首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Bond Elut C18 solid-phase extraction cartridges were used for pre-concentration followed by derivatization with o-phthaldialdehyde-N-acetylcysteine (OPA-NAC) of primary amines in water. Optimal conditions were: conditioning the cartridges with borate buffer pH 10.4, retention of the primary amines, addition of the OPA-NAC(3.7 mmol L–1) 1:1 molar ratio and borate buffer pH 8, elution of the isoindol with MeOH-borate buffer (9:1) pH 10.2 and fluorescence measurement. The equations of the calibration graphs for methylamine, ethylamine, propylamine, butylamine, pentylamine, and -phenylethylamine at excitation=330 nm and emission=440 nm, in the optimal conditions are presented. The solid-phase extraction procedure improved ten times the detection limits of the solution derivatization. Those values are in the 0.01–0.06 mg L–1 interval in function of the amine. Also, it is possible to estimate the total primary aliphatic amine concentration in water, expressed as molar concentration of –NH2 group or –NH2-N mg L–1. On the basis of these studies, the method was applied for the determination of primary amino groups in tap, ground, factory and source water samples.  相似文献   

2.
A method for the determination of methylamine (MA) in aqueous matrices is reported which uses solid-phase microextraction (SPME) for enrichment and derivatization of the analyte, and high performance liquid chromatography (HPLC). The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. The SPME fibres were successively immersed in the samples and in the derivatization solutions to extract MA and FMOC, respectively. After a defined time of reaction, the derivatized analyte was desorbed into the chromatographic system, and chromatographed in a LiChrosphere 100 RP18, i.d., 5 μm, column under gradient elution. In order to improve the MA-FMOC peak profile, a precolumn ( i.d., packed with Hypersil C18 phase, 30 μm) was connected on-line to the analytical column by means of a switching valve. The experimental conditions (including fibre coating, times of adsorption, reaction and desorption, and concentration of reagent) have been optimised, and the results have been compared with those achieved by using a method previously validated for aliphatic amines in which extraction and derivatization were carried into C18 solid-phase extraction (SPE) cartridges. Although less sensitive, the SPME based method allowed the quantification of MA over the range 2.5-10.0 μg/ml with linearity, reproducibility and accuracy comparable to that of the SPE based method, the limit of detection being 0.75 μg/ml. The main advantages of the proposed SPME procedure are: sample handling involved in the extraction and derivatization steps was considerably reduced, it was free organic solvent and non-destructive. Moreover, the proposed conditions allowed the selective determination of MA in the presence of other primary and secondary short-chain aliphatic amines. The utility of the proposed procedure for the quantification of MA in different types of waters is discussed.  相似文献   

3.
A pre-column derivatization method for the sensitive determination of amines using the labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl chloroformate (BCIC-Cl) followed by high-performance liquid chromatography with fluorescence detection has been developed. Identification of derivatives is carried out by high performance liquid chromatography/atmospheric pressure chemical ionization (LC-APCI-MS-MS). The chromophore of 2-(9-carbazole)-ethyl chloroformate (CEOC) reagent is replaced by 1,2-benzo-3,4-dihydrocarbazole-9-isopropyl functional group, which results in a sensitive fluorescence derivatizing reagent BCIC-Cl. BCIC-Cl can easily and quickly label amines. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography and show an intense protonated molecular ion corresponding m/z [MH]+ under APCI in positive-ion mode. The collision-induced dissociation of protonated molecular ion formed a product at m/z 260 corresponding to the cleavage of CH2-OCO bond. Studies on derivatization demonstrate excellent derivative yields over the pH 9.0–10.0. Maximal yields close to 100% are observed with a 3 to 4-fold molar reagent excess. In addition, the detection responses for BCIC derivatives are compared with those obtained using CEOC and FMOC as derivatization reagents. The ratios of IBCIC/ICEOC and IBCIC/IFMOC are, respectively, 1.23–3.14 and 1.25–3.08 for fluorescent (FL) responses (here, I is relative fluorescence intensity). Separation of the derivatized amines had been optimized on reversed-phase Eclipse XDB-C8 column. Detection limits are calculated from 1.0 pmol injection, at a signal-to-noise ratio of 3, are 10.6–37.8 fmol. The mean interday accuracy ranges from 94 to 105% for fluorescence detection with the largest mean %CV<7.5. The mean interday precision for all standards is < 6.0% of the expected concentration. Excellent linear responses are observed with coefficients of > 0.9997. Revised: 12 December 2005 and 13 Febrauary 2006  相似文献   

