The methodology for obtaining two- and three-dimensional magnetic resonance images by using azimuthally symmetric dipolar magnetic fields from ferromagnetic spheres is described. We utilize the symmetric property of a geometric sphere in the presence of a large externally applied magnetic field to demonstrate that a complete two- or three-dimensional structured rendering of a sample can be obtained without the motion of the sample relative to the sphere. Sequential positioning of the integrated sample-sphere system in an external magnetic field at various angular orientations provides all the required imaging slices for successful computerized tomographic image reconstruction. The elimination of the requirement to scan the sample relative to the ferromagnetic tip in this imaging protocol is a potentially valuable simplification compared to previous scanning probe magnetic resonance imaging proposals.  相似文献   

2.
The enhanced spin polarization produced by optical pumping of gaseous rubidium/xenon samples has made possible a number of recent experiments in nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI). Here we report MRI of laser-polarized xenon in the solid phase at low temperature. Due to the high xenon density in the solid phase and the enhanced spin polarization, it is possible to achieve high intensity and spatial resolution of the image. Signals were observed from xenon films solidified onto the glass container walls and not from an enclosed chili pepper.  相似文献   

3.
Growing interest in magnetic resonance imaging (MRI) at ultra-low magnetic fields (ULF, approximately muT fields) has been motivated by several advantages over its counterparts at higher magnetic fields. These include narrow line widths, the possibility of novel imaging schemes, reduced imaging artifacts from susceptibility variations within a sample, and reduced system cost and complexity. In addition, ULF NMR/MRI with superconducting quantum interference devices is compatible with simultaneous measurements of biomagnetic signals, a capability conventional systems cannot offer. Acquisition of MRI at ULF must, however, account for concomitant gradients that would otherwise result in severe image distortions. In this paper, we introduce the general theoretical framework that describes concomitant gradients, explain why such gradients are more problematic at low field, and present possible approaches to correct for these unavoidable gradients in the context of a non-slice-selective MRI protocol.  相似文献   

4.
The basic concepts necessary to understand the physical basis of NMR imaging are presented in this didactic article. It is intended as a starting point for the radiologist or medical physicist who is addressing the topic of NMR for the first time. The basis of the NMR phenomena is described with introduction of the concepts of magnetic moment, magnetic fields, magnetic resonance, net magnetic moment of a sample, NMR excitation and NMR emission. The equipment necessary to observe these NMR properties of matter is summarized as well as the procedures for basic pulsed NMR experiments. The physical concepts for spatial localization of NMR emissions are introduced with physical analogies to stringed musical instruments. Several alternative imaging modalities are compared with greatest emphasis on the inversion recovery technique which yields images weighted by tissue T1 values. The six subsystems of an NMR imaging device (primary magnet, computer, radio equipment, magnetic gradient, data storage and display subsystems) are described in an overview fashion. The paper is followed by a series of study questions to test the reader's comprehension of basic NMR imaging concepts.  相似文献   

5.
Interest in nuclear magnetic resonance measurements at ultra-low magnetic fields (ULF, approximately microT fields) has been motivated by various benefits and novel applications including narrow NMR peak-width, negligible susceptibility artifacts, imaging of samples inside metal containers, and possibility of directly imaging neuronal currents. ULF NMR/MRI is also compatible with simultaneous measurements of biomagnetic signals. However the most widely used technique in ULF NMR-prepolarization at high field and measurement at lower field-results in large transient signals which distort the free induction decay signal. This is especially severe for the measurement of signals from samples and materials with short T1 time. We have devised an approach that largely cancels the transient signals. The technique was successfully used to measure NMR signals from liquids and gases with T1 in the range 1-4 ms.  相似文献   

6.
Diffusion-weighted echo-planar magnetic resonance imaging is potentially of great importance as a diagnostic imaging tool; however, the technique currently suffers a number of limitations, including the image distortion caused by the eddy current induced fields when the diffusion-weighting magnetic field gradient pulses are applied. The distortions cause mis-registration between images with different diffusion-weighting, that then results in artifacts in quantitative diffusion images. A method is presented to measure the magnetic fields generated from the eddy currents for each of three orthogonal gradient pulse vectors, and then to use these to ascertain the image distortion that occurs in subsequent diffusion-weighted images with arbitrary gradient pulse vector amplitude and direction, and image plane orientation. The image distortion can then be reversed. Both temporal and spatial dependence of the residual eddy current induced fields are included in the analysis. Image distortion was substantially reduced by the correction scheme, for arbitrary slice position and angulation. This method of correction is unaffected by the changes in image contrast that occur due to diffusion weighting, and does not need any additional scanning time during the patient scan. It is particularly suitable for use with single-shot echo planar imaging.  相似文献   

