information. The impedometric analysis of the system was achieved by Laplace transformation of the current recorded during the extraction. It has been shown that the obtained impedance information can be converted to very useful knowledge about time dependence of double layer capacitance, kinetics of analyte depletion, total permeability of the SLM and the effect of experimental parameters on system behavior. It has also been shown that the impedance analysis is a powerful tool for the estimation of optimum experimental parameters without determination of analyte in the acceptor phase.  相似文献   

17.
A totally new concept based on electrokinetic migration was evaluated for the extraction of three biologically active peptides from human plasma. Angiotensin 2, leu-enkephalin, and endomorphin 1 migrated from a diluted human plasma sample (2 mL, positive electrode), through a supported liquid membrane (SLM) of 1-octanol, di-isobutylketon, and di-(2-ethylhexyl) phosphate (DEHP) (55:35:10, w/w/w), and into an acidified acceptor solution (25 μL 50 mM HCl, negative electrode) by the application of an electrical potential (20 V) across the SLM. After only five min of extraction, the acceptor solution was injected and analyzed directly by liquid chromatography. The three peptides were quantified by tandem mass spectrometry, with acceptable linearity ranging from 100.0 to 1000.0 pg mL−1 (r2 in the range 0.9736–0.9988), and repeatability (RSD) ranging between 15% and 24% (n = 5), using plasma spiked with the three peptides in 100 pg mL−1 concentration. The estimated detection limits (S/N ratio of 3:1) for angiotensin 2, leu-enkephalin, and endomorphin 1, were 60, 24, and 24 pg mL−1, respectively. With this novel approach based on electromembrane extraction (EME) coupled to LC–MS/MS, endogenous concentrations of the peptides were detected in non-spiked human plasma samples, with a total analysis time less than 50 min. These experimental findings were highly interesting, and showed the opportunities for EME with regard to future peptide extractions.  相似文献   

18.
The reviews cover important critical parameters that are often optimized in a supported liquid membrane extraction technique in both flat sheet and hollow fibre designs for ionizable organic molecules. Understanding of these parameters can enable one to predict the behavior of the compound before hand and thus reduce the number of optimization experiments. Moreover, less number of experiments can be also generated using statistical techniques which are now becoming more commonly used. Supported liquid membrane extraction optimal parameters such as the conditions of the pH of the acceptor and donor phases should easily be fixed from the pKa values of the compounds. Other parameters, including the polarity of the compound can help to predict the partitioning into the membrane and the behavior of the compound. The influence of parameters such as temperature on the mass transfer in supported liquid membrane depends on the design of the module, experimental design and type of mass transfer controlling the extraction process.  相似文献   

19.
This fundamental work illustrates for the first time the possibility of exhaustive extraction of peptides using electromembrane extraction (EME) under low system-current conditions (<50 μA). Bradykinin acetate, angiotensin II antipeptide, angiotensin II acetate, neurotensin, angiotensin I trifluoroacetate, and leu-enkephalin were extracted from 600 μL of 25 mM phosphate buffer (pH 3.5), through a supported liquid membrane (SLM) containing di-(2-ethylhexyl)-phosphate (DEHP) dissolved in an organic solvent, and into 600 μL of an acidified aqueous acceptor solution using a thin flat membrane-based EME device. Mass transfer of peptides across the SLM was enhanced by complex formation with the negatively charged DEHP. The composition of the SLM and the extraction voltage were important factors influencing recoveries and current with the EME system. 1-nonanol diluted with 2-decanone (1:1 v/v) containing 15% (v/v) DEHP was selected as a suitable SLM for exhaustive extraction of peptides under low system-current conditions. Interestingly, increasing the SLM volume from 5 to 10 μL was found to be beneficial for stable and efficient EME. The pH of the sample strongly affected the EME process, and pH 3.5 was found to be optimal. The EME efficiency was also dependent on the acceptor solution composition, and the extraction time was found to be an important element for exhaustive extraction. When EME was carried out for 25 min with an extraction voltage of 15 V, the system-current across the SLM was less than 50 μA, and extraction recoveries for the model peptides were in the range of 77–94%, with RSD values less than 10%.  相似文献   

20.
The repeatability and extraction recoveries of parallel electromembrane extraction (Pa-EME) was thoroughly investigated in the present project. Amitriptyline, fluoxetine, and haloperidol were isolated from eight samples of pure water, undiluted human plasma, and undiluted human urine, respectively; in total 24 samples were processed in parallel. The repeatability was found to be independent of the different sample matrices (pure water samples, human plasma, and water) processed in parallel, although the respective samples contained different matrix components. In another experiment seven of the 24 wells were perforated. Even though the perforation caused the total current level in the Pa-EME setup to increase, the intact circuits were unaffected by the collapse in seven of the circuits. In another approach, exhaustive extraction of amitriptyline, fluoxetine, and haloperidol was demonstrated from pure water samples. Amitriptyline and haloperidol were also isolated exhaustively from undiluted human plasma samples; the extraction recovery of fluoxetine from undiluted human plasma was 81%. Finally, the sample throughput was increased with the Pa-EME configuration. The extraction recoveries were investigated by processing 1, 8, 68, or 96 samples in parallel in 10 min; neither the extraction recoveries nor the repeatability was affected by the total numbers of samples. Eventually, the Pa-EME was combined with ultra performance liquid chromatography (UPLC) to combine high-throughput sample preparation with high-throughput analytical instrumentation. The aim of the present investigation was to demonstrate the potential of electromembrane extraction as a high throughput sample preparation platform; and hopefully to increase the interest for EME in the bioanalytical field to solve exisiting and novel analytical challenges.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号