首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
建立了微芯片毛细管电泳非接触电导检测法快速测定盐酸倍他洛尔滴眼液中盐酸倍他洛尔的含量。探讨了缓冲液类型、浓度、分离电压及进样时间等因素对分离检测的影响。实验采用1.5 mmol·L-1HAc-1.5mmol·L-1Na Ac(p H=4.69)为缓冲溶液,分离电压为2.1 k V,进样时间10.0 s。此条件下于0.7 min内实现了盐酸倍他洛尔的快速分离测定。盐酸倍他洛尔的浓度在5.0~200.0μg·m L-1线性良好(r=0.9997,n=6),检出限为1.0μg·m L-1(S/N=3),RSD为0.8%,样品的加标回收率为100.4%~102.0%。滴眼液中的辅料在该条件下不干扰测定,可成功测定盐酸倍他洛尔滴眼液中盐酸倍他洛尔的含量。  相似文献   

2.
An integrated detection circuitry based on a lock-in amplifier was designed for contactless conductivity determination of heavy metals. Combined with a simple-structure electrophoresis microchip, the detection system is successfully utilized for the separation and determination of various heavy metals. The influences of the running buffer and detection conditions on the response of the detector have been investigated. Six millimole 2-morpholinoethanesulfonic acid + histidine were selected as buffer for its stable baseline and high sensitivity. The best signals were recorded with a frequency of 38 kHz and 20 V(pp). The results showed that Mn(2+), Cd(2+), Co(2+), and Cu(2+) can be successfully separated and detected within 100 s by our system. The detection limits for five heavy metals (Mn(2+), Pb(2+), Cd(2+), Co(2+), and Cu(2+)) were determined to range from about 0.7 to 5.4 μM. This microchip system performs a crucial step toward the realization of a simple, inexpensive, and portable analytical device for metal analysis.  相似文献   

3.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

4.
Tanyanyiwa J  Hauser PC 《Electrophoresis》2002,23(21):3781-3786
The detection of alkali, alkaline earth and heavy metal ions with a high-voltage capacitively coupled contactless conductivity detector (HV-C(4)D) was investigated. Eight alkali, alkaline earth metal ions and ammonium could be separated in less than 4 min with detection limits in the order of 5 x 10(-8) M. The heavy metals Mn2+, Pb2+, Cd2+ Fe2+, Zn2+, Co2+, Cu2+ and Ni2+ could also be successfully resolved with a 10 mM 2-(N-morpholino)ethanesulfonic acid/DL-histidine (MES/His)-buffer. Zn2+, Co2+, Cu2+ and Ni2+ showed an indirect response. The detection limits for the heavy metals were determined to range from about 1 to 5 microM.  相似文献   

5.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

6.
A simple microchip CE method integrated with contactless conductivity detection was developed for the direct determination of partition coefficients of selected pharmaceuticals after phase distribution equilibrium. The equilibrium of distribution between two phases for four pharmaceuticals was performed using a 1‐octanol/water system and 1‐octanol/buffer system. During the concentration determination, several major factors affecting detection were investigated in detail for each pharmaceutical to optimize the detection sensitivity. In the optimal conditions, sufficient electrophoretic separation and sensitive detection for each target analyte can be achieved within 40 s. The two systems showed a pH‐dependent partition behavior. Moreover, the measured values showed excellent agreement with those obtained by the traditional shake‐flask method with HPLC–UV detection and literature reports, respectively. The developed method can be successfully applied to measure partition coefficient values of pharmaceuticals and requires much shorter analytical time compared to traditional methods.  相似文献   

7.
Kubán P  Hauser PC 《Electrophoresis》2005,26(16):3169-3178
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.  相似文献   

