首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present research discusses the structure stabilizing and protecting effects of Ni2+ against suicide-peroxide inactivation of horseradish peroxidase (HRP). Suicide inactivation of HRP by hydrogen peroxide (3 mM) was monitored by measuring change in the absorbance of the colored product (tetraguaiacol) of the catalytic reaction cycle at 470 nm. Progress curves of the catalytic reaction cycle were obtained at 27 °C, phosphate buffer (5 mM), pH 7.0. The corresponding kinetic parameters (e.g., initial enzyme activity (αo) and the apparent rate constant (ki) of suicide inactivation of HRP by peroxide) were evaluated using a kinetic equation derived in this study. Comparative activatory and inhibitory effects of Ni2+ on the kinetics of suicide-peroxide inactivation of HRP are discussed.  相似文献   

2.
The existence of homoserine lactone in Pisum sativum seedlings is demonstrated. L-Homoserine lactone reacts with hydroxylamine, at neutral or alkaline pH, to form homoserine hydroxamic acid. Procedures are described for preparing L-homoserine lactone and L-homoserine hydroxamic acid. The hydroxamic acid yields a color with maximum absorbance at 492 nm with Fe3+ in 0.25 N HCl. This reaction permitted assay for total homoserine and homoserine lactone. Six-day old Pisum sativum seedlings, with cotyledons removed, were extracted with 90% ethanol. Evaporation of the ethanol and addition of Na2SO4 solution and toluene and centrifugation removed protein lipids and esters. After clarification with activated charcoal, homoserine lactone content was estimated by reaction with NH2OH and Fe3+ reagents. For total homoserine, protein precipitation was with 2 N HCl and toluene. Evaporation to dryness at 60 °C under vacuum converted all homoserine to the lactone. The values found for total homoserine (μmols/g, wet weight) and preformed lactone (%) with the various growth media used were as follows: nitrate 87.4 (14.7%), NH2OH 75.2 (6.3%), water 70.5 (7.9%), urea 56.4 (18.9%). Acetic anhydride added to homoserine hydroxamic acid forms acetohydroxamic acid, which yields a color with maximum absorbance at 505 nm with Fe3+. This color reaction is seven times as sensitive as the reaction of Fe3+ with homoserine hydroxamic acid itself.  相似文献   

3.
A commercially-available sulfonphthalein derivative was demonstrated to be a chemodosimeter for Fe2+ and its sensing behavior was further investigated by UV-vis spectroscopy in aqueous media under the optimum conditions. In the presence of chlorophenol red (CPR) and H2O2, the absorption maximum at 435 nm decreased upon addition of Fe2+, resulting in a significant color change of the CPR solution from yellow to colorless. The chemosensor system did not show significant responses to a series of other metal ions including Al3+, Zn2+, Cd2+, Hg2+, Mn2+, Co2+, Fe3+, Ni2+, Cu2+, La3+, Ce4+, Th4+, Pd2+, Pb2+, Sb3+, Cr3+, Au3+, Ag+, Nd3+, Sm3+, alkali and alkaline earth metal cations, allowing for highly selective naked-eye detection of Fe2+. Quantitative analysis was carried out kinetically for practicable the Fe2+ assay when either fixed time method or the initial rate method was applied. When the detecting time was set, the decrease of absorbance signal was linear with Fe2+ concentration in the range of 0 to 7.50 × 10?5 mol L?1 and the regression equation was ΔA = 0.00759 + 0.00593C Fe with a correlation coefficient r = 0.9953. The chemodosimetric system has employed an irreversible Fenton reagent-promoted oxidation of the CPR free chromophore and the hydroxyl radicals were generated in the presence of both Fe2+ and hydrogen peroxide. The mechanistic interpretation of the signaling process was partially confirmed by the radical scavenging experiment and the FT-IR analysis of the intermediates formed at different reaction periods.  相似文献   