7.
An analytic solution is given for the electromagnetic problem of a lossy dielectric cylinder of infinite length, irradiated by a circularly polarized radiofrequency (RF) magnetic field; the NMR-active components of the field inside the cylinder are projected out by transforming the RF Hamiltonian to the rotating frame and retaining only those terms independent of time; it is noted that the resulting cartesian field components are required to be real. The squared magnitude of the NMR-active fields are then used to calculate the gradient-recalled images of the cylinder, for small tip angles of the magnetization; and the result is shown to predict almost quantitatively the intensity patterns of experimental proton images at 3.0 and 4.0T, in a cylindrical phantom of radius 9.25cm, filled with 0.05M aqueous NaCl. In particular, the artifactual brightening at the center of the recorded image is convincingly reproduced in a simulation, whose underlying model excludes wave propagation along the direction of the cylinder axis. Formation of the artifact is explained in terms of the focussing of the RF magnetic field at the center of the cylinder, as illustrated by contour plots showing the time evolution of the rotating flux. An extended electromagnetic model--having the dielectric cylinder enclosed in a long, shielded volume resonator (e.g., of bird cage type)--is then sketched. The mathematical details appear in Appendix A; and the simulated images are shown to be virtually indistinguishable from those of the simpler original model. The theory of the Q, or quality factor, of the dielectric cylinder--considered itself as a resonant object--is developed for the enclosed cylinder model, where flux containment by the shield permits an unambiguous treatment of both the stored energy and the radiative losses. This is extended to treat the Q of a lossy dielectric sphere without shielding. Further plots of flux contours are given for the sphere, excited at 208 MHz with a uniform circularly polarized field, as well as by a surface coil, and for the enclosed cylinder in the range 140-160 MHz. It is then argued that the center brightening artifacts in magnetic resonance images are due to the underdamped dielectric resonance of the sample, i.e., at Q >0.5, while the overdamped condition, Q < 0.5, leads to exclusion of flux from the center, i.e., to the classic skin effect. The term "dielectric resonance" is shown to require careful interpretation for mixed-mode excitation, such as occurs with a surface coil. An extended reciprocity formula for NMR reception, valid for an arbitrary electromagnetic Green's function, is also given in Appendix B.  相似文献   

8.
该文以超导量子干涉元件研究光激发氦三极化气体的低磁场磁共振与造影术.使用圆偏极化雷色光将氦三气体极化,超导量子干涉元件磁共振与造影之测量是以磁通耦合方式来进行,超导量子干涉元件是用铋锶钙铜氧高溫超导罐来隔离环境噪音.此方法测得的磁共振信号与影像相较于直接将样品置于杜瓦瓶下方有较高的信噪比,当样品无法靠近感测元件时,此装置具高信噪比特色.磁通耦合方式的超导量子干涉元件低磁场磁共振与造影术及其氦三极化气体的肺部造影在学术与应用上是相当有趣.  相似文献   

9.
Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8–298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as well, thus enabling higher image resolutions. On the other hand, MRI is possible also at ultra-low magnetic fields, as was shown by different groups. The goal of our development was to reach a Larmor frequency range of the low-field MRI system corresponding to the frequency range of human brain activities ranging from near zero-frequency (near-DC) to over 1 kHz. Here, first 2D MRI images of phantoms taken at Larmor frequencies of 100 Hz and 731 Hz will be shown and discussed. These frequencies are examples of brain activity triggered by electrostimulation of the median nerve. The method will allow the magnetic fields of the brain currents to influence the magnetic resonance image, and thus lead to a direct functional imaging modality of neuronal currents.  相似文献   

10.
High pressure measurements in most scientific fields rely on metal vessels given the superior tensile strength of metals. We introduce high pressure magnetic resonance imaging (MRI) measurements with metallic vessels. The developed MRI compatible metallic pressure vessel concept is very general in application. Macroscopic physical systems are now amenable to spatially resolved nuclear magnetic resonance (NMR) study at variable pressure and temperature. Metallic pressure vessels not only provide inherently high tensile strengths and efficient temperature control, they also permit optimization of the MRI RF probe sensitivity. An MRI compatible pressure vessel is demonstrated with a rock core holder fabricated using non-magnetic stainless steel. Water flooding through a porous rock under pressure is shown as an example of its applications. High pressure NMR spectroscopy plays an indispensable role in several science fields. This work will open new vistas of study for high pressure material science MRI and MR.  相似文献   