8.
Paracetamol (PAC) is one of the most extensively used analgesics and antipyretic drugs to treat mild and moderate pain. P-aminophenol (PAP), the main hydrolytic degradation product of PAC, can be found in environmental water. Recently, CE has been developed for the detection of a wide variety of chemical substances. The purpose of this study is to develop a simple and fast method for the detection and separation of PAC and its main hydrolysis product PAP using CE and microchip electrophoresis with capacitively coupled contactless conductivity detection. The determination of these compounds using microchip electrophoresis with capacitively coupled contactless conductivity detection is being reported for the first time. The separation was run for all analytes using a BGE (20 mM β-alanine, pH 11) containing 14% (v/v) methanol. The RSDs obtained for migration time were less than 4%, and RSDs obtained for peak area were less than 7%. The detection limits (S/N = 3) that were achieved ranged from 0.3 to 0.6 mg/L without sample preconcentration. The presented method showed rapid analysis time (less than 1 min), high efficiency and precision, low cost, and a significant decrease in the consumption of reagents. The microchip system has proved to be an excellent analytical technique for fast and reliable environmental applications.  相似文献   

9.
Tanyanyiwa J  Hauser PC 《Electrophoresis》2004,25(17):3010-3016
The extension of contactless conductivity detection in electrophoresis to the determination of basic drugs is demonstrated using beta-adrenergic blocking agents (beta-blockers) and other physiologically active amines as examples. The high-voltage approach to conductivity detection was employed for conventional capillaries as well as microchip devices. Acidic buffers were used in all cases. A buffer consisting of 100 mM acetic acid and 1 mM histidine was deemed most optimal for the separation of six beta-blockers and best results for the analysis of the other amines were achieved with a 20 mM lactic acid buffer at low pH-value. The detection limits ranged from 0.06 to 5 microM. To demonstrate potential practical applications, a main component assay was conducted for three pharmaceutical formulations. On-chip, five pharmaceutical amines could be baseline-resolved in a 8 cm long microchannel in 90 s, albeit a reduced sensitivity and peak capacity compared to conventional capillary electrophoresis.  相似文献   

10.
Law WS  Kubán P  Yuan LL  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2006,27(10):1932-1938
A study on the determination of the antibiotic tobramycin by CE with capacitively coupled contactless conductivity detection is presented. This method enabled the direct quantification of the non-UV-absorbing species without incurring the disadvantages of the indirect approaches which would be needed for optical detection. The separation of tobramycin from inorganic cations present in serum samples was achieved by optimizing the composition of the acetic acid buffer. Field-amplified sample stacking was employed to enhance the sensitivity of the method and a detection limit of 50 microg/L (S/N = 3) was reached. The RSDs obtained for migration time and peak area using kanamycin B as internal standard were typically 0.12 and 4%, respectively. The newly developed method was validated by measuring the concentration of tobramycin in serum standards containing typical therapeutic concentrations of 2 and 10 mg/L. The recoveries were 96 and 97% for the two concentrations, respectively.  相似文献   

11.
A method for the determination of gamma-hydroxybutyric acid (GHB) in urine and serum samples with capillary electrophoresis using capacitively coupled contactless conductivity detection (CE-C(4)D) was developed. The optimized separation buffer consisting of 20 mM of arginine, 10 mM of maleic acid and 30 microM of cetyltrimethylammonium bromide (CTAB) contained 5 mM vancomycin to facilitate the separation of gamma-hydroxybutyric acid from beta-hydroxybutyric acid (BHB), which is also present in clinical samples. The detection limits in the clinical samples were found to be about 2 microg/ml, which is well below the required sensitivity for the recognition of overdosage and adequate for the determination of endogenous concentrations in urine. The determination of GHB in both types of samples was carried out directly after a fourfold dilution without requiring any derivatization or extraction procedures.  相似文献   

12.
Micro-electrodialysis (μED) and CE were combined for rapid pretreatment and subsequent determination of inorganic cations in biological samples. Combination of μED with CE greatly improved the analytical performance of the latter as the adsorption of high molecular weight compounds present in real samples on the inner capillary wall was eliminated. Fifty microliter of 80-fold diluted human body fluids such as plasma, serum and whole blood was used in the donor compartment of the μED system requiring less than 1?μL of the original body fluid per analysis. Inorganic cations that migrated through a cellulose acetate dialysis membrane with molecular weight cut-off value of 500?Da were collected in the acceptor solution and were then analyzed using CE-C?D. Baseline separation of inorganic cations was achieved in a BGE solution consisting of 12.5?mM maleic acid, 15?mM L-arginine and 3?mM 18-crown-6 at pH 5.5. Repeatability of the CE-C?D method was better than 0.5% and 2.5% for migration times and peak areas, respectively; limits of detection of all inorganic cations in the presence of 2?mM excess of Na(+) were around 1?μM and calibration curves were linear with correlation coefficients better than 0.998. Repeatability of the sample pretreatment procedure was calculated for six independent electrodialysis runs of artificial and real samples and was better than 11.8%. Recovery values between 96.3 and 110% were achieved for optimized electrodialysis conditions of standard solutions and real samples; lifetime of the dialysis membranes for pretreatment of real samples was estimated to 100 runs.  相似文献   

