首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Simple and rapid extraction method for quantitative and selective isolation of the new local anesthetic pentacaine from biological materials is proposed. The technique of ion-pair formation was found to be more effective than usual access using the extraction of the nonionized species. The extraction yield of the unchanged molecule3H-pentacaine after double extraction and single scrubbing was found to be more than 90%. The radiochemical purity was over 90%. The method appears suitable for pharmacokinetic studies in the animal body.  相似文献   

2.
A simple and specific radiometric assay was developed for the determination of stobadine, a cardioprotective drug, in the serum of experimental animals. The assay is based on a single extraction step of the radioactively labeled drug from serum into the benzene solution of dicarbolide of cobalt followed by quantitation of the extracted radioactivity by using liquid scintillation counting. The extraction mechanism involves the ion-pair formation between the protonized molecule of stobadine and the hydrophobic, negatively charged molecule of dicarbolide of cobalt. The extraction yield of stobadine from 1 ml of serum was 95% in the concentration range from 1 to 6000 ng/ml. The co-extraction of metabolites was less than 5%. The method was applied to the determination of stobadine in serum of dogs and the data obtained were in a good agreement with those obtained by high performance liquid chromatography.  相似文献   

3.
Ion-pair solid-phase extraction   总被引:3,自引:0,他引:3  
Solid-phase extraction (SPE) is a technique widely employed by analytical chemists. SPE cartridges are available in a wide variety of formats containing media with diverse chemistries. This paper will review ion-pair SPE, one of the less frequently applied, and presumably less well-known techniques. Advantages of this technique over more conventional reversed-phase or ion-exchange SPE include selectivity, compatibility with rapid evaporative concentration, and potential application to multiclass multiresidue analysis.  相似文献   

4.
Summary Ion-Pair Extraction of Tetracyclines Tetracyclines form ion-pair complexes with dyes that can be extracted into chloroform and re-extracted into 0.1N hydrochloric acid and finally quantified by spectrophotometry. Of the dyes studied methyl red, methyl orange, bromophenol blue and bromothymol blue form complexes with cationic form of tetracycline (pH 8–9) and crystal violet with the anionic form (pH 9–10). 98% of tetracycline can be extracted from the body fluids and solution containing 10g/ml of tetracycline can be conveniently analyzed.  相似文献   

5.
A method for the determination of seven perfluorinated carboxylic acids and perfluorooctane sulphonate (PFOS) in aqueous samples using low-cost polymeric sorptive extraction as sample preparation technique, followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) determination has been developed and validated. Simplicity of the analytical procedure, low volume of solvent and sample required, low global price and a good selectivity providing cleaner extracts are the main advantages of this extraction technique. Polydimethylsiloxane (PDMS) and polyethersulfone (PES) materials were evaluated and compared to achieve the best extraction efficiencies. Hence, different variables have been optimized, viz.: sample pH, concentration of an ion-pairing agent (tetrabutylammonium), ionic strength, sample volume, extraction time, desorption solvent volume, desorption time and the need for auxiliary desorption techniques (sonication). Overall, PES leaded to a better sensitivity than PDMS, particularly for the most polar compounds, reaching detection limits (LODs) in the 0.2–20 ng L−1 range. The precision of the method, expressed as relative standard deviation (RSD), was lower than 16%. Finally, the PES material was employed for the analysis of sea, sewage and fresh water samples. Perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were detected in all the analyzed influent samples reaching levels of up to 401 ng L−1. In surface water, perfluorohexanoic acid (PFHxA) exhibited the highest concentrations, up to 137 ng L−1.  相似文献   

