首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
A method for the multimeric high-performance liquid chromatography of plant sterols is proposed which permits the separation of compounds close in structure with similar chromatographic properties. The first stage includes the chemical modification of the sterols with the aid of a bis(p-nitrophenyl) phosphate group. The phosphotriesters formed as the result of the reaction are separated by normal-phase HPLC. The compounds isolated are treated with ammonia, as a result of which the sterol phosphotriesters are converted into the corresponding phosphodiesters. These phosphodiesters are then subjected to reversed-phase HPLC. The chromatographic separation of UV-absorbing sterol derivatives using several variants of HPLC substantially increases the resolving power of the method.State Scientific-Research Institute on the Standardization and Control of Drugs, USSR Ministry of Health, Moscow. L. V. Lomonosov Moscow State University. Translated from Khimiya Prirodynkh Soedinenii, No. 6, pp. 831–836, November–December, 1988.  相似文献   

2.
A method for the multimeric high-performance liquid chromatography of plant sterols is proposed which permits the separation of compounds close in structure with similar chromatographic properties. The first stage includes the chemical modification of the sterols with the aid of a bis(p-nitrophenyl) phosphate group. The phosphotriesters formed as the result of the reaction are separated by normal-phase HPLC. The compounds isolated are treated with ammonia, as a result of which the sterol phosphotriesters are converted into the corresponding phosphodiesters. These phosphodiesters are then subjected to reversed-phase HPLC. The chromatographic separation of UV-absorbing sterol derivatives using several variants of HPLC substantially increases the resolving power of the method.  相似文献   

3.
A high-performance liquid chromatographic method for the determination of atazanavir (ATV) in human plasma is developed and validated. The method involves a rapid and simple solid-phase extraction (SPE) of ATV using Bond-elut C18 3 mL cartridge. The separation of ATV from internal standard and endogenous components is achieved using an isocratic elution on an octyl column and an UV detector set at 260 nm. The method is linear from 20 to 10,000 ng/mL (mean r2 = 0.9991, n = 10). The observed intra- and inter-day assay precision ranged from 2.2% to 14.7%[at the lower limit of quantitation (LOQ)], whereas accuracy varies between 1.0% and 14% (at LOQ). Mean drug recovery is 80.5% for ATV and 78.4% for IS. The method is found to be precise and accurate, practical enough for therapeutic drug monitoring in routine clinical practice and is applied for the assessment of 24-h ATV plasma concentration-time profiles in HIV-infected pregnant women.  相似文献   

4.
Solid-phase extraction (SPE) procedure for cleanup followed by HPLC-UV method has been investigated for the determination of pyraflufen-ethyl residues in soil. The pesticide is extracted from the sample with acetone-water (80:20, v/v) and the extract is loaded onto an octadecyl (C(18)) column. The pesticide is eluted with acetonitrile and determined by HPLC with a UV detector. Using an acetone-water extraction followed by a C(18) cleanup, this method is characterized by recovery >90.1%, precision <5.8% RSD and sensitivity of 0.01 mg/kg. The proposed method has been successfully employed for the determination of the degradation dynamics of pyraflufen-ethyl in four agricultural soil samples under laboratory conditions.  相似文献   

5.
Summary A new sensitive HPLC-UV method has been developed and validated for the determination of amboroxol in dog plasma enabling the investigation of a newly developed 75 mg ambroxol-containing retard capsule of EGIS Pharmaceuticals Ltd., Budapest, Hungary. A gradient method was used for removing the longer retained plasma components of no interest. The separation was performed on a BDS Hypersil C18 (5 μm, 250×2.1 mm) analytical column, supplied with a 10 mm guard column containing the same packing material. The detection was performed at 210 nm. The calibration curve was linear in the range 25–2000 ng·mL−1. Nerisopam (EGIS-6775) was used as internal standard. Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

6.
The determination of nicotinamide and pyridoxine in an elemental diet containing 46 compounds was performed by column-switching high-performance liquid chromatography with UV detection at 260 and 290 nm, respectively. The method is simple, rapid, sensitive and reproducible. The calibration graphs for the two vitamins were linear in the ranges 0-0.2 and 0-0.015 micrograms, respectively. The recoveries of both vitamins by the standard addition method were over 95%. There was good agreement between the concentrations indicated and found for both vitamins.  相似文献   

7.
An HPLC method with an evaporative light scattering detector was optimized and validated for quantification of carbohydrates in beer. The chromatographic separation was achieved using a Spherisorb NH2, 5 microm chromatographic column and gradient elution with acetonitrile/water. The determinations were performed in the linear range of 0.05-5.0 g/L for fructose, 0.05-5.0 g/L for glucose, 0.05-15.0 g/L for maltose, 0.05-10.0 g/L for maltotriose, and 0.05-5.0 g/L for maltotetraose. The detection limits were 0.005 g/L for fructose, 0.008 g/L for glucose, and 0.01 g/L for maltose, maltotriose, and maltotetraose. The reliability of the method in terms of precision and accuracy was evaluated in three beer matrices, low alcohol beer, 6% alcohol beer, and beer made with part of adjuncts (4.5% alcohol). Relative standard deviations (RSDs) ranged between 1.59 and 5.95% (n = 10), and recoveries ranged between 94 and 98.4%.  相似文献   