13.
We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.  相似文献   

14.
Nearly all analyses by capillary electrophoresis (CE) are performed using optical detection, utilizing either absorbance or (laser-induced) fluorescence. Though adequate for many analytical problems, in a large number of cases, e.g., involving non-UV-absorbing compounds, these optical detection methods fall short. Indirect optical detection can then still provide an acceptable means of detection, however, with a strongly reduced sensitivity. During the past few years, contactless conductivity detection (CCD) has been presented as a valuable extension to optical detection techniques. It has been demonstrated that with CCD detection limits comparable, or even superior, to (indirect) optical detection can be obtained. Additionally, construction of the CCD around the CE capillary is straightforward and robust operation is easily obtained. Unfortunately, in the literature a large variety of designs and operating conditions for CCD were described. In this contribution, several important parameters of CCD are identified and their influence on, e.g., detectability and peak shape is described. An optimized setup based on a well-defined detection cell with three detection electrodes is presented. Additionally, simple and commercially available read-out electronics are described. The performance of the CCD-CE system was demonstrated for the analysis of peptides. Detection limits at the microM level were obtained in combination with good peak shapes and an overall good performance and stability.  相似文献   

15.
Zemann AJ 《Electrophoresis》2003,24(12-13):2125-2137
Capacitively coupled contactless conductivity detection (C(4)D) has become an accepted detection method in capillary electrophoresis (CE) for a variety of analytes. Advantages of this technique over optical detection modes and galvanic contact conductivity detection include great flexibility in capillary handling and rather simple mechanical parts and electronics, as it can be performed in an on-capillary mode. Furthermore, the detection principle can be used with capillaries made of other materials than fused silica (PEEK, Teflon), with chip-based separation technologies, or with capillaries having very small inner diameters. This review presents a discussion of the published literature on C(4)D for CE and capillary electrochromatography.  相似文献   

16.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

17.
Lithium salts are still one of the most popular therapeutic approaches to the treatment of bipolar disorders, notwithstanding the introduction of more modern, less toxic drugs. Because of a narrow therapeutic range, lithium serum concentrations must be strictly monitored during the treatment to avoid life-threatening neurotoxicity. For this purpose, methods based on flame photometry or ion-selective electrodes are usually applied. The aim of the present work was to develop and validate a simple method for the determination of lithium in serum based on capillary zone electrophoresis with indirect detection. A validation of the method was carried out, including a comparison with an automated routine method based on ion-selective electrodes.  相似文献   

18.
Willauer HD  Collins GE 《Electrophoresis》2003,24(12-13):2193-2207
Capillary electrophoresis microchip devices are receiving considerable attention due to their versatility, portability, and sample handling capabilities. This article is a comprehensive review of the analysis of inorganic and small, charged organic species on microchip platforms. The application of conductivity, amperometry, laser-induced fluorescence, absorbance, and chemiluminescence detection methods are discussed. The potential utilization of these devices for miniaturized analytical systems is described.  相似文献   

19.
Vrouwe EX  Luttge R  van den Berg A 《Electrophoresis》2004,25(10-11):1660-1667
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.  相似文献   

20.
The sensitivity of contactless conductivity detection to amino acids, peptides and proteins in CE was studied for BGE solutions of different pH values. The LOD and analytical characteristics were compared for acidic and basic conditions and better results were in most cases found for buffers of low pH values. Linear dynamic ranges varied between two orders of magnitude for amino acids and peptides and three orders of magnitude for larger proteins. The concentration detection limits were found to be between 1.2 and 7.5 microM for the amino acids tested and for the larger molecules they varied between 2.6 microM for leucine enkephalin and 0.2 microM for HSA when using a buffer at pH 2.1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号