4.
The present study reports simultaneous mineralisation and biodetoxification of Ponceau S (3-hydroxy-4-(2-sulfo-4-[4-sulfophenylazo]phenylazo)-2,7-naphthalenedisulfonic acid sodium salt), an azo dye, by UV light assisted oxidation with hydroxyl and sulfate radicals. Metal ion catalysts used in the work were: Fe2+ and Ag+, and the oxidants used were: hydrogen peroxide and S2O82?. Strategies adopted to make the processes environmentally benign and economically viable by achieving maximum mineralisation in the shortest possible time are described. Mineralisation efficiency (Em) of various systems was found to follow the order: Em(Fe2+/H2O2/UV) > Em(Fe2+/S2O82?/UV) > Em(Ag+/H2O2/UV) ≈ Em(Ag+/S2O82?/UV). Thus, Fe2+ and HP are the most suitable metal ion catalyst and oxidant respectively, showing higher efficiency at pH 3 followed by that at pH 6.6. It is possible to enhance the Fe2+/H2O2/UV process electrical energy efficiency by maintaining the concentration of Fe at either 0.05 mM or 0.03 mM and that of the oxidant at 2.5 mM. The bioassay study revealed that the Fe2+/S2O82?/UV process biodetoxification efficiency is higher at pH 3 (93.7 %) followed by that at pH 6.6 (80.1 %) at the concentration of Fe 2+ and S2O82? of 0.03 mM and 2.5 mM, respectively. Thus, not only the concentration of Fe2+, but also the nature of the oxidant and pH play an important role in the biodetoxification process and S2O82? possesses higher biodetoxification efficiency than H2O2.  相似文献   

5.
Abstract— Calf thymus DNA was irradiated with low-intensity UVA (main output at 365 nm, 2 mW cm?2 or 36 kj m 2 for 30 min), and the role of metal ions, hydrogen peroxide and reactive oxygen species (ROS) was examined. DNA damage was measured as thiobarbituric acid-reactive substances (possibly from degradation of deoxyribose) and as changes in ethidium bromide-DNA fluorescence due to unwinding from strand breaks. Under the present experimental conditions, UVA alone or in the presence of H202 had no effect on DNA but slightly enhanced the damage by iron/EDTA. Ultraviolet A strongly enhanced DNA damage (ca four- to five-fold) by the Fenton reaction system (50 μM Fe2+/100 μM EDTA + 0.5 mM H202). The results suggest that the Fenton reaction system was “photosensitized” to damage DNA by low-intensity UVA radiation. The enhanced damage by UVA was attributed in part to the reduction of Fe3+ to Fe2+. Ultraviolet A had no effect when iron (ferric or ferrous) ions were replaced by Cu2+, Zn2+, Mn2+ or Cd2+. The ROS involved in the UVA-enhanced damage to DNA by the Fenton reagents were OH and, to a lesser extent, superoxide anions. The UVA-potentiated DNA damage by the Fenton reaction system was then used to examine the protective effect of para-aminobenzoate (PABA), a UVB-absorbing sunscreen that protects against photocarcinogenesis in hairless mice. The results show that PABA and mannitol dose-dependently inhibited the damage with concentrations required for 50% inhibition at 0.1 mM and 3 mM, respectively. The protection by PABA was attributed to its radical-scavenging ability because PABA does not absorb light in the UVA region. These findings may be relevant to the biological damage by UVA and suggest that PABA is useful in protection against photocarcinogenesis by wide-range UV radiation.  相似文献   

