首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for determining crude fat in animal feed, cereal grain, and forage (plant tissue) was collaboratively studied. Crude fat was extracted from the animal feed, cereal grain, or forage material with hexanes by the Randall method, also called the Soxtec method or the submersion method. The use of hexanes provides for an alternative to diethyl ether for fat extractions. The proposed submersion method considerably decreases the extraction time required to complete a batch of samples compared to Soxhlet. The increase in throughput is very desirable in the quest for faster turnaround times and the greater efficiency in the use of labor. In addition, this method provides for reclamation of the solvent as a step of the method. The submersion method for fat extraction was previously studied for meat and meat products and was accepted as AOAC Official Method 991.36. Fourteen blind samples were sent to 14 collaborators in the United States, Sweden, Canada, and Germany. The within-laboratory relative standard deviation (repeatability) ranged from 1.23 to 5.80% for crude fat. Among-laboratory (including within) relative standard deviation (reproducibility) ranged from 1.88 to 14.1%. The method is recommended for Official First Action.  相似文献   

2.
A Karl Fischer method for determining water (dry matter) in animal feed and forages was collaboratively studied. Water was extracted from animal feed or forage material into methanol-formamide (1 + 1) directly in the Karl Fischer titration vessel by high-speed homogenization. The water was titrated at 50 degrees C with one-component Karl Fischer reagent based on imidazole. Ten blind samples were sent to 9 collaborators in the United States, Canada, and Germany. The within-laboratory relative standard deviation (repeatability) ranged from 1.14 to 6.99% for water or from 0.09 to 0.56% for dry matter. Among-laboratory (including within-) relative standard deviation (reproducibility) ranged from 5.35 to 10.73%, or from 0.44 to 0.77% for dry matter. The authors recommend that the method be adopted as Official First Action by AOAC INTERNATIONAL. A comparable alternative extraction procedure using boiling methanol is also recommended for Official First Action.  相似文献   

3.
A collaborative study was conducted to evaluate the repeatability and reproducibility of the FOSS FoodScan near-infrared spectrophotometer with artificial neural network calibration model and database for the determination of fat, moisture, and protein in meat and meat products. Representative samples were homogenized by grinding according to AOAC Official Method 983.18. Approximately 180 g ground sample was placed in a 140 mm round sample dish, and the dish was placed in the FoodScan. The operator ID was entered, the meat product profile within the software was selected, and the scanning process was initiated by pressing the "start" button. Results were displayed for percent (g/100 g) fat, moisture, and protein. Ten blind duplicate samples were sent to 15 collaborators in the United States. The within-laboratory (repeatability) relative standard deviation (RSD(r)) ranged from 0.22 to 2.67% for fat, 0.23 to 0.92% for moisture, and 0.35 to 2.13% for protein. The between-laboratories (reproducibility) relative standard deviation (RSD(R)) ranged from 0.52 to 6.89% for fat, 0.39 to 1.55% for moisture, and 0.54 to 5.23% for protein. The method is recommended for Official First Action.  相似文献   

4.
A collaborative study was conducted to evaluate the repeatability and reproducibility of an extension of AOAC Official Method 991.20, Nitrogen (Crude) in Milk, to animal feed, forage (plant tissue), grain, and oilseed materials. Test portions are digested in an aluminum block at 420 degrees C in sulfuric acid with potassium sulfate and a copper catalyst. Digests are cooled and diluted, and concentrated sodium hydroxide is added to neutralize the acid and make the digest basic; the liberated ammonia is distilled by using steam distillation. The liberated ammonia is trapped in a weak boric acid solution and titrated with a stronger standardized acid, hydrochloric acid; colorimetric endpoint detection is used. Fourteen blind samples were sent to 13 collaborators in the United States, Denmark, Sweden, Germany, and the United Kingdom. Recoveries of nitrogen from lysine, tryptophan, and acetanilide were 86.8, 98.8, and 100.1%, respectively. The within-laboratory relative standard deviation (RSDr, repeatability) ranged from 0.40 to 2.38% for crude protein. The among-laboratories (including within-) relative standard deviation (RSD(R), reproducibility) ranged from 0.44 to 2.38%. It is recommended that the method be adopted First Action by AOAC INTERNATIONAL. A lower concentration (1% H3BO3) of trapping solution was compared with the concentration specified in the original protocol (4% H3BO3) and was found comparable for use in an automatic titration system in which titration begins automatically as soon as distillation starts. The Study Directors recommend that 1% H3BO3 as an optional alternative to 4% boric acid trapping solution be allowed for automatic titrators that titrate throughout the distillation.  相似文献   

