首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method based on capillary electrophoresis-amperometric detection has been developed for the determination of catechin, rutin, kaempferol, gentistic acid, and quercetin in Folium Eriobotryae with the aid of microwave-assisted solvent extraction. The effects of the acidity and the concentration of the running buffer, separation voltage, injection time, detection potential, and irradiation time were investigated to acquire the optimum analysis conditions. The detection electrode was a 300-mum-diameter carbon disc electrode at a detection potential of +0.90 V. The five analytes could be well separated within 12 min in a 40-cm length fused-silica capillary at a separation voltage of 12 kV in a 50-mM borate buffer (pH 9.0). The relation between peak current and analyte concentration was linear over about three orders of magnitude with detection limits (S/N=3) ranging from 2.1 to 4.5 microM for all the analytes.  相似文献   

2.
 对新型造影试剂碘海醇及其杂质进行了分离和测 定研究。以硼酸盐为缓冲体系,使中性的多元醇类物质碘海醇及其杂质通过络合反应而带负 电,加入十六烷基三甲基溴化铵反转电渗流以加快分析速度,再加入适量异丙醇以进一步改 善分离结果。对该方法的定量线性范围和重现性进行了考察,将分离结果与用HPLC测定的结 果进行了比较。  相似文献   

3.
A simple and sensitive non-aqueous capillary electrophoresis method has been developed for simultaneous assay of three bioactive components (puerarin, daidzein and wogonin) in three traditional medicinal preparations for the first time. Optimum separation of the analytes was obtained on a 47 cm x 75 microm i.d. capillary using a non-aqueous buffer system of 20% acetonitrile, 25 mm ammonium acetate and apparent pH 9.00, with applied voltage and capillary temperature of 20 kV and 16 degrees C, respectively. The relative standard deviations (RSDs) of the migration times and the peak areas of the three analytes were in the ranges 2.5--4.0% and 3.2--3.9%, respectively. Detection limits of puerarin, daidzein and wogonin were 0.090, 0.145 and 0.090 microg mL(-1), respectively. In the tested concentration range, good linear relationships (correlation coef fi cients: 0.9998 for puerarin, 0.9998 for daidzein and 0.9978 for wogonin) between peak areas and concentrations of the analytes were observed. This method has been successfully applied to simultaneous determination of the three bioactive components with recoveries from 91.0 to 114.0%.  相似文献   

4.
食品中金属离子的微波消解-高效毛细管电泳法测定   总被引:5,自引:0,他引:5  
采用微波消解-高效毛细管电泳法测定食品中的K,Na,Ca,Mg等金属离子,考察了微波消解的最佳条件;研究了背景电解质,缓冲液pH值,操作温度和分离电压等对电泳分离中运行电流,电渗迁移率,峰形等参数的影响,确定了金属离子电泳分离的最佳实验条件;该法已应用于食品中金属离子的测定,并与原子吸收法进行比较,得到满意的结果。  相似文献   

5.
Capillary zone electrophoresis coupled with a capacitively coupled contactless conductivity detector (CE‐C4D) has been employed for the determination of atenolol and amiloride in pharmaceutical formulations. Acetic acid (150 mm ) was used as background electrolyte. The influence of several factors (detector excitation voltage and frequency, buffer concentration, applied voltage, capillary temperature and injection time) was studied. Non‐UV‐absorbing L‐valine was used as internal standard; the analytes were all separated in less than 7 min. The separation was carried out in normal polarity mode at 28°C, 25 kV and using hydrodynamic injection (25 s). The separation was effected in an uncoated fused‐silica capillary (75 μm, i.d. × 52 cm). The CE‐C4D method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 5–250 μg/mL for the studied analytes. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 6.0%. The method showed good precision and accuracy and was successfully applied to the simultaneous determination of atenolol and amiloride in different pharmaceutical tablet formulations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
A capillary zone electrophoretic method has been developed for the determination of four coumarins--skimmin, scopolin, scopoletin, and umbelliferone-in Saussurea superba with UV detection at 254 nm. The capillary temperature was kept constant at 25 degrees C. Effects of buffer pH, electrolyte concentration, organic modifier, and applied voltage on migration behavior were studied systematically. The optimum conditions for separation were achieved by using 30 mM borate buffer at pH 9.02 containing 15% (v/v) methanol as the electrolyte and 25 kV as the applied voltage. For all analytes a good linear regression relationship (r > 0.999) was obtained between peak area and concentration over a relatively wide range. The method was validated for repeatability, precision, and accuracy. The validated method was successfully applied to the simultaneous determination of the four analytes in S. superba.  相似文献   