6.
Fe3O4 nanoparticles were deposited on sheets of graphene oxide (GO) by a precipitation method, and glucose oxidase (GOx) was then immobilized on this material to produce a GOx/Fe3O4/GO magnetic nanocomposite containing crosslinked enzyme clusters. The 3-component composite functions as a binary enzyme that was employed in a photometric method for the determination of glucose and hydrogen peroxide where the GOx/Fe3O4/GO nanoparticles cause the generation of H2O2 which, in turn, oxidize the substrate N,N-diethyl-p-phenylenediamine to form a purple product with an absorption maximum at 550 nm. The absorbance at 550 nm can be correlated to the concentration of glucose and/or hydrogen peroxide. Under optimized conditions, the calibration plot is linear in the 0.5 to 600 μM glucose concentration range, and the detection limit is 0.2 μM. The respective plot for H2O2 ranges from 0.1 to 10 μM, and the detection limit is 0.04 μM. The method was successfully applied to the determination of glucose in human serum samples. The GOx/Fe3O4/GO nanoparticles are reusable.
Figure
A one-step spectrophotometric method for the detection of glucose and/or H2O2 was developed by using GOx immobilized Fe3O4/GO MNPs as a bienzyme system and DPD as a substrate.  相似文献   

7.
Hydrogen peroxide in pickling baths for copper and copper alloys can be determined by linear sweep voltammetry with a glassy carbon electrode. The oxidation mechanism changes around 0.15 M H2O2. Catalytic decomposition was found to be much smaller at glassy carbon electrodes than at platinum electrodes. An almost linear calibration curve was obtained up to 60 mM H2O2. Interferences from Cu2+, Zn2+, Ni2+, Al3+, Fe3+ and Pb2+ as well as from the stabilizers were small. All measurements were made in sulphuric acid solutions.  相似文献   

8.
Degradation of acridine orange (AO) in aqueous solution by Fenton's reagent (Fe2+ and H2O2) was investigated. The effects of different reaction parameters such as initial AO concentration, pH value of solution, ferrous concentration, hydrogen peroxide concentration, and the presence of chloride ion on the oxidative degradation of AO were investigated. Under optimum conditions, 2 mM H2O2, 0.4 mM Fe2+ and pH 3.0, the initial 0.2 mM AO solution was reduced by 95.8% within 10 min. The primary intermediates of the degradation reaction of AO were identified. The analytical results indicated that the N‐de‐methylation degradation of AO dye took place in a stepwise manner to yield mono‐, di‐, tri‐, and tetra‐N‐de‐methylated AO species generated during the Fenton process. The probable degradation pathways were proposed and discussed.  相似文献   

9.
New chelating oligo(ether-amide)s (CA-PE)s containing chelidamic acid residues in the main chain were prepared by reacting chelidamic acid with Jeffamines ED® in the presence of N,N-dicyclohexylcarbodiimide and 4-dimethylaminopyridine. A mixture of products having one or two polyether sequences with chelidamate end-groups was obtained. It was found spectrophotometrically that CA-PE polymers formed a complex with Fe3+ at pH 3-6 having a maximum absorbance in the 472-495 nm range. Fe3+ ion complexes of CA-PE were water soluble, except Fe3+-CA-PE600. The stoichiometric ratio between chelidamic acid residues of oligo(ether-amide)s CA-PE and Fe3+ ions was found to be 2 at pH 5 by the method of shift of equilibrium. A hydroxypyridine structure of the chelidamic acid residues in the complex was suggested.  相似文献   

10.
Methods for the detectionn of metal cations under acidic conditions, near PH 2, in capillary electrophoresis (CE) were investigatged. Conditions for direct UV detection of UV absorbing metal cations such as Cr3+, Cu2+, Fe3+, UO22+, VO2+, and VO2+ were established With aqueous HCl or HClO4 as the electroyte carrier. The speciation of vanadium(IV) and vanadium(V) at PH 2.3 by CE was achieved with direct detection at 185 nm. With the strong absorbance at 185 nm, no complexation was needed to detect the metal cations. An indirect UV detrection scheme for acidic conditions was also investigated. Several background carrier electolytes (BCES) were studied including 4-methylbenzylamince, nicontinamide, pyridazine, guanidine, 3-picoline, and chromium (III) to determine their effectivencess under very acidic conditions. The efect of ioni c surfactants and the nonionic surfactant, Trition X-100, on the peak heights and N Values was also studied.  相似文献   