4.
Summary A method is reported for the determination of dibutyltin (DBT), diphenyltin (DPhT), tributyltin (TBT), and triphenyltin (TPhT) species at the nanogram per litre concentration level in natural water samples. Analytes were isolated from samples by solid-phase extraction and analysed both off-line and on-line by reversed-phase high-performance liquid chromatography with post-column derivatization and fluorimetric detection. Several SPE cartridges and eluents were evaluated; C18 enrichment and elution with a mixture of methanol, acetic acid, and water was found most suitable. Preconcentration factors up to 250 can be achieved when a 500-mL sample is processed. Detection limits, recovery rates, and the precision of the whole process have been determined. The method has been applied to the determination of organotin species in spiked natural water samples collected on the NW Mediterranean coast. Recovery rates range from 75 to 110% and detection limits are at the low ng L−1 level (1–3 ng Sn L−1 for DPhT, DBT, and PhT and 40 ng Sn L−1 for TBT when 250 mL spiked sea water is processed.)  相似文献   

5.
Summary The use of 2-(9-carbazole)ethyl chloroformate (CEOC) for pre-column derivatization of biogenic amines (BA) has been tested for the first time. The reagent reacts completely with BA within 3 min at ambient temperature in acetonitrile solution to form stable derivatives that are readily analyzed by reversed-phase HPLC. Study of the derivatization conditions revealed derivatization yields to be excellent in borate buffer over the pH range 9.0–10.0. Maximum yields were obtained by use of a three- to fourfold molar excess of reagent. The reaction is extremely tolerant of common buffer salts, no decrease in reaction yield is discernible in well-buffered samples. The emission maximum for the CEOC-derivatives is 360 nm (λ ex = 293 nm). All the derivatives fluoresced strongly and direct injection of the reaction mixture was possible, with no significant disturbance from the major fluorescent reagent degradation by-products, 2-(9-carbazole)ethanol (CEOC-OH) and bis-(2-(9-carbazole)ethyl) carbonate (CEOC)2. Separation of the derivatized BA by high-performance liquid chromatography with gradient elution was tested on a Hypersil BDS C18 column. Excellent response linearity was observed over the concentration range from 0.25 to 94.6 μmol L−1 for the labeled BA. Detection limits were 117–840 fmol at a signal-to-noise ratio of 3∶1. Analysis of BA in a shrimp sauce extract was conducted to demonstrate the applicability of the technique to real sample matrixes; results were satisfactory.  相似文献   

6.
The paper presents a new method based on simultaneous derivatization and air-assisted liquid–liquid microextraction (AALLME) for the extraction and preconcentration of some aliphatic amines prior to gas chromatography-flame ionization detection (GC-FID). Primary aliphatic amines are derivatized and extracted simultaneously by a fast reaction with butylchloroformate (derivatization agent/extraction solvent) under mild conditions. The mixture of butylchloroformate and aqueous sample solution is rapidly sucked into a 10-mL glass syringe and then is injected into a test tube with conical bottom and the procedure is repeated seven times. After centrifuging the resulted cloudy solution, the derivatized analytes in the sedimented phase are determined by GC-FID. The influence of main factors on the efficiency of derivatization/extraction procedure is studied. Under the optimal conditions, the enrichment factors (EFs) for aliphatic amines are obtained in the range of 248–360 and limits of detection (LODs) are between 0.30 and 2.6 μg L−1. The obtained extraction recoveries ranged from 50 to 72% and the relative standard deviation (RSD) was less than 4.8% for intra-day (n = 6) and inter-days (n = 4) precision. The method is successfully applied to determine some aliphatic amines in environmental water samples.  相似文献   

