首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Increasingly, more food companies are relying on molecular methods, such as PCR, for pathogen detection due to their improved simplicity, sensitivity, and rapid time to results. This report describes the validation of a new Real-Time PCR method to detect Listeria monocytogenes in nine different food matrixes. The complete system consists of the MicroSEQ L. monocytogenes Detection Kit, sample preparation, the Applied Biosystems 7500 Fast Real-Time PCR instrument, and RapidFinder Express software. Two sample preparation methods were validated: the PrepSEQ Nucleic Acid extraction kit and the PrepSEQ Rapid Spin sample preparation kit. The test method was compared to the ISO 11290-1 reference method using an unpaired-study design to detect L. monocytogenes in roast beef, cured bacon, lox (smoked salmon), lettuce, whole cow's milk, dry infant formula, ice cream, salad dressing, and mayonnaise. The MicroSEQ L. monocytogenes Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all food matrixes when the samples were prepared using either of the two sample preparation methods. An independent validation confirmed these findings on smoked salmon and whole cow's milk. The MicroSEQ kit detected all 50 L. monocytogenes strains tested, and none of the 30 nontargeted bacteria strains.  相似文献   

2.
Listeria monocytogenes continues to be a threat to food safety in the United States despite a "zero tolerance" policy. When Listeria species are identified by standard cultural methods, confirmation of L. monocytogenes takes days to complete. RAPID'L.Mono agar, developed by Bio-Rad Laboratories, is a chromogenic medium that differentiates L. monocytogenes from other species of Listeria by a simple color change reaction. Differentiation is based on the specific detection of phosphatidylinositol phospholipase C activity, resulting in a blue colony, and the inability of L. monocytogenes to metabolize xylose, resulting in the absence of a yellow halo. Detection principles of standard method agars, Oxford and PALCAM, are based on the ability of all species of Listeria to hydrolyze esculin. Thus, all species of Listeria have similar colony morphology on these agars, making differentiation of pathogenic L. monocytogenes from other nonhuman pathogens difficult. RAPID'L.Mono agar has been validated with surimi, mixed salad, brie, and processed deli turkey because of the prevalence of L. monocytogenes in these foods. Sensitivity and specificity for this medium was determined to be 99.4 and 100%, respectively. Overall method agreement of RAPID'L.Mono with standard culture methods (U.S. Department of Agriculture/Food Safety and Inspection Service; U.S. Food and Drug Administration/Bacteriological Analytical Manual; and AOAC INTERNATIONAL) was excellent, with enrichment protocols 24 h shorter than those of standard methods.  相似文献   

3.
A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.  相似文献   

4.
A multilaboratory study was conducted to compare the automated BAX system and the standard cultural methods for detection of Listeria monocytogenes in foods. Six food types (frankfurters, soft cheese, smoked salmon, raw, ground beef, fresh radishes, and frozen peas) were analyzed by each method. For each food type, 3 inoculation levels were tested: high (average of 2 CFU/g), low (average of 0.2 CFU/g) and uninoculated controls. A total of 25 laboratories representing government and industry participated. Of the 2335 samples analyzed, 1109 were positive by the BAX system and 1115 were positive by the standard method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, except radishes, the BAX system performed as well as or better than the standard reference methods based on the Chi square results.  相似文献   

5.
Listeria monocytogenes is an important foodborne pathogen that must be controlled to ensure food safety. For the years 2003 and 2004, L. monocytogenes caused 20 deaths per 100 listeriosis cases and was responsible for most food recalls for pathogen contamination. The objective of this work was to develop a quantitative method to assess disinfectant activity against L. monocytogenes. Standard procedures for testing disinfectants against 3 bacteria are described in the AOAC Official Methods of Analysis as use-dilution methods. No standard methods are provided for L. monocytogenes. In this study, preliminary efficacy of a quaternary ammonium compound with hydroperoxide ion was determined for 25 bacterial strains. The zones of inhibition ranged from 7.0 to 12.5 mm, and the minimum inhibitory concentration ranged from 5 to 250 ppm. For final efficacy, stainless steel carriers were contaminated with L. monocytogenes and tested separately for 5, 10, and 15 min in disinfectant or phenol. After exposure, the carriers were placed into 2 series of D/E neutralization broth. For 3 replications with duplicate samples, the phenol coefficient was 3.3. This research presents a technique-sensitive method that provides quantitative data for comparison and analysis of disinfectant activity against L. monocytogenes.  相似文献   

6.
The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.  相似文献   

7.
A method was developed for the detection of Listeria monocytogenes in food. The method is based on real-time PCR using hydrolysis probes (5' Nuclease). This advanced PCR method was designed to reduce the time necessary to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the BIOTECON foodproof ShortPrep II Kit designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is carried out using the foodproof Listeria monocytogenes Detection Kit. The kit provides primers and hydrolysis probes for sequence-specific detection, convenient premixed reagents, and controls for reliable interpretation of results. For the internal comparison study, three different foods (soft cheese, coalfish, and smoked ham) were analyzed, chosen from the 15 food groups recommended by the AOAC Research Institute for detection of L. monocytogenes. From each food, 20 samples were inoculated with a low level (1-10 CFU/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, five nonspiked samples were prepared from each food. Depending on the matrix, the food samples were examined with the test kits and compared with the cultural methods according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture/Food Safety and Inspection Service Microbiology Laboratory Guidebook.  相似文献   

