共查询到20条相似文献,搜索用时 0 毫秒
1.
A rapid method, based on sonication-assisted extraction in small columns (SAESC) and subsequent quantification and identification by gas chromatography-mass spectrometry (GC-MS), was developed for the determination of cyclic and linear siloxanes in soil. In the experiments with spiked samples (10-50 ng g(-1)), the recovery of cyclic and linear siloxanes ranged from 87.7 to 108.0% and from 84.9 to 107.6%, respectively. The validated method was used to determine the levels of these compounds in various types of soil samples collected from different locations in Spain. The cyclic siloxanes, decamethylcyclopentasiloxane (D5) and dodecamethylcyclohexasiloxane (D6) were detected in all the soil samples analyzed at concentrations from 9.2 to 56.9 ng g(-1) for D5 and from 5.8 to 27.1 ng g(-1) for D6 in agricultural soils and from 22 to 184 ng g(-1) for D5 and from 28 to 483 ng g(-1) for D6 in industrial soils. The total linear siloxanes concentrations (L5-L14) (sum of the 10 congeners) ranged from 191 to 292 ng g(-1) in agricultural soils and from 1411 to 8532 ng g(-1) in industrial soils. 相似文献
2.
Three preconcentration techniques including solid phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and stir-bar sorptive extraction (SBSE) have been optimized and compared for the analysis of six hypolipidaemic statin drugs (atorvastatin, fluvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin) in wastewater and river water samples by high performance liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (HPLC/Q-TOF-MS). Parameters that affect the efficiency of the different extraction methods such as solid phase material, sample pH and elution solvent in the case of SPE; the type and volume of the extracting and dispersive solvent, pH of sample, salt addition and number of extraction steps in the case of DLLME; and the stirring time, pH of sample, sample volume and salt addition for SBSE were evaluated. SPE allowed the best recoveries for most of the analytes. Pravastatin was poorly extracted by DLLME and could not be determined. SBSE was only applicable for lovastatin and simvastatin. However, despite the limitations of having poorer recovery than SPE, DLLME and SBSE offered some advantages because they are simple, require low organic solvent volumes and present low matrix effects. DLLME required less time of analysis, and for SBSE the stir-bar was re-usable. SPE, DLLME and SBSE provided method detection limits in the range of 0.04-11.2 ng L−1, 0.10-17.0 ng L−1 for 0.52-2.00 ng L−1, respectively, in real samples. To investigate and compare their applicability, SPE, DLLME and SBSE procedures were applied to the detection of statin drugs in effluent wastewater and river samples. 相似文献
3.
An analytical method for the determination of UV filters in soil and sediment has been developed and validated considering benzophenones (BP) and salicylates as target analytes. Soil and sediment samples were extracted with ethyl acetate-methanol (90:10, v/v) assisted with sonication, performing a simultaneous clean-up step. Quantification of these compounds was carried out by gas chromatography-mass spectrometry (GC-MS) after derivatization of the extracts with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA). Recoveries from spiked soil samples ranged from 89.8% to 104.4% and they were between 88.4% and 105.3% for spiked sediment samples. The effect of the residence time and soil moisture content on the recovery of these compounds was also studied. The precision, expressed as relative standard deviation, was in all cases below 6.1% and the limits of detection (S/N=3) varied from 0.07 to 0.10 ng g(-1) and from 0.11 to 0.28 ng g(-1) for soils and sediments, respectively. The validated method was applied to the analysis of five benzophenone and two salicylate UV filters in soil and sediment samples collected in different areas of Spain. 相似文献
4.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples. 相似文献
5.
Odour-causing organic compounds in wastewater treatment plants: evaluation of headspace solid-phase microextraction as a concentration technique 总被引:1,自引:0,他引:1
Godayol A Alonso M Besalú E Sanchez JM Anticó E 《Journal of chromatography. A》2011,1218(30):4863-4868
Odorous emissions from wastewater collection systems and treatment facilities affecting quality of life have given local populations reasons to complain for decades. In order to characterise the composition of such malodorous emissions, a method based on headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled to mass spectrometry (GC-MS) has been developed to determine a list of compounds belonging to different chemical families, which have been previously described as potentially responsible for odour complaints, in wastewater matrices. Some parameters affecting the chromatographic behaviour of the target compounds were studied (e.g. splitless time). Experimental conditions affecting the extraction process (temperature, time and salt content) were evaluated by applying a factorial design at two levels. Using a DVB/CAR/PDMS fibre and the optimised HS-SPME conditions, calibration curves were constructed with detection limits in the range of 0.003-0.6 μg L(-1). Recovery values higher than 70% and relative standard deviation values between 5 and 16% (n=5) were obtained for all compounds and found to be satisfactory. In wastewater samples, a decrease in the concentration of the analysed compounds through the different treatments was observed. Most of the target analytes were found in influent samples while only octanal and carvone were detected in samples from the plant effluent. 相似文献
6.
