共查询到20条相似文献,搜索用时 15 毫秒
1.
Convection and correlation of coherent structure in turbulent boundary layer using tomographic particle image velocimetry 下载免费PDF全文
The present experimental work focuses on a new model for space–time correlation and the scale-dependencies of convection velocity and sweep velocity in turbulent boundary layer over a flat wall. A turbulent boundary layer flow at Reθ= 2460 is measured by tomographic particle image velocimetry(tomographic PIV). It is demonstrated that arch, cane,and hairpin vortices are dominant in the logarithmic layer. Hairpins and hairpin packets are responsible for the elongated low-momentum zones observed in the instantaneous flow field. The conditionally-averaged coherent structures systemically illustrate the key roles of hairpin vortice in the turbulence dynamic events, such as ejection and sweep events and energy transport. The space–time correlations of instantaneous streamwise fluctuation velocity are calculated and confirm the new elliptic model for the space–time correlation instead of Taylor hypothesis. The convection velocities derived from the space–time correlation and conditionally-averaged method both suggest the scaling with the local mean velocity in the logarithmic layer. Convection velocity result based on Fourier decomposition(FD) shows stronger scale- dependency in the spanwise direction than in streamwise direction. Compared with FD, the proper orthogonal decomposition(POD) has a distinct distribution of convection velocity for the large- and small-scales which are separated in light of their contributions of turbulent kinetic energy. 相似文献
2.
文中提出了用流场的一次曝光像的强度谱作为模板提取杨氏条纹,以获取尖锐的自相关分布的方法,并给出了该方法用于激光散斑测速和粒子像测速技术的计算机模拟结果以及粒子像测速的应用例子。 相似文献
3.
对层析粒子图像测速(PIV)技术中示踪粒子成像部分进行理论分析,并结合真实风洞的相应参数,通过搭建模拟粒子成像平台的方法来进行研究。设计了一套体积为80 mm×100 mm×100 mm的激光照明系统,以提供粒子场的入射光强。建立了示踪粒子的三维成像模型,从而得到层析PIV系统的模拟图像。分析了影响PIV系统成像质量的相关因素。在单像素粒子数为0.007 7的情况下,通过真实粒子图像和模拟粒子图像比较,验证了该方法的正确性。 相似文献
4.
There are several well-known difficulties in forming and analysing holographic particle data in the micrometre and sub-micrometre size range. This paper suggests that these problems can be overcome by using a combination of research techniques. Firstly, it has been found that it is possible to record images of sub-micrometre particles using conventional photographic materials. Essentially, a diffraction limited optical component has been used to provide aberration free particle images. Secondly, the sensitivity of the holographic material has been increased with the use of specialized holographic processing chemicals. Thirdly, it has been found that it is possible to encode holoraphically double, slightly displaced, particle images using a pulse laser. Thus, Young's fringes can be obtained directly from the stored holographic data and the particle velocity can be measured directly from the hologram. Fourthly, the holographic particle data can be automatically analysed using a software programme. Finally, since the data is stored holographically, it is possible to obtain instantaneous three-dimensional particle velocity. This paper demonstrates that it is possible to perform holographic particle image velocimetry automatically, with only a small amount of pre-processing. 相似文献
5.
A high-resolution particle image velocimetry was used to characterize a low Reynolds number turbulent flow in a channel. Experiments were conducted over a sand grain-coated surface of large relative roughness, and the results were compared with measurements over a smooth surface. The roughness perturbation significantly modified the outer layer. Even though the streamwise Reynolds stress shows less sensitivity in the outer layer to the boundary condition, significant enhancements were observed in the wall-normal Reynolds stress and the Reynolds shear stress. These modifications were considered as footprints of the larger-scale eddies transporting intense wall-normal motions away from the rough wall. A quadrant decomposition shows that strong and more frequent ejections are responsible for the larger values of the mean Reynolds shear stress over the rough wall. The results also indicate that spanwise vortex cores with mean vorticity of the same sign as the mean shear are the dominant smaller-scale vortical structures over the smooth and rough walls. A linear stochastic estimation-based analysis shows that the average larger-scale structure associated with these vortices is a shear layer that strongly connects the outer layer flow to the near-wall flow. A proper orthogonal decomposition of the flow suggests that the large-scale eddy is more energetic for the rough wall, and contributes more significantly to the resolved turbulent kinetic energy and the Reynolds shear stress than the smooth wall. 相似文献
6.
