首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
A layer of elemental silicon has been deposited on the surface of stainless steel tubing by means of chemical vapor deposition (CVD). Two kinds of capillary column were prepared from the deactivated tubing: cross-linked, silanol-terminated polydime-thylsiloxane wall coated open tubular (WCOT) columns and molecular sieve 13X porous layer open tubular (PLOT) columns. Unlike fused silica capillary columns, stainless steel WCOT and PLOT columns can be operated at temperatures in excess of 400°C. High temperature simulated distillation has been performed successfully with a macro bore WCOT column and rapid PNA (paraffin, naphthene, and aromatic) analysis with a multidimensional gas solid chromatographic (GSC) system using PLOT columns.  相似文献   

4.
The characterization of heavy petroleum fractions is essential for the design and improvement of cracking plants converting heavy feedstock into valuable “white” products. Conventional simulated distillation methods using packed columns are unsuitable for this purposes, being limited to boiling points up to about 600°C. The method presented is able to cover a boiling points interval ranging from about 150°C up to around 800°C. It employs a short, nonpolar, highly thermostable capillary column routinely operated at temperatures around 430°C. The analytical system is based on a high temperature versions of a fully automatic, capillary dedicated gas chromatograph. The experimental data demonstrate that cold on-column injection is the sole sampling system suitable for such heavy compounds. The conversion of the retention times into boiling points, based on the use of low molecular weight polyethylenes, is extremely reliable, as demonstrated by the excellent retention time reproducibilities. The lower part (up to 550–600°C TBP) of the boiling point distribution curves of heavy petroleum fractions obtained on capillary columns fits well with the corresponding distribution curves based on packed column data. For the petroleum fractions fully eluted from the column the quantitative results obtained either using internal standards or by direct processing of the elution curves are in excellent agreement (less than 0.3 weight% differences). The method has been applied to the determination of the true boiling points corresponding to short path vacuum distillation (DISTACT) cut points over 300°C.  相似文献   

5.
It is demonstrated that linear injection characteristics are obtained for a wide boiling point range sample using a temperature-programmed injector in combination with wide-bore fused silica columns. The applicability of the described combination for high temperature simulated distillation is described. The method, using external standardization, gives accurate and repeatable results for different types of samples in the boiling range between 50 and 750°C. The lifetime of the fused silica wide-bore columns was found to be acceptable, viz. over 80 temperature-programmed cycles between ambient and 430°C. Some comments are made on the accuracy of boiling points for normal alkanes.  相似文献   

6.
G. Alexander 《Chromatographia》1980,13(10):651-660
Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns. Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.  相似文献   

7.
8.
9.
10.
Summary Column characteristics affecting the chromatographic behavior of glass and siliceous glass (fused silica) capillary columns include the dimensional uniformity of the column, the physical and chemical characteristics of the column wall and the characteristics of the liquid phase. In the case of the coated column the uniformity and thickness of the liquid phase film are the most important criteria affecting column reproducibility. The paper discusses these factors and their influence on column performance.Presented in part at the Symposium on Standardized Materials for Chromatography, 181 st National American Chemical Society Meeting, Atlanta, Georgia, March 29–April 3, 1981.  相似文献   

11.
Cooled needle sampling using syringes was applied to splitless injection and to simulated distillation analyses. Slight changes of the construction of the previous device are also described. The changes concern the temperature profile within the injector and especially the vaporization insert. Even with the low carrier gas flow through the injector during splitless injection, discrimination by component volatility can be avoided. Precision and accuracy of simulated distillation data obtained with split sampling also can be improved by the cooled needle technique.  相似文献   

