首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Wang  Yong  Qu  Jianhang  Li  Shufang  Dong  Ying  Qu  Jianying 《Mikrochimica acta》2015,182(13):2277-2283

We describe an electrochemical sensor for simultaneous determination of hydroquinone (HQ) and catechol (CC). A glassy carbon electrode (GCE) was modified with gold nanoparticles, L-cysteine, and ZnS/NiS@ZnS quantum dots using a layer-by-layer technique. The materials were characterized by X-ray diffractometry, field emission scanning electron microscopy, and electrochemical impedance and Fourier transform infrared spectroscopy. Cyclic voltammetry and differential pulse voltammetry revealed this modified GCE to represent a highly sensitive sensor for the simultaneous determination of HQ and CC. The anodic peak current for HQ at a working voltage of 80 mV (vs. Ag/AgCl) is related to its concentration in the 0.1 to 300 μM range (even in the presence of 0.1 mM of CC). The anodic peak current for CC at a working voltage of 184 mV is related to its concentration in the 0.5 to 400 μM range (even in the presence of 0.1 mM of HQ). The detection limits (at an S/N ratio of 3) are 24 and 71 nM for HQ and CC, respectively. The modified GCE was successfully applied to the determination of HQ and CC in aqueous solutions and gave satisfactory results.

A glassy carbon electrode was modified with gold nanoparticles, ZnS/NiS@ZnS quantum dots and L-cysteine and used for simultaneous determination of hydroquinone and catechol.

  相似文献   

2.
We have synthesized a virtually monodisperse gold-graphene (Au-G) nanocomposite by a single-step chemical reduction method in aqueous dimethylformamide solution. The nanoparticles are homogenously distributed over graphene nanosheets. A glassy carbon electrode was modified with this nanocomposite and displayed high electrocatalytic activity and extraordinary electronic transport properties due to its large surface area. It enabled the simultaneous determination of hydroquinone (HQ) and catechol (CC) in acetate buffer solution of pH?4.5. Two pairs of well-defined, quasi-reversible redox peaks are obtained, one for HQ and its oxidized form, with a 43 mV separation of peak potentials (ΔEp), the other for CC and its oxidized form, with a ΔEp of 39 mV. Due to the large separation of oxidation peak potentials (102 mV), the concentrations of HQ and CC can be easily determined simultaneously. The oxidation peak currents for both HQ and CC increase linearly with the respective concentrations in the 1.0 μM to 0.1 mM concentration range, with the detection limits of 0.2 and 0.15 μM (S/N?=?3), respectively. The modified electrode was successfully applied to the simultaneous determination of HQ and CC in spiked tap water, demonstrating that the Au-G nanocomposite may act as a high-performance sensing material in the selective detection of some environmental pollutants.
Figure
Au-graphene (Au-G) nanocomposites were synthesized through a single-step chemical reduction method. Nearly monodispersed Au nanoparticles were uniformly distributed over the 2D graphene nanosheets without aggregation. The glassy carbon electrode modified with Au-G nanocomposites, Au-G/GCE, shows high resolution capability in simultaneous determination of hydroquinone (HQ) and catechol (CC) in acetate buffer solutions (HAc-NaAc, pH 4.5).  相似文献   

3.
In this paper, we described a rapid, sensitive and selective method for simultaneous voltammetric determination of dihydroxybenzene isomers with a preanodized inlaying ultrathin carbon paste electrode (PAIUCPE). Scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS) and voltammetry were employed to characterize the configuration and electrochemical properties of the electrode. The resulting PAIUCPE exhibited excellent recognition ability towards dihydroxybenzene isomers. Three well‐defined oxidation peaks of catechol (CC), resorcinol (RC) and hydroquinone (HQ) can be identified entirely at the electrode. The oxidation peak potential difference between HQ and CC was 120 mV, CC and RC 430 mV, respectively. The peak currents increased linearly with increasing the concentration of dihydroxybenzene isomers. The proposed electrode can be applied to simultaneous determination of dihydroxybenzene isomers without previous chemical or physical separations.  相似文献   

