首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A simple and sensitive method for the determination of isophorone in food samples was developed by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS). Isophorone was separated within 10 min by GC-MS using a DB-1 capillary column and detected with selective ion monitoring mode. The HS-SPME using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber provided effective sample enrichment, and was carried out by fiber exposition at 60 degrees C for 45 min. The extracted isophorone was easily desorbed by fiber exposition in the injection port of a capillary GC-MS system, and carryover was not observed. Using this method, the calibration curve of isophorone was linear in the range 20-1000 pg/mL, with a correlation coefficient 0.9996 (n = 18), and the detection limit (S/N = 3) was 0.5 pg/mL. The HS-SPME/GC-MS method showed 25,000-fold higher sensitivity than the direct injection method (1 microL injection). The within-day and between-day precisions (relative standard deviations) at the concentration of 1 ng/mL isophorone were 3.9% and 6.1% (n=5), respectively. This method was successfully applied to the analysis of food samples without interference peaks. The recoveries of isophorone spiked into food sample were above 84% for a 50 or 500 pg/mL spiking concentration. The analytical results of the contents of isophorone in various food samples were presented.  相似文献   

2.
采用聚丙烯酸树脂涂层-固相微萃取-气相色谱-质谱(PA—SPME—GC—MS)联用技术,在优化的萃取条件下检测了城市污水中的苯系物和多环芳烃等芳香烃化合物.该方法的最低检出限达12ng/L水平,相对标准偏差为1.7%~9.8%.  相似文献   

3.
Optimum conditions for headspace solid-phase microextraction (HS-SPME) in the analysis of monomethylmercury (MeHg) have been determined. Sodium tetra(n-)propylborate (NaBPr(4)) is used as derivatization reagent to promote volatility. A simple aluminium bar was used to cool the SPME fiber to about 2 degrees C during the equilibration phase just before extraction. HS-SPME was performed using different fibers. The 100 microm polydimethylsiloxane (PDMS) and 65 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers showed the best results. Although the extraction efficiency for MeHg derivative of the polydimethylsiloxane-Carboxen (PDMS-CAR) fiber is similar to the other fibers, desorption of MeHg derivative from a PDMS-CAR fiber is poor. Factors affecting the HS-SPME process such as adsorption and desorption times, ionic strength (salting-out) and extraction temperature have been evaluated and optimized thoroughly. The highest extraction efficiency for the PDMS fiber was obtained by extraction at a low temperature (2 degrees C) immediately after equilibration at 30 degrees C. With the PDMS-DVB and PDMS-CAR fiber improvement of extraction efficiency at lower temperatures is negligible. Repeated extraction out of the same vial revealed that about 30% of MeHg derivative is extracted from the headspace with a PDMS fiber at 2 degrees C and about 70% with a PDMS-DVB fiber. Repeated extraction with two different fiber coatings showed that the PDMS-CAR fiber also extracts about 70% but that the desorption is incomplete. Attempts to improve the desorption failed due to degradation of the MeHg derivate at high injection temperatures. The limit of detection (3sigma) was 16 pg/L MeHg. The relative standard deviation (n = 8) for 100 pg/L of MeHg was found to be 5%. Linearity of the HS-SPME-GC-atomic emission detection method was established over at least two orders of magnitude in the range 0-2000 pg/L. Recovery of a surface water sample spiked at 2 ng/L was 85%. The suitability of the procedure was demonstrated by analysis of a surface water sample that showed a concentration of 100 pg/L MeHg. The optimized method can be used with standard commercial equipment without further adaptations.  相似文献   

4.
A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.  相似文献   

5.
A simple, rapid and sensitive method for the determination of five estrogens, estrone, 17beta-estradiol, estriol, ethynyl estradiol, and diethylstilbestrol, was developed using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These estrogens were separated within 8 min by HPLC using an XDB-C8 column and 0.01% ammonia/acetonitrile (60/40, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the negative ion mode were optimized for MS/MS detection of the estrogens. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 microL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r > or = 0.9996) was obtained in the concentration range from 10 to 200 pg/mL for all compounds examined. The limits of detection (S/N= 3) of the five estrogens examined ranged from 2.7 to 11.7 pg/mL. The in-tube SPME method showed 34-90-fold higher sensitivity than the direct injection method (5 microL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface water and wastewater samples were collected from the area around Asahi River, and estriol was detected at 35.7 pg/mL in the effluent of a sewage treatment plant. The recoveries of estrogens spiked into river waters were above 86%, except for estriol, and the relative standard deviations were below 0.9-8.8%.  相似文献   

