共查询到20条相似文献,搜索用时 15 毫秒
1.
Several dipeptides have been separated into stereoisomers (enantiomers, diastereoisomers, sequential isomers) by GC on the chiral stationary phase Chirasil-Val. Sufficiently volatile N-TFA-dipeptide methyl esters have been formed by derivatization at ambient temperature, thus avoiding racemization (or epimerization, respectively), and peptide cleavage. This novel approach has proven particularly useful for the determination of stereoisomeric composition of dipeptides in biological fluids. 相似文献
2.
Pulsed discharge helium ionization detector 总被引:1,自引:0,他引:1
Summary A pulsed discharge helium ionization detector (PDHID) (patent pending) for gas chromatography has been developed. This detector uses a non-radioactive pulsed high voltage discharge source for generation of electrons and pulsed collection of these electrons. We have evaluated this detector for the analysis of a wide range of chemical compounds. In this paper the analytes are passed through the discharge since the permanent gases are difficult to ionize. The initial results for the permanent gases indicate that the PDHID can be used as a universal detector of contaminant traces at detection levels on the order of 1–20 pg. The response in this mode of operation is linear over four orders of magnitude.Dedicated to Professor Leslie S. Ettre on the occasion of his 70th birthday. 相似文献
3.
A. J. van Straten 《Journal of separation science》1985,8(9):521-524
About three years ago, fused silica capillary columns were introduced in the Quality Control Laboratory of the Shell refinery/chemical complex at Pernis. In general, long, thick-film, wide-bore capillary columns are used together with low split ratios and hydrogen as carrier gas. These conditions enable the analysis of relatively large sample amounts, resulting in low detection limits for the minor components without overloading by the major components, while still maintaining a satisfactory resolution. A number of applications are shown, such as the analysis of complex mixtures, the determination of trace impurities and the analysis of residual volatiles in polymers. 相似文献
4.
5.
In this study, application of a fused silica capillary column for analysis of toxic anthraquinones and related compounds found in plants was investigated. 相似文献
6.
7.
8.
A cold on-column injection system for capillary gas chromatography (GC) applications was constructed. It was based upon a conventional split/splitless capillary GC inlet, which in turn was a modification of a conventional packed GC column inlet. The heart of the laboratory constructed cold on-column inlet design was a disposable pyrex micro-sampling pipet, which functioned as a needle guide for sample injection. The sample was injected through a traditional GC septum. Construction of the injection system is described and applications are illustrated by separations of a variety of complex mixtures. 相似文献
9.
10.
11.
A gas chromatographic system consisting of one multiport valve, two (hot-wire and flame-ionization) detectors and two analytical columns (one thick-film capillary and one packed adsorption column) is used for the analysis of gas samples containing a number of inorganic compounds (hydrogen, argon, oxygen, nitrogen, carbon monoxide, and carbon dioxide) and organic compounds. Examples include samples containing hydrocarbons up to n-nonane and benzene and toluene. The system also permits the analysis of more complicated samples containing, for example, alcohols, in addition to hydrocarbons. 相似文献
12.
In this study, application of a fused silica capillary column for analysis of major mutagenic heterocyclic compounds found in cooked foods was investigated. 相似文献
13.
14.
High resolution gas chromatography-mass spectrometry has been used to detect anabolic steroids in urine. With fused silica capillary columns connected directly to mass spectrometer, the anabolic steroids could be detected after extraction, hydrolysis, and derivatization with a sensitivity better then 1 ppb. In vivo excretion and metabolism has been investigated for androstanolone, methandriol, oxymesterone, quindenione, and boldenone. 相似文献
15.
16.
Androgen 5α-reductase from the foreskin of 48 boys in prepubertal age was analyzed by evaluation of the apparent Km-and Vmax- values after tissue incubation. Reaction rates were calculated after determination of specific radioactivity of distinct metabolites, by comparison to the radioactivity of the precursor. Reaction products were separated by radio gas chromatography on capillary columns. The chromatography system was based on multicolumn equipment with column switching facilities and a variable splitter at the outlet of the separation column. A radioactivity monitor (gas proportional counter) was used for measurement of radioactivity in the column effluents. An electron capture detector was used for mass detection of steroid acyl derivatives. 相似文献
17.