Holographic recording techniques have recently been studied as a means to extend two-component, planar particle image velocimetry (PIV) techniques for three-component, whole-field velocity measurements. In a similar manner to two-component PIV, three-component, holographic PIV (HPIV) uses correlation-based techniques to extract particle displacement fields from double-exposure holograms. Since a holographic image contains information concerning both the phase and the amplitude of the scattered field it is possible to correlate either the intensity or the complex amplitude. In previous work we have shown that optical methods to compute the autocorrelation of the complex amplitude are inherently more tolerant to aberrations introduced in the reconstruction process, Coupland, Halliwell, Proc. Roy. Soc. 453 (1960) (1997) 1066. In this paper we introduce a new method of holographic recording and reconstruction that allows a constant image shift to be introduced to the particle image displacement. The technique, which we call conjugate reconstruction, resolves directional ambiguity and extends the dynamic range of HPIV. The theory of this method is examined in detail and a relationship between the image and object displacement is derived. Experimental verification of the theory is presented. 相似文献
7.
This study considers the acoustic streaming in water produced by a lithotripsy pulse. Particle image velocimetry (PIV) method was employed to visualize the acoustic streaming produced by an electromagnetic shock wave generator using video images of the light scattering particles suspended in water. Visualized streaming features including several local peaks and vortexes around or at the beam focus were easily seen with naked eyes over all settings of the lithotripter from 10 to 18 kV. Magnitudes of the peak streaming velocity measured vary in the range of 10-40 mm s(-1) with charging voltage settings. Since the streaming velocity was estimated on the basis of a series of the video images of particles averaged over 1/60s, the time resolution limited by the video frame rate which is 1-2 orders of magnitude larger than driving acoustic activities, measured velocities are expected to be underestimated and were shown a similar order of magnitude lower than those calculated from a simple theoretical consideration. Despite such an underestimation, it was shown that, as predicted by theory, the magnitude of the streaming velocity measured by the present PIV method was proportional to acoustic intensity. In particular it has almost a linear correlation with peak negative pressures (r=0.98683, p=0.0018). 相似文献
8.
An image-shifting technique based on grey-scale classification for particle image velocimetry 总被引:3,自引:0,他引:3
The image-shifting techniques are used to overcome the directional ambiguity of particle image displacement in the measurement of particle image velocimetry (PIV). This paper proposes an image-shifting technique based on grey-scale classification for PIV. By calculating the unified grey-scale statistical frequency of each interrogated unit, the directional ambiguity is resolved without any special requirement of the camera, and the particle image displacement is calculated synchronously. This image-shifting technique can be realized by controlling the difference in the light intensity of two lasers. Using this new technique, a PIV system was developed and used to measure the diesel spray flow. The displacement vector map of fuel particle in the spray flow was obtained, and the structure of the spray flow was investigated. The application confirmed that the image-shifting technique is viable and effective. 相似文献
9.
通过分析询问域大小对底片乳剂颗粒产生的散斑噪声及其散斑噪声对干涉条纹识别的影响,推导出了询问域大小的选择与被测粒子位移量之间的关系,并详细讨论和分析了询问域的大小对所能探测的粒子位移量最大值的限止,以及合理选择询问域大小的依据. 相似文献
10.
