首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Song Y  Zhang H  Chon CH  Chen S  Pan X  Li D 《Analytica chimica acta》2010,681(1-2):82-86
This paper reports a lab-on-a-chip device that counts the number of bacteria flowing through a microchannel. The bacteria number counting is realized by a microfluidic differential Resistive Pulse Sensor (RPS). By using a single microfluidic channel with two detecting arm channels placed at the two ends of the sensing section, the microfluidic differential RPS can achieve a high signal-to-noise ratio. This method is applied to detect and count bacteria in aqueous solution. The detected RPS signals amplitude for Pseudomonas aeruginosa ranges from 0.05 V to 0.17 V and the signal-to-noise ratio is 5-17. The number rate of the bacteria flowing through the sensing gate per minute is a linear function of the sample concentration. Using this experimentally obtained correlation curve, the concentration of bacteria in the sample solution can be evaluated within several minutes by measuring the number rate of the bacteria flowing through the sensing gate of this microfluidic differential RPS chip. The method described in this paper is simple and automatic, and have wide applications in determining the bacteria and cell concentrations for microbiological and other biological applications.  相似文献   

2.
Kang Y  Wu X  Wang YN  Li D 《Analytica chimica acta》2008,626(1):97-103
A fluorescence-activated particle counting and sorting system is developed for lab-on-a-chip applications. This system integrates the microfluidic chip, fluorescence excitation and detection, electronic power switch control, and optical visualization. The automatic sorting function is achieved by electrokinetic flow switching, which is triggered by a pre-set fluorescent threshold. A direct current electric pulse is generated to dispense the fluorescent particles to the collection reservoir. A user-friendly software interface is developed for automatic real-time counting, sorting and visualization. The design of the disposable microfluidic chip is simple and easy for integration. This system represents a promising prototype for development of affordable and portable flow cytometric instruments.  相似文献   

3.
Zhang CY  Chao SY  Wang TH 《The Analyst》2005,130(4):483-488
This paper reports a highly sensitive homogenous method for comparative quantification of nucleic acids based on single-molecule detection (SMD) and molecular beacons (MBs). Two different color MBs were used to perform a separation-free comparative hybridization assay for simultaneous quantification of both target and control strands. A fluorescent burst, emitted from a single hybrid when it passes through a minuscule laser-focused region, is detected with high signal-to-noise ratio (SNR) by using single-molecule fluorescence spectroscopy. Targets are quantified via counting of discrete fluorescent bursts. The high SNR achieved in both detection channels overcame the complications of fluorescent variability usually observed in dual-color ensemble measurements. In comparison with the conventional ensemble methods, this method improved the detection limit by 3 orders of magnitude and reduced the probe consumption by 6 orders of magnitude, facilitating a highly sensitive approach for comparative quantification of nucleic acids and offering great promise for genomic quantification without amplification.  相似文献   

4.
Pamme N  Koyama R  Manz A 《Lab on a chip》2003,3(3):187-192
A microfluidic device for counting and sizing particles and particle agglomerates based on laser light scattering is demonstrated. The particles were confined hydrodynamically and passed through a focused laser beam. Scattering at two different angles, 15 degree and 45 degree, was detected. At an acquisition rate of 10 kHz, a throughput of 150 particles s(-1) was achieved. Scattering intensity was found to depend on particle volume for 2 to 9 microm diameter particles. Size discrimination of particles with a diameter ratio of 1: 2 was accomplished. In addition, the scattering signals of particle agglomerates formed in a particle-enhanced immunoassay for C-reactive protein (CRP) were measured. Scattering intensity was found to be dependent on the CRP concentration, 100 ng CRP per mL could be detected. The particle counting method presented is generic and can be employed in a wide variety of assays as well as for cell counting and particle counting.  相似文献   

5.
High‐throughput particle counting by a differential resistive pulse sensing method in a microfluidic chip is presented in this paper. A sensitive differential microfluidic sensor with multiple detecting channels and one common reference channel was devised. To test the particle counting performance of this chip, an experimental system which consists of the microfluidic chip, electric resistors, an amplification circuit, a LabView based data acquisition device was developed. The influence of the common reference channel on the S/N of particle detection was investigated. The relationship between the hydraulic pressure drop applied across the detecting channel and the counting throughput was experimentally obtained. The experimental results show that the reference channel designed in this work can improve the S/N by ten times, thus enabling sensitive high‐throughput particle counting. Because of the greatly improved S/N, the sensing gate with a size of 25 × 50 × 10 μm (W × L × H) in our chips can detect and count particles larger than 1.5 μm in diameter. The counting throughput increases with the increase in the flowing velocity of the sample solution. An average throughput of 7140/min under a flow rate of 10 μL/min was achieved. Comparing with other methods, the structure of the chip and particle detecting mechanism reported in this paper is simple and sensitive, and does not have the crosstalking problem. Counting throughput can be adjusted simply by changing the number of the detecting channels.  相似文献   