5.
As an important constituent of animal feeds, fiber represents the portion of feeds that is bulky and difficult to digest. The neutral detergent fiber (NDF) method, developed over 30 years ago, is the method of choice for measuring total fiber in forages and other feeds. Several modifications that were made to improve its general applicability to all feeds and others developed in individual laboratories often resulted in variability among laboratories in measuring NDF. The amylase-treated NDF (aNDF) method, therefore, was developed as an accurate and precise method of measuring total insoluble fiber in feeds. A collaborative study was conducted to evaluate the repeatability and reproducibility of the aNDF method over the full range of animal feed materials. Twelve laboratories representing research, feed company, regulatory, and commercial feed testing laboratories analyzed 11 materials as blind duplicates. The materials represented feed matrixes, including animal products; high-protein, high-fat, and high-pectin feeds; oil seeds; grains; heated by-product feeds; and legume and grass hays and silages. Materials selected varied in chemical composition and contained 0-90% aNDF, 1-16% ash, 1-20% crude fat, 1-40% crude protein, and 0-50% starch. Correcting results for changes in blanks and reporting results as ash-free aNDF organic matter (aNDFom) improved the repeatability and reproducibility of results when aNDF was <25%. The within-laboratory repeatability standard deviation (Sr) for percentage aNDFom in feeds varied from 0.21 to 1.82 and among-laboratory reproducibility standard deviation (S(R)) varied from 0.37 to 2.24. The HORRAT was <2 for all materials except feed materials containing >10% fat. However, standard deviations of repeatability and reproducibility for feeds with >10% fat were similar to those of other materials. It is recommended that the aNDF method be accepted for Official First Action status.  相似文献   

6.
A collaborative study was conducted to determine the protein content of raw and processed meat products by a protein-tagging and colorimetric technique. Meat products were prepared following AOAC Official Method 983.18 and analyzed using CEM Corporation's Sprint Rapid Protein Analyzer. Sprint provides protein results by combining an accurately weighed test portion with a known amount of dye-binding agent. The dye-binding agent binds with the lysine, histidine, and arginine, as well as the n-terminus of the proteins commonly found in raw meat and processed meat products. Results are displayed and reported by the Sprint as a percentage (g/100 g) of protein. Ten blind duplicate study samples were sent to 10 collaborating laboratories in the United States. The within-laboratory (repeatability) relative standard deviation (RSD(r)) ranged from 0.91 to 3.04%, and between-laboratories (reproducibility) relative standard deviation (RSDR) ranged from 1.50 to 3.41% for protein. The method is recommended for Official First Action.  相似文献   