11.
High-resolution imaging techniques using noninvasive modalities such as magnetic resonance (MR) imaging are being pursued as in vivo cancer screening techniques in an attempt to eliminate the invasive nature of surgical biopsy. When acquiring high-resolution MR images for tissue screening, image fields of view have in the past been limited by the matrix sizes available in conventional MR scanners. We present here a technique that uses aliasing to produce high resolution images with larger matrix sizes than are currently available. The image is allowed to alias in both the frequency encoding and phase encoding dimensions, and the individual, aliased fields of view are recovered by Hadamard encoding methods. These fields may then be tiled to obtain a composite image with high spatial resolution and a large field of view. The technique is demonstrated using two-dimensional and three-dimensional in vivo imaging of the human brain and breast.  相似文献   

12.
Accelerating the imaging speed without sacrificing image structures plays an important role in magnetic resonance imaging. Under-sampling the k-space data and reconstructing the image with sparsity constraint is one efficient way to reduce the data acquisition time. However, achieving high acceleration factor is challenging since image structures may be lost or blurred when the acquired information is not sufficient. Therefore, incorporating extra knowledge to improve image reconstruction is expected for highly accelerated imaging. Fortunately, multi-contrast images in the same region of interest are usually acquired in magnetic resonance imaging protocols. In this work, we propose a new approach to reconstruct magnetic resonance images by learning the prior knowledge from these multi-contrast images with graph-based wavelet representations. We further formulate the reconstruction as a bi-level optimization problem to allow misalignment between these images. Experiments on realistic imaging datasets demonstrate that the proposed approach improves the image reconstruction significantly and is practical for real world application since patients are unnecessarily to stay still during successive reference image scans.  相似文献   

13.
Recently the capabilities of single sided nuclear magnetic resonance (NMR) devices have been extended towards three-dimensional imaging. This paper details the use of a magnetic field sweep coil to obtain spatial resolution in the plane normal to the surface of a hand-held NMR device-the NMR-Mobile Universal Surface Explorer (MOUSE). One-dimensional depth profiles can be recorded by varying the current in the sweep coils. Preliminary results from multi-layer rubber and glass sample phantoms demonstrate a sample penetration depth of 7 mm. Two-dimensional images were acquired via the inclusion of phase encoding coils. Non-destructive cross-sectional images of small rubber phantoms were successfully recorded.  相似文献   

14.
Parallel MRI at microtesla fields   总被引:2,自引:2,他引:0  
Parallel imaging techniques have been widely used in high-field magnetic resonance imaging (MRI). Multiple receiver coils have been shown to improve image quality and allow accelerated image acquisition. Magnetic resonance imaging at ultra-low fields (ULF MRI) is a new imaging approach that uses SQUID (superconducting quantum interference device) sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at microtesla-range measurement fields. In this work, parallel imaging at microtesla fields is systematically studied for the first time. A seven-channel SQUID system, designed for both ULF MRI and magnetoencephalography (MEG), is used to acquire 3D images of a human hand, as well as 2D images of a large water phantom. The imaging is performed at 46 mu T measurement field with pre-polarization at 40 mT. It is shown how the use of seven channels increases imaging field of view and improves signal-to-noise ratio for the hand images. A simple procedure for approximate correction of concomitant gradient artifacts is described. Noise propagation is analyzed experimentally, and the main source of correlated noise is identified. Accelerated imaging based on one-dimensional undersampling and 1D SENSE (sensitivity encoding) image reconstruction is studied in the case of the 2D phantom. Actual threefold imaging acceleration in comparison to single-average fully encoded Fourier imaging is demonstrated. These results show that parallel imaging methods are efficient in ULF MRI, and that imaging performance of SQUID-based instruments improves substantially as the number of channels is increased.  相似文献   

15.
This article reports experimental investigations on the use of RF resonators for continuous-wave electron paramagnetic resonance (cw-EPR) and proton nuclear magnetic resonance (NMR) imaging. We developed a composite resonator system with multi-coil parallel-gap resonators for co-registration EPR/NMR imaging. The resonance frequencies of each resonator were 21.8MHz for NMR and 670MHz for EPR. A smaller resonator (22mm in diameter) for use in EPR was placed coaxially in a larger resonator (40mm in diameter) for use in NMR. RF magnetic fields in the composite resonator system were visualized by measuring a homogeneous 4-hydroxy-2,2,6,6-tetramethyl-piperidinooxy (4-hydroxy-TEMPO) solution in a test tube. A phantom of five tubes containing distilled water and 4-hydroxy-TEMPO solution was also measured to demonstrate the potential usefulness of this composite resonator system in biomedical science. An image of unpaired electrons was obtained for 4-hydroxy-TEMPO in three tubes, and was successfully mapped on the proton image for five tubes. Technical problems in the implementation of a composite resonator system are discussed with regard to co-registration EPR/NMR imaging for animal experiments.  相似文献   