Headspace solid phase microextraction (HS-SPME) in-situ supercritical fluid extraction (SFE) was investigated for the determination of trace amounts of perfluorocarboxylic acids (PFCAs) in sediments. Quantitation was performed by using gas chromatography coupled to negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS). The optimum conditions of HS-SPME following SFE were obtained using 500 μL n-butanol as a derivatization reagent in supercritical carbon dioxide with static extraction for 10 min, then dynamic extraction for 20 min at 30 MPa and 70 °C and simultaneous collected with 100 μm film thickness PDMS fiber. The linear range of proposed method was from 5 to 5000 ng g(-1), with limit of detection ranging from 0.39 to 0.54 ng g(-1) and limit of quantitation ranging from 1.30 to 1.80 ng g(-1). The developed method was successfully applied to analyze PFCAs in sediments from rivers and beach near industrial areas. The concentrations of PFCAs determined are from 282 to 4473 ng g(-1). 相似文献
7.
固相萃取-高效液相色谱-串联质谱法同时测定尿液中的4种巯基尿酸 总被引:1,自引:0,他引:1
建立了固相萃取-高效液相色谱-串联质谱(HPLC-MS/MS)同时检测人体尿液中N-乙酰基-S-(3,4-二羟基丁基)-L-半胱氨酸(DHBMA)、N-乙酰基-S-(3-羟基丙基)半胱氨酸(3-HPMA)、N-乙酰基-S-(2-氰乙基)-L-2-氨基-3-巯基羧酸(CEMA)和苯巯基尿酸(SPMA)的检测方法。冰冻的人体24 h尿液在室温下解冻,混合均匀后离心过滤,经C18固相萃取小柱净化富集后在多反应监测模式下采用HPLC-MS/MS进行定量分析。在3个添加水平下,尿液中DHBMA、3-HPMA、CEMA和SPMA的加标回收率分别为105.6%~124.4%、102.7%~106.5%、103.2%~103.9%和101.7%~104.3%,相对标准偏差为2.6%~7.7%。以不低于3倍的信噪比估算DHBMA、3-HPMA、CEMA和SPMA的检出限分别为0.062、0.031、0.020和0.003 μg/L。应用该方法检测了37例吸烟和非吸烟者的24 h尿液样本,结果发现吸烟者尿液中3-HPMA、SPMA和CEMA的平均含量比非吸烟者高3到6倍。 相似文献
8.
A method using automated on-line solid phase extraction (SPE) directly coupled to liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed for the analysis of six pharmaceuticals by isotope dilution. These selected pharmaceuticals were chosen as representative indicator compounds and were used to evaluate the performance of the on-line SPE method in four distinct water matrices. Method reporting limits (MRLs) ranged from 10 to 25 ng/L, based on a 1 mL extraction volume. Matrix spike recoveries ranged from 88 to 118% for all matrices investigated, including finished drinking water, surface water, wastewater effluent and septic tank influent. Precision tests were performed at 50 and 1000 ng/L with relative standard deviations (RSDs) between 1.3 and 5.7%. A variety of samples were also extracted using a traditional off-line automated SPE method for comparison. Results for both extraction methods were in good agreement; however, on-line SPE used approximately 98% less solvent and less time. On-line SPE coupled to LC-MS/MS analysis for selected indicators offers an alternative, more environmentally friendly, method for pharmaceutical analysis in water by saving time and costs while reducing hazardous waste and potential environmental pollution as compared with off-line SPE methods. 相似文献
9.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments. 相似文献
10.
Simple and rapid quantitative determination of fatty-acid-based biofuels is greatly important for the study of genetic engineering progress for biofuels production by microalgae. Ideal biofuels produced from biological systems should be chemically similar to petroleum, like fatty-acid-based molecules including free fatty acids, fatty acid methyl esters, fatty acid ethyl esters, fatty alcohols and fatty alkanes. This study founded a gas chromatography-mass spectrometry (GC-MS) method for simultaneous quantification of seven free fatty acids, nine fatty acid methyl esters, five fatty acid ethyl esters, five fatty alcohols and three fatty alkanes produced by wild-type Synechocystis PCC 6803 and its genetically engineered strain. Data obtained from GC-MS analyses were quantified using internal standard peak area comparisons. The linearity, limit of detection (LOD) and precision (RSD) of the method were evaluated. The results demonstrated that fatty-acid-based biofuels can be directly determined by GC-MS without derivation. Therefore, rapid and reliable quantitative analysis of fatty-acid-based biofuels produced by wild-type and genetically engineered cyanobacteria can be achieved using the GC-MS method founded in this work. 相似文献
11.