7.
Chen G  Zhang H  Ye J 《Talanta》2000,53(2):471-479
A method based on capillary electrophoresis with electrochemical detection (CE-ED) was developed for the determination of baicalein, baicalin and quercetin in Scutellariae Radix and its pharmaceutical preparations. The effects of some important factors such as the acidity and concentration of running buffer, separation voltage, injection time, and the potential of working electrode were investigated to acquire the optimum condition. The working electrode was a 300-mum diameter carbon disc electrode positioned opposite the outlet of capillary. The three analytes could be well separated within 12 min in a 40 cm length capillary at the separation voltage of 12 kV in a 100 mmol l(-1) borate buffer (pH 9.0). The response was linear over three orders of magnitude with detection limits (S/N=3) ranged from 0.224 to 0.548 mumol l(-1) for all three analytes. This proposed method demonstrated good long-term stability and reproducibility with R.S.D. of less than 5% for both migration time and peak current (n=7). It has been successfully applied to analyze the actual samples with satisfactory assay results.  相似文献   

8.
This work reported that ionic liquid (IL) ([Bmim] [PF6]) and sulfobutylether‐β‐CD (SBE‐β‐CD) were used as electrolyte additives for the separation and determination of camptothecin (CPT) alkaloids by CZE. Separation parameters such as the buffer type, pH, and concentration of the running buffer, the concentration of SBE‐β‐CD and IL, temperature, and separation voltage were all investigated in order to achieve the maximum possible resolution. The four analytes were baseline separated within 10 min in capillary at the separation voltage of 15 kV with a running buffer consisting of 20 mM borate buffer, 20 mM IL, and 100 mM SBE‐β‐CD at pH 9.0. Under such conditions, good linearity about two orders of magnitudes of peak areas was achieved for the investigated CPT alkaloids with the correlation coefficients ranging from 0.9946 to 0.9985. For all analytes, detection limits (S/N = 3) and quantitation limits (S/N = 10) range from 0.05 to 0.92 μg/mL and 0.17 to 3.06 μg/mL, respectively. The proposed method has not only been successfully applied to the separation and determination of CPT alkaloids but also showed that IL seemed to be a promising additive in CZE separation.  相似文献   

9.
Rhodiola, in which there are abundant pharmacologically active ingredients, is one of the functional adaptogenic agent that aid specific bodily functions to adapt to the changes and stress of life in addition to being tonic. In an attempt to qualitatively and quantitatively determine the pharmacologically active ingredients in Rhodiola, a new method based on capillary electrophoresis with electrochemical detection (CE-ED) has been developed. The effects of working electrode potential, pH and concentration of running buffer, separation voltage, applied potential and injection time on CE-ED were investigated. Under the optimum conditions, the analytes could be well separated within 24 min at the separation voltage of 18 kV in a 80 mmol L(-1) borax running buffer (pH 9.0). Good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N=3) ranged from 3.16 x 10(-7) to 1.11 x 10(-7)g mL(-1) for all target ingredients. This proposed method has been successfully applied for the analysis of real samples, with satisfactory results.  相似文献   

10.
A specific, sensitive and rapid analytical procedure based on capillary electrophoresis with UV/Vis detection at 405 and 415?nm was developed and validated to detect human haemoglobin and haemoglobin-based oxygen carriers (Hemopure?, Oxyglobin? and Polyheme?) in blood samples collected for doping control. The electrophoretic separation, based on capillary dynamic coating, was achieved in less than 10 min. The effects of capillary temperature, injection conditions and initial ramping were investigated. The optimum separation voltage was 25 kV with a capillary temperature of 20 °C, initial ramping of 1?kV/s and an injection pressure of 0.5?psi for 10?s. The removal of haptoglobin using anti-human haptoglobin antibody prior to the analysis was mandatory to increase the specificity of the analysis. Sufficient resolution between endogenous haemoglobin variants and the three haemoglobin-based oxygen carriers here investigated was obtained, thus allowing discrimination between a normal haemolysed sample and a sample in which Oxyglobin?, Hemopure? or Polyheme? is present. Good repeatability of migration times (CV% less than 1), peak resolution and adequate sensitivity (limit of detection: 2.5?mg/mL) was obtained.  相似文献   