6.
《Analytical letters》2012,45(8):1544-1557
Geosmin (GSM) and 2-methylisoborneol (MIB) were extracted from water samples, adsorbed in organic solvent microdrop by headspace liquid-phase microextraction (HS-LPME), and were analyzed by gas chromatography-mass spectrometry (GC-MS). Influence factors such as the extraction solvent types, headspace and microdrop volumes, stirring rate, equilibrium and extraction time, and ionic strength for HS-LPME efficiency were thoroughly evaluated. Under optimized extraction and detection conditions, the calibration curves of GSM and MIB were linear in the range of 5–1000 ng/L. The detection limits of GSM and MIB were 1.1 and 1.0 ng/L, respectively. Average recoveries of 95.45–113.7% (n = 5) were obtained and method precisions were also satisfactory. Trace levels of the off-flavor compounds at ng/L in tap water and raw water were successfully quantified.  相似文献   

7.
A rapid and simple method of using solid-phase microextraction was developed for determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) in water samples. In this method, the target analyte is extracted from the sample into the polymeric coating of the fused-silica fiber. After exposure, the fiber is thermally desorbed in the heated injection port of the gas chromatograph, and a chromatographic analysis is performed by using low-resolution tandem mass spectrometry. Parameters that may affect the extension of the microextraction process, such as sampling mode, sample volume, temperature, agitation, and sampling time, were studied. Extraction efficiencies for 3 coating fibers were investigated: 100 microm poly(dimethylsiloxane) (PDMS), 65 microm PDMS-divinylbenzene, and 75 microm carboxen-PDMS. Linearity was evaluated (R = 0.999) for a 250-fold concentration range from the fg/mL to the pg/mL level. The 2,3,7,8-TCDD was detected at the fg/mL level when the headspace over the water sample was sampled for 60 min; the limit of detection obtained was better than that of Method 8280B of the U.S. Environmental Protection Agency. The proposed method performed well when applied to the analysis of tap water, lake water, and seawater samples.  相似文献   

8.
成建国  刘开颖  白敏冬  程超  余忆玄  周新颖 《色谱》2015,33(12):1287-1293
2-甲基异莰醇(2-methylisoborneol, 2-MIB)和土臭素(geosmin, GSM)在水源水中大量分泌排放是造成饮用水土霉异味突发事件、引发居民用水恐慌的重用因素之一。使用顶空固相微萃取(HS-SPME)与气相色谱-质谱联用技术(GC-MS)建立了水库水、水库附近土壤、居民自来水中2-MIB和GSM的测定方法。结合正交分析优化了加盐量、萃取温度、萃取时间条件,在电子轰击(EI)-选择离子扫描(SIM)模式下进行了目标物的定性定量分析。结果表明:在5~1000 ng/L范围内,2-MIB和GSM的色谱峰面积与其质量浓度的线性关系良好(r2≥0.998), 2-MIB与GSM的检出限分别为0.72 ng/L和0.34 ng/L,定量限分别为2.40 ng/L和1.13 ng/L;目标物加标水平为10~600 ng/L时,平均回收率为93.6%~107.7%,相对标准偏差(RSD)≤6.1%(n=6)。基于上述方法,对辽宁省某地区水库水、水库附近土壤、居民自来水中的目标物进行检测,结果表明:水库水目标物质量浓度范围为3.0~3.6 ng/L,水库附近土壤中提取的2-MIB为8.1 ng/L、提取的GSM为17.8 ng/L,居民自来水中的目标物未检出。该方法操作简便、准确可靠,灵敏度高,无需有机溶剂,适合于饮用水中2-MIB和GSM的分析检测。  相似文献   