This paper presents experimental investigation of upstream roughness and Reynolds number effects on the recirculation region over a smooth forward facing step. The upstream rough wall was produced from 1.5 mm sand grains and the Reynolds number based on step height, Reh, was varied from 2040 to 9130 for both the upstream smooth and rough walls. For the smooth wall, the reattachment length increased monotonically with Reh to an asymptotic value of 2.2 step heights for Reh ≥ 6380. Upstream roughness reduced the reattachment length by 44% because of larger momentum deficit and higher turbulence level in the rough wall boundary layer. The mean velocities and Reynolds stresses were also reduced by roughness. The Reynolds shear stress and production of turbulent kinetic energy showed high negative values at the leading edge of the step indicating counter-gradient diffusion. The implications of these results for standard eddy viscosity models are discussed. 相似文献
11.
Ultrasound speckle image of blood is mainly attributed by red blood cells (RBCs) which tend to form RBC aggregates. RBC aggregates are separated into individual cells when the shear force is over a certain value. The dissociation of RBC aggregates has an influence on the performance of ultrasound speckle image velocimetry (SIV) technique in which a cross-correlation algorithm is applied to the speckle images to get the velocity field information. The present study aims to investigate the effect of the dissociation of RBC aggregates on the estimation quality of SIV technique. Ultrasound B-mode images were captured from the porcine blood circulating in a mock-up flow loop with varying flow rate. To verify the measurement performance of SIV technique, the centerline velocity measured by the SIV technique was compared with that measured by Doppler spectrograms. The dissociation of RBC aggregates was estimated by using decorrelation of speckle patterns in which the subsequent window was shifted as much as the speckle displacement to compensate decorrelation caused by in-plane loss of speckle patterns. The decorrelation of speckles is considerably increased according to shear rate. Its variations are different along the radial direction. Because the dissociation of RBC aggregates changes ultrasound speckles, the estimation quality of SIV technique is significantly correlated with the decorrelation of speckles. This degradation of measurement quality may be improved by increasing the data acquisition rate. This study would be useful for simultaneous measurement of hemodynamic and hemorheological information of blood flows using only speckle images. 相似文献
12.
讨论了粒子像的衍射晕分布并进行了计算机模拟,得出一个结论:当照相机相干传递函数的通带半宽度大于1.6倍粒子夫朗和费零级衍射环半径时,粒子像的自相关函数与照相机孔径无关,且粒子像有较尖锐的自相关峰和较小的衍射晕。这是PIV系统的最佳工作条件。 相似文献
13.
The measurement of spatially resolved velocity distributions is crucial for modelling flow and for understanding properties of materials produced in extrusion processes. Traditional methods for flow visualization such as particle image velocimetry (PIV) rely on optically transparent media and cannot be applied to turbid polymer melts. Here we present optical coherence tomography as an imaging technique for PIV data processing that allows for measuring a sequence of time resolved images even in turbid media. Time-resolved OCT images of a glass-fibre polymer compound were acquired during an extrusion process in a slit die. The images are post-processed by ensemble cross-correlation to calculate spatially resolved velocity vector fields. The results compared well with velocity data obtained by Doppler-OCT. Overall, this new technique (OCT-PIV) represents an important extension of PIV to turbid materials by the use of OCT. 相似文献
14.
15.
16.
In the transitional channel flow, the large-scale intermittent structure of localised turbulence, which is called the turbulent stripe pattern, can be found in the form of stripe arrangement. The structure of the turbulent stripe pattern is an oblique laminar–turbulent banded pattern and is inclined with respect to the streamwise direction. We performed direct numerical simulation at a transitional Reynolds number and very low-rotation numbers, and focused on the turbulent stripe pattern in the plane Poiseuille flow subjected to spanwise system rotation. We captured the turbulent stripe pattern in a rotating channel flow and found the augmentation and diminution of the turbulent stripe pattern were affected by the spanwise rotation. The contents of the discussion are the spatial size of the turbulent stripe pattern on the basis of the instantaneous flow fields, the energy spectra, and various statistics relating to the spanwise velocity component that characterise the turbulent stripe pattern. The turbulent stripe pattern was found to contain kinetic energy that was larger in very weakly rotating flows than in the static system. It was also found that the magnitude of the spanwise secondary flow increases, while the quasi-laminar region is wider at a very lowrotation number. 相似文献
17.
