首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Measurements of pressure, molar volume and specific heat as functions of temperature in the isotropic (I) phase as well as in the smectic A (SmA) and nematic (N) mesophases of some alkyloxycyanobiphenyl compounds (nOCB, n = 6–10) were carried out using differential thermal analysis under pressure, densitometry, X‐ray powder diffraction and modulated differential scanning calorimetry. Thermodynamic properties, such as latent heats and volume jumps at the different phase transitions, were determined. The coherence of this whole set of data was tested using pressure–temperature data through the slopes associated to their phase transitions, extrapolated at normal pressure in the light of the Clausius–Clapeyron equation.  相似文献   

2.
The retention characteristics of phenyl type stationary phases for reversed phase high performance liquid chromatography are still largely unknown. This paper explores the retention process of these types of stationary phases by examining the retention behaviour of linear PAHs and n-alkylbenzenes on a series of propyl phenyl stationary phases that have changes in their ligand density (1.23, 1.31, 1.97, 2.50 μmol m−2). The aromatic and methylene selectivities increased with increasing ligand density until a point where a plateau was observed, overall the propyl phenyl phases had a higher degree of aromatic selectivity than methylene selectivity indicating that these columns are suitable for separations involving aromatic compounds. Also, retention characteristics relating to the size of the solute molecule were observed to be influenced by the ligand density. It is likely that the changing retention characteristics are caused by the different topologies of the stationary phases at different ligand densities. At high ligand densities, the partition coefficient became constant.  相似文献   

3.
In this work, the development and optimization of a new methodology to analyze grape seed procyanidins based on the application of two-dimensional comprehensive LC is presented. This two-dimensional method involves the use of a microbore column containing a diol stationary phase in the first dimension coupled to either a C18 partially porous short column or a C18 monolithic column in the second dimension. The orthogonal hydrophilic interaction?×?reversed phase liquid chromatography (HILIC×RP-LC) system is interfaced through a ten-port two-position switching valve. The optimized HILIC×RP-LC separation followed by diode array and tandem mass spectrometry detection (HILIC×RP-LC-DAD-MS/MS) made possible the direct analysis of a complex grape seed extract and allowed the tentative identification of 43 flavan-3-ols, including monomers and procyanidin oligomers till a polymerization degree of 7 units with different galloylation degrees. To the best of our knowledge, this is the first time that this powerful analytical technique is employed to characterize complex procyanidin samples. This work successfully demonstrates the great capabilities of the HILIC×RP-LC-DAD-MS/MS coupling for the direct analysis of very complex natural samples like grape seeds.
Figure
Two-dimensional HILIC x RP plot (280 nm) of grape seed procyanidins.  相似文献   

4.
An isocratic online liquid chromatography Fourier transform infrared procedure has been developed for the determination of glycolic acid in cosmetics. The method involves the ultrasound-assisted extraction of glycolic acid from the samples with an acetonitrile:phosphate buffer (25 mM, pH 2.7) (3:97 v/v). The extracts were centrifuged and filtered before their injection into the chromatography system, which was equipped with a C18 column and used a flow rate of 150 microL min(-1). FTIR spectra were acquired using a time-resolved rapid scan mode. To calculate the chromatograms, the spectral area was integrated between 1288 and 1215 cm(-1), with baseline correction established between 1319 and 1150 cm(-1), after correcting for the eluent spectral background. Peak area values of the extracted sample chromatograms were interpolated from an external calibration curve. The method provided a limit of detection of 0.034 mg mL(-1) and a relative standard deviation of 6% for five measurements at the 0.174 mg mL(-1) concentration level. Recovery values obtained by spiking 400 mg of three commercially available samples with amounts of glycolic acid from 3.7 to 9.8 mg ranged between 99.6 and 101%. The results obtained for the commercial samples agree well with their declared concentrations. An attempt to directly determine glycolic acid by attenuated total reflectance measurements using partial least squares calibration showed that results were strongly influenced by compounds coextracted from the matrix.  相似文献   