6.
Molecular imprints selective for a homologous series of local anaesthetics, including bupivacaine, ropivacaine and mepivacaine, were prepared and the resultant polymers were used for solid-phase extraction of human plasma. The template was a structural analogue, pentycaine, which was imprinted in methacrylic acid-ethylene glycol dimethacrylate copolymers. Equilibrium ligand binding experiments using radiolabelled bupivacaine were performed to characterize the imprinted polymers, as well as to identify optimal conditions for selective extraction of plasma samples. Dilution of the plasma prior to extraction with citrate buffer pH 5.0 containing ethanol and Tween 20 was found optimal for selective imprint-analyte binding, and for reduction of non-specific adsorption of lipophilic contaminants to the hydrophobic MIP surface. Wash steps using 20% methanol in water followed by a solvent switch to 10% ethanol in acetonitrile removed contaminants and strengthened the selective imprint-analyte binding. Elution under basic conditions using triethylamine-water-acetonitrile mixtures recovered bupivacaine in 89% yield with superior selectivity over elution under acidic conditions. The final protocol extracted trace levels of ropivacaine and bupivacaine from human plasma and allowed determination of bupivacaine in the range of 3.9-500 nmol L−1 and ropivacaine in the range of 7.8-500 nmol L−1 with inter-assay accuracies of 94-99 and 95-104%, respectively. This present investigation provides an improved understanding of approaches available for optimization of protocols for molecular-imprint based solid-phase extraction of plasma samples.  相似文献   

7.
Summary Local anaesthetics have been shown to be extractable from human whole blood samples by direct immersion (DI)-solid phase micro extraction (SPME). After deproteinization with perchloric acid, the pH of the clear supernatants of human whole blood samples containing the drugs were adjusted to about 7 with 10 M NaOH in the presence of NaCl; a polydimethylsiloxanecoated SPME fiber was then immersed directly into the sample solution to allow adsorption of the drugs before capillary gas chromatography (GC) with flame ionization detection. The DI-SPME for 1-mL whole blood gave peaks for all the drugs; only a small amount of background noise appeared and this gave no problems in the detection of the drugs. Recoveries of the ten drugs from human whole blood was 0.74–19.7 %. The calibration curves for seven drugs showed linearity in the range of 0.25–12 g mL–1 whole blood, with detection limits of 54–158 ng mL–1.  相似文献   

8.
9.
Mohapatra PK  Manchanda VK 《Talanta》1998,47(5):2437-1278
Ion-pair extraction behaviour of uranyl ion from aqueous solutions was studied at pH 3.0 employing crown ethers viz. benzo 15 crown 5 (B15C5), 18 crown 6 (18C6), dibenzo 18 crown 6 (DB18C6), and dibenzo 24 crown 8 (DB24C8) in chloroform as the organic phase and picric acid as the organophilic counter anion. The stoichiometry of the extracted species corresponded to [UO2(crown ether)n]2+·[pic]2 where n=1.5 for benzo 15 crown 5 and 1 for 18 crown 6 as well as dibenzo 18 crown 6. Adducts of DB24C8 could not be observed as practically no extraction was possible using this reagent. The separation behaviour of fission products from an irradiated uranium target was also studied. An interesting observation on the separation of trivalent lanthanides from uranyl ion is reported.  相似文献   

10.
A pressurised liquid extraction (PLE) procedure, by using methanol/water mixture, was developed for extracting arsenical species from marine biological material (mussel and fish) and standard reference materials (CRMs). A Plackett-Burman 28 × 3/64 designs (PBD) was used as a multivariate strategy for the evaluation of the effects of several variables (MeOH/H2O solvent mixture, temperature, static time, extraction steps, pressure, mean particle size and diatomaceous earth (DE) mass/sample mass ratio) on the extracting procedure. Electrothermal atomic absorption spectrometry (ETAAS) was used to determine the total As concentration on the methanolic extracts. The accuracy of the optimised extraction procedure was verified by analysing several CRMs (GBW-08751, BCR-278R and DORM-2). The precision obtained (between 4.5 and 6.2%) was adequate. The extracted arsenic species (mainly arsenobetaine (AsB)) were analysed by high performance liquid chromatography coupled to ultraviolet cracking and hydride generation-atomic fluorescence spectrometry (HPLC-UV-HG-AFS). The analytical performances obtained were adequate for the arsenic speciation in marine biological samples; LOD between 10 and 35 ng g−1. The accuracy was verified for AsB using DORM-2. Finally, the proposed method (PLE followed by HPLC-UV-HG-AFS) was applied to mussel and fish samples.  相似文献   