7.
A survey of contamination of surface and drinking waters around Lake Maggiore in Northern Italy with polar anthropogenic environmental pollutants has been conducted. The target analytes were polar herbicides, pharmaceuticals (including antibiotics), steroid estrogens, perfluorooctanesulfonate (PFOS), perfluoroalkyl carboxylates (including perfluorooctanoate PFOA), nonylphenol and its carboxylates and ethoxylates (NPEO surfactants), and triclosan, a bactericide used in personal-care products. Analysis of water samples was performed by solid-phase extraction (SPE) then liquid chromatography–triple-quadrupole (tandem) mass spectrometry (LC–MS–MS). By extraction of 1-L water samples and concentration of the extract to 100 μL, method detection limits (MDLs) as low as 0.05–0.1 ng L−1 were achieved for most compounds. Lake-water samples from seven different locations in the Southern part of Lake Maggiore and eleven samples from different tributary rivers and creeks were investigated. Rain water was also analyzed to investigate atmospheric input of the contaminants. Compounds regularly detected at very low concentrations in the lake water included: caffeine (max. concentration 124 ng L−1), the herbicides terbutylazine (7 ng L−1), atrazine (5 ng L−1), simazine (16 ng L−1), diuron (11 ng L−1), and atrazine-desethyl (11 ng L−1), the pharmaceuticals carbamazepine (9 ng L−1), sulfamethoxazole (10 ng L−1), gemfibrozil (1.7 ng L−1), and benzafibrate (1.2 ng L−1), the surfactant metabolite nonylphenol (15 ng L−1), its carboxylates (NPE1C 120 ng L−1, NPE2C 7 ng L−1, NPE3C 15 ng L−1) and ethoxylates (NPE n Os, n = 3-17; 300 ng L−1), perfluorinated surfactants (PFOS 9 ng L−1, PFOA 3 ng L−1), and estrone (0.4 ng L−1). Levels of these compounds in drinking water produced from Lake Maggiore were almost identical with those found in the lake itself, revealing the poor performance of sand filtration and chlorination applied by the local waterworks.  相似文献   

8.
This paper describes the novel preparation of three kinds of nanofibers [poly(styrene-co-methacrylic acid), poly(styrene-co-p-styrene sulfonate), polystyrene] investigated as solid-phase extraction (SPE) sorbents to extract six compounds (nitrobenzene, 2-naphthol, benzene, n-butyl p-hydroxybenzoate, naphthalene, p-dichlorobenzene) in environmental water by high-performance liquid chromatography. Parameters affecting extraction efficiency were investigated in detail to explore the extraction mechanism of the nanofibers. Under optimized conditions, six compounds followed an excellent linear relationship in the range 10–5,000 ng mL−1 with coefficients of determination (r 2) greater than 0.99. The repeatability (expressed as relative standard deviations) was from 3.0 to 7.0%, corresponding to 2.0 mL of water samples at 25 and 500 ng mL−1 spiked levels for the six compounds. The limits of detection varied from 0.01 to 0.15 ng mL−1 (signal-to-noise ratio of3). A comparison of the SPE using nanofibers as sorbents and the most commonly used octadecylsilica SPE cartridges was carried out in terms of absolute recovery, sensitivity, and reproducibility for the compounds investigated. Finally, the method was applied to four real water samples. The results highlighted the importance of functional groups, and the polarity of nanofibers in controlling sorption of target compounds, and clearly showed that the new method could be a viable and environmentally friendly technique for analyzing pollutants in environmental samples.  相似文献   

9.
Summary The fluorogenic reagent 2-naphthyloxycarbonyl chloride (NOC-Cl) has been used for the automated precolumn derivatization of biogenic amines (BAs) at ambient followed by liquid-chromatographic separation of the derivatives formed. For optimized derivatization samples in 0.5 M borate buffer (pH 9.0) were derivatized with 5 mM NOC-Cl in acetonitrile (MeCN) for 3 minutes. Excess of reagent was scavenged by addition of 20 mM glycine in water. For HPLC a Superspher? RP-18e column and gradient elution using 0.1 M sodium acetate buffer (pH 4.4) and MeCN were used. The NOC-derivatives were detected by fluorescence at an emission wavelength of 335 nm at an excitation wavelength of 274 nm. This method allows the detection of BAs (2-phenylethylamine, putrescine, histamine, cadaverine, tyramine, spermidine, spermine) found in food and beverages (fruit juices, wines, various vinegars, fermented cabbage juice, and salmon). Detection limit of BAs are approximately 49–113 μg kg−1 with the exception of histamine (747 μg kg−1) (injected amounts: 18–41 pg histamine 267 pg), at a signalto-noise ratio of 3:1. The limits of determination are approximately 82–189 μg kg−1 (histamine 1245 μg kg−1) at a signal-to-noise ratio of 5:1. The correlation coefficients of linearity are 0.9910–0.9976. Recoveries from different matrices range from 65 to 109%, depending on the sample investigated. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996.  相似文献   

