首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary The preparation of an immobilized stationary phase based on Carbowax 20M is described. The stationary phase cross-linking was carried out with Desmodur N 75 or Desmodur L 75, pluriisocyanates. The properties of the prepared stationary phases are compared.  相似文献   

2.
Summary Capillary columns coated with acid-modified poly-(ethylene glycol)-type immobilized stationary phases have been studied. The thermostability and chromatographic behaviour of the columns and the stability of the coated films after washing with different solvents were investigated.  相似文献   

3.
Summary The chromatographic performance of newly developed dicyanobiphenyl polysiloxane stationary phases were evaluated and compared with the performance of other polar stationary phases, including the previously reported monocyanobiphenyl polysiloxanes. Due to the unique combination of polarizable biphenyl and polar cyano functionalities in the side chains of the flexible polysiloxane backbone, and by virtue of their mild liquid crystalline properties, the new stationary phases provide excellent resolution of a wide variety of analytes, both polar and nonpolar, in both GC and SFC. They can be easily coated and cross-linked in open tubular columns, and the resultant columns demonstrate excellent efficiency and performance at temperatures up to 280–300°C. The new stationary phases exhibit enhanced selectivities for various types of isomeric compounds.  相似文献   

4.
Summary Carbowax 20M poly(ethylene glycol) stationary phase was immobilized on Chromosorb W by cross-linking with pluriisocyanate. The properties of the prepared packing material were investigated. Column efficiencies of 10,960 and 7,510 theoretical plates/meter were obtained for n-pentadecane and 1-heptanol, respectively.  相似文献   

5.
Mesomorphic biphenylcarboxylate esters were coupled via flexible aliphatic hydrocarbon spacers to a polysiloxane backbone. The influence of spacer length, percent mesomorphic substitution, and crosslinking of the stationary phase on liquid-crystalline transition temperatures and on chromatographic performance was investigated. Unique selectivity and good efficiency over a wide temperature range for gum and cross-linked liquid-crystalline phases were demonstrated by the separation of various isomeric polycyclic aromatic compounds.  相似文献   

6.
Summary A coating of silicone SE-54 on Chromosorb W has been converted to an analytically stable, immobilized stationary phase layer by cross-linking with an organic peroxide. Up to 10% by weight has been applied in this manner. Excellent high temperature qualities are exhibited, such as low bleeding and good base line stability, during typical analyses.Poly (2,6-dimethyl-p-phenylene oxide) has also been crosslinked as a surface coating on Chromosorb W with an organic peroxide. From 3 to 4% by weight has been immobilized in this way. The resultant packing material, following high temperature conditioning, has been examined for use as an adsorbent of trace substances, similar to the applications to which such adsorbents as Tenax GC have commonly been applied, e.g. trace analysis of air. It appears to exhibit satisfactory properties for this analytical purpose.  相似文献   

7.
8.
9.
A new mixed crosslinking agent composed of dicumyl peroxide and tetra(methylvinyl)cyclotetrasiloxane was used to prepare fused silica capillary columns with in situ crosslinked stationary phases including PEG-20M, SE-54, and OV-1. These columns proved to have good thermostability and inertness. As examples of potential applications a mixture of isomers of nitrotoluene and dinitrotoluene, and pyrolyzates of polystyrene were separated by using these columns.  相似文献   

10.
11.
12.
Summary The use of polysiloxanes with cyano or thiol groups as stationary phases for complexation gas chromatography is discussed. The polymers were obtained via polycondensation followed by polymerisation of the corresponding dichloro- or dimethoxy-silanes. Both the phases were modified by bonding transition metal chlorides with were modified by bonding transition metal chlorides with cyano (CuCl2 or CoCl2) and thiol groups (NiCl2 or CoCl2). The phases were examined in order to determine their application to the analysis of ethers, thioethers and ketones. Due to the presence of lone electron pairs on oxygen or sulphur atoms, the compounds should be capable of specific interacting with the electron-withdrawing centre of the liquid stationary phases. A number of retention parameters (retention indices, molecular retention indices and specific retention volume) were determined, which allowed characterisation of specific interactions between the bonded metal and the compound analysed. The results also enabled assessment of the influence of the structure of the compounds on their retention. The measurements were also carried out for the phases with free SH and CN groups as reference phases. The work demonstrates that the phases obtained may be useful for effective separations.  相似文献   