4.
A new electrochemical sensor based on Poly(Isoleucine) modified glassy carbon electrode decorated with platinum nanoparticles (Pt/Poly(Isoleucine)/GCE) was developed for sensitive individual and simultaneous determination of hydroquinone (HQ) and catechol (CC). Scanning electron microscopy (SEM), Electrochemical impedance spectroscopy (EIS), Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) were performed in order to characterize the Pt/Poly(Isoleucine)/GCE nanocomposite. For simultaneous determination of HQ and CC, Pt/Poly(Isoleucine)/GCE showed wide linear range between the 0.01–100.0 μM. The detection limits were 0.006 μM for HQ and 0.005 μM for CC. The Pt/Poly(Isoleucine)/GC electrode exhibited good sensitivity and reliability in the simultaneous electroanalysis of two isomers in PBS of pH 7.5. The modified electrode was used to detect the isomers in naturel samples.  相似文献   

5.
Simultaneous determination of catechol (CC) and hydroquinone (HQ) were investigated by voltammetry based on glassy carbon electrode (GCE) modified by poly (diallyldimethylammonium chloride) (PDDA) functionalized graphene (PDDA-G). The modified electrode showed excellent sensitivity and selectivity properties for the two dihydroxybenzene isomers. In 0.1 mol/L phosphate buffer solution (PBS, pH 7.0), the oxidation peak potential difference between CC and HQ was 108 mV, and the peaks on the PDDA-G/GCE were three times as high as the ones on graphene-modified glass carbon electrode. Under optimized conditions, the PDDA-G/GCE showed wide linear behaviors in the range of 1 × 10−6−4 × 10−4 mol/L for CC and 1 × 10−6−5 × 10−4 mol/L for HQ, with the detection limits 2.0 × 10−7 mol/L for CC and 2.5 × 10−7 mol/L for HQ (S/N = 3) in mixture, respectively. Some kinetic parameters, such as the electron transfer number (n), charge transfer coefficient (α), and the apparent heterogeneous electron transfer rate constant (k s), were calculated. The proposed method was applied to simultaneous determine CC and HQ in real water samples of Yellow River with satisfactory results.  相似文献   

6.
A stable dihydroxybenzene sensor was fabricated by electrochemical deposition of Zn/Al layered double hydroxide film on glassy carbon electrode (LDHf/GCE). The sensitive and facile electrochemical method for the simultaneous determination of catechol (CA) and hydroquinone (HQ) under coexistence of resorcinol (RE) has been achieved at the LDHf/GCE in phosphate buffer solution (pH 6.5). Under the optimized conditions, the differential pulse voltammetry response of the modified electrode to CA (or HQ) shows a linear concentration range of 0.6 μM to 6.0 mM (or 3.2 μM to 2.4 mM) with a correlation coefficient of 0.9987 (or 0.9992) and the calculated limit of detection is 0.1 μM (or 1.0 μM) at a signal‐to‐noise ratio of 3. In the presence of 50 μM isomer, the linear concentration ranges for CA and HQ are 3.0 μM to 1.5 mM and 12.0 μM to 0.8 mM, respectively. The detection limits are 1.2 μM and 9.0 μM. Further, the proposed method has been performed to successfully detect dihydroxybenzene isomers in analysis of real samples, such as water and tea.  相似文献   

7.
《Analytical letters》2012,45(8):883-893
A multi-wall carbon nanotubes (MWNTs) and cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) modified glassy carbon electrode (MWNTs/Co(II)TPP/GCE) has been prepared. It can be used for individual or simultaneous determination of hydroquinone (HQ) and catechol (CC). The anodic peaks of HQ and CC can be separated well. Owing to the unique properties of MWNTs and special synergistic effect of MWNTs and Co(II)TPP, the modified electrode exhibited a remarkable and stable current response for CC and HQ. The linear ranges for CC and HQ were 1.0–450.0 µmol L?1 and 0.8–400.0 µmol L?1 with detection limits of 0.8 µmol L?1 and 0.5 µmol L?1, respectively. Furthermore, Co(II)TPP, MWNTs, and Co(II)TPP/MWNTs composite were also used to construct modified electrodes and the electrochemical performances were studied.  相似文献   