7.
In 1996, U.S. Food and Drug Administration regulations mandated the fortification of enriched cereal-grain products with folic acid, thereby emphasizing the need for validated methods for total folates in foods, particularly cereal products. The AOAC Official Methods (944.12, 960.46) currently used for the analysis of folate in foods for compliance purposes are microbiological methods. When the fortification regulations were finalized, no Official AOAC or Approved AACC methods for folate in cereal-grain products were in place. The AOAC Official Method (992.05) for folic acid in infant formula does not incorporate important improvements in the extraction procedure and was not considered suitable for the analysis of folates in foods in general. A microbiological assay protocol using a trienzyme extraction procedure was prepared and submitted for comments to 40 laboratories with recognized experience in folate analysis. On the basis of comments, the method was revised to have the conjugase (gamma-glutamyl-carboxy-peptidase) treatment follow a protease treatment, to include the use of cryoprotected inoculum, and to include the spectroscopic standardization of the standard and optional use of microtiter plates. Thirteen laboratories participated in a collaborative study of 10 required and 10 optional cereal-grain products, including flour, bread, cookies, baking mixes, and ready-to-eat breakfast cereals. The majority of the participating laboratories performed the assay by the standard test tube method; others used the microtiter plate modification for endpoint quantitation with equal success. For the required products, the relative standard deviation between laboratories (RSD(R)) ranged from 7.4 to 21.6% for 8 fortified (or enriched) products compared with expected (Horwitz equation-based) values of 11-20%. RSD(R) values were higher (22.7-52.9%) for 2 unfortified cereal-grain products. For the optional products, the RSD(R) ranged from 1.8 to 11.2% for 8 fortified products. RSD(R) values were higher (27.9-28.7%) for 2 unfortified cereal-grain products. Based on the results of the collaborative study, the microbiological assay with trienzyme extraction is recommended for adoption as Official First Action.  相似文献   

8.
A liquid chromatographic (LC) method for the analysis of sulfamethazine (SMT) in complete swine and cattle feed was collaboratively studied. The method uses post-column derivatization with dimethylaminobenzaldehyde and detection at 450 nm. To 5g finely ground feed, extractant (0.2N HCl + 1.5% diethylamine in 25% methanol), and internal standard solutions are added, and the SMT is extracted by shaking for 1 h. Clarified extract (high-level sample extract diluted to a target concentration of ca 5.5 microg/mL) is chromatographed on a Cla reversed-phase LC column with acetonitrile-2% acetic acid (17 + 83) mobile phase. Sulfamerazine is used as an internal, or surrogate standard to correct for variable recovery of sulfamethazine from a variety of feed matrixes. Six Youden matched-pair samples were sent to 10 collaborators in Korea, Canada, and the United States. Label claims on the commercial feeds ranged from 0.0077 to 0.22% SMT. The SMT mean recovery as determined from the 5 samples with known analyte content was 99.8%. The within-laboratory relative standard deviation (repeatability) ranged from 0.28 to 4.72%. Among-laboratory (including within-laboratory) relative standard deviation (reproducibility) ranged from 1.26 to 4.87%. The authors recommend the method for AOAC INTERNATIONAL Official First Action status.  相似文献   

9.
Penicillins are used universally in both human and veterinary medicine. The European Union (EU) has established maximum residue levels (MRLs) for most ß-lactam antibiotics in milk and animal tissues and included them in the National Residue Monitoring Programs. In this study, a novel method is described for the determination and confirmation of eight penicillins in porcine tissues, milk and animal feed by liquid chromatography–tandem mass spectrometry (LC–MS/MS). To prevent degradation of penicillin residues during workup, a derivatisation procedure was developed, by which penicillins were converted to stable piperidine derivatives. Deuterated piperidine derivatives were synthesised for all relevant penicillins, enabling the use of isotope dilution for accurate quantification. Penicillin residues were derivatised in the crude extract with piperidine and isolated using solid-phase extraction. The penicillin piperidine derivatives were determined by LC–MS/MS. The method was validated at the current MRLs, which range from 25–300 µg kg?1 in muscle and kidney to 4–30 µg kg?1 in milk as well as at the target value of 100 µg kg?1 chosen for animal feed, according to the EU requirements for a quantitative confirmatory method. Accuracy ranged from 94–113% (muscle), 83–111% (kidney) and 87–103% (milk) to 88–116% (animal feed). Intra-day precision (relative standard deviation (RSD)r) ranged from 5–13% (muscle, n?=?18), 4–17% (kidney, n?=?7) and 5–18% (milk, n?=?7) to 11–32% (animal feed, n?=?18). Inter-day precision (RSDRL, n?=?18) ranged from 6–23% (muscle) to 11–36% (animal feed). From the results, it was concluded that the method was fit for purpose at the target MRLs in animal tissue and target levels for animal feed.  相似文献   