11.
In this work, green fluorescent carbon dots with a high relative quantum yield of 74.13% were synthesized by using one-pot hydrothermal hydrolysis of m-phenylenediamine (mPD) and PEG 1500 in H2SO4 solution at 180 °C for 10 h (mPD-CDs). In the presence of mPD-CDs, Fe2+ can form a complex with 1,10-phenanthroline (Fe(II) – phenanthroline) without interference from mPD-CDs, which has an absorption peak centered at 512 nm and its absorbance is sensitive to the concentration of Fe(II) – phenanthroline. Accordingly, a colorimetric method for the detection of Fe2+ was constructed with a limit of detection (LOD) of 2.98 μM. Moreover, the absorption spectrum of the Fe (II)-phenanthroline complex is overlapping with the excitation and emission spectra of mPD-CDs located at 440 and 516 nm, respectively, resulting in an inner filter effect (IFE) which is sensitive to the concentration of Fe(II) – phenanthroline. Correspondingly, a fluorimetric method for the detection of Fe2+ based on the mPD-CDs/phenanthroline system was built with a LOD as low as 0.59 μM. Therefore, colorimetric and fluorimetric dual mode detection of Fe2+ in aqueous solution can be achieved by a carbon dots/phenanthroline system.  相似文献   

12.
《Analytical letters》2012,45(2-3):242-250
Natural polymer polysaccharides chitosan (CS) was successfully assembled with phytic acid (PA) into {PA/CS}n layer-by-layer films. Myoglobin (Mb) could be gradually “absorbed” or loaded into {PA/CS}n films when the films were immersed into Mb solutions, forming {PA/CS}n-Mb films. The {PA/CS}n-Mb films demonstrated well-defined and quasi-reversible cyclic voltammetry (CV) responses for Mb FeIII/FeII redox couple and were used to catalyze electrochemical reduction of oxygen and hydrogen peroxide. The interaction between Mb and {PA/CS}n films was explored and discussed, which suggested that the electrostatic attraction might play a major role in loading Mb into the films. This new kind of film incorporated with redox proteins could be used to fabricate the new type of biosensors or bioreactors without using mediators.  相似文献   

13.
《Electroanalysis》2003,15(18):1488-1493
The direct electron transfer between immobilized myoglobin (Mb) and colloidal gold modified carbon paste electrode was studied. The Mb immobilized on the colloidal gold nanoparticles displayed a pair of redox peaks in 0.1 M pH 7.0 PBS with a formal potential of –(0.108 ± 0.002) V (vs. NHE). The response showed a surface‐controlled electrode process with an electron transfer rate constant of (26.7 ± 3.7) s ?1 at scan rates from 10 to 100 mV s?1 and a diffusion‐controlled process involving the diffusion of proton at scan rates more than 100 mV s?1. The immobilized Mb maintained its activity and could electrocatalyze the reduction of both hydrogen peroxide and nitrite. Thus, the novel renewable reagentless sensors for hydrogen peroxide and nitrite were developed, respectively. The activity of Mb with respect to the pseudo peroxidase with a KMapp value of 0.65 mM could respond linearly to hydrogen peroxide concentration from 4.6 to 28 μM. The sensor exhibited a fast amperometric response to NO2? reduction and reached 93% of steady‐state current within 5 s. The linear range for NO2? determination was from 8.0 to 112 μM with a detection limit of 0.7 μM at 3σ.  相似文献   