9.
Deng X  Liang G  Chen J  Qi M  Xie P 《Journal of chromatography. A》2011,1218(24):3791-3798
Production and fate of taste and odor (T&O) compounds in natural waters are a pressing environmental issue. Simultaneous determination of these complex compounds (covering a wide range of boiling points) has been difficult. A simple and sensitive method for the determination of eight malodors products of cyanobacterial blooms was developed using automatic purge and trap (P&T) coupled with gas chromatography-mass spectrometry (GC-MS). This extraction and concentration technique is solvent-free. Dimethylsulfide (DMS), dimethyltrisulfide (DMTS), 2-isopropyl-3-methoxypyrazine (IPMP), 2-isobutyl-3-methoxypyrazine (IBMP), 2-methylisoborneol (MIB), β-cyclocitral, geosmin (GSM) and β-ionone were separated within 15.3 min. P&T uses trap #07 and high-purity nitrogen purge gas. The calibration curves of the eight odors show good linearity in the range of 1-500 ng/L with a correlation coefficient above 0.999 (levels=8) and with residuals ranging from approximately 83% to 124%. The limits of detection (LOD) (S/N=3) are all below 1.5 ng/L that of GSM is even lower at 0.08 ng/L. The relative standard deviations (RSD) are between 3.38% and 8.59% (n=5) and recoveries of the analytes from water samples of a eutrophic lake are between 80.54% and 114.91%. This method could be widely employed for monitoring these eight odors in natural waters.  相似文献   

10.
In this study, poly(ethylene glycol) (PEG) grafted onto multi-walled carbon nanotubes (PEG-g-MWCNTs) were synthesized by the covalent functionalization of MWCNTs with hydroxyl-terminated PEG chains. For the first time, functionalized product of PEG-g-MWCNTs was used as selective stationary phase to prepare the sol-gel solid-phase microextraction (SPME) fiber in combination with gas chromatography-flame ionization detector (GC-FID) for the determination of ultra-trace levels of benzene, toluene, ethylbenzene and o-xylene (BTEX) in real water samples. The PEG-g-MWCNTs were characterized by Fourier transform infrared spectra and also thermo-gravimetric analysis, which verified that PEG chains were grafted onto the surface of the MWCNTs. The scanning electron micrographs of the fiber surface revealed a highly porous structure which greatly increases the surface area for PEG-g-MWCNTs sol-gel coating. This fiber demonstrated many inherent advantages, the main being the strong anchoring of the coating to the fused silica resulting from chemical bonding with the silanol groups on the fused-silica fiber surface. The new PEG-g-MWCNTs sol-gel fiber is simple to prepare, robust, with high thermal stability and long lifetime, up to 200 extractions. Important parameters influencing the extraction efficiency such as desorption temperature and time, extraction temperature, extraction time, stirring speed and salt effect were investigated and optimized. Under the optimal conditions, the method detection limits (S/N=3) were in the range of 0.6-3 pg mL(-1) and the limits of quantification (S/N=10) between 2 and 10 pg mL(-1). The relative standard deviations (RSDs) for one fiber (repeatability) (n=5) were obtained from 4.40 up to 5.75% and between fibers or batch to batch (n=3) (reproducibility) in the range of 4.31-6.55%. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples at 20 pg mL(-1) were from 90.21 to 101.90%.  相似文献   

11.
A solvent-free and simple method based on headspace solid-phase microextraction (HS-SPME) was developed in order to determine simultaneously 36 common pesticides and breakdown products (mostly pyrethroids and organochlorine compounds) in soil. The analysis was carried out by gas chromatography with micro-electron-capture detection (GC-microECD). As far as we know, this is the first study about the SPME of pyrethroid insecticides from soil. Factors such as extraction temperature, matrix modification by addition of water, salt addition (% NaCl) and fiber coating were considered in the optimization of the HS-SPME. To this end, a 3 x 2(3-1) fractional factorial design was performed. The results showed that temperature and fiber coating were the most significant variables affecting extraction efficiency. A suitable sensitivity for all investigated compounds was achieved at 100 degrees C by extracting soil samples wetted with 0.5 mL of ultrapure water (0% NaCl) employing a polyacrylate (PA) coating fiber. Using the recommended extraction conditions with GC-microECD, a linear calibration could be achieved over a range of two orders of magnitude for both groups of analytes. Limits of detection (LODS) at the sub-ng g(-1) level were attained and relative standard deviations (RSDs) were found to be lower than 14% for both groups of pesticides. Matrix effects were investigated by the analysis of different soil samples fortified with the target compounds. The method accuracy was assessed and good recovery values (>70%, in most cases) were obtained. The method was also validated with a certified reference material (RTC-CRM818-050), which was quantified using a standard addition protocol. Finally, the proposed HS-SPME-GC-microECD methodology was further applied to the screening of environmental soil samples for the presence of the target pesticides.  相似文献   