8.
Graphene was prepared by electrochemical reduction of exfoliated graphite oxide at cathodic potentials, and used to fabricate a graphene-modified glassy carbon electrode (GCE) which was applied in a sensor for highly sensitive and selective voltammetric determination of hydroquinone (HQ). Compared to a bare (conventional) GCE, the redox peak current for HQ in pH 5.7 acetate buffer solution is significantly increased, indicating that graphene possesses electrocatalytic activity towards HQ. In addition, the peak-to-peak separation is significantly improved. The modified electrode enables sensing of HQ without interference by catechol or resorcinol. Under optimal conditions, the sensor exhibits excellent performance for detecting HQ with a detection limit of 0.8?μM, a reproducibility of 2.5% (expressed as the RSD), and a recoveries from 98.4 to 101.2%.
Figure
Graphene based glassy carbon electrode was used to determine hydroquinone in the simultaneous presence of it isomers of catechol (CC) and resorcinol (RC). The desired sensitivity and selectivity is attributed to the good conductivity and excellent electrocatalytic ability of graphene.  相似文献   

9.
A glassy carbon electrode (GCE) was modified with the nickel(II)-bis(1,10-phenanthroline) complex and with multi-walled carbon nanotubes (MWCNTs). The nickel complex was electrodeposited on the MWCNTs by cyclic voltammetry. The modified GCE displays excellent electrocatalytic activity to the oxidation of ascorbic acid (AA). The effects of fraction of MWCNTs, film thickness and pH values were optimized. Response to AA is linear in the 10 to 630 μM concentration range, and the detection limit is 4 μM (at a signal-to-noise ratio of 3:1). The modified electrode was applied to determine AA in vitamin C tablets and in spiked fruit juice.
Graphical Abstract
A simple and sensitive ascorbic acid electrochemical sensor was fabricated by electrodepositing of nickel complex onto multi-walled carbon nanotubes/glassy carbon electrode. The sensor has high selectivity, rapid current response, is easy to construct and can be utilized for ascorbic acid determination.  相似文献   

10.
《Analytical letters》2012,45(7):1289-1298
Abstract

Poly (acridine orange) (PAO) film–modified electrode was prepared by the electrooxidation of Acridine orange on a glassy carbon electrode (GCE) for the detection of hydroquinone in the presence of o‐hydroquinone and m‐hydroquinone. The electrochemical behavior of hydroquinone on the modified electrode was investigated with respect to different solution acidity, scan rate, and accumulation time. A pair of sharp and well‐defined peaks was obtained at 0.45 and 0.42 V [vs. a saturated calomel electrode (SCE)] at the PAO film–modified electrode. The potential difference between this pair of cathodic and anodic peaks was decreased to only 30 mV as compared to the 241 mV that was obtained on the bare glassy carbon electrode (GCE). As to o‐hydroquinone and m‐hydroquinone, their corresponding oxidation peaks appeared at 0.55 V and 0.89 V (vs. SCE), respectively. The oxidation potential differences between these three isomers enabled the separate detection of hydroquinone. Under the optimum experimental situation, the oxidation peak current of hydroquinone was proportional to the concentration at the range of 6.8×10?7–9.6×10?5 M. The detection limit was been estimated as 3×10?7 M with 130 s accumulation. This method was applied to the hydroquinone detection in tap water samples.  相似文献   

11.
In the present study, we report a facile method for preparing a porous MWCNTs/ZIF‐67 nanocomposite with the help of a morphology‐maintained ZIF‐67 in situ growth on multi‐walled carbon nanotubes. Interesting, the MWCNTs/ZIF‐67 nanocomposite demonstrated excellent electrochemical activity for hydroquinone (HQ) and catechol (CC) attribute to the effective interconnections ZIF‐67 crystals and MWCNTs. The analytical curves for HQ and CC obtained by differential pulse voltammetry (DPV) were linear in the range from 0.5 to 100 μM. Benefitting from the excellent conductivity of MWCNTs as well as the high surface area and porosity of ZIF‐67, the advanced nanocomposite displayed good reproducibility, high selectivity and excellent stability, and was successfully employed to assay the content of dihydroxybenzene isomers in the lake water samples.  相似文献   