14.
《Electroanalysis》2018,30(9):2044-2052
Acid functionalized multi‐walled carbon nanotubes (f‐MWCNTs) were decorated with Au and Fe2O3 nanoparticles (FeONPs) and deposited on glassy carbon electrode (GCE). The resulting hybrid Au/Fe2O3/f‐MWCNTs/GCE electrode and the one further modified by glucose oxidase were compared for detection of glucose. FeONPs and Au were deposited on the f‐MWCNTs by sonication‐assisted precipitation and deposition‐precipitation methods, respectively. The morphology and structure of the samples were characterized by transmission electron microscopy, scanning electron microscopy, X‐ray diffraction and Raman spectroscopy. A uniform distribution of FeONPs with an average size of 5 nm increased the surface area of functionalized nanotubes from 39 to 50 m2/g. The electrocatalytic glucose detection on the modified electrodes was evaluated using cyclic voltammetry and chronoamperometry in 0.1 M phosphate buffer solution at pH 7.0. The non‐enzymatic and enzymatic electrodes show sensitivity of 512.4 and 921.4 mA/mM.cm2 and detection limit of 1.7 and 0.9 mM, respectively. The enzymatic and enzymeless electrodes retained more than 70 % and 80 % of their cathodic faradic current after 70 days, respectively. The sensing mechanism of the non‐enzymatic biosensor is described through the reaction of glucose with iron (III) ions, while in the case of enzymatic electrode, glucose is oxidized by glucose oxidase.  相似文献   

15.
Here, we report an ultra-sensitive and colorimetric sensor for the detection of Fe3+ or Cu2+ successively using glutathione-functionalized Au nanoclusters (GSH-AuNCs). For GSH-AuNCs can catalytically oxidize peroxidase substrates, such as 3, 3′, 5, 5′-tetramethylbenzidine (TMB), colored products are formed in the presence of H2O2. While upon the addition of Fe3+ or Cu2+ into the GSH-AuNCs-TMB-H2O2 system, diverse color and absorbance of the system was obtained due to the self oxidation of Fe3+ and the inhibition of peroxidase-like activity of GSH-AuNCs. With the introduction of ethylene diamine tetraacetic acid (EDTA) or ammonium fluoride (NH4F) to GSH-AuNCs-TMB-H2O2+Cu2+ system or GSH-AuNCs-TMB-H2O2+Fe3+ system respectively, a restoration of color and absorbance of system was realized. On the basis of above phenomenon, a colorimetric and quantitative approach for detecting Fe3+ and Cu2+ was developed with detection limit of 1.25 × 10−9 M and 1.25 × 10−10 M respectively. Moreover, the concentration of Fe3+ and Cu2+ in human serums was also accurate quantified by this method. So this design strategy realized the simple and simultaneous detection of Fe3+ and Cu2+, suggesting significant potential in clinical diagnosis.  相似文献   

16.
The alkaline-luminol/H2O2-based chemiluminescent (CL) detection of Fe2+, Co2+, and Mn2+, separated with a Dionex CS5A ion chromatographic phase was studied by means of a multi-pump flow system allowing the variation of the post-column solution composition. A perchlorate gradient at pH 1.9 (with HCl) was used to separate cations partially complexed with 5.6 mM oxalate present in the eluent and necessary for the chosen separation phase. A 0.91 mM luminol, 3.3 mM H2O2 in 0.25 M carbonate buffer at pH 10.5 composition was chosen as CL reagent solution. The chosen pH value warrants signal repeatability and wider linearity range although absolute signal is not maximum. The CL signal was related to the pH of the two post-column mixing solutions. Calibration plots of Co2+ and Fe2+ were linear in the chosen concentration range whilst a parabolic model was the best fit for Mn2+. Detection limits were 0.24, 0.50 and 375 nM for Co2+, Fe2+ and Mn2+, respectively. The method was used to determine Co2+ at trace level in commercial copper chelates used for animal feeding. A comparison with a chromatographic method with spectrophotometric detection was made giving results comparable both in absolute values and accuracy.  相似文献   