16.
NMR images of laser polarized 3He gas were obtained at 21 G using a simple, homebuilt instrument. At such low fields magnetic resonance imaging (MRI) of thermally polarized samples (e.g., water) is not practical. Low-field noble gas MRI has novel scientific, engineering, and medical applications. Examples include portable systems for diagnosis of lung disease, as well as imaging of voids in porous media and within metallic systems.  相似文献   

17.
Solving the problem of concomitant gradients in ultra-low-field MRI   总被引:1,自引:0,他引:1  
In ultra-low-field magnetic resonance imaging (ULF MRI), spin precession is detected typically in magnetic fields of the order of 10-100 μT. As in conventional high-field MRI, the spatial origin of the signals can be encoded by superposing gradient fields on a homogeneous main field. However, because the main field is weak, gradient field amplitudes become comparable to it. In this case, the concomitant gradients forced by Maxwell's equations cause the assumption of linearly varying field gradients to fail. Thus, image reconstruction with Fourier transformation would produce severe image artifacts. We propose a direct linear inversion (DLI) method to reconstruct images without limiting assumptions about the gradient fields. We compare the quality of the images obtained using the proposed reconstruction method and the Fourier reconstruction. With simulations, we show how the reconstruction errors of the methods depend on the strengths of the concomitant gradients. The proposed approach produces nearly distortion-free images even when the main field reaches zero.  相似文献   

18.
While magnetic resonance images essentially contain a map of the both circularly polarized components of the RF transverse magnetic fields (B(1) field), the thermal heat and electromagnetic power deposition is generated by the associated electric fields. Measurement of electric field distributions/intensities across a sample yields an indirect indication of possible cause of heating within the sample and potentially enables the detection of "hot spots," which can be present within inhomogeneous radiofrequency (RF) fields, such as the case with magnetic resonance imaging at high field strength. As a result, establishing a valid technique for direct measurements of the electric field and its correlation, obtained using computational electromagnetics, is essential in assessing (1) the safety of the RF coil designs and (2) the validity of the calculations. In this work, a probe was built and used to measure the transverse electric field (E(1) field) distributions within an empty 8 T (tuned to 340 MHz) RF head coil and within a saline water phantom loaded in the same coil. The measured E(1) field distributions were favorably compared to the distributions obtained utilizing a finite difference time domain in-house package.  相似文献   

19.
Mechanical rotation of a sample at 54.7 degrees with respect to the static magnetic field, so-called magic-angle spinning (MAS), is currently a routine procedure in nuclear magnetic resonance (NMR). The technique enhances the spectral resolution by averaging away anisotropic spin interactions thereby producing isotropic-like spectra with resolved chemical shifts and scalar couplings. It should be possible to induce similar effects in a static sample if the direction of the magnetic field is varied, e.g., magic-angle rotation of the B0 field (B0-MAS). Here, this principle is experimentally demonstrated in a static sample of solid hyperpolarized xenon at approximately 3.4 mT. By extension to moderately high fields, it is possible to foresee interesting applications in situations where physical manipulation of the sample is inconvenient or impossible. Such situations are expected to arise in many cases from materials to biomedicine and are particularly relevant to the novel approach of ex situ NMR spectroscopy and imaging.  相似文献   

20.
When cutaneous fat layers are in the ultrasound imaging region, the phase aberration caused by the fat layers induce image distortion as well as spatial resolution degradation. The phase aberration may complicate clinical procedures particularly when ultrasound imaging is employed for spatial positioning of medical devices like a biopsy needle or HIFU. To compensate the fat layer effects more precisely in beamforming, an inclined-fat-layer model has been established from the magnetic resonance images of the same imaging region as in the ultrasound scanning. We have verified utility of the fat layer model by taking images of a metal needle put into an inclined-fat-layer mimicking phantom. The ultrasound images taken with a 128-element linear phase array operating at 6 MHz have shown better resolution and less distortion when receive beamforming was performed with the phase delay data derived from the inclined-fat-layer model.  相似文献   