12.
Summary Flexibility, strength and adsorption inertness of fused-silica capillaries permits their extensive application for the preparation of micro-packed columns in gas chromatography. Decreasing the column diameter (from 0.5 to 0.15 mm) and the diameter of the sorbent particles (from 100 to 5 μm) results in a marked reduction of the height equivalent to a theoretical plate (HETP), as well as in diminishing the dependence of the HETP on the carrier gas flow rate. The chromatographic characteristics of fused-silica capillary micro-packed columns and open-tubular columns are compared. The fused-silica capillary micro-packed column can be used to advantage for performing rapid and trace analyses and have been shown to be adapted for application in gas-solid chromatography. Separation of organic and inorganic compounds on fused-silica capillary micro-packed columns is illustrated by practical examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

13.
14.
This investigation lays groundwork for the development of an optimization system for sequentially coupled capillary column systems. Three methods for calculating effective capacity factors were obtained from the literature and were tested to determine suitability for optimization use, using four test analytes and two dissimilar columns. This work concentrates on the development of a method for the estimation of optimum column temperatures in sequentially coupled systems.  相似文献   

15.
M. V. Russo 《Chromatographia》1995,41(7-8):419-423
Summary A new method of analysis using headspace gas chromatography with microcapillary columns is proposed. Small diameter (50 μm I.D.) fused-silica capillary columns with non-extractable SE-54 and PS-255 polysiloxane stationary phases were used for the analysis of low boiling organic compounds. The small diameter columns possess the usual very high efficiency so that the method can be employed for the headspace analysis of complex mixtures. The use of short microcolumns reduces the analysis times in comparison to conventional capillary columns. Good performances were obtained in the analysis of volatile compounds in some lemon essential oil, perfumes, and water samples.  相似文献   

16.
M. V. Russo 《Chromatographia》1995,41(5-6):419-423
Summary A new method of analysis using headspace gas chromatography with microcapillary columns is proposed. Small diameter (50 μm I.D.) fused-silica capillary columns with non-extractable SE-54 and PS-255 polysiloxane stationary phases were used for the analysis of low boiling organic compounds. The small diameter columns possess the usual very high efficiency so that the method can be employed for the headspace analysis of complex mixtures. The use of short microcolumns reduces the analysis times in comparison to conventional capillary columns. Good performances were obtained in the analysis of volatile compounds in some lemon essential oil, perfumes, and water samples.  相似文献   

17.
Electroformed nickel tubing was deactivated by chemical vapor deposition of silicon from silane gas and subsequent treatment with cyclooctamethyltetrasiloxane (D4). Standard activity tests performed on the uncoated tube and also on columns coated with crosslinked and uncrosslinked, nonpolar stationary phase, show that good quality flexible columns can be prepared from nickel tubing. The inner surface of the silicon coated tube was characterized by Auger depth profile analysis.  相似文献   

18.
19.
20.
Simulated moving columns technique for chiral liquid chromatography   总被引:1,自引:0,他引:1  
Enantioselectivity of chiral selectors is often relatively low in chiral HPLC. For difficult chiral separations, often only partial resolution is obtained rather quickly by column and mobile phase screening, and, by trial-and-error, additional method optimization is required to achieve complete resolution. This paper describes the development of a novel column-switching technique called "simulated moving columns" (SMC) to quickly achieve complete chiral resolution on columns with limited enantioselectivity. The simulated moving columns (SMC) technique uses two (2) or three (3) short chiral HPLC columns connected in series, and forces the unresolved enantiomers to recycle exclusively through the columns until sufficient resolution is attained. In effect, SMC helps to achieve chiral resolution by virtually multiplying the column length, thus enhancing separation efficiency and resolution, without increasing backpressure. Comparison of the standard non-SMC approach with SMC, and selected applications of chiral separations of pharmaceutical drug molecules are presented. Through measurement and calculation, evaluation of off-column band broadening resulting from a two-column SMC system is provided. The results clearly indicate that SMC eliminates the significant band broadening that is inevitable in the closed-loop recycling techniques currently used in preparative chromatography. Furthermore, SMC is not only useful to enhance resolution for analytical and preparative chiral separation, but also has great potential to enhance recovery and purity for difficult chiral preparative chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号