10.
A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C8) column, followed by fluorimetric detection in 395/495 nm. Different isolation procedures such as octadecylsilane (ODS) and strong cation exchanger (SCX) solid phase extraction (SPE) cartridges and Amberlite CG-120 resin were evaluated. The quantitative characteristics such as recovery, linear dynamic range, correlation coefficient, limit of detection (LOD), and relative standard deviation (RSD) are presented. Using this method, aliphatic amines were analyzed in rain and tap water as well as in waste water.  相似文献   

11.
The oxidation of 1,2,4-triacetoxybenzene (Pyrogallol A) and 3,3′,5,5′-tetramethylbenzydine by air oxygen in presence of tris-(2,2′-dipyridyl)ruthenium(II) as a photosensitizer is studied upon irradiation by visible light. The photooxidation of pyrogallol A was inhibited selectively by benzoate at pH 9–11. The rate of the reaction was not affected by other carboxylic acids but was influenced by short-chained aliphatic amines and transition metals. We developed a semiquantitative procedure for the determination of benzoate by paper chromatography. Therein, a common solution of pyrogallol A and a photosensitizer were used for the visualization followed by irradiation with an incandescent bulb. Benzoate was detected as a light spot with R f ∼ 0.3 against a brown background. The measurement of reflectance intensity for the spot by reflectometry allowed the determination of 1 × 10−5–0.01 M benzoate within a precision of half-order of magnitude. The procedure was validated by comparison to the data of capillary electrophoresis and used to test beverages containing benzoate at levels of 10−4–10−3 M.  相似文献   

12.
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from rainwater by solid-phase extraction (SPE) with three different types of cartridge, and analysis by high-performance liquid chromatography with fluorescence detection, are discussed in this paper. Three cartridges were investigated but only one was suitable. After equilibration in a desiccator for 65–80 h or in ambient air for 90–100 h the SPE cartridges were activated with 5 mL dichloromethane then 5 mL 2-propanol. The volume of sample passed through the cartridges was 50 mL; after loading of the sample the cartridges were dried under vacuum for approximately 20 min by application of a pressure of 15 mbar to the SPE manifold. The PAHs were eluted with 5 mL dichloromethane–hexane, 50:50 (v/v). The flow rate used for conditioning, sample loading, and elution was 2.5 mL min−1, achieved by application of a pressure of 6 mbar. For analysis of PAHs in rainwater, recovery was between 67 and 99%, the relative standard deviation varied between 2 and 5%, and the detection limits of the method were less than 16.9 ng L−1 for several PAHs. These optimum conditions were used for analysis of rainwater collected between June 2002 and May 2003 at two sites in Alsace (eastern France) and 17 PAHs were quantitatively determined. Concentrations varied between 1.6 and 968.1 ng L−1.  相似文献   