12.
Selective determination of hydroquinone (HQ) in the presence of catechol (CC) was developed at an over-oxidized poly(hydroquinone) (PHQ) electrode. The electrochemical polymerization of HQ was carried out by potentiostatic method on a glassy carbon electrode. The resulting PHQ was over-oxidized in 0.10?mol/L NaOH solution and thus poly(p-benzoquinone) was obtained. Two dihydroxybenzene isomers, HQ and CC, show different voltammetric behavior at the over-oxidized PHQ electrode. The peak current of HQ is much larger than that of CC with the same concentration, which is attributed to the different position of the hydroxyl groups in benzene ring of the two isomers. The results from electrochemical impedance spectroscopy also demonstrates that the over-oxidized PHQ electrode has a stronger affinity for HQ over CC.  相似文献   

13.
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at ?50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
Graphical abstract Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid is achieved on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups, through anodic treatment of glassy carbon and silane chemistry.
  相似文献   

14.
Glassy carbon electrode (GCE) is covalently modified with aspartic acid (Asp). The modified electrode is used for the simultaneous electrochemical determination of hydroquinone (HQ) and catechol (CC) and shows an excellent electrocatalytical effect on the oxidation of HQ and CC by cyclic voltammetry (CV) in 0.1 mol/L acetate buffer solution (pH 4.5). In differential pulse voltammetric (DPV) measurements, the modified electrode could separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 101 mV though the bare electrode gave a single broad response. A successful elimination of the fouling effect by the oxidized product of HQ on the response of CC has been achieved at the modified electrode. The determination limit of HQ in the presence of 0.1 mmol/L CC was 9.0 x 10(-7) mol/L and the determination limit of CC in the presence of 0.1 mmol/L HQ was 5.0 x 10(-7) mol/L. The proposed method has been applied to the simultaneous determination of HQ and CC in a water sample with simplicity and high selectivity.  相似文献   

15.
MWNTs-IL-Gel/GCE, a glassy carbon electrode modified with multiwalled carbon nanotubes (MWNTs) and ionic liquids (IL), was developed to serve as a sensor for simultaneous determination of Hydroquinone (HQ) and catechol (CC) in this paper. The modified GCE showed two well-defined redox waves for HQ and CC in both CV and DPV with a peak potential separation of ca. 0.1 V, which was large enough for simultaneous detection. The results revealed that the oxidation of HQ and CC with the enhancement of the redox peak current and the decrease of the peak-to-peak separation exhibit excellent electrocatalytic behaviors. A high sensitivity of 1.8×10(-7)M with detection limits of 6.7×10(-8)M and 6.0×10(-8)M (S/N=3) for HQ and CC were obtained. Moreover, the constants of apparent electron transfer rate of HQ and CC at MWNTs-IL-Gel/GCE were calculated as 7.402 s(-1) and 8.179 s(-1), respectively, and the adsorption quantity of HQ and CC was 1.408×10(-6) mol cm(-2) with chronocoulometry. The developed sensor can be applied to determinate directly of HQ and CC in aqueous solution.  相似文献   

16.
A three-dimensionally ordered macroporous (3DOM) polycysteine (PCE) film was electropolymerized on the glassy carbon electrode (GCE) using polystyrene spheres as template. The electrochemical behaviors of hydroquinone (HQ) and catechol (CC) were studied, and two independent oxidation peaks were observed. Compared with the bare GCE and GCE modified with PCE without using template, this electrode displays larger peak currents which may be attributed to the structure of PCE and the large surface area of the nanopore array structure. As a result, a novel electrochemical method was developed for the simultaneous determination of HQ and CC. Under the optimized conditions, the peak currents were linear to concentrations in the wider ranges of 9 to 700 μM for HQ and from 3 to 700 μM for CC. The method was successfully applied to the simultaneous determination of HQ and CC in spiked water samples, and the results are satisfactory.  相似文献   