8.
A multilaboratory study was conducted to compare the VIDAS Listeria monocytogenes II (LMO2) immunoassay and the standard cultural methods for the detection of Listeria monocytogenes in foods. Five food types-vanilla ice cream, brie cheese, cooked roast beef, frozen green beans, and frozen tilapia fish-at 3 levels were analyzed by each method. A total of 26 laboratories representing government and industry participated. In this study, 1404 test portions were analyzed of which 1152 were used in the statistical analysis. There were 448 positive by the VIDAS LMO2 assay and 457 positive by the standard culture methods. A chi2 analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting chi2 value, 0.36, indicates that overall, there are no statistical differences between the VIDAS LMO2 assay and the standard methods at the 5% level of significance.  相似文献   

9.
C Wolf  D Behrendt  B Conradi  B Jülicher 《The Analyst》1998,123(12):2719-2723
Two Beta-Agonist Interlaboratory Studies, 5/96 and 11/97, were designed and evaluated according to the International Harmonised Protocol for the Proficiency Testing of (Chemical) Analytical Laboratories (ISO/REMCO N 280) jointly elaborated by ISO, IUPAC and AOAC. In the sense of proficiency testing, interlaboratory studies are part of external quality assurance systems. The Beta-Agonist Interlaboratory Studies 5/96 and 11/97 were intended to offer laboratories in the EU Member States an opportunity to check objectively their routine methods for the detection of beta-agonists and to demonstrate the reliability of their analytical results; 48 and 44 laboratories, respectively, all involved in official residue control, participated in the studies. Irrespective of the large number of satisfactory results achieved at higher concentration levels according to the z-score evaluation, the number of false negative results is still unsatisfactory. The results of both Beta-Agonist Interlaboratory Studies confirmed that comparability of analytical results is not yet ensured within the European residue control system.  相似文献   

10.
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.  相似文献   

11.
The new BAX System PCR Assay for Genus Listeria 24E was evaluated for detecting Listeria spp. in frankfurters, spinach, cooked shrimp, queso fresco cheese, and on stainless steel surfaces with a single-stage enrichment in BAX System 24 Listeria Enrichment Broth (24 LEB). Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the U.S. Food and Drug Administration's Bacteriological Analytical Manual and the U.S. Department of Agriculture-Food Safety and Inspection Service culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined, within the range of deviations from specified parameters examined, affect the performance of the assay.  相似文献   

12.
A one-step, recovery-enrichment broth, optimized Penn State University (oPSU) broth, was developed to consistently detect low levels of injured and uninjured Listeria monocytogenes cells in ready-to-eat foods. The oPSU broth contains special selective agents that inhibit growth of background flora without inhibiting recovery of injured Listeria cells. After recovery in the anaerobic section of oPSU broth, Listeria cells migrated to the surface, forming a black zone. This migration separated viable from nonviable cells and the food matrix, thereby reducing inhibitors that prevent detection by molecular methods. The high Listeria-to-background ratio in the black zone resulted in consistent detection of low levels of L. monocytogenes in pasteurized foods by both cultural and molecular methods, and greatly reduced both false-negative and false-positive results. oPSU broth does not require transfer to a secondary enrichment broth, making it less laborious and less subject to external contamination than 2-step enrichment protocols. Addition of 150mM D-serine prevented germination of Bacillus spores, but not the growth of vegetative cells. Replacement of D-serine with 12 mg/L acriflavin inhibited growth of vegetative cells of Bacillus spp. without inhibiting recovery of injured Listeria cells. oPSU broth may allow consistent detection of low levels of injured and uninjured cells of L. monocytogenes in pasteurized foods containing various background microflora.  相似文献   

13.
基于分子信标荧光纳米探针的李斯特菌DNA均相检测方法   总被引:1,自引:0,他引:1  
王周平  徐欢  段诺  吴佳  叶菁  乐国伟 《化学学报》2010,68(9):909-916
基于分子信标(MB)识别和荧光纳米粒子探针技术,建立了均相体系中李斯特菌目标DNA的高灵敏检测新方法.首先以羊抗人免疫球蛋白(IgG)标记的异硫氰酸荧光素(FITC)为核材料,成功制备了FITC-IgG@SiO2核壳荧光纳米粒子,有效防止了传统方法中采用单一FITC制备纳米颗粒时泄露严重的问题.随后以FITC-IgG@SiO2荧光纳米粒子和纳米金分别标记单核细胞增生李斯特菌序列特异性分子信标探针5'端和3'端,成功构建了单核细胞增生李斯特菌序列特异性分子信标荧光纳米探针.在实验优化条件下,α(令α=F/F0,F代表MB和目标DNA杂交以后的荧光强度,F0代表MB完全闭合时的荧光强度)与目标DNA浓度在1~200pmol/L浓度范围内呈良好的线性关系,检出下限为0.3pmol/L,相对标准偏差为2.6%(50pmol/L,n=11).将该方法应用于食品样品中单核细胞增生李斯特菌的检测,结果与国标法一致.  相似文献   