12.
A polyvinylimidazole/sol–gel composite is proposed as a novel solid‐phase microextraction fiber to extract five halobenzenes from the headspace of aqueous solutions in combination with gas chromatography with mass spectrometry. The prepared fiber was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The obtained results showed that porous polyvinylimidazole/sol–gel composite was chemically deposited on fused silica fiber. The effect of important extraction parameters including extraction temperature, extraction time, and salt content were investigated. The optimum conditions were as follows: extraction temperature 25°C, extraction time 20 min, and salt concentration 30 w/v%. Detection limits and relative standard deviations of the developed method for halogenated benzenes were below 0.1 pg/mL and 15%, respectively. Repeatability of the proposed method, explained by relative standard deviation, varied between 5.48 and 9.15% (n = 5). The limits of detection (S/N = 3) ranged between 0.01 and 0.10 ng/L using gas chromatography with mass spectrometry with selected ion monitoring mode. For real sample analysis, three types of water samples with different matrices (ground, surface, and tap water) were studied. The optimized procedure was applied to extraction and method validation of halogenated benzenes in spiked water samples.  相似文献   

13.
Koster EH  Bruins CH  de Jong GJ 《The Analyst》2002,127(5):598-602
On-fiber derivatization was used for solid-phase microextraction (SPME) in order to increase the detectability and extractability of drugs in biological samples. Amphetamine, which was used as a model compound, was derivatized with pentafluorobenzoyl chloride (PFBCl) and subjected to gas chromatography with electron capture or mass spectrometric detection. Extraction was performed by direct immersion of a 100 microm polydimethylsiloxane-coated fiber into buffered human urine. On-fiber derivatization was performed either after or simultaneously with extraction. The former procedure gave cleaner chromatograms but the latter turned out to be superior with respect to linearity and repeatability. For the on-fiber derivatization of amphetamine an excess of reagent is required. Because a considerable part of the PFBCl loaded on to the fiber is used up by reaction with matrix compounds and water, a reagent loading time of 5 min was needed to obtain a linear range (r = 0.9756) from 250 pg mL(-1) to 15 ng mL(-1). Due to an interfering matrix compound, the limit of detection was also found to be dependent on the reagent loading time, i.e., the limit of detection for a PFBCl loading time of 5 min is 250 pg mL(-1) whereas that for a 1 min loading time it is 100 pg mL(-1). The relative standard deviation (n = 7) of the method was about 11% at an amphetamine concentration of 1 ng mL(-1). The applicability of the method for the determination of drugs in biological samples is shown.  相似文献   

14.
This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: < 0.1 pg/mL to 350 microg/mL and 3.21 microg/mL to 71.2 microg/mL for caffeine; < 0.1 pg/mL to 32 microg mL and < 0.1 pg/mL to 13.2 microg/mL for theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.  相似文献   

15.
Ji J  Deng C  Shen W  Zhang X 《Talanta》2006,69(4):894-899
In this work, portable gas chromatography-microflame ionization detection (portable GC-μFID) coupled to headspace solid-phase microextraction (HS-SPME) was developed for the field analysis of benzene, toluene, ethylbenzene and xylene (BTEX) in water samples. The HS-SPME parameters such as fiber coating, extraction times, stirring rate, the ratio of headspace volume to sample volume, and sodium chloride concentration were studied. A 65 μm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 900 rpm, 3.0 ml of headspace (1.0 ml water sample in 4.0 ml vial), and 35% sodium chloride concentration (w/v) were respectively chosen for the best extraction response. An extraction time of 1.0 min was enough to extract BTEX in water samples. The relative standard deviation (R.S.D.) for the procedure varied from 5.4% to 8.3%. The method detection limits (MDLs) found were lower than 1.5 μg/l, which was enough sensitive to detect the BTEX in water samples. The optimized method was applied to the field analysis of BTEX in wastewater samples. These experiment results show that portable GC-μFID combined with HS-SPME is a rapid, simple and effective tool for field analysis of BTEX in water samples.  相似文献   