11.
Ion-pair extraction behaviour of plutonium (IV) from varying concentrations of HCl solution was studied employing crown ethers (benzo-l5-crown-5 (B15C5), 18-crown-6, (18C6), dibenzo-18-crown-6 (DB18C6), dicyclohexano-18-crown-6, (DC18C6), dibenzo-24-crown-8 (DB24C8) and dicyclohexano-24-crown-8 (DCH24C8)) in nitrobenzene as the extractant. Ammonium metavanidate was used as the holding oxidant in the aqueous phase and the conditions necessary for the quantitative extraction of the tetravalent ion were found. The co-extraction of species of the type [HL+].[HPu(Cl) 6 ] and [HL+]2·[Pu(Cl) 6 2– ] as ion-pairs (where L represents the crown ether) is suggested.  相似文献   

12.
Khalifa SM  F Aly H  Navratil JD 《Talanta》1989,36(3):406-408
The extraction of cobalt(II) by chloroform solutions of the crown ethers (CE) 12C4, I5C5, 18C6, Dbl8C6, Dchl8C6 or Dch24C8 from aqueous perchlorate medium was investigated. Slope analysis of the experimental data suggested that the extraction of Co(II) by these CEs takes place through ion-pair formation, and that the chemical formula of the main extracted species is Co(OH)(+)ClO(-)(4).CE. The magnitudes of the extraction constants are in the sequence 18C6 > Dch18C6 > Dch24C8 > Db18C6 > 15C5 > 12C4, which is discussed in terms of the correspondence between the CE cavity size and the ionic radius of cobalt(II).  相似文献   

13.
Summary Solidago canadensis L., Canadian goldenrod (Asteraceae) has been used in European phytotheraphy for centuries as a component of urological and antiphlogistical remedies. High-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and online mass spectrometry (MS) has been used for the separation and quantification of phenolics (chlorogenic acid, caffeic acid, kaempferol-3-O-α-L-rutinoside (nicotiflorin), quercetin-3-O-β-D-rutinoside (rutin), quercetin-3-O-β-D-galactoside (hyperoside), quercetin-3-O-β-D-glucoside (isoquercitrin), quercetin-3-O-β-D-rhamnoside (quercitrin), kaempferol-3-O-α-L-rhamnoside (afzelin) and quercetin from Solidaginis herba. Extracts have been obtained using different technologies. Three aqueous and three alcoholic extracts were studied separately. Reversedphase high-performance liquid chromatography separation of polyphenols on octadecyl sorbent Hypersil was performed, using acetonitrile: acetic acid 2.5 v/v % as eluent in gradient elution. Our results confirm previous reports concerning the presence of several flavonoids. Quantification of the main quercetin glycosides in pharmaceuticals is also reported. Presented at Balaton Symposium '01 on High-Performance Separation Methods, Siófok, Hungary, September 2–4, 2001  相似文献   

14.
Electro-assisted extraction of ionic drugs from biological fluids through a supported liquid membrane (SLM) and into an aqueous acceptor solution was recently introduced as a new sample preparation technique termed electromembrane extraction (EME). The applied electrical potential across the SLM has typically been in the range of 1-300 V. Successful extractions have been demonstrated even with common batteries (9 V) instead of a power supply. The chemical composition of the SLM has been crucial for the selectivity and for the recoveries of the extraction. Compared to other liquid-phase microextraction techniques (LPME), extraction times have been reduced by a factor of 6-17, and successful extractions have been obtained at extraction times of 1-5 min, and even down to a few seconds with online microfluidic EME devices. The technique has provided very efficient sample clean-up and has been found well suited for the extraction of sample sizes in the low μL range. Extractions have been performed with both rod-shaped hydrophobic porous fibers and with flat hydrophobic porous sheets as SLM support. The technique has been successfully downscaled into the micro-chip format. The nature of the SLM has been tuned for extraction of drugs with different polarity allowing extractions to be tailored for specific applications depending on the analyte of interest. The technique has been found to be compatible with a wide range of biological fluids and extraction of drugs directly from untreated human plasma and whole blood has been demonstrated. EME selectively extracts the compounds from the complex biological sample matrix as well as allowing concentration of the drugs. With home-built equipment fully acceptable validation results have been obtained.  相似文献   