10.
An interlaboratory study was conducted for the determination of deoxynivalenol in baby food and animal feed by high-performance liquid chromatography with UV detection. The study included 14 participants representing a cross section of industry, official food control, and research facilities. Mean recoveries reported ranged from 89% (at 120 microg/kg) to 85% (at 240 microg/kg) for baby food and from 100% (at 200 microg/kg) to 93% (at 400 microg/kg) for animal feed. On the basis of the results for spiked samples (blind duplicates at 2 levels), as well as those for naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in analyses of baby food ranged from 6.4 to 14.0% and in analyses of animal feed, from 6.1 to 16.5%. The relative standard deviation for reproducibility (RSDR) in analyses of baby food ranged from 9.4 to 19.5% and in analyses of animal feed, from 10.5 to 25.2%. The HorRat values ranged from 0.4 to 1.0 and from 0.7 to 1.3, for baby food and animal feed, respectively. The method showed acceptable performance for within-laboratory and between-laboratory precision for each matrix, as required by European legislation.  相似文献   

11.
Meat samples are prepared by passing meat through a food chopper, bowl cutter, or food processor, subsampling the meat, and mixing the meat with granular diatomaceous earth. No drying step is necessary. Supercritical CO2 is then used to extract crude fat (which is defined as the components of meat that are extractable with petroleum ether, without digestion of the sample). Extracted material is deposited on glass wool contained in collection vials. After removal of any residual moisture from the extracts, percent crude fat is determined by weight gain of the collection vial. This method has been peer-verified by 3 laboratories, for a wide variety of raw and processed meat products containing 6-28% crude fat. Samples were prepared at the submitting laboratory. Ground samples were split into 4 portions, packed in Whirlpack bags, and immediately frozen. Frozen samples were sent by overnight room temperature, and percent fat was determined (in triplicate), without further processing of the samples. Analysis of the samples was completed within 1 week of sample prepara. tion. On the basis of this study, it can be estimated that all repeatability and reproducibility values are <3.0. Mean accuracy of the direct gravimetric supercritical fluid extraction method for meat samples ranged from +0.22 to -1.41 when the method was compared with AOAC Method 960.39. Interferences are unlikely but would include any nonfat substance that is added to (processed) meat, is soluble in nonpolar solvents, and is present in a quantity that would alter results. This method is expected to perform equally well for all meats with fat content within the stated range of applicability.  相似文献   

12.
粮谷及油籽样品经丙酮-水提取,经去脂和弗罗里硅土固相萃取小柱净化,气相色谱-质谱(GC-MS)选择离子监测模式(SIM)对净化液进行检测;一次进样,便可对粮谷及油籽样品中的9种酰胺类除草剂及常混用的莠去津和嗪草酮等除草剂残留进行准确定量和确证。除草剂回收率为63%~96%;相对标准偏差为2.1%~11.2%;定量下限为0.02~0.05 mg/kg。该法快速、灵敏、准确,各项技术指标均满足农药残留检测的要求。  相似文献   

13.
Selective pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from various food and feed samples was performed with a selective PLE method previously developed for bulk PCBs. The method utilizes sulfuric acid impregnated silica inside the extraction cell to oxidize coextracted fat. Extractions were performed at 100 degrees C with n-heptane for 5 min in two cycles. Data obtained by selective PLE combined with gas chromatography/high-resolution mass spectrometry (GC-HRMS) were compared to concentrations derived from reference laboratories applying conventional sample preparation and GC-HRMS. Experiments performed on spiked vegetable oil, naturally contaminated crude fish oil and oil containing compound feed samples showed good results for these relatively simple matrices. The accuracy was generally +/-20% as compared to spiked levels or to values obtained by the reference laboratories. The precision, measured as the relative standard deviation (RSD) for 2,3,7,8-tetrachlorodibenzo-p-dioxin toxic equivalency values (TEQs), was below 10% in all cases. The method was also tested on naturally contaminated herring tissue, chicken tissue, pork tissue and sepiolitic clay, which all caused some trouble. It was observed that sufficient amounts of sodium sulfate should be used for dehydration of tissue samples and additionally, the cells should not be packed too dense in order to avoid suppressed extraction efficiency. Once this was attended to, satisfactory data could be obtained, except for sepiolithic clay. This study demonstrates that selective PLE can be applied with success to a number of food and feed matrices in analysis of PCDD/Fs and dl-PCBs. Since the fat removal step is on-line, the selective PLE method will reduce time and solvent consumption for sample preparation as compared to traditional clean-up.  相似文献   