16.
Headspace solid-phase microextraction combined with gas chromatography-ion trap tandem mass spectrometry (HS-SPME-GC-ITMS-MS) method has been developed and studied for the simultaneous determination of 15 organochlorine pesticides (OCPs) and 20 polychlorinated biphenyls (PCBs) in aqueous samples. To perform the HS-SPME polydimethylsiloxane (PDMS) (7, 30 and 100 microm film thickness) and polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers were initially compared on the basis of their absorption capacities for the selected compounds, and PDMS 100 microm film thickness was selected to accomplish the rests of essays. The influence of various parameters on OCPs and PCBs extraction efficiency by HS-SPME was thoroughly studied using GC-electron capture detector (ECD). Parameters such as collision induced dissociation (CID) resonant excitation amplitude and RF storage level were optimized to increase specificity and sensibility for ITMS-MS analysis. The performance of proposed HS-SPME-GC-ITMS-MS methodology with respect to linearity, reproducibility and limit of detection (LOD) was evaluated by water spiked with target compounds. The linear range of most compounds was found to be between 0.01 and 1 ng mL(-1) and the limits of detection were between 0.4 and 26 pg mL(-1). The reproducibility of the method (n = 6), expressed as relative standard deviation (RSD), was between 5 and 21%. Finally, developed procedure was applied to determine selected OCPs and PCBs in river water samples in concentration below 0.1 ng mL(-1) can be easily carried out with ultra-selectivity and precision.  相似文献   

17.
A method was developed for the selective determination of Se4+ in drinkable water by solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). Se4+ was selectively derivatized to ethane, 1,1'-selenobis by reaction with sodium tetraethylborate, extracted by the SPME fiber, and determined by GC/MS. Both headspace (HS)-SPME and direct SPME were studied. The method requires only a few milliliters of sample and 20 min for completion. At 2.0 microg/L concentration, the relative standard deviation was 10.1% for HS-SPME and 9.1% for direct SPME. For HS-SPME, the theoretical detection limit was 81 ng/L and 166 ng/L for direct SPME. The recovery rate was 95%. The method was used to determine Se4+ in 10 tap water samples.  相似文献   

18.
A simple and sensitive method was developed for the simultaneous separation and determination of trace earthy-musty compounds including geosmin, 2-methylisoborneol, 2-isobutyl-3-methoxypyrazine, 2-isopropyl-3-methoxypyrazine, 2,3,4-trichloroanisole, 2,4,6-trichloroanisole, and 2,3,6-trichloroanisole in water samples. This method combined headspace solid-phase microextraction (HS-SPME) with gas chromatography-mass spectrometry and used naphthalene-d(8) as internal standard. A divinylbenzene/carboxen/polydimethylsiloxane fiber exposing at 90°C for 30 min provided effective sample enrichment in HS-SPME. These compounds were separated by a DB-1701MS capillary column and detected in selected ion monitoring mode within 12 min. The method showed a good linearity from 1 to 100 ng L(-1) and detection limits within (0.25-0.61 ng L(-1)) for all compounds. Using naphthalene-d(8) as the internal standard, the intra-day relative standard deviation (RSD) was within (2.6-3.4%), while the inter-day RSD was (3.5-4.9%). Good recoveries were obtained for tap water (80.5-90.6%), river water (81.5-92.4%), and lake water (83.5-95.2%) spiked at 10 ng L(-1). Compared with other methods using HS-SPME for determination of odor compounds in water samples, this present method had more analytes, better precision, and recovery. This method was successfully applied for analysis of earthy-musty odors in water samples from different sources.  相似文献   

19.
Xu Q  Wang M  Yu S  Tao Q  Tang M 《The Analyst》2011,136(23):5030-5037
A simple, rapid and sensitive method for the determination of diethylstilbestrol (DES), dienestrol (DE) and hexestrol (HEX) was developed by using the Nylon 6 nanofibers mat-based solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS). These estrogens were separated within 8 min by LC using an ODS column and methanol/water (80/20, v/v) at a flow rate of 1.0 mL min(-1). Electrospray ionization conditions in the negative ion mode were optimized for MS detection of the estrogens. Under the optimum SPE conditions, all target analytes in 50 mL environmental water samples can be completely extracted by 1.5 mg Nylon 6 nanofibers mat at flow rate of 3.0 mL min(-1) and easily eluted by passage of 500 μL mobile phase. By using the novel SPE-LC/MS method, good linearity of the calibration curve (r(2) ≥ 0.9992) was obtained in the concentration range from 0.10 ng L(-1) to 1.0 mg L(-1) (except for DE which was 0.20 ng L(-1) to 1.0 mg L(-1)) for all analytes examined. The limits of detection (S/N = 3) of the three estrogens ranged from 0.05 ng L(-1) to 0.10 ng L(-1). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several water samples were collected from Jinchuan River and Xuanwu Lake, and in Jinchuan River water DES was detected at 0.13 ng L(-1). The recoveries of estrogens spiked into tap water were above 98.2%, and the relative standard deviations were below 4.78%.  相似文献   

20.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号