固相萃取-气相色谱/质谱法同时测定涂料中的8种有机锡 总被引:6,自引:0,他引:6
建立了一种固相萃取(SPE)前处理、气相色谱-质谱(GC-MS)法同时测定涂料中8种有机锡的方法。样品采用阳离子交换固相萃取小柱净化,最佳固相萃取条件为:固相萃取小柱分别用5mL甲醇、7mL洗脱液(氯化铵、甲醇、冰乙酸的混合溶液)预洗,10mL甲醇活化;将用甲醇稀释的涂料样品上样后,用5mL甲醇淋洗,抽干2min,7mL乙酸-氯化铵甲醇溶液(10:90,V/V)洗脱溶液洗脱。洗脱液用四乙基硼化钠溶液衍生后,气相色谱-质谱法进行定性定量分析。结果表明:以标准加入法计算回收率,在1.68%-16.84%添加范围内,平均回收率在85%-105%之间,相对标准偏差均小于12%。 相似文献
12.
Eugenie Sin Sing Tan Yu Bin Ho Mohamad Pauzi Zakaria Puziah Abdul Latif Nazamid Saari 《International journal of environmental analytical chemistry》2015,95(9):816-832
This study features the simultaneous extraction and quantification of 18 pharmaceuticals and personal care products (PPCPs). This is a pioneering method for the quantification of acetaminophen, sulfamethoxazole, diclofenac, atenolol, metoprolol, diethyltoluamide and oxybenzone in atmospheric pressure chemical ionisation mode. The method was validated for high repeatability and reproducibility with relative standard deviations less than 10%. Instrument quantification limits for PPCPs were within the range of 0.05–1.0 µg L?1, and the method quantification limits (MQLs) for ultrapure water were within the range of 0.3–15 ng L?1. All samples were extracted using Oasis© hydrophilic–lipophilic balanced cartridges with optimised sample size and extraction conditions. Good accuracy was demonstrated, with solid-phase extraction recoveries above 80% for most PPCPs. In environmental matrices, the MQLs for river water, sewage treatment plant (STP) effluent and STP influent were 4–25, 10–153 and 38–386.5, respectively. The method was successfully applied to investigate occurrences of persistent PPCPs in Malaysian river and sewage samples. 相似文献
13.
固相萃取-超快速液相色谱-串联质谱法同时测定血液中的4种苏丹染料 总被引:1,自引:0,他引:1
建立了血液样品中4种苏丹染料(苏丹Ⅰ、Ⅱ、Ⅲ和Ⅳ)的固相萃取-超快速液相色谱-串联质谱(UFLC-MS/MS)测定方法。样品经乙腈涡旋振荡提取,上清液加等体积水稀释混匀后移入C18固相萃取小柱净化,采用Agilent Eclipse Plus C18色谱柱(100 mm×2.1 mm,1.8 μm)以0.1%(v/v)甲酸水溶液和0.1%(v/v)甲酸乙腈溶液为流动相梯度洗脱分离,电喷雾电离(ESI)正离子多反应监测模式进行定量分析。讨论了苏丹Ⅲ和苏丹Ⅳ的偶氮基团E-Z光学异构现象,并对影响因素进行了分析。结果4种苏丹染料在0.1~20.0 μg/L范围内线性关系良好,相关系数均大于0.999;在低、中、高3个加标水平的平均回收率为93.0%~108.2%,相对标准偏差为4.8%~9.5%;方法的检出限(LOD)为0.06 μg/L,定量限(LOQ)为0.2 μg/L。本方法准确、快速、灵敏,可用于血液样品中苏丹类染料的检测分析。 相似文献
14.
Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography-mass spectrometry 总被引:1,自引:0,他引:1
A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l. 相似文献
15.
Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds. 相似文献
16.
A multiresidue method for screening of emerging contaminants in aquatic environments was developed. The method was based on sample pretreatment with solid phase extraction (SPE) and analysis with an ultra performance liquid chromatograph-time-of-flight mass spectrometer (UPLC-TOF-MS). The method was optimized and tested with standard solutions of model compounds containing 84 pesticides and pharmaceuticals. Four different SPE sorbents were evaluated to gain maximum recovery for the analytes. For the final procedure a combination of two different sorbents was chosen. In spite of high matrix suppression, the method quantification limits (MQLs) were acceptable. Therefore, the method can be used for screening known target compounds. The applicability of the method for posttarget and nontarget screening will be reported later. To preliminarily assess the quantitative performance of the method, some compounds in wastewater effluent were quantified using the standard addition method. Three pesticides and eight pharmaceuticals were found in concentrations up to ~2200 ng/L. 相似文献
17.