13.
A gas chromatography–tandem mass spectrometric (GC-MS/MS) method has been developed for the determination of carbofuran (2,3-dihydro-2,2-dimethylbenzofuran-7-yl methylcarbamate), carbaryl (1-naphthyl-N-methylcarbamate) and their main metabolites in human blood plasma. Optimization of the isolation of the compounds from plasma matrix included the precipitation, denaturation and digestion of plasma proteins. Derivatization was achieved by the use of trifluoroacetic acid anhydride and was optimized for temperature, time and volume of derivatization agent. In the proposed method, a mild precipitation technique was applied using β-mercaptoethanol and ascorbic acid in combination with solid-phase extraction technique using Oasis HLB (Hydrophobic Lipophilic Balance) cartridges for further clean up of samples. Carbamate linkage was not hydrolyzed to its phenol product, but both carbamate phenol and ketones were transformed into trifluoroacetyl derivatives in order to become volatile compounds and were determined using tandem mass spectrometry. The linearity of the method was shown for nine concentrations in the range of 0.50–250 ng mL−1 in fortified plasma aliquots. Limits of detection (LODs) for all compounds ranged from 0.015–0.151 ng mL−1. Inter-day and intra-day assays (RSD) for all compounds, at three concentration levels of 2.5, 25 and 100 ng mL−1 (n=3) in fortified plasma samples were less than 18%. Accuracy (%E r) was calculated at three concentration levels, 8, 80 and 160 ng mL−1 (n=3), and ranged from −12.0 to 15.0%. Matrix effect was evaluated so mean recoveries were calculated for all compounds and ranged from 81–107%. Specificity for the use of this method to biological monitoring studies was achieved including four main metabolites of CF, 1-naphthol and 2-naphthol from the naphthalene metabolism pathways, and both the parent compound of carbofuran and carbaryl. The proposed method was applied to plasma samples of pesticide users.  相似文献   

14.
Geometry optimizations were performed on monoanionic and dianionic clusters of sulfate anions with carbon dioxide, SO4−1/−2(CO2) n , for n = 1–4, using the B3PW91 density functional method with the 6-311 + G(3df) basis set. Limited calculations were carried out with the CCSD(T) and MP2 methods. Binding energies, as well as adiabatic and vertical electron detachment energies, were calculated. No covalent bonding is seen for monoanionic clusters, with O3SO–CO2 bond distances between 2.8 and 3.0 ?. Dianionic clusters show covalent bonding of type [O3S–O–CO2]−2, [O3S–O–C(O)O–CO2]−2, and [O2C–O–S(O2)–O–CO2]−2, where one or two oxygens of SO4−2 are shared with CO2. Starting with n = 2, the dianionic clusters become adiabatically more stable than the corresponding monoanionic ones. Comparison with SO4−1/−2(SO2) n and CO3−1/−2(SO2) n clusters, the binding energies are smaller for the present SO4−1/−2(CO2) n systems, while stabilization of the dianion occurs at n = 2 for both SO4−2(CO2) n and SO4−2(SO2) n , but only at n = 3 for CO3−2(SO2) n .  相似文献   

15.
In this article a new analytical method for the confirmation and quantification of abamectin residues in avocados is described. The method allows a fast analysis of abamectin homologues using microwave assisted extraction (MAE), solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with fluorescence (FL) detection using trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) as derivatizing agents. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1.1 mL min−1 (isocratic elution). Homogenized avocado samples were extracted once with 20 mL acetonitrile:water 4:1 (v/v) in a microwave oven for 26 min at 700 W with a maximum temperature of 80 °C. MAE operational parameters were optimized by means of an experimental design. Extracts were cleaned using C18 SPE cartridges. Average recoveries of the method at four spiked levels (0.005, 0.01, 0.10 and 1.0 mg kg−1) were found to be in the range 90–100% with good precision (RSD < 12%). The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg kg−1, respectively, which are lower than the maximum residue limit (MRL) established by the Spanish and the European legislation in avocados (0.01 mg kg−1). Several avocado samples previously treated with the pesticide were also analyzed.  相似文献   

16.
Liquid chromatography with electrospray mass spectrometry (LC–ESI-MS) instrumentation equipped with a single quadrupole mass filter has been used to determine several benzoylphenylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron). Chromatographic and MS parameters were optimised to obtain the best sensitivity and selectivity for all pesticides. Solid-phase extraction (SPE) using C18 cartridges was applied for preconcentration of pesticide trace levels in river water samples. Recoveries of benzoylphenylurea pesticides from spiked river water (0.01 and 0.025 μg L−1) were between 73 and 110% and detection limits were between 3.5 and 7.5 ng L−1. The applicability of the method to the determination of benzoylphenylurea insecticides in spiked cucumber, green beans, tomatoes and aubergines was evaluated. Samples were extracted into dichloromethane without any clean-up step. The limits of detection ranged from 1.0 to 3.2 ng mL−1 (0.68 and 2.13 μg kg−1 in the vegetable samples). Mean recoveries ranged from 79 to 114% at spiking levels of 0.01 and 0.03 mg kg−1. The method was applied to determine traces of benzoylphenylureas in both river water and vegetable samples with precision values lower than 10%. Interferences due to the matrix effect were overcome using matrix-matched standards.  相似文献   