6.
This paper describes an innovative integrated micro flow cytometer that presents a new arrangement for the excitation/detection system. The sample liquid, containing the fluorescent marked particles/cells under analysis, is hydrodynamically squeezed into a narrow stream by two sheath flows so that the particles/cells flow individually through a detection region. The detection of the particles/cells emitted fluorescence is carried out by using a collection fiber placed orthogonally to the flow. The device is based on silicon hollow core antiresonant reflecting optical waveguides (ARROWs). ARROW geometry allows one to use the same channel to guide both the sample stream and the fluorescence excitation light, leading to a simplification of the optical configuration and to an increase of the signal-to-noise ratio. The integrated micro flow cytometer has been characterized by using biological samples marked with standard fluorochromes. The experimental investigation confirms the success of the proposed microdevice in the detection of cells. An erratum to this article can be found at  相似文献   

7.
This paper presents an innovative micro flow cytometer which is capable of counting and sorting cells or particles. This compact device employs electrokinetic forces rather than the more conventional hydrodynamic forces technique for flow focusing and sample switching, and incorporates buried optical fibers for the on-line detection of cells or particles. This design approach results in a compact microfluidic system and an easier integration process. The proposed cytometer integrates several critical modules, namely electrokinetic-focusing devices, built-in control electrodes, buried optical fibers for on-line detection, and electrokinetic flow switches for bio-particle collection. A linear relationship exists between the focused stream width (d) and the focusing ratio (F/φ), which is estimated to be D≈134.5−53.8F/φ. The relationship between the particle velocity (U) and the applied voltage (V) is also investigated. Numerical and experimental data confirm the effectiveness of the device when applied to the counting and sorting of 10 μm diameter particles and red blood cells.  相似文献   

8.
A microfabricated flow cytometer has been developed that is capable of detecting nearly all of the microparticles in an aqueous suspension. Current design allows for integrated coupling between an optical fiber-based detection system and the particle stream via hydrodynamic focusing. By adjusting the relative flow-rates at the auxiliary inputs of the focusing manifold, the particle stream can be steered out-of-plane relative to the illuminating laser, and similarly the particle stream can be squeezed or expanded. The microfabricated device was constructed in polydimethylsiloxane with cross-sectional microfluidic dimensions of 125 μm×125 μm. Using the present device and method, fluorescent microparticles in aqueous solution were counted at an absolute counting efficiency of 91±4%. The coefficient of variation of the fluorescence pulse-heights for far-red fluorescent microparticles was 15%. The device exhibited a linear response to fluorescence intensity calibration microparticles as shown by comparison with a commercial cytometer instrument.  相似文献   

9.
We present a microfluidic device where micro- and nanoparticles can be continuously functionalized in flow. This device relies on an element called "particle exchanger", which allows for particles to be taken from one medium and exposed to some reagent while minimizing mixing of the two liquids. In the exchanger, two liquids are brought in contact and particles are pushed from one to the other by the application of a dielectrophoretic force. We determined the maximum flow velocity at which all the particles are exchanged for a range of particle sizes. We also present a simple theory that accounts for the behaviour of the device when the particle size is scaled. Diffusion mixing in the exchanger is also evaluated. Finally, we demonstrate particle functionalization within the microfluidic device by coupling a fluorescent tag to avidin-modified 880 nm particles. The concept presented in this paper has been developed for synthesis of modified particles but is also applicable to on-chip bead-based chemistry or cellular biology.  相似文献   

10.
A microfluidic assembly method based on a microfluidic chip and capillary device was developed to create multicompartmental particles. The microfluidic chip design endows the particles with regulable internal structure. By adjusting the microstructure of the chip, the diameter of the capillary, the gap length between the two microfluidic components, and the flow rates, the size of the particles and the number or the ratio of different regions within the particle could be widely varied. As a proof of concept, we have produced some complicated particles that even contain 20 compartments. Furthermore, the potential applications of the anisotropic particles are explored by encapsulating magnetic beads, fluorescent nanoparticles, and the cells into different compartments of the microparticles. We believe that this method will open new avenues for the design and application of multicompartmental particles.  相似文献   