8.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

9.
Melamine in pet food (fortified or originally contaminated) was determined by enzyme immunoassay (EIA), high-performance liquid chromatography with diode array detection (HPLC-DAD), and ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS). The limits of detection (LOD) for EIA and HPLC-DAD were 0.02 and 0.1 microg/mL, respectively. The linear ranges of the calibration curves for EIA and HPLC-DAD were 0.02-0.5 and 0.1-500 microg/mL, respectively. The coefficient of determinations (r2) of the standard curves for EIA and HPLC were 0.9991 and 0.9999, respectively. Coefficient of variations from both inter- and intra-assay were <9.31%, and recovery range for all concentrations was between 71 and 105%. The r2 values between the EIA and HPLC-DAD methods for melamine analysis of the fortified and originally contaminated samples were 0.9973 and 0.9885. The r2 values for UPLC-MS/MS with HPLC-DAD and with EIA were 0.9566 and 0.9489, respectively.  相似文献   

10.
A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.  相似文献   

11.
A sensitive and selective method was developed for the first time to quantify simultaneously the normal and formaldehyde (FA)-modified bases in human placental DNA treated with 100 ppm FA for 20 h at 37 degrees Celsius. Digestion of DNA to deoxynucleosides with DNase I, phosphodiesterase and alkaline phosphatase occurred in that order with centrifugation steps. The normal and FA-modified deoxynucleosides were then resolved from one another and reagent blank interferences to produce selective separation through high performance liquid chromatography-ultraviolet detection at 254 nm. A C(18) reversed-phase column facilitated the resolution using 5 mm ammonium acetate and a gradient of 0-6% methanol at fl ow rates of 0.3-1.4 mL/min before column cleaning. The lower quantifiable limits for deoxyadenosine, deoxyguanosine, deoxycytidine, thymidine, N(6)-hydroxymethyldeoxyadenosine (N(6)-dA), N(2)-hydroxymethyldeoxyguanosine (N(2)-dG) and N(4)-hydroxymethyldeoxycytidine (N(4)-dC) were 11, 7.6, 12, 15, 10, 10 and 22 pmol, respectively. The abundance order of the modified deoxynucleosides was N(6)-dA > N(2)-dG > N(4)-dC. dT did not form hydroxymethyl derivatives. The respective concentrations were about 6.0, 10.0 and 23 pmol of modified deoxynucleosides in 80 micro g of human placental DNA after treatment with 100 micro g/mL of formalin for 20 h at 37 degrees Celsius. The stabilities of N(6)-dA and N(2)-dG were much better at -20 degrees Celsius than at 25 degrees Celsius, where the respective halftimes were about 50.1 and 21.0 h.  相似文献   

12.
Determination of 16 priority pesticides and transformation products specified in the EU Baby Food Directive 2003/13/EC has been compared using high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) coupled to tandem quadrupole mass spectrometry (MS/MS). Prior to analysis, co-extractives were removed from acetonitrile extracts using dispersive solid-phase extraction (SPE) with primary secondary amine (50 mg). Extracts spiked with pesticides at 1 microg kg(-1) yielded average recoveries in the range 85-119%, with relative standard deviations less than 17%. The HPLC-MS/MS and UPLC-MS/MS multi-residue methods developed are simple, rapid and suitable for the quantification and confirmation of the 16 priority pesticides in fruit-, potato- and cereal-based baby food at 1 microg kg(-1). The major advantages of UPLC, using 1.7 microm particles, over HPLC are the speed of analysis, the narrower peaks (giving increased signal-to-noise ratio) and improved confirmation for the targeted pesticides in the analyses of baby foods.  相似文献   

13.
A detailed comparison of the repeatability of the retention times, the peak efficiencies and the peak areas of a dozen probe compounds achieved in HPLC, using either HPLC-UV or HPLC-MS for detection purpose, is reported. Three groups of conventional analytes, each one separated under a different set of experimental conditions, were selected for this study. Most of the compounds are basic, the other ones being neutral. The repeatabilities of the retention times do not exhibit any influence of the mode of detection. However, the repeatabilities of the peak areas and the column efficiencies are generally (although not always) better in HPLC-UV than that in HPLC-MS. On average, the precision for the UV peak area detection was 2.5% versus 6.8% for MS detection. Experimental results show that the response factor of the UV detector is more constant than that of the MS detector, probably because the HPLC flow-rate was sufficiently stable. The results obtained in the different tests are discussed.  相似文献   