14.
An interlaboratory trial for determination of zearalenone (ZON) in baby food and animal feed was conducted. The study involved 39 participants in 16 European Union member states, as well as Turkey, Uruguay, and China, representing a cross-section of industry, and official food control and research institutes. The method is based on immunoaffinity column cleanup followed by high-performance liquid chromatography using fluorimetry (HPLC-FI). The test portion of the sample is extracted with methanol-water (75 + 25, v/v). The sample extract is filtered, diluted, and passed over an immunoaffinity column. ZON is eluted with methanol. The separation and determination of ZON is performed by reversed-phase HPLC-FI with an excitation wavelength of 274 nm and an emission wavelength of 446 nm. Test portions of the samples were spiked at levels of 20 and 30 microg/kg ZON in baby food and at levels of 100 and 150 microg/kg ZON in animal feed. Mean recoveries from each participant ranged from 78 to 119% with an average value of 92% for baby food and from 51 to 122% with an average value of 74% for animal feed. Based on results for spiked samples (blind duplicates at 2 levels), as well as naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in baby food ranged from 2.8 to 9.0%. For animal feed, this value ranged from 5.7 to 9.5%. The relative standard deviation for reproducibility (RSDR) in baby food ranged from 8.2 to 13.3%, and for animal feed this value ranged from 15.5 to 21.4%. The Horwitz ratio (HorRat) in baby food ranged from 0.3 to 0.4, and for animal feed this value ranged from 0.6 to 0.9. The method showed acceptable within- and between-laboratory precision for each matrix, as required by European legislation.  相似文献   

15.
An interlaboratory study was conducted to validate a gas chromatographic (GC) method for determination of 21 organochlorine pesticides, 6 pyrethroid pesticides, and 7 polychlorobiphenyl (PCB) congeners in milk, beef fat, fish, and eggs. The method was performed at low contamination levels, which represent relevant contents in food, and is an extension of the European standard (method NF-EN-1528, Parts 1-4). It enlarges the applicable scope of the reference EN method to pyrethroid pesticides and proposes the use of solid-phase extraction (SPE) as a cleanup procedure. Cryogenic extraction was made, and SPE cleanup was performed with 2 successive SPE cartridges: C18 and Florisil. After injection of the purified extract onto a GC column, residues were measured by electron capture detection. Food samples (liquid milk, beef fat, mixed fish, and mixed eggs) were prepared, tested for homogeneity, and sent to 17 laboratories in France. Test portions were spiked with 27 pesticides and 7 PCBs at levels from 26 to 45, 4 to 27, 31 to 67, and 19 to 127 ng/g into milk, eggs, fish, and fat, respectively. Based on results for spiked samples, the relative standard deviation for repeatability ranged from 1.5 to 6.8% in milk, 3 to 39% in eggs, 4.5 to 12.2% in fish, and 7 to 13% in fat. The relative standard deviation for reproducibility ranged from 33 to 50% in milk, 29 to 59% in eggs, 31 to 57% in fish, and 30 to 62% in fat. This method showed acceptable intra- and interlaboratory precision data, as corroborated by HORRAT values at low levels of pesticide and PCB contamination. The statistical evaluation of the results was performed according to the International Organization for Standardization (ISO; ISO 3534 standard) and 5725-2 Guideline.  相似文献   