The effects of spatial resolution of planar particle image velocimetry (PIV) on vortex size, swirling strength, circulation and population density characterisation are analysed using a series of experimental and numerical databases. The databases comprise a PIV database of an adverse-pressure-gradient turbulent boundary layer (APG TBL), a PIV database of a zero-pressure-gradient (ZPG) TBL in streamwise-wall-normal planes and streamwise-wall-normal slices of a direct numerical simulation (DNS) of a ZPG TBL. The effects of interrogation window and mesh sizes on the vortex parameters are analysed in the outer region of these flows using different qualitative and quantitative approaches. The quantitative analysis mainly capitalises on the possibility of mimicking the PIV data-sets with the DNS one. These approaches allow us to not only isolate the effects of mesh size and the interrogation window size but also to deduce the combined effects of other measurement errors in PIV. Typical values of mesh size and interrogation window size (0.01–0.03 of the boundary layer thickness) and typical levels of measurement uncertainties have significant effects on the vortex parameters. Moreover, each PIV error source affects the vortex parameters in different and frequently opposite manners. Hence, an optimal selection of measurement parameters such as the interrogation window size is indispensable in order to minimise the effects of spatial resolution and other measurement errors on the vortex parameters. Guidelines are presented in the Conclusions section of this paper. Finally, it is found that all the vortex parameters, when averaged across the outer region, are reasonably comparable in the ZPG and APG TBLs despite the fact that these are very different flows. 相似文献
18.
19.
G. M. Quénot 《显形杂志》2000,3(2):125-133
A Dynamic Programming based Optical Flow technique has been applied to the Particle Image Velocimetry (PIV) problem. It has
been used for the extraction of dense velocity fields in a planar section of a fluid flow illuminated by a thin laser light
sheet. Two (in-plane) components of the velocity vectors can be recovered using a single camera and all three components can
be recovered using two or three cameras. Quantitative performance tests have been carried out on calibrated synthetic image
sequences from the PIV Standard Project of the Visualization Society of Japan (VSJ). Results are presented for the 2D flow
based sequences (STD01 to STD08 Standard Images) and the 3D flow based sequences (STD301, STD302, STD331 and STD337 Standard
Images). The RMS error is within the 2–3% range and within the 4–8% range for recovery of the two-component and the three-component
velocity vectors respectively. 相似文献
20.
多孔介质在生产生活以及科技发展中的应用十分广泛, 随着能源、化工、冶金和原子能等领域技术的发展, 以及近代工农业生产技术的进步, 大量多孔介质的传热传质问题逐渐出现, 进一步促进了多孔介质学科的形成和发展, 使其成为当今科学技术中令人瞩目的研究热点之一. 通过实验获得准确的实验图像和数据, 并使用相应软件对实验所得数据和流体流动图像进行深度分析, 这样既有真实可靠的实际数据, 又有直观的理论的支持, 使对多孔介质的研究更为完善. 实验结合粒子图像测试技术和折射率匹配技术对叉排排列玻璃球多孔介质填充床内的流体流动转变过程进行流场测试, 并提取数据, 采用Tecplot软件对提取数据进行处理, 得出流体流动机理的转变过程. 实验固相为由直径25 mm水晶玻璃球叉排堆积而成的填充床, 液相为65%苯甲醇和35% 无水乙醇配制的匹配液. 液相与固相的折射率都为1.477, 成功消除由于折射率不匹配引起的激光光线偏折. 实验得到雷诺数为 4.7 ≤ Re ≤ 1000时球床内流场图, 对比不同雷诺数时流场和流线变化得出: 随着雷诺数的增加, 流线变得越来越紊乱; 当雷诺数在220以上时, 球床内漩涡在尺寸变化上出现突跃, 在位置和形态变化表现出随机特征, 预示进入了稳定的湍流. 相似文献