11.
12.
On-chip counting the number and the percentage of CD4+ T lymphocytes   总被引:2,自引:0,他引:2  
Wang YN  Kang Y  Xu D  Chon CH  Barnett L  Kalams SA  Li D  Li D 《Lab on a chip》2008,8(2):309-315
A novel technique is reported for counting the number and the percentage of CD4+ T lymphocytes in a polydimethylsiloxane (PDMS) microchannel. This system integrates optical fluorescence detection with resistive pulse sensing enhanced by a metal oxide semiconductor field effect transistor (MOSFET). The MOSFET signal indicates the total number of the cells passing through the detection channel, while the concurrent fluorescence signal records only the number of cells tagged with a specific fluorescent dye. The absolute count of the CD4+ T cells and its percentage to the total lymphocytes can be analyzed by combining the two counting results, which shows comparable accuracy to those from the commercial flow cytometer. The fastest observed counting rate for a single-channel microchip is 8.5 cells per second. This technique is highly promising as it could greatly reduce the cost for HIV diagnosis and treatment and make it accessible to resource-poor developing countries.  相似文献   

13.
Quantification of the fluorescence properties of diffusing particles in solution is an invaluable source of information for characterizing the interactions, stoichiometry, or conformation of molecules directly in their native environment. In the case of heterogeneous populations, single‐particle detection should be the method of choice and it can, in principle, be achieved by using confocal imaging. However, the detection of single mobile particles in confocal images presents specific challenges. In particular, it requires an adapted set of imaging parameters for capturing the confocal images and an adapted event‐detection scheme for analyzing the image. Herein, we report a theoretical framework that allows a prediction of the properties of a homogenous particle population. This model assumes that the particles have linear trajectories with reference to the confocal volume, which holds true for particles with moderate mobility. We compare the predictions of our model to the results as obtained by analyzing the confocal images of solutions of fluorescently labeled liposomes. Based on this comparison, we propose improvements to the simple line‐by‐line thresholding event‐detection scheme, which is commonly used for single‐mobile‐particle detection. We show that an optimal combination of imaging and analysis parameters allows the reliable detection of fluorescent liposomes for concentrations between 1 and 100 pM . This result confirms the importance of confocal single‐particle detection as a complementary technique to ensemble fluorescence‐correlation techniques for the studies of mobile particle.  相似文献   

14.
Separation and detection of individual submicron polystyrene spheres using capillary electrophoresis with laser-light-scattering detection has been demonstrated. Electrophoretically separated particles were passed through a focused laser beam and light scattered from individual particles was collected at 90 degrees. Each diameter of polystyrene spheres injected (from 110 to 992 nm) resulted in the observation of a well-defined migration window containing multiple peaks, each arising from the light scattered by an individual particle. The migration time window for individual particles of a particular size corresponded well to the migration time of a peak from a population of particles of the same size detected using a UV absorbance detector. The electrophoretic mobility and scattered light intensity were determined for each particle detected. The average scattered light intensity for each particle size was consistent with Mie scattering theory. Particles as small as 110 nm in diameter were detected individually using this method, but particles with a diameter of 57 nm could not be individually detected. The number of single particle scattering events was counted and compared to the theoretical number of particles injected electrokinetically, and the detection efficiency determined ranged from 38 to 57% for polystyrene spheres of different sizes. The laser-light-scattering detection method was directly compared to laser-induced fluorescence detection using fluorescent polystyrene microspheres. The number of particles detected individually by each method was in agreement.  相似文献   

15.
去除荧光标记后残余荧光染料可以提高荧光颗粒检测的灵敏度、准确度和效率。该文发展了一种原位电泳洗脱(electrophoretic elution,EE)模型,用于在荧光标记后快速去除多余的荧光探针,实现荧光颗粒的灵敏检测。将牛血清蛋白(BSA)和磁珠(MBs)作为模式蛋白和微颗粒,混合孵育获得MBs-BSA,用异硫氰酸荧光素(FITC)对MBs-BSA标记,得到MBs-BSA_(FITC)复合物。将含有多余FITC的MBs-BSA_(FITC)溶液与低凝聚温度琼脂糖凝胶溶液按1∶5的体积比混合,并将混合物凝胶和纯琼脂糖凝胶分段填充到电泳通道中。电泳过程中,利用颗粒尺寸与凝胶孔径的差异来保留MBs-BSA_(FITC),同时将游离的FITC洗脱。经过30 min的电泳洗脱,通道内多余的FITC清除率达到97.6%,同时目标颗粒荧光信号保留了27.8%。成像系统曝光时间为1.35 s时,电泳洗脱将颗粒与背景的荧光信号比(P/B ratio,PBr)从1.08增加到12.2。CCD相机的曝光时间增加到2.35 s,可以将PBr提高到15.5,可进一步实现对微弱荧光亮点的高灵敏检测。该模型有以下优点:(1)能对颗粒表面非特异性吸附的FITC实现有效洗脱,提高了检测的特异性;(2)能够将97%以上的游离FITC清除;(3)30 min内能够使凝胶内的背景荧光大幅降低,提高了PBr和检测灵敏度。因此,该方法具有在凝胶中进行基于磁珠/荧光颗粒点的免疫检测、在免疫电泳或凝胶电泳中对蛋白质/核酸条带进行荧光染色等领域的应用潜力。  相似文献   