Rodrigues JA Barros AS Carvalho B Brandão T Gil AM Ferreira AC 《Journal of chromatography. A》2011,1218(7):990-996
Beer stability is a major concern for the brewing industry, as beer characteristics may be subject to significant changes during storage. This paper describes a novel non-targeted methodology for monitoring the chemical changes occurring in a lager beer exposed to accelerated aging (induced by thermal treatment: 18 days at 45 °C), using gas chromatography-mass spectrometry in tandem with multivariate analysis (GC-MS/MVA). Optimization of the chromatographic run was performed, achieving a threefold reduction of the chromatographic time. Although losing optimum resolution, rapid GC runs showed similar chromatographic profiles and semi-quantitative ability to characterize volatile compounds. To evaluate the variations on the global volatile signature (chromatographic profile and m/z pattern of fragmentation in each scan) of beer during thermal deterioration, a non-supervised multivariate analysis method, Principal Component Analysis (PCA), was applied to the GC-MS data. This methodology allowed not only the rapid identification of the degree of deterioration affecting beer, but also the identification of specific compounds of relevance to the thermal deterioration process of beer, both well established markers such as 5-hydroxymethylfufural (5-HMF), furfural and diethyl succinate, as well as other compounds, to our knowledge, newly correlated to beer aging. 相似文献
18.
建立了固相萃取-气相色谱-串联质谱同时测定水果中11种三唑类杀菌剂残留的方法。采用乙腈匀浆提取样品中的待测组分,经固相萃取法(SPE)净化,采用气相色谱-串联质谱在多反应监测(MRM)模式下进行测定,外标法定量。分别对水果样品进行4个水平(10、50、100、250 μg/kg)的加标回收试验,回收率为82.6%~117.1%,相对标准偏差小于10%,定量限(LOQ,以信噪比(S/N)为10计)为0.8~3.4 μg/kg。结果显示该方法的背景干扰低,灵敏度高,定量限低于国家标准及有关文献报道值,适合橘子等水果中三唑类杀菌剂的同时测定。 相似文献
19.
在线固相萃取净化-液相色谱-串联质谱法测定猪肉中10种大环内酯类抗生素 总被引:1,自引:0,他引:1
建立了在线固相萃取净化-液相色谱-串联质谱检测猪肉中10种大环内酯类抗生素残留的方法。样品经过乙腈提取,提取液40℃旋蒸至干后,分析物用2 mL磷酸盐缓冲液溶解,溶解液经在线固相萃取柱(HLB柱)富集净化,甲醇洗脱,然后转移至XBridge BEH C18色谱柱上,以10 mmol/L乙酸铵水溶液和乙腈溶液为流动相进行分离,最后用串联四极杆质谱检测。结果表明,10种大环内酯类抗生素在0.1~200μg/L范围内呈现良好的线性关系,相关系数均大于0.990。方法的检出限范围为0.05~0.30μg/kg,定量限范围为0.10~1.00μg/kg;添加水平为0.10~10.0μg/kg时,方法回收率为69.6%~115.2%,相对标准偏差(RSD)10%。该方法可以作为猪肉中大环内酯类抗生素的检测方法。 相似文献
20.
固相萃取-液相色谱-串联质谱法测定蔬菜中4种有机磷农药及其代谢产物 总被引:2,自引:0,他引:2
在蔬菜种植中经常使用的有机磷农药马拉硫磷、甲基对硫磷、敌百虫及乙酰甲胺磷可能转化的主要代谢产物分别为O,O-二甲基二硫代磷酸酯、对硝基酚、敌敌畏及甲胺磷。根据蔬菜色素等基质的含量不同采用不同的净化方法,色素含量高的蔬菜采用活性炭和弗罗里硅土串联固相萃取小柱净化,其他蔬菜采用弗罗里硅土固相萃取小柱净化。色谱分离选择ACQUITY UPLC BEH HILIC色谱柱,以乙腈和5 mmol/L乙酸铵水溶液为流动相进行梯度洗脱,得到的分离效果较好;质谱采用电喷雾正或负离子电离、多反应监测模式检测。液相色谱-质谱检测的基质效应为15.3%~45.1%;4种有机磷农药及其代谢物的方法回收率为76.9%~102.8%,相对标准偏差为5.92%~10.19%;定量限范围为0.001~0.01 mg/L;在0.01~1.00 mg/L范围内线性相关系数为0.9982~0.9999。方法具有良好的回收率、相对标准偏差、定量限及线性关系,适合蔬菜中有机磷及代谢物的检测,应用该检测方法对农贸市场购买的白菜、辣椒、西红柿及洋葱进行了检测。 相似文献