15.
The recognition properties of acyclic cucurbit[n]uril (CB[n]) congener 1 towards seven local anaesthetic drugs (2–8) are reported. Job plots constructed from 1H NMR experiments confirm the 1:1 host:guest nature of these complexes, whereas the changes in chemical shift observed upon complex formation (Δδ values) provide information about the geometry of the host–guest complexes. For complexes between host 1 and guests 25 and 8, a single geometry was preferred, whereas for guests 6 and 7 a mixture of two diastereomeric complexes was indicated. The K a values for complexes between 1 and 28 fall in the range of 103–108 M? 1 as determined by UV–vis and 1H NMR competition experiments. The results further establish that acyclic CB[n]-type receptor 1 is preorganised into the C-shape required for binding and that its aromatic o-xylylene walls endow it with a potency towards aromatic ammonium ions. The K a values reported in this paper constitute a blind data-set used in the SAMPL3 challenge aimed at testing computational methods relevant to protein√ligand systems. The work thus highlights the great potential of CB[n] receptors as model systems to promote synergy between the supramolecular and computational chemistry communities.  相似文献   

16.
Chiral separation of local anaesthetics with capillary electrophoresis   总被引:1,自引:0,他引:1  
Summary A chiral capillary electrophoresis system for the highresolution separation of the enantiomers of the local anaesthetics mepivacaine, ropivacaine, bupivacaine and prilocaine is described. Triethanolamine was added to the background electrolyte to obtain a negative electroosmotic flow and hence higher resolutions. The interactions of the local anaesthetics and their chemical analogues with the chiral selector, dimethyl--cyclodextrin, were studied. From a model describing chiral capillary electrophoresis, the association equilibrium constants were determined by curve-fitting. The separation of mepivacaine, ropivacaine and bupivacaine was due to the different mobilities of the free analytes in solution, whereas the separation of a pair of enantiomers of a single analyte was due to differences between the association equilibrium constantsK 1 andK 2. Branching of the alkyl chain, which was situated close to the cavity in the inclusion complex, had strong effects on the chiral separation of the enantiomers.  相似文献   

17.
The complexation of several local anaesthetics by β and γ-cyclodextrins was studied by potentiometry with glass electrode. Tetracaine and dibucaine complexation constants were determined at 25°C in the presence of 0.1 M of NaCl. It was found that prilocaine and lidocaine complexes cannot be detected.  相似文献   

18.
19.
Some cinchona alkaloids, the quinine/quinidine and cinchonine/cinchonidine pairs, are extracted by ion-pair formation with some chiral amino acids and d-camphorsulfonic acid. Their extraction behaviors are examined and the differences between the two isomers are compared. These alkaloids are extracted into chloroform in the pH range 4–7 as the 1:1 ion-pair with the organic acid. The relationship between the distribution ratio of the ion-pair and pH is discussed. In the pH range between the pKa1 and pKa2 values of these alkaloids, logarithmic plots of the distribution ratio are independent of pH. In this pH region, the extraction constants are determined and the differences caused by the ion-pair formation are discussed.  相似文献   

20.
Electromembrane extraction coupled with high-performance liquid chromatography (HPLC) and ultraviolet (UV) detection was developed for the determination of levamisole in some human biological fluids. Levamisole migrated from 4 mL of different acidized biological matrices, through a thin layer of 2-nitrophenyl octyl ether containing 5% tris-(2-ethylhexyl) phosphate immobilized in the pores of a porous hollow fiber, into a 20-μL acidic aqueous acceptor solution present inside the lumen of the fiber. The parameters influencing electromigration were investigated and optimized. Within 15 min of operation at 200 V, levamisole was extracted from different biological fluid samples with recoveries in the range of 59-65%, which corresponded to preconcentration factors in the range of 118-130. The calibration curves showed linearity in the range of 0.5-10, 0.2-10 and 0.1-10 μg/mL for plasma, urine and saliva, respectively. Limits of detection of 0.1, 0.07 and 0.05 μg/mL and limits of quantification of 0.5, 0.2 and 0.1 μg/mL were obtained for plasma, urine and saliva, respectively. The relative standard deviations of the analysis were found to be in the range of 5.6-9.7% (n = 3). Electromembrane extraction was successfully processed for determination of levamisole in plasma, urine and saliva samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号