High temperature gas chromatography and gas chromatography/mass spectrometry are used in the characterization of complex natural mixtures of permethylated oligosaccharides released from proteins or lipids. The high resolution allows separation of isomeric compounds and the mass range extends to oligosac-charides around molecular mass 2000 daltons or 10 sugar residues for isomalto-oligosaccharides. The mass spectra of permethylated oligosaccharide alditols from mucin glycopeptides are very informative and the approach allows a simple and rapid characterization of these complex components.  相似文献   

2.
Summary The paper describes the possibilities of on-line selective sampling as an on-line fraction technique for the analysis of essential oils.Selective sampling is a micro-separation method, on-line with on-column injection, carried out directly in the syringe body by means of a selective elution of the sample through a fraction cartridge.The paper reports a method of both preparing and standardizing silica gel cartridges, and illustrates through some examples the results of some elution series of solvents on different essential oils.Dedicated to Prof. Dr. A. Liberti on the occasion of his 70th birthday.  相似文献   

3.
4.
Retention gaps with different polarity treatments were evaluated for reversed phase solvents. Aminopropyl- and cyanopropyl-deactivated retention gaps showed the best results for methanol-water mixtures. A reversed phase packed fused silica capillary LC column is connected on-line with a capillary gas chromatography column. The combination was used for the analysis of diazepam in urine. Volume overloading on packed fused silica columns without loss of too much efficiency was demonstrated for propranolol.  相似文献   

5.
The applicability of dynamic headspace analyses for viscous liquids and solid samples is demonstrated. Some comments on the usefulness of this technique for quantifying volatiles in polymeric matrices are made.  相似文献   

6.
Extracolumn band broadening in multidimensional systems utilizing flow switching is clearly undesirable. In certain cases, i.e. capillary recycle gas chromatography, the success of an experiment is contingent on the minimization of pre- and post-column dispersion of the peaks. Knowledge of these sources of peak distortion is necessary to optimize the experimental design. A system that extracts statistical parameters from real chromatographic peaks is discussed and used to evaluate band broadening in a capillary recycle experiment.  相似文献   

7.
国内气相色谱近年的进展   总被引:17,自引:0,他引:17  
傅若农 《分析试验室》2003,22(2):94-107
本文对近三年国内学者在气相色谱方面的研究和应用作了综述 ,国内学者的研究基本和国际上气相色谱方面的研究类似 ,在全二维气相色谱、快速气相色谱 ,微型气相色谱仪、新型气相色谱固定相和色谱柱的溶胶 凝胶涂渍技术领域的研究方面作出了贡献。有关气相色谱的应用研究中 ,介绍了大量在药物分析、食品分析、环境分析、石油和石化分析和化工产品及高聚物分析等领域中应用的题目和摘要  相似文献   

8.
9.
In the gas chromatographic analysis of complex biological samples, the most time-consuming and error-prone steps are the pretreatment required for isolation and purification of the compounds of interest and, for most analytes, the derivatization to chemically and thermally stable compounds with high volatility. These wet-chemical steps are usually carried out manually, and for routine analysis of large numbers of samples they are often rate-limiting. A dedicated automated derivatizer has been constructed, the employment of which significantly reduces the time required for manual labor and increases the reproducibility of derivatization and hence the accuracy of analysis.  相似文献   

10.
11.
The introduction of selected fractions from a liquid chromatograph into a gas chromatograph has been described; however, analyses were performed by off-line experiments requiring collection and reinjection of the separate fractions or by on-line procedures where disadvantageously, only a fraction of the separated peak or a well resolved component in a mixture could be introduced into a gas chromatograph. This disadvantage is overcome by the apparatus and method described in this paper, which utilizes a multidimensional chromatography system employing a high efficiency, packed capillary LC column coupled on-line to a capillary gas chromatograph. The liquid chromatograph (so designed) can act as a highly efficient clean-up or chemical class fractionation step prior to introduction into the gas chromatograph, significantly reducing sample preparation times in many applications. Thus minor components in a complex matrix can be determined without prior sample clean-up, an example of which is the determination of polychlorinated biphenyls in a complex hydrocarbon matrix.  相似文献   