16.
Photon counting statistics in 3D photon counting histogram analysis for one‐photon excitation is a function of the number of molecules of particular brightness in the excitation‐detection volume of a confocal microscope. In mathematical form that volume is approximated by a three‐dimensional Gaussian function which is embedded in the PCH theoretical equations. PCH theory assumes that a molecule can be found anywhere inside the excitation‐detection volume with equal probability. However, one can easily imagine systems in which this assumption is violated because molecules are constrained by the geometry of the sample. For example, molecules on a surface or in a membrane would be constrained to two dimensions. To enable the analysis of such systems by PCH, the theoretical framework requires modification. Herein, we present an extension of the PCH analysis to systems where molecules exist in thin structures that are effectively two‐dimensional. The method, aptly called two‐dimensional photon counting histogram (2D PCH), recovers the number of fluorescent particles per unit area and their molecular brightness. Both theoretical background and experimental results are presented. The theory was tested using computer‐simulated and experimental 2D PCHs obtained from confocal experiments. We demonstrate that this modification of the theoretical framework provides a tool to extract data that reveal states of aggregation, surface photophysics, and reactivity.  相似文献   

17.
A fast, sensitive, and selective method for the determination of histamine in human urine samples by ultrahigh pressure liquid chromatography (LC) with fluorescence and mass spectrometry (MS) detection is investigated. A fluorescent reagent, 4-(1-pyrene) butyric acid N-hydroxysuccinimide ester was conjugated to the primary and secondary amino moieties of histamine. The structure of dipyrene-labeled histamine in human urine was determined by quadrupole time-of-flight MS with electospray ionization interface. The determination of the dipyrene derivative of histamine in urine samples was achieved within 3.9 min on an ultrahigh pressure LC Eclipse Zorbax XDB-C(18) column with 1.8 μm particle diameter. In this work, histamine separation was achieved significantly faster (3.9 min) with improved detection limit (signal-to-noise = 3) of 0.04 nM than 19.5 min with a detection limit of 0.183 nM as reported in a previous method.  相似文献   

18.
A high-discernment microflow cytometer with microweir structure   总被引:1,自引:0,他引:1  
Fu LM  Tsai CH  Lin CH 《Electrophoresis》2008,29(9):1874-1880
Using a simple and reliable isotropic wet etching process, we fabricated a microflow cytometer in which cells/particles are concentrated in the center of the sample stream using a 2-D hydrodynamic focusing technique and an microweir structure. Having focused the cells/particles, they are detected and counted using a LIF method. The experimental and numerical results confirm the effectiveness of the hydrodynamic sheath flows in squeezing the cells/particles into a narrow stream in the horizontal X-Y plane. Furthermore, it is shown numerically that the microweir structure results in the separation of the cells/particles in the vertical X-Z plane such that they pass through the detection region in a sequential fashion and can therefore be counted with a high degree of precision. The experimental results obtained using fluorescent polystyrene beads with diameters of 5 and 10 microm, respectively, confirm the suitability of the proposed device for microfluidic applications requiring the high-precision counting of particles or cells within a sample flow.  相似文献   

19.
Chang WS  Shang H  Perera RM  Lok SM  Sedlak D  Kuhn RJ  Lee GU 《The Analyst》2008,133(2):233-240
A magnetophoretic fluorescence sensor (MFS) has been developed to rapidly detect dengue virus in serum at a sensitivity that was approximately three orders of magnitude higher than conventional solid phase immunoassays. UV inactivated type 2 dengue virus was first reacted with a mixture of superparamagnetic and fluorescent microparticles functionalised with an anti-type 2 dengue virus monoclonal antibody in 10% fetal calf serum. The magnetic particles were separated from the serum based on their magnetophoretic mobility, and dengue virus was detected by the co-localization of magnetic and fluorescent particles at a specific point in the flow chamber. The MFS was capable of detecting dengue-2 virus at 10 PFU ml(-1) with a reaction time of 15 min. The MFS demonstrated a high specificity in the presence of yellow fever virus, a closely related flavivirus, which also did not produce any detectable increase in background signal. The improved performance of this technique appears to result from the rapid kinetics of the microparticle reaction, improved signal-to-noise ratio resulting from magnetophoretic separation, and rapid fluorescent particle detection. These results suggest that the MFS may be useful in early stage diagnosis of dengue infections, as well as other diseases.  相似文献   

20.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号