5.
The selectivity of mass traces obtained by monitoring liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was compared. A number of blank extracts (fish, pork kidney, pork liver and honey) were separated by ultra performance liquid chromatography (UPLC). Detected were some 100 dummy transitions respectively dummy exact masses (traces). These dummy masses were the product of a random generator. The range of the permitted masses corresponded to those which are typical for analytes (e.g. veterinary drugs). The large number of monitored dummy traces ensured that endogenous compounds present in the matrix extract, produced a significant number of detectable chromatographic peaks. All obtained chromatographic peaks were integrated and standardized. Standardisation was done by dividing these absolute peak areas by the average response of a set of 7 different veterinary drugs. This permitted a direct comparison between the LC-HRMS and LC-MS/MS data. The data indicated that the selectivity of LC-HRMS exceeds LC-MS/MS, if high resolution mass spectrometry (HRMS) data is recorded with a resolution of 50,000 full width at half maximum (FWHM) and a corresponding mass window. This conclusion was further supported by experimental data (MS/MS based trace analysis), where a false positive finding was observed. An endogenous matrix compound present in honey matrix behaved like a banned nitroimidazole drug. This included identical retention time and two MRM traces, producing an MRM ratio between them, which perfectly matched the ratio observed in the external standard. HRMS measurement clearly resolved the interfering matrix compound and unmasked the false positive MS/MS finding.  相似文献   

6.
An analytical method for multi-class pharmaceuticals determination in wastewater has been developed and validated. Target compounds were: sulfonamides (sulfadiazine, sulfaguanidine, sulfamethazine, sulfamethoxazole), fluoroquinolones (ciprofloxacin, enrofloxacin, norfloxacin), diaminopyrimidine (trimethoprim), anaesthetic (procaine), anthelmintic (praziquantel and febantel), and macrolide (roxithromycin). The method involves pre-concentration and clean-up by solid-phase extraction (SPE) using Strata-X extraction cartridges at pH 4.0. Target analytes were identified and quantitatively determined by liquid chromatography–tandem mass spectrometry using multiple reaction monitoring (MRM). Recoveries were higher than 50% with relative standard deviation (RSD) below 18.3% for three concentrations. Only for sulfaguanidine was low recovery obtained. Matrix effect was evaluated using matrix-matched standards. The method detection limit (MDL) was between 0.5 and 5 ng L−1 in spiked water samples. The precision of the method, calculated as relative standard deviation, ranged from 0.5 to 2.0% and from 1.4 to 8.3 for intra-day and inter-day analysis, respectively. The described analytical method was used for determination of pharmaceuticals in effluent wastewaters from the pharmaceutical industry.  相似文献   

7.
This paper reports the study of poly(oxyethylene) as a solvent for heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin (PM-β-CD) and the potential of these mixtures for constructing enantioselective gas chromatography columns. Enantioseparations of volatile racemic mixtures using capillaries coated with 10–50% PM-β-CD diluted in Carbowax 20M were evaluated. The influence of the polymer type on retention, separation and reproducibility over a period of time is critically discussed. The poly(oxyethylene)-based columns were also compared to columns prepared by dilution of PM-β-CD in two polysiloxanes, SE-30 and SE-54, at several temperatures. Finally, we evaluated a new stationary phase prepared by crosslinking the chiral selector to the poly(oxyethylene) matrix.  相似文献   

8.
Dispersive liquid–liquid microextraction (DLLME) has been developed for the extraction and preconcentration of diethofencarb (DF) and pyrimethanil (PM) in environmental water. In the method, a suitable mixture of extraction solvent (50 µL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) are injected into the aqueous samples (5.00 mL) and the cloudy solution is observed. After centrifugation, the enriched analytes in the sediment phase were determined by HPLC-VWD. Different influencing factors, such as the kind and volume of extraction and dispersive solvent, extraction time and salt effect were investigated. Under the optimum conditions, the enrichment factors for DF and PM were both 108 and the limit of detection were 0.021 ng mL?1 and 0.015 ng mL?1, respectively. The linear ranges were 0.08–400 ng mL?1 for DF and 0.04–200 ng mL?1 for PM. The relative standard deviation (RSDs) were both almost at 6.0% (n = 6). The relative recoveries from samples of environmental water were from the range of 87.0 to 107.2%. Compared with other methods, DLLME is a very simple, rapid, sensitive (low limit of detection) and economical (only 5 mL volume of sample) method.  相似文献   