G. Rutten A. van de Ven J. de Haan L. van de Ven J. Rijks 《Journal of separation science》1984,7(11):607-614
The effect of temperature, water content, and the type of reagent on the silylation of fused silica capillaries was studied by 29Si and 13C CP-MAS NMR. Fumed silica (Cab-O-Sil M5), which is essentially a highly dispersed vitreous quartz with a surface comparable to that of fused silica capillary columns, was selected as a model material. Hexamethyldisilazane (HMDS) and 1,2-diphenyl-1,1,3,3-tetraphenyldisilazane (DPTMDS), which were used as silylation reagents, yielded trimethyl- and dimethylphenylsilyl surface groups respectively at lower temperatures (< 350°C and <250°C respectively). At higher temperatures, increasingly more dimethylsilyl groups are formed, with the silicon bound to two oxygen atoms. This process occurs for DPTMDS at a considerably lower temperature than for HMDS. The formation of silyl groups on the surface and the disappearance of hydroxyl groups are followed independently. The 13C NMR and GC-MS of the reaction products showed that with DPTMDS, the formation of two Si-O-Si links is accompanied by a loss of phenyl groups rather than of methyl groups. After the Cab-O-Sil had been dried over P2O5, the formation of these double links occurred for HMDS only at temperatures above 460°C and for DPTMDS at 400°C. Thus we concluded that water supplies oxygen atoms for double Si-O-Si links (possibly crosslinks) necessary for efficient deactivation. This may explain the less successful silanization of fused silica capillaries because their water content is lower than that of glass capillaries. 相似文献
18.
Chromatographic separation of crude oil components has been performed on a 50 m Chrompack Sil 5 fused silica capillary column, temperature programmed from 10 to 300°C. Approximately 70 peaks eluting before n-nonane (n-C9) and all normal paraffins to n-C19 were identified by a retention time table. Peak areas were converted to weight % using 1-heptene as internal standard and relative response factors. Components were divided into boiling range groups from n-C6 to n-C19. Paraffinic, naphthenic, and aromatic distributions were obtained for the boiling point fractions up to n-C9. Group average densities and molecular weights were calculated from pure component properties up to n-C9. Knowing the density and molecular weight as functions of boiling range group to n-C9, these functions can be extrapolated to n-C19, based on data and correlations from more than 20 distillations of paraffinic North Sea oils adn condensates. The densities and molecular weights of the C10+ and the C20+ residues were calculated to satisfy a balance of weight, volume, and number of moles for the whole sample. Measurements on the residues were used to cross-evaluate the GC method against distillation. The difference in weight was estimated to be less than ± 0.5% in absolute terms for the C10+ residue. The corresponding figure for C20+ was ± 2%. Relatively, calculated densities are within ± 1%, molecular weights within ± 2% compared to direct measurements. Calculations were performed by a BASIC program in a GC interfaced computer. 相似文献
19.
Electron capture gas chromatography with three chemically bonded fused-silica capillary columns (CB-FSCs), OV-17, OV-1701, and SE-52, was performed to evaluate peak separability of 28 organochlorine insecticides and related compounds. Relative retention times and relative peak heights to aldrin were measured and calculated. OV-17 CB-FSC showed the best separability among the three CB-FSCs employed and was applied to analysis of extracts from several soil samples with minimum clean-up procedure. The chromatograms obtained demonstrated steady baseline tracings free of interference. Residue data from soil samples were also tabulated. 相似文献
20.
K. E. Markides B. J. Tarbet C. L. Woolley C. M. Schregenberger J. S. Bradshaw M. L. Lee K. D. Bartle 《Journal of separation science》1985,8(8):378-384
In this work, an investigation of new organosilicon hydride reagents with phenyl functional groups for deactivation and surface modification of fused silica capillary columns is described. Different reagents were tested for their ability to deactivate the fused silica surface, and actual critical surface tension measurements were made using the capillary rise method. The deactivation procedure required lower optimum temperatures than conventional methods. Deactivated capillaries and coated capillary columns were prepared and tested for reproducibility, efficiency, and surface inertness towards basic and acidic compounds at the low nanogram level. 相似文献