17.
Song Qu  Jilie Kong  Gang Chen 《Talanta》2007,71(3):1096-1102
An electrochemical sensing platform was developed based on the magnetic loading of carbon nanotube (CNT)/nano-Fe3O4 composite on electrodes. To demonstrate the concept, nano-Fe3O4 was deposited by the chemical coprecipitation of Fe2+ and Fe3+ in the presence of CNTs in an alkaline solution. The resulting magnetic nanocomposite brings new capabilities for electrochemical devices by combining the advantages of CNT and nano-Fe3O4 and provides an alternative way for loading CNT on electrodes. The fabrication and the performances of the magnetic nanocomposite modified electrodes have been described. Cyclic voltammetry (CV) and constant potential measurement indicated that the incorporated CNT exhibited higher electrocatalytic activity toward the redox processes of hydrogen peroxide. In addition, chitosan (CTS) has also been introduced into the bulk of the CNT/nano-Fe3O4 composite by coprecipitation to immobilize glucose oxidase (GOx) for sensing glucose. The marked electrocatalytic activity toward hydrogen peroxide permits effective low-potential amperometric biosensing of glucose, in connection with the incorporation of GOx into CNT/Fe3O4/CTS composite. The accelerated electron transfer is coupled with surface renewability. TEM images and XRDs offer insights into the nature of the magnetic composites. The concept of the magnetic loading of CNT nanocomposites indicates great promise for creating CNT-based biosensing devices and expands the scope of CNT-based electrochemical devices.  相似文献   

18.
A novel turn-on rhodamine B-based fluorescent chemosensor (RBCS) was designed and synthesized by reacting N-(rhodamine B)lactam-1,2-ethylenediamine and carbon disulfide. Upon addition of Fe3+ in EtOH/H2O solution (2:1, v/v, HEPES buffer, 0.6?mM, pH 7.20), the RBCS displayed a significant fluorescence enhancement at 582?nm and a dramatic color change from colorless to pink, which can be detected by the naked eye. Significantly, the RBCS exhibited a highly selective and sensitive ability toward Fe3+. The detection limit of the probe was 2.05?×?10?7?M. Job's plot indicated the formation of 1:1 complex between the RBCS and Fe3+. Moreover, the practical use of the RBCS is demonstrated by its application in the detection of Fe3+ in HeLa cells.  相似文献   

19.
Photodynamic therapy (PDT) is a way of treating malignant tumors and hyperproliferative diseases. It is based on the use of photosensitizer, herein the chlorophyll a (chl a), and a light of an appropriate wavelength. The interaction of the photosensitizer (PS) with the light produces reactive oxygen species (ROS), powerful oxidizing agents, which cause critical damage to the tissue. To solubilize chl a in aqueous solution and to obtain it as monomer, we have used cyclodextrins, carriers which are able to interact with the pigment and form the inclusion complex. The aim of this study is to examine which types of ROS are formed by Chl a/cyclodextrin complexes in phosphate buffered solution and cell culture medium, using specific molecules, called primary acceptors, which react selectively with the reactive species. In fact the changes of the absorption and the emission spectra of these molecules after the illumination of the PS provide information on the specific ROS formation. The 1O2 formation has been tested using chemical methods based on the use of Uric Acid (UA), 9,10‐diphenilanthracene (DPA) and Singlet oxygen sensor green (SOSG) and by direct detection of Singlet Oxygen (1O2) luminescence decay at 1270 nm. Moreover, 2,7‐dichlorofluorescin and ferricytochrome c (Cyt Fe3+) have been used to detect the formation of hydrogen peroxide and superoxide radical anion, which reduces Fe3+ of the ferricytochrome to Fe2+, respectively.  相似文献   

20.
《Analytical letters》2012,45(6):839-855
Abstract

A glucose electrode was constructed by adsorbing glucose oxidase (GOD) on a modified electrode for H2 O 2 oxidation, consisting of Pd/Au sputtered on graphite. Maximally, 0.8 U cm?2 of GOD could be adsorbed. The electrode was used in a f.i.a. manifold for determination of glucose. Linear calibration curves were obtained in the concentration range 3. 10?6 4. 10?3 mol L?1 glucose. The applied potentials for glucose determination were + 300 mV vs. Ag/AgCl at pH 8.0, + 350 mV at pH 7.0, + 400 mV at pH 6.0 and + 500 mV at pH 5.0. The activity vs. pH profile of adsorbed GOD was broad having an optimum between pH 5 and 6. The apparent kinetic parameters for adsorbed GOD, KM app and imax, were found to be 50 mM and 160 uA at optimal pH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号