13.
Summary Immobilization of silicone stationary phases, OV-1701 vinyl and OV-225 vinyl, on Chromosorb W-AW support was achieved in a simple procedure using ozone as an initiator. A column efficiency of 2400 theoretical plates/meter was obtained.  相似文献   

14.
15.
This article describes a method of preparing immobilized stationary phases which has arisen from the authors' work on polysiloxane deactivation of fused silica capillaries. Although acid treatment is often omitted with fused silica capillaries, there are good reasons for hydrothermal treatment of this column material. Use of Grob's peroxide method gave immobilized 0.25 μm films of SE-54; lowering of the immobilization temperature permitted immobilization of 0.1 μm films of the same phase.  相似文献   

16.
Summary Two crown ethers, di(tert-butylbenzo)-propyl-15-crown-5 polysiloxane (PSO-DTB-15C5) and dibenzo-propyl-15-crown-5 polysiloxane (PSO-DB-15C5) have been synthesized and coated onto fused-silica capillary columns. The chromatographic characteristics, including column efficiency, polarity, phase transition temperature, operating temperature range and selectivity, were studied.Excellent selectivity was obtained for the separation of polar position isomers, especially phenol and dinitrotoluene isomers. The separation mechanism is discussed.  相似文献   

17.
A comparison is made between dichlorosilanes and cyclic siloxanes as starting materials in the synthesis of stationary phases for capillary gas chromatography (CGC) and supercritical fluid chromatography (SFC). Siloxanes containing one or more of the side groups methyl, vinyl, phenyl, and cyanoethyl in various ratios were synthesized and compared. These phases were characterized by chromatographic (gel permeation, GPC), spectroscopic (IR, 1H NMR, 29Si NMR), and thermal (DSC) methods. Coated fused silica columns were evaluated with respect to polarity, crosslinkability with several free-radical initiators, and thermal stability. A new liquid phase, 7% cyanoethyl, 7% phenyl, 1% vinyl methyl polysiloxane is shown to be more polar than OV-1701, more temperature stable, easily crosslinked and suitable for use in supercritical fluid chromatography.  相似文献   

18.
和永瑞  齐美玲 《色谱》2020,38(4):409-413
发展高选择性固定相是实现气相色谱(GC)高效分离样品组分及其分析测定的关键。近年,材料科学的快速发展促进了新型色谱固定相的研究和应用。该文综述了近5年有关多孔材料、石墨烯及类似物、三聚茚类材料和蝶烯类材料等作为GC固定相的研究进展,并对GC固定相研究进行了总结和展望。  相似文献   

19.
Novel monomeric and polymeric liquid crystalline compounds were synthesized as stationary phases for gas chromatography (GC) and supercritical fluid chromatography (SFC). Monomeric liquid crystalline compounds were used in packed column gas chromatography for the separation of isomeric aromatic compounds and insect sex pheromones. Liquid crystalline polymers possess long nematic ranges and a uniform coating was easily achieved in glass and fused silica capillaries, which could stand temperatures up to 250°C in GC and pressures of 200 MPa at 160°C in SFC. The columns provide excellent selectivity and resolution for fused ring aromatic compounds such as the isomers anthracene and phenanthrene or triphenylene and chrysene.  相似文献   

20.
The influence of gaseous hydrogen chloride on the efficiency and thermal stability of a Ucon LB-550-X stationary phase film has been studied under various working conditions. The efficiency of capillary columns was found to be unchanged or even increased, and the upper working temperature increased by 40–50°C. Nor did the action of hydrogen chloride change the polarity of the columns studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号