14.
In a multilaboratory study, the effectiveness of an alternative method for rapid screening of Listeria species compared to traditional reference methods was demonstrated in a variety of food products. A collaborative study was conducted to compare the VIDAS Listeria species Xpress (LSX) method and the standard cultural methods for the detection of Listeria species in foods. Six food types were tested: vanilla ice cream, cheddar cheese, raw ground beef, frozen green beans, deli turkey, and cooked shrimp. Each food, inoculated with a different Listeria strain at two levels and uninoculated test portions, was analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study 1134 tests were analyzed in the statistical analysis. There were 490 positives by the VIDAS LSX method using the sample boiling step, 483 positives by the VIDAS LSX method using the Heat and Go system, and 439 positives by the standard culture methods. Overall, the Chi-square result for the VIDAS LSX method with boiling for all foods was 7.25, indicating a significant statistical difference between the VIDAS method and the standard methods at the 5% confidence. For the VIDAS LSX method with the Heat and Go system, the Chi-square result for all foods was 5.37, indicating a significant statistical difference between the VIDAS LSX assay with the Heat and Go system and the standard methods at the 5% level of significance. In both cases, the VIDAS method was more sensitive than the standard methods. The LSX method detects Listeria species in foods with negative or presumptive positive results in a minimum of 30 h compared to at least 5 days for the cultural methods. Based on the results of this collaborative study, it is recommended that the VIDAS LSX method be adopted as an AOAC Official Method for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry.  相似文献   

15.
A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay. Five food types--brie cheese, vanilla ice cream, frozen green beans, frozen raw tilapia fish, and cooked roast beef--at 3 inoculation levels, were analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study, 1206 test portions were tested, of which 1170 were used in the statistical analysis. There were 433 positive by the VIDAS LIS assay and 396 positive by the standard culture methods. A Chi-square analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting average Chi square analysis, 0.42, indicated that, overall, there are no statistical differences between the VIDAS LIS assay and the standard methods at the 5% level of significance.  相似文献   

16.
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.  相似文献   

17.
A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.  相似文献   

18.
The proficiency testing program in food microbiology (Réseau d'Analyses et d'Echanges en Microbiologie des Aliments; RAEMA), created in 1988, currently includes 440 participating laboratories. The program establishes proficiency in detection of Salmonella and Listeria monocytogenes, as well as quantitation of aerobic microorganisms, Enterobacteriaceae, coliforms, Escherichia coli, Clostridium perfringens, coagulase-positive Staphylococcus, and Listeria monocytogenes. Twice a year, 5 test samples are sent to participants to assess their precision and trueness for enumeration and detection of microorganisms. Results show an increasing involvement of food microbiology laboratories in quality assurance programs and use of standard and validated analytical methods. However, the percentage of laboratories obtaining questionable and unsatisfactory microbiological results remains relatively constant.  相似文献   

19.
A review is presented of nucleic acid amplification-based methodology, specifically polymerase chain reaction (PCR)-based assays, for the detection of Listeria monocytogenes in food and environmental samples. Until recently, developmental challenges including poor sensitivity, due in part to reaction inhibition by components of the sample matrix, and the potential for false-positive reactions have limited routine application of PCR-based screening assays. Commercial assays address these challenges while offering convenient, standardized protocols, a high level of automation, and results within 2 days after the sampling date. Although sample enrichment is necessary to achieve desired detection limits, continued efforts toward template purification will facilitate the development of assays offering real-time, quantitative results. The development of ribonucleic acid (RNA) amplification-based assays may increase in importance, particularly if end-product testing is prioritized by regulatory agencies, as messenger RNA appears to serve as an accurate indicator of cell viability. Further, the increase in target copy number may improve assay sensitivity. PCR-based screening methods offer efficient, reliable results and are ideal for monitoring the presence of L. monocytogenes in foods and in the food processing environment.  相似文献   

20.
An independent laboratory study of the BAX for Screening/E. coli O157:H7 kit was conducted at the National Food Laboratory, Inc., Dublin, CA, to complete AOAC Performance Tested Method certification. The BAX system kit was compared with the BAM culture method and a modified BAM culture method for detection of E. coli O157:H7 in ground beef. The BAX system kit detected the target organism at levels approximately 10-fold lower than those that gave positive BAM results. This study validated product claims, and Performance Tested Method status was granted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号