11.
The separation of anionic, cationic and neutral drugs in microemulsion electrokinetic chromatography (MEEKC) was studied with a statistical experimental design. The concentration of sodium dodecyl sulfate (SDS, surfactant), 1-butanol (co-surfactant) and borate buffer and the factors Brij 35 (surfactant), 2-propanol (organic solvent) and cassette temperature were varied simultaneously, while the parameters pH (9.2), the concentration of octane (oil, 0.8% w/w), the voltage (10 kV) and the dimension of the fused-silica capillary, were kept constant. Eight different model substances were chosen with different hydrophobicities. Two of the analytes were positively charged, two were negatively charged, and the remaining four were neutral or close to neutral at the pH explored. The importance of each parameter on the separation window, the plate height and the retention factor for each of the analytes was studied by means of multiple linear regression (MLR) models. A new response was evaluated for anions, the quotient between the effective mobility in the microemulsion and the effective mobility in the corresponding buffer. Factors affecting selectivity changes were also explored, and it was found that SDS and 2-propanol had the largest effect on selectivity.  相似文献   

12.
A method based on capillary electrophoresis with amperometric detection has been developed for the determination of luteolin, chlorogenic acid, 3,5-dicaffeoylquinic acid and caffeic acid in the dried flower buds, leaves and stems (three medicinal parts) of Lonicera confusa DC., respectively. The effects of several important factors such as detection potential, the concentration of the running buffer, separation voltage and injection time were investigated to acquire the optimum conditions. The detection electrode was a 300 microm diameter carbon disc electrode at a working potential of + 0.90 V (vs saturated calomel electrode). The four analytes can be well separated within 10 min in a 40 cm-long fused silica capillary at a separation voltage of 12 kV in a 50 mM borate-25 mM phosphate buffer (pH 8.0). The relationship between peak current and analyte concentration was linear over about 3 orders of magnitude with detection limits (S/N = 3) ranging from 0.35 to 0.52 microM for all analytes. The proposed method has been successfully applied to the monitoring of bioactive constituents in the real plant samples with satisfactory assay results.  相似文献   

13.
Capillary electrophoresis with electrochemical detection has been employed for the separation and determination of the three active constituents (paeonol, benzoyloxypaeoniflorin, and oxypaeoniflorin) in traditional Chinese medicine, Moutan Cortex (root cortex of Paeonia suffruticosa Andrews). The effects of several important factors, such as the concentration of running buffer, the separation voltage, the injection time, and the detection potential, were investigated to determine the optimum conditions. The detection electrode was a 300 microm diameter carbon-disc electrode at a working potential of +0.90 V (versus SCE). The three analytes could be well separated within 7 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 50 mM borate buffer (pH 9.2). The relation between the peak current and the analyte concentration was linear over 3 orders of magnitude with detection limits (S/N = 3) ranging from 0.4 to 0.7 microM for all analytes. The proposed method has been successfully applied to the determination of paeonol, benzoyloxypaeoniflorin, and oxypaeoniflorin in real plant samples with satisfactory assay results.  相似文献   

14.
In contrast to α-, β- and γ-cyclodextrins, little information is available on the isolation and separation of cycloamylose (CA) with degree of polymerization (DP) larger than 22. The objective of the current study was to develop a new iodine affinity capillary electrophoresis (CE) for separation of CA with DP of 22-42, which was based on the formation of CA-iodine inclusion complexes, CA with twisted conformations made complicated mobility behaviors on CE instead of merely size dependent. The influences of iodide/iodine ratio, iodine concentration, pH, ion strength of running phosphate buffer, voltage, and temperature on the peak resolution and electrophoretic mobility were further investigated. Our results suggest that iodine affinity capillary electrophoresis provides a versatile and selective tool for the isolation and analysis of CA with DP from 22 to 42.  相似文献   

15.
A method based on capillary electrophoresis with electrochemical detection has been employed for the separation and determination of homocysteine, cysteine, reduced glutathione, ascorbic acid and uric acid. Effects of several important factors such as the acidity and concentration of the running buffer, separation voltage, injection time and detection potential were investigated to acquire the optimum conditions. The detection electrode was a 500 microm diameter platinum disk electrode at a working potential of +1.05 V (vs saturated calomel electrode). The five analytes were well separated within 10 min in a 50 cm long fused silica capillary at a separation voltage of 18 kV in a 100 mm phosphate buffer (pH 7.8). The relation between peak current and analyte concentration was linear over about 3 orders of magnitude with the detection limits (S/N = 3) ranging from 0.83 to 2.58 microm. The proposed method was successfully applied to determine cysteine, reduced glutathione, ascorbic acid and uric acid in human whole blood and rat brain tissues with satisfactory assay results and should find a wide range of bioanalytical applications.  相似文献   