9.
10.
Melatonin (N-acetyl-5-methoxytryptamine), the hormonal product of the pineal gland, has recently been reported as a multifaceted free radical scavenger and antioxidant. Melatonin production declines progressively with age. Therefore, supplemental administration or increased intake of melatonin from dietary sources may be beneficial in delaying age-related degenerative conditions. This study aimed to determine melatonin in commonly eaten bakery products based on wheat, rye or spelt flour formulations, which represented the most popular types of bread and roll in Europe. Melatonin was extracted from freeze-dried bread samples with methanol and its content was determined by micro-HPLC system coupled to triple quadrupole mass spectrometry (LC–MS/MS) of target analysis. Melatonin was identified in all types of bread and rolls, however, its content varied significantly, ranging from 0.26 ng/g to 3.21 ng/g of dry matter (DM). The best source of melatonin was mixed wheat-rye bread (average 3.02 ng/g DM) followed by rye bread (average 2.50 ng/g DM), whereas spelt bread, wheat and graham rolls were poor sources (below 0.54 ng/g DM). These findings may help consumers to select bread with high melatonin content. This study showed that micro-HPLC system coupled to triple quadrupole mass spectrometry can be successfully applied for the determination of melatonin in bakery products. Because of the relevance of melatonin as bioactive molecule with implications for food, nutritional sciences and human health, it was of interest to explore its levels in commonly daily taken bakery products.  相似文献   

11.
A computer-assisted method is presented for optimization of mobile phase compositions and development distance in gradient two-step development HPTLC. The method is based on a system which can predict the final Rf values for gradient two-step development from values measured using five preliminary runs. The statistical scanning method is then used for optimization, using Rf difference as the selection criterion. The method was evaluated using a mixture of eight components. Excellent agreement was obtained between predicted and experimental results. Gradient two-step development HPTLC, mobile phase composition optimization, velopment distance optimizationde-  相似文献   

12.
Pesticide metabolite identification is gaining increased attention because of the interest in potential metabolite toxicity. Azoxystrobin is one of the most prevalent pesticide residues in foods in Europe. The majority of azoxystrobin metabolites have been identified using radiolabelled standards, which are either expensive or not readily available. Thus, alternative approaches for metabolite identification are desirable. Here, an LC-MS/MS method for quantifying azoxystrobin and identifying its metabolites using quadrupole-linear ion trap mass spectrometry is reported. Seven metabolites of azoxystrobin were identified 2 and 4 weeks after spraying lettuce with azoxystrobin. Among them, two metabolites are reported for the first time. The hydrolysis, reduction, hydroxylation, photoisomerisation and hydrolytic cleavage of ether bonds are identified as biotransformation processes involved in azoxystrobin metabolism in lettuce.  相似文献   

13.
Phenyl type stationary phases of increasing spacer chain length (phenyl, methyl phenyl, ethyl phenyl, propyl phenyl and butyl phenyl, with 0–4 carbon atoms in the spacer chain, respectively) were synthesised and packed in house to determine the impact that the spacer chain length has on the retention process. Two trends in the aromatic selectivity, qaromatic, were observed, depending on whether the number of carbon atoms in the spacer chain is even or odd. Linear log k′ vs ? plots were obtained for each stationary phase and the S coefficient was determined from the gradient of these plots. For the phenyl type phases, the S vs nc plots of the retention factors of linear polycyclic aromatic hydrocarbons vs the number of rings exhibit a distinct discontinuity that between 3 and 4 rings, which increases with increasing spacer chain length for even phases but decreases for odd phases. Accordingly, we suggest that the retention factors depend differently on the number of carbon atoms in the spacer chain depending on whether this number is even or odd and that this effect is caused by different orientations of the aromatic ring relative to the silica surface.  相似文献   

14.
This paper discusses the effects of adding particulate filler to a system undergoing liquid–liquid thermally induced phase separation (L–L TIPS). While much is known about the growth of droplets in L–L TIPS, little is known about the effect particular fillers have on droplet growth and the final cell size in the resulting microporous membranes. In this work, zeolite particles are shown to have a significant effect on the final cell size of these microporous membranes, the extent of which depends on the particle loading and processing conditions used to form the membrane. Two polymer–diluent–zeolite systems are reported: isotactic polypropylene–diphenyl ether and poly(methyl methacrylate)–cyclohexanol, both with zeolite 4A particles.  相似文献   