17.
The reactions of salts of the anion [2-B10H9(N≡CMe)] with aliphatic alcohols ROH (R = C n H2n+1 (n = 1–6) CH2CH2(OEt), Pri, Bui, But, i-C5H11) are studied. These reactions result in hydrolytically stable imidates [2-B10H9{NH=C(OR)Me}]. Their structures were confirmed by the data from mass spectrometry, IR, 1H, 11B, and 13C NMR spectroscopy. The molecular geometry of [2(Z)-B10H9{NH=C(OBu)Me}], which formed in nucleophilic addition reaction of n-butyl alcohol to [2-B10H9(N≡CMe)], was established by X-ray diffraction analysis.  相似文献   

18.
We have developed a novel pre-column fluorescence derivatization reagent for amines, F-trap pyrene. This reagent comprises a fluorescent pyrene moiety, an amine-reactive Marshall linker, and a fluorophilic perfluoroalkyl group known as fluorous tag. When the reagent reacts with aliphatic amines and amino acids to give fluorescent derivatives, the fluorous tag in the reagent is eliminated simultaneously. Therefore, excess unreacted reagents in the derivatization reaction solution still have the fluorous tag and could be removed by fluorous solid-phase extraction selectively before high-performance liquid chromatography (HPLC) analysis. By using this reagent, 13 kinds of aliphatic amine (C2–C16) derivatives can be separated within 40 min by reversed-phase HPLC with gradient elution. In this chromatogram, unreacted reagents peak at around 28 min, greatly decrease after fluorous solid-phase extraction, and do not interfere with the quantification of each amine. The detection limits (S/N = 3) for examined aliphatic amines are 3.6–25 fmol per 20 μL injection. We have also applied this reagent successfully to the amino acid analysis.
Kenichiro TodorokiEmail:
  相似文献   

19.
The reliability of SPME combined with a chemical reaction for the analysis of short-chain aliphatic amines by liquid chromatography has been investigated. Different options to couple SPME and derivatization have been tested and compared: (i) derivatization of the analytes in solution followed by the extraction of the derivatives, (ii) extraction of the analytes and subsequent derivatization by immersing the SPME fibre onto a solution of the reagent, and (iii) extraction/derivatization of the analytes using fibres previously coated with the reagent. Methylamine (MA), dimethylamine (DMA) and trimethylamine (TMA) have been selected as a model of primary, secondary and tertiary amines, respectively. The analytes have been derivatized with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC), and the fibre coating was Carbowax-templated resin (CW-TR). The employment of fibres coated with FMOC to extract and derivatize the analytes was the best option, as compared with the other approaches tested the sensitivity was considerably improved. On the basis of these studies, a new procedure for the determination of MA, DMA and TMA in water is presented. To demonstrate the utility of the proposed conditions data on linearity, accuracy, repeatability and sensitivity are given. Results of the determination of the amines in tap, river and waste water are also presented.  相似文献   

20.
A method was developed for the analysis of four aliphatic diamines by capillary zone electrophoresis using pre-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA)/CN and amperometric detection. The pre-column derivatization reaction conditions including the molar ratio of NDA to amines, the cyanide concentration, the pH value of derivatization buffer, and the reaction time, were investigated. The separation of four derivatives of aliphatic diamines has been optimized by capillary zone electrophoresis (CZE) using end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.7 V versus SCE. The optimum conditions for the separation were 10 mM Tris-H3PO4 (pH 4.0) for the running buffer solution, 15 kV for the separation voltage. The detection limits for diaminopropane, putrescine, cadaverine, diaminohexane were 6.7×10−8, 5.1×10−8, 1.9×10−7 and 3.8×10−7 M, respectively (S/N=3). The proposed method was applied to the determination of aliphatic diamines in a lake water sample by the standard addition method. The recovery of these amines in water was 89.9-107%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