16.
The Embrapa Cattle-Southeast research unit conducts a program to compare the results provided by laboratories that perform animal feed analyses. Fifty-two laboratories, representing all the Brazilian regions, have participated in the program. The assays included are those normally carried out by animal nutrition laboratories on animal feed and mineral supplements, a total of 22 different analyses. Four rounds of the program are performed annually. Each package provided to the laboratories for testing contains three kinds of animal feed (three each of forage and commercial feed), along with three mineral supplements. For the evaluation of assigned values and standard deviation, the median and robust standard deviation of the participants’ results are used. This paper reports the experience in coordinating the Brazilian interlaboratory comparison exercise.  相似文献   

17.
A collaborative study was performed to determine the reproducibility of a method for the determination of methylcellulose (MC) and hydroxypropyl methylcellulose (HPMC) in food. These widely used food gums possess unusual solubility characteristics and cannot accurately be determined by existing dietary fiber methods. The new method uses the enzyme-digestion procedure of AOAC Official Method 991.43. Digestate solutions must be refrigerated to fully hydrate MC or HPMC. The chilled solutions are filtered and analyzed by size-exclusion liquid chromatography. Collaborating laboratories received 28 samples containing MC or HPMC in the range of 0-100%. The sample set included blind duplicates of 5 food matrixes (bread, milk, fish, potato, and powdered juice drink). Cochran and Grubbs tests were used to eliminate outliers. For food samples containing MC, values for within-laboratory precision, repeatability relative standard deviation (RSDr), ranged from 4.2 to 16%, and values for among-laboratories precision, reproducibility relative standard deviation (RSDR), ranged from 11 to 20%. For HPMC samples, RSDr values ranged from 6.4 to 27%, and RSDR values ranged from 17 to 39%. Recoveries of MC and HPMC from the food matrixes ranged from 78 to 101%. These results show acceptable precision and reproducibility for the determination of MC and HPMC, for which no Official AOAC Methods exist. It is recommended that this method be adopted as AOAC Official First Action.  相似文献   

18.
Abstract

Trace amounts of iodine in thirty-eight cereal grain samples cultivated at different locations in Austria were determined for the first time in this study by radiochemical neutron activation analysis. For the dissolution of cereal grain samples and standard reference materials, two different procedures, alkaline and acidic dissolution, were applied in the presence of an iodine carrier. Rapid and simple dissolution procedure with acidic solution was demonstrated in this study. The analytical values in the cereal grain as well as in the standard reference materials obtained by the different dissolution procedures were in good agreement within one standard deviation. The iodine in cereal grains and the standard reference materials ranged from 0.002 to 0.03 μg g?-1 and 0.0015 to 0.30 μg g?-1, respectively. The distribution of relative standard deviation (RSD) for iodine concentration below 0.01 μg g?-1 were 21% and 24% of all data for the range 1–10% RSD and 11–20% RSD, respectively. The RSD for 0.1 μg g?1 of iodine concentrations were around 10%  相似文献   

19.
This collaborative study was conducted to determine the total monomeric anthocyanin concentration by the pH differential method, which is a rapid and simple spectrophotometric method based on the anthocyanin structural transformation that occurs with a change in pH (colored at pH 1.0 and colorless at pH 4.5). Eleven collaborators representing commercial laboratories, academic institutions, and government laboratories participated. Seven Youden pair materials representing fruit juices, beverages, natural colorants, and wines were tested. The repeatability relative standard deviation (RSDr) varied from 1.06 to 4.16%. The reproducibility relative standard deviation (RSDR) ranged from 2.69 to 10.12%. The HorRat values were < or = 1.33 for all materials. The Study Director recommends that the method be adopted Official First Action.  相似文献   

20.
A rapid and simple method is developed for the simultaneous determination of ochratoxin A, toxin T-2, deoxynivalenol, and zearalenone by gas chromatography with electron capture detection; the method is applicable to grain, products of its processing, feed premixes, and meat in concentration ranges 0.05–5 mg/kg (0.01–2 mg/kg for ochratoxin A and 0.03–3 mg/kg for T-2). The micotoxins were extracted from samples with acetonitrile; the extracts were purified by the QuEChERS method; and derivatives of target analytes were obtained with trifluoroacetic anhydride. The overall duration of analysis was 1–1.5 h; the relative standard deviation of the results did not exceed 8%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号