17.
A glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNTs) and a hydrophobic ionic liquid (IL), was used for the simultaneous voltammetric determination of theophylline (TP) and guaifenesin (GF). The results showed that the oxidations of TP and GF were facilitated at modified electrode and peak‐to‐peak separation at MWCNT? IL/GCE (252 mV) was larger than that observed at unmodified GCE (165 mV). Voltammetric signals for TP and GF exhibited linear ranges of 0.5 to 98.0 µM (R2>0.99) and 1.5 to 480.0 µM (R2>0.99), respectively. The method was used to estimate TP and GF contents in some real samples.  相似文献   

18.
Herein, we report a simple method of simultaneous detection of hydroquinone (HQ) and catechol (CC) by cyclic voltammetry (CV) using activated glassy carbon electrodes (GCE). It was found that the two isomers can be completely separated by CV method on cathode polarized GCE (PGCE) after its anodic oxidation. This facile processing method solves the difficulty of electrode surface regenerating which disturb most modified electrodes for the complex composition ease of being contaminated by the analytes in measurement. Morphology and composition of the PGCE were characterized by scanning electron microscope (SEM), Fourier transform infrared (FTIR) spectra, and X-ray photoelectron spectroscopy. In addition, the reaction kinetic of HQ and CC reaction on the PGCE was investigated. It was found that the reaction kinetics of HQ and CC is a surface adsorption-controlled process at low concentration and a diffusion-controlled process at high concentration.  相似文献   

19.
A glassy carbon electrode (GCE) was modified with poly(L-arginine) (P-Arg), reduced graphene oxide (rGO) and gold nanoparticle (AuNP) to obtain an electrode for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp) in the presence of ascorbic acid (AA). The modified GCE was prepared via subsequent ‘layer-by-layer’ deposition using an electrochemical technique. The surface morphology of the modified electrode was studied by scanning electron microscopy, and electrochemical characterizations were carried out via cyclic voltammetry and electrochemical impedance spectroscopy. The modified electrode showed excellent electrocatalytic activity toward DA, 5-HT and L-Trp at pH 7.0. Figures of merit for the differential pulse voltammetric reponse are as follows: (a) Response to DA is linear in two intervals, viz. 1.0–50 nM and 1.0–50 μM DA concentration range, the typical working voltage is 202 mV (vs. Ag/AgCl), and the detection limit is 1 nM (at an S/N ratio of 3). For 5-HT, the respective data are 10 to 500 nM and 1.0 to 10 μM, 381 mV, and 30 nM. For L-Trp, the respective data are 10–70 nM and 10–100 μM, 719 mV, and 0.1 μM. The modified GCE is fairly selective. It was successfully applied to the simultaneous determination of DA, 5-HT, and L-Trp in spiked urine samples, and high recovery rates were found.
Graphical abstract Schematic presentation of the voltammetric sensor based on a glassy carbon electrode modified with poly(L-arginine), reduced graphene oxide (rGO) and gold nanoparticle (GCE/P-Arg/ErGO/AuNP) for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp).
  相似文献   

20.
Nitrogen-doped multiwalled carbon nanotubes modified with nickel nanoparticles (Ni/N-MWCNT) were prepared by a thermal reduction process starting from urea and Ni(II) salt in an inert atmosphere. The nanocomposite was deposited on a screen printed electrode and characterized by X-ray diffraction, scanning and transmission electron microscopy, nitrogen adsorption, X-ray photoelectron spectroscopy, and thermogravimetric analyses. The performance of the composite was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The numerous active metal sites with fast electron transfer properties result in enhanced electrocatalytic activity towards the individual and simultaneous detection of catechol (CC) and hydroquinone (HQ), best at 0.21 V for CC and 0.11 V for HQ (vs. Ag/AgCl). For both targets the detection limit (S/N of 3) was 9 nM (CC) and 11 nM (HQ), and the Ni/N-MWCNT-electrode showed linear response from 0.1–300 μM CC, and 0.3–300 μM HQ. The electrode is selective over many potentially interfering ions. It was applied to the analysis of spiked water samples and gave satisfactory recoveries. It also is sensitive for CC (5.396 μA·μM?1 cm?2) and HQ (5.1577 μA·μM?1 cm?2), highly active, durable, acceptably repeatable and highly reproducible.
Graphical abstract Voltammetric determination of catechol and hydroquinone using nitrogen-doped multiwalled carbon nanotubes modified with nickel nanoparticles.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号