15.
Applications of tandem mass spectrometry (MS/MS) techniques coupled with high-performance liquid chromatography (HPLC) in the identification and determination of phase I and phase II drug metabolites are reviewed with an emphasis on recent papers published predominantly within the last 6 years (2002–2007) reporting the employment of atmospheric pressure ionization techniques as the most promising approach for a sensitive detection, positive identification and quantitation of metabolites in complex biological matrices. This review is devoted to in vitro and in vivo drug biotransformation in humans and animals. The first step preceding an HPLC-MS bioanalysis consists in the choice of suitable sample preparation procedures (biomatrix sampling, homogenization, internal standard addition, deproteination, centrifugation, extraction). The subsequent step is the right optimization of chromatographic conditions providing the required separation selectivity, analysis time and also good compatibility with the MS detection. This is usually not accessible without the employment of the parent drug and synthesized or isolated chemical standards of expected phase I and sometimes also phase II metabolites. The incorporation of additional detectors (photodiode-array UV, fluorescence, polarimetric and others) between the HPLC and MS instruments can result in valuable analytical information supplementing MS results. The relation among the structural changes caused by metabolic reactions and corresponding shifts in the retention behavior in reversed-phase systems is discussed as supporting information for identification of the metabolite. The first and basic step in the interpretation of mass spectra is always the molecular weight (MW) determination based on the presence of protonated molecules [M+H]+ and sometimes adducts with ammonium or alkali-metal ions, observed in the positive-ion full-scan mass spectra. The MW determination can be confirmed by the [M-H]- ion for metabolites providing a signal in negative-ion mass spectra. MS/MS is a worthy tool for further structural characterization because of the occurrence of characteristic fragment ions, either MS n analysis for studying the fragmentation patterns using trap-based analyzers or high mass accuracy measurements for elemental composition determination using time of flight based or Fourier transform mass analyzers. The correlation between typical functional groups found in phase I and phase II drug metabolites and corresponding neutral losses is generalized and illustrated for selected examples. The choice of a suitable ionization technique and polarity mode in relation to the metabolite structure is discussed as well.  相似文献   

16.
Li Zhang  Shouzhuo Yao 《Talanta》2010,82(3):984-78
A novel method was developed for the analysis of four β-blockers, namely sotalol, carteolol, bisoprolol, and propranolol, in human urine by coupling carrier-mediated liquid phase microextraction (CM-LPME) to high performance liquid chromatography (HPLC). By adding an appropriate carrier in organic phase, simultaneous extraction and enrichment of hydrophilic (sotalol, carteolol, and bisoprolol) and hydrophobic (propranolol) drugs were achieved. High enrichment factors were obtained by optimizing the compositions of the organic phase, the acceptor solution, the donor solution, the stirring rate, and the extraction time. The linear ranges were from 0.05 to 10.0 mg L−1 for sotalol and carteolol, and from 0.05 to 8.0 mg L−1 for bisoprolol and propranolol. The limits of detection (S/N = 3) were 0.01 mg L−1 for sotalol, carteolol, and bisoprolol, and 0.005 mg L−1 for propranolol. The relative standard deviations were lower than 6%. The developed method exhibited high analyte preconcentration and excellent sample clean-up effects with little solvent consumption and was found to be sensitive and suitable for simultaneous determination of the above four drugs spiked in human urine. Furthermore, the successful analysis of propranolol in real urine specimens revealed that the determination of β-blockers in human urine is feasible using the present method.  相似文献   