16.
采用毛细管电泳/安培检测法(CE/AD)同时分离测定了绿茶中的芦丁、没食子酸、槲皮素、绿原酸等生物活性成分的含量, 考察了运行缓冲液酸度、浓度、分离电压、氧化电位和进样时间等实验参数对分离、检测的影响。在最优化条件下, 以300 μm碳圆盘电极为检测电极, 检测电位为+ 950 mV (vs. SCE) , 60 mmol/L硼酸盐运行缓冲液(pH 8.7)中, 上述各组分在20 min内可实现基线分离。各组分浓度与峰电流在3个数量级范围内呈良好线性, 检出限(S/N=3)在1.0×10-7到1.0×10-4g.mL-1范围,四种标样7次平行进样的相对标准偏差(RSD)小于3.0 %。该方法已成功地应用于绿茶中生物活性成分的测定, 结果令人满意。  相似文献   

17.
A capillary zone electrophoresis method coupling square wave amperometric detection (SWAD) for the simultaneous determination of positional isomers of benzendiols (i.e. o-, m-, p-benzenediols) has been developed. Effects of several factors, such as the composition of the running buffer, the pH value, separation voltage, injection time and the potential applied to the working electrode, were investigated to acquire the optimum conditions. The efficacy of the boric acid and ascorbic acid in the running buffer were discussed. o-, m-, p-Benzendiols can be well separated within 8 min in a 50 cm length of 50 microm diameter fused-silica capillary at a separation voltage of +15 kV. Operated in a wall-jet configuration, a 100 microm Pt-disk electrode used as the working electrode exhibits good response for the analytes. The relation between peak current and analyte concentration was linear over two orders of magnitude with detection limits (S/N = 3) ranging from 0.5 to 1.5 microM for all analytes. The proposed method has been successfully applied to monitor the o-, m-, p-benzendiols contents in the environmental wastewater samples with satisfactory assay results.  相似文献   

18.
A method based on capillary electrophoresis with electrochemical detection was developed for the determination of puerarin, daidzein and rutin. Effects of several important factors such as the acidity and concentration of running buffer, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions. The working electrode was a 300-microm diameter carbon disc electrode positioned opposite the outlet of capillary. The three analytes could be well separated within 12 min in a 40 cm length capillary at a separation voltage of 9 kV in a 50 mmol/l borate buffer (pH 9.0). The relationship between peak currents and analyte concentrations was linear over about three orders of magnitude with detection limits (SIN=3) ranging from 0.241 x 10(-6) to 0.511 x 10(-6) mol/l for all compounds. This proposed method demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for both migration time and peak current (n=7). It has been successfully applied for the determination of puerarin, daidzein and rutin in Chinese traditional drugs, the vines of Pueraria lobata (Wild.) Ohwi and Puerariae Radix.  相似文献   

19.
A micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the antiviral drugs acyclovir and valacyclovir and their major impurity, guanine, was developed. The influences of several factors (surfactant and buffer concentration, pH, applied voltage, capillary temperature and injection time) were studied. Using tyramine hydrochloride as internal standard, the analytes were all separated in about 4 min. The separation was carried out in reversed polarity mode at 28°C, 25 kV and using hydrodynamic injection (15 s). The separation was effected in a fused‐silica capillary 100 μm × 56 cm and a background electrolyte of 20 mM citric acid–1 M Tris solution (pH 2.75), containing 125 mM sodium dodecyl sulphate and detection at 254 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 0.1–1 μg/mL (guanine) and from 0.1 to 120 μg/mL for both valacyclovir and acyclovir. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 5.0%. The proposed method was successfully applied to the determination of the analytes in tablets and creams. From the previous study it is concluded that the stability‐indicating method developed for acyclovir and valacyclovir can be used for analysis of the drug in various stability samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A fast and accurate micellar electrokinetic capillary chromatography method was developed for quality control of pharmaceutical preparations containing cold remedies as acetaminophen, salicylamide, caffeine, phenylephrine, pseudoephedrine, norephedrine and chlorpheniramine. The method optimization was realized on a Beckman P/ACE System MDQ instrument. The baseline separation of seven analytes was performed in an uncoated fused silica capillary internal diameter (ID)=50 microm using tris-borate (20 mM, pH=8.5) containing sodium dodecyl sulphate 30 mM BGE. On line-UV detection at 214 nm was performed and the applied voltage was 10 kV. The operating temperature was 25 degrees C. After experimental conditions optimization, the proposed method was validated. The evaluated parameters were: precision of migration time and of corrected peak area ratio, linearity range, limit of detection, limit of quantification, accuracy (recovery), ruggedness and applicability. The method was then successfully applied for the analysis of three pharmaceutical preparations containing some of the analytes listed before.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号