12.
About three years ago, fused silica capillary columns were introduced in the Quality Control Laboratory of the Shell refinery/chemical complex at Pernis. In general, long, thick-film, wide-bore capillary columns are used together with low split ratios and hydrogen as carrier gas. These conditions enable the analysis of relatively large sample amounts, resulting in low detection limits for the minor components without overloading by the major components, while still maintaining a satisfactory resolution. A number of applications are shown, such as the analysis of complex mixtures, the determination of trace impurities and the analysis of residual volatiles in polymers.  相似文献   

13.
It is of fundamental importance to know the true composition of the essential oil produced by the secretory structures of a plant, both from a biogenetic and a chemotaxonomic point of view. This paper considers a method which combines direct sampling with on-column CGC and studies the oils directly from the secretory structures: some examples are given (Humulus lupulus L., Tagetes erecta L., and Tagetes patula L.). For each plant, the composition of the distilled oil is compared to that obtained by direct sampling, and a photograph of the secretory structures taken by electroscanning microscopy is given.  相似文献   

14.
15.
16.
Summary A conventional pyrolysis gas chromatography system has been adapted to the analysis of vapours. A Curie point pyrolysis wire is used as a holder for granular active carbon on which the sample can be adsorbed. Desorption is achieved in the pyrolysis unit, but no pyrolysis occurs. The present study reports on the completeness of adsorption by the sampler and on the degree of release of adsorbate from it.  相似文献   

17.
Three main problems have to be solved in process gas chromatography: psychological, technical and economic. A simple concept already used with success for fifteen years by the author, called the Deferred Standard, is an answer for process GC and, to some extent, laboratory GC as well. That the injection of a pure compound in each analytical sequence is reproducible demonstrates the good working order of PGC. Accurate quantitative results may be obtained because the gas density balance is used as a calibrator detector for determining the relative response factors of the components of interest with respect to the Deferred Standard. By suppressing any calibration standards in process and laboratory chromatography, the Deferred Standard may reveal itself as a time and money saving technique.  相似文献   

18.
A comparison is made between dichlorosilanes and cyclic siloxanes as starting materials in the synthesis of stationary phases for capillary gas chromatography (CGC) and supercritical fluid chromatography (SFC). Siloxanes containing one or more of the side groups methyl, vinyl, phenyl, and cyanoethyl in various ratios were synthesized and compared. These phases were characterized by chromatographic (gel permeation, GPC), spectroscopic (IR, 1H NMR, 29Si NMR), and thermal (DSC) methods. Coated fused silica columns were evaluated with respect to polarity, crosslinkability with several free-radical initiators, and thermal stability. A new liquid phase, 7% cyanoethyl, 7% phenyl, 1% vinyl methyl polysiloxane is shown to be more polar than OV-1701, more temperature stable, easily crosslinked and suitable for use in supercritical fluid chromatography.  相似文献   

19.
近两年国内气相色谱的应用进展(Ⅰ)   总被引:6,自引:0,他引:6  
傅若农男,1930年出生,1953年毕业与北京大学化学系,到1998年退休前一直在北京理工大学(前身为北京工业学院)工作,1986年晋升为教授,并被国务院学位委员会评定为第三批博士生导师。多年来从事色谱分析方面的教学和研究工作,研究方向为:气相色谱和毛细管气相色谱新固定相,  相似文献   

20.
The multipurpose cold injector described in this paper represents a solution for an universal sampling system for high resolution gas chromatography. The system is modular and is built around the Carlo Erba cold on-column injector provided with secondary cooling. An auxiliary module, easily fixable on the bottom of the on-column injector, creates a temperature programmable vaporizing chamber making the system also suitable for cold split-splitless injections or solvent venting prior to the sample transfer into the capillary. The system can be operated manually or in a fully automatic mode using the auto-sampler for cold on-column injections. The experimental data illustrate its benefits and limitations.  相似文献   