17.
The transfer of a gradient method to an isocratic or multistep gradient method employing stationary phase optimized liquid chromatography facilitated a reduction in analysis time by 50% and significantly improved the mass spectrometric detectability of impurities in synthetic thyroid hormones. Four column segments packed with different stationary phases were combined into a single chromatographic column, which allowed the separation and photometric as well as mass spectrometric detection of thyroid compounds in less than 30 min under isocratic- or step gradient elution conditions with 0.10% acetic acid/acetonitrile. Signal instability and baseline drift during detection by negative electrospray ionization time-of-flight mass spectrometry were minimized by optimizing the spray parameters for each individual elution step. This resulted in improved detectabilities and higher mass spectral quality, especially for low-abundance components in the sample mixture. The method was applied to the separation and detection of the low-abundance impurities formed upon the thermal stressing of a sample of synthetic levothyroxine.  相似文献   

18.
This investigation focused on direct comparison of two popular multidimensional liquid–gas chromatography (LC–GC) systems, the Y-interface (retention gap approach) and the syringe-based interface (programmed temperature vaporizer approach). Such transfer devices are structurally very different, and could potentially have a substantial effect on the outcome of a specific application. In this work the application was a topic of much current interest, determination of mineral oil saturated hydrocarbon (MOSH) contamination of a series of food products (rice, pasta, icing sugar, olive oil); the final results were then compared. The two LC–GC methods developed were validated for linearity over the calibration range, analyte discrimination, precision, accuracy, and limits of detection and quantification. No significant differences were found between the two approaches.
Figure
Direct comparison between the Y/LC-GC and the PTV/LC-GC results, on two rice samples  相似文献   

19.
Abstract

The phase transition of a series of homologous liquid-crystalline compounds, nO.m (4-n-alkoxybenzilidene-4′-n-alkylanilines), from the nematic phase to the smectic A phase has been studied by 13C NMR. The order parameters, determined by a two dimensional technique called separated local field spectroscopy combined with off-magic angle spinning, of different molecular segments of these compounds are related linearly to the 13C chemical shifts. Changes in the order parameters of the phenyl rings as well as those of the chains during the SA–N transition depend on the nature of the phase transition. These changes are quantitatively related to the McMillan ratio, which is defined as the ratio between the SA–N transition temperature (T SAN) and the nematic to isotropic transition temperature (T NI), i.e. M = T SAN/T NI. The SA–N transition is first order for M > M TCP, and second order for M < M TCP, where TCP is the tricritical point. The value of M TCP was found to be 0·958 ± 0·004, in excellent agreement with that obtained from spin probe studies (0·959 ± 0·005) reported by Freed and co-workers [1].  相似文献   

20.
Hydrophobic-interaction chromatography coupled on-line with chemical-vapor-generation atomic-fluorescence spectrometry (HIC–CVGAFS), optimized recently for the analysis of thiol-containing proteins under denaturing conditions, has been used to study the chemical reduction of denatured proteins. Four proteins chosen as models (human serum albumin (HSA), bovine serum albumin (BSA), -lactalbumin (-Lac) from bovine milk, and lysozyme from chicken egg (Lys)) were denatured with urea and reduced with dithiothreitol (DTT), with selenol as catalyst. The method is based on derivatization of the –SH groups of proteins with p-hydroxymercurybenzoate (PHMB), followed by HIC separation and post-column on-line reaction of the derivatized reduced, denatured proteins with bromine generated in situ. HgII, derived from rapid conversion of uncomplexed and protein-complexed PHMB, is selectively detected by AFS in an Ar/H2 miniaturized flame after sodium borohydride (NaBH4) reduction to Hg°. The yield of the reduction was studied as a function of reductant concentration, reduction time (tred), and urea concentration. Results showed that the optimum values for DTT and selenol concentrations and for tred were between 1 and 100 mmol L–1 and between 1 and 20 min, respectively, depending on the protein studied. The percentage disulfide bond reduction increases as the urea concentration used for protein denaturation increases, giving a single-step sigmoid increment for single-domain, low-MW proteins (-Lac and Lys), and a two-step sigmoid increment for multi-domain, high MW proteins (HSA and BSA). The shapes of plots of percentage reduced disulfide against urea concentration are characteristic of each protein and are correlated with the location of S–S in the protein. Under the adopted conditions complete protein denaturation is the conditio sine qua non for obtaining 100% S–S reduction. The detection limit for denatured, reduced proteins examined under the optimized conditions was found to be in the range 1–5×10–12 mol L–1 (10–30 pg), depending on the protein considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号