14.
The application of UV diode array detection in high-performance liquid chromatographic (HPLC) identification and quantitation of several classes of synthetic and commercially available alkylated nucleobases is investigated. Quantitative spectral overlays of these compounds to methyl standard references from a spectral library and absorbance ratios at two maximal wavelengths (lambda max) are found to be useful in categorizing the solutes. They can be grouped into classes of compounds originating from a specific nucleobase and classes of analogs having different alkyl substituents (e.g., methyl, ethyl, propyl, allyl, and benzyl) at the same position of the heterocycle. At a selected wavelength for alkylated nucleobases in the same class, the detector response factors are independent of the alkyl group (+/- 10%). This technique provides a practical means for both qualitative and quantitative analysis of product distribution of DNA base alkylation by using only readily obtainable methylated derivatives as the reference standards.  相似文献   

15.
Anthracyclines are very effective against soft tissue sarcomas, with cardiotoxicity being an important side effect after repeated administration. To estimate the relative cardiotoxicity of various anthracyclines and their metabolites, we developed an isolated mouse left atrium model. To relate an effect of doxorubicin, 4'-epidoxorubicin and their four main metabolites (doxorubicinol, epidoxorubicinol and the aglycons 7-deoxydoxorubicinon and 7-deoxydoxorubicinolon) to concentrations in the tissue instead of the incubation bath, a method of quantifying the anthracyclines in small tissue samples was developed. Atria were homogenized by sonication followed by extraction of the anthracyclines with methanol. The extract was directly analyzed by high-performance liquid chromatography with fluorescence detection. Recoveries for the six compounds tested ranged from 67.5% for 4'-epidoxorubicin to 100.6% for 7-deoxydoxorubinol aglycon with coefficients of variation of 2-3% at two spiked concentrations (0.1 and 1 nmol/mg of tissue). The calibration plots were linear (r2 greater than 0.996) over the concentration range tested (0.05-1 nmol/mg wet weight). The limits of detection (4-10 pmol/mg of tissue) were low enough to allow the determination of the anthracyclines at all relevant tissue concentrations.  相似文献   

16.
A rapid and sensitive assay was developed for the detection of the mycotoxin citrinin by reversed-phase chromatography. Citrinin was eluted from a radical-compression C18 column with a retention time of 3.86 min (flow-rate of 2.5 ml/min) with acetonitrile-water-acetic acid (40:59:1) containing tetrabutylammonium phosphate (0.0025 M) [corrected]. Comparative analysis revealed fluorescence detection to be 100 times more sensitive than detection by conventional ultraviolet absorbance. The fluorescence excitation and emission maxima of citrinin were 330 and 500 nm, respectively. The assay was linear over the concentration range between 0.01-100 micrograms/ml. Recovery experiments conducted by addition of citrinin to fermentation samples, revealed the assay quantitation efficiency to be 91-102%. Assay utility was demonstrated by using an Aspergillus niveus culture, propagated in complex liquid medium. Citrinin production was detected as early as 20 h following inoculation and increased dramatically when the culture entered the stationary phase of growth, analogous to other secondary metabolites. Unlike previously reported methods, this procedure has the advantage of enabling the direct quantitative analysis of citrinin in crude microbial fermentations without sample extraction.  相似文献   

17.
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 x 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from 1/2 the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 micrograms/kg for tilmicosin and tylosin, 30 micrograms/kg for spiramycin, and 25 micrograms/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.  相似文献   

18.
A multiresidue method based on matrix solid-phase dispersion (MSPD) microextraction was studied to determine the carbamate, benfuracarb, and urea insecticides, diflubenzuron, flufenoxuron hexaflumuron and hexythiazox, used in control of citrus pests. Optimisation of different parameters, such as the type of solid support for matrix dispersion, elution solvents and the clean-up step were carried out. The method used 0.5 g of orange sample, C8 bonded silica as MSPD sorbent and dichloromethane as eluting solvent. Recoveries, at spiked concentrations below the maximum residue levels established by Spanish Government, were between 74 and 84% with relative standard deviations ranging from 2 to 4%. The limits of quantification were from 0.15 to 0.25 microgram/g using high-performance liquid chromatography with UV detection at 200 nm. The method may be useful as a screening protocol for the determination of these newly developed pesticides in citrus samples.  相似文献   

19.
An automated analyzer for vancomycin in rat plasma by column-switching high-performance liquid chromatography (HPLC) with UV detection was developed. The method includes in-line extraction of vancomycin by ion-exchange cartridge column and a separation on a reversed-phase column with UV detection at 215 nm. Plasma samples were diluted by mobile phase solution and directly injected to HPLC. Vancomycin was quantitatively recovered from rat plasma samples. The separation was completed within 15 min. The calibration curve was linear over the range from 0.5 to 100 microg/mL with the detection and quantification limits of 0.5 microg/mL (2.5 ng on column; signal-to-noise ratio = 3). The values of precision in intra- and inter-day assays (n = 3) were less than 1.92 and 3.69%, respectively. This method does not require time-consuming pre-treatment and is suitable for the routine assay of plasma samples.  相似文献   

20.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号