A LC-MS/MS method with enhanced sensitivity and specificity was established for monitoring microcystin-LR (MC-LR) in drinking water supplies in southern Taiwan. The enhanced sensitivity was achieved by the selection of a doubly charged MC-LR as the precursor ion to result in an multiple reaction monitoring (MRM) pair ions of m/z 498.6 --> 135.0. Using this ion pair, a record low detection limit of 2 pg was achieved on column, found in the available literature. A sample preparation method involving C8 solid-phase extraction gave satisfactory recoveries of the analyte. Nodularin, with structural similarity to MC-LR, was used as an internal standard to minimize matrix effects of water samples collected from six different water reservoirs in southern Taiwan, where MC-LR was detected at sub-ppb levels in all the reservoirs. The best precision and accuracy of this method were found with samples prepared to contain MC-LR at 0.1 and 1 microg l(-1). This new method requires considerably smaller water sample volumes because of enhanced quantification sensitivity and hence reduces the time needed for analysis. It should serve as a useful example for method development for monitoring other members of the microcystin family in drinking water supplies. 相似文献
Aromatase (CYP 19A1) is a key steroidogenic enzyme that catalyzes the conversion of androgen to estrogen. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for aromatase inhibitor screening was developed and validated. The substrate androstenedione was incubated with human CYP 19A1 supersomes in the presence of NADPH for 30 min, and estrone formation was determined by LC-MS/MS analysis. Cortisone was used as internal standard. The incubation mixture was extracted using a liquid-liquid extraction method with ethyl acetate. Chromatographic separation was achieved using a C18 column (3.0?×?50 mm, 2.7 μm) with a mobile phase consisting of 0.1 % formic acid/acetonitrile adopting gradient elution at a flow rate of 0.4 mL/min. The mass spectrometer was operated in positive electrospray ionization mode. The precursor-product ion pairs used for multiple reaction monitoring were m/z 287→97 (androstenedione), m/z 271?→?159 (estrone), and m/z 361?→?163 (IS, cortisone). The developed method met the required criteria for the validation of bioanalytical methods. The validated method was successfully applied to evaluate aromatase inhibitory activity of plants extracts of Simaroubaceae.
Figure
Determination of estrone formation by LC-MS/MS analysis for aromatase inhibitor screening 相似文献
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for the quantitative determination of cynandione A in rat plasma and tissues. The plasma samples were pretreated by liquid-liquid extraction with ethyl acetate after the internal standard (honokiol) had been spiked. The tissue samples were homogenized with physiological saline and treated further like the plasma samples. The separation was performed using a Zorbax SB-C(18) column (3.5 microm, 2.1 x 100 mm) and a C18 guard column (5 microm, 4.0 x 2.0 mm) with an isocratic mobile phase consisting of methanol-0.1% formic acid (78:22, v/v) at a flow rate of 0.2 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple-reaction monitoring mode using the electrospray ionization technique in negative mode. The nominal retention times for cynandione A and honokiol were 1.41 and 2.63 min, respectively. The method was validated within the concentration range 0.2-1000 ng/mL in plasma and homogenized tissue for cynandione A, and the calibration curves were linear with correlation coefficients >0.992. The lower limit of quantification of cynandione A was 0.2 ng/mL. The intra-day and inter-day precision and accuracy of the assay in plasma were less than 14.4%, while the intra-day and inter-day precision and accuracy of the assay in tissue homogenate were less than 14.2%. This method proved to be suitable for study of pharmacokinetics and tissue distribution of cynandione A in rat. 相似文献
Photodegradation of quetiapine under UVC irradiation in methanol solution was investigated and structural elucidation of its photodegradation products was performed with the use of the reversed phase UHPLC system coupled with accurate mass hybrid ESI-Q-TOF mass spectrometer. During one run all essential data for the determination of photodegradation kinetics and for the structural elucidation of the products was collected with the use of auto MS/MS mode. Five degradation products were found and their masses and formulas were obtained with high accuracy (0.26–5.02 ppm). For all the analyzed compounds, MS/MS fragmentation spectra were also obtained allowing structural elucidation of the unknown degradation products and indicating photodegradation pathways of quetiapine. The main photodegradation product was identified as 2-[2-[4-(5-oxidodibenzo[b,f][1,4]thiazepin-11-yl)-1-piperazinyl]ethoxy]-ethanol and the photodegradation reaction yields the first-order kinetics with the rate constant k = 0.1094 h−1. 相似文献
Ethyl glucuronide (EtG) is a metabolite and a specific marker of alcohol consumption that can be detected days after the complete elimination of alcohol after drinking. A rapid, simple, and sensitive LC-ESI-MS/MS method for the determination of urinary ethyl glucuronide was developed and fully validated in accordance with analytical standards, using the C18 column. The whole process including sample preparation and LC-MS/MS lasted 10 min. A comprehensive validation including HorRat, measurement uncertainty, system suitability and intermediate precision calculations among analysts, and a cut-off limit study was performed. The method was applied to real samples and a cutoff limit determination study. The LOD and LOQ (using the IUPAC and Eurachem methods) were determined as 104.21 ng mL?1 and 165.00 ng mL?1. A cut-off limit of ≈ 818 ng mg?1 (normalised to creatinine) was found for urinary EtG. The results showed that the cut-off limits currently in use should be re-considered in further studies and standardised on a global scale. Normalisation to creatinine is important because of the risk of the dilution of urine intentionally or with a change of diet. The concentrations of real samples from subjects who had consumed alcohol were successfully predicted using this method, after zero HS-GC/MS results of urine alcohol concentration. 相似文献
Pharmacy staff and health care workers in hospitals may be exposed to antineoplastic drugs during cancer chemotherapy. Sensitive methods should be used to monitor the occupational exposure in biofluids such as urine. In this study, a sensitive method for cyclophosphamide determination in urine with high recovery was developed and validated for monitoring occupational exposure. Triple liquid-liquid extraction with ethyl acetate/dichloromethane (φr= 3:1; 6.0 mL) was applied. Good separation of cyclophosphamide and ifosfamide was achieved in a 9.0 min analysis, using liquid chromatography combined with tandem mass spectrometry (LC-MS/MS). Limit of detection and limit of quantification were 0.07 ng mL?1 and 0.11 ng mL?1, respectively. Repeatability (RSD, %) was ≤ 12.74%. Inter-day and inter-analyst precision values (RSD, %) were ≤ 13.94% and 12.59%. Mean recovery for three different concentrations was (101.62 ± 6.05) %. The validation results were fitted for the purpose of routine monitoring of occupational cyclophosphamide exposure in hospital staff. 相似文献
Since the late 1990s and early 2000s, derivatives of well-known designer drugs as well as new psychoactive compounds have
been sold on the illicit drug market and have led to intoxications and fatalities. The LC-MS/MS screening method presented
covers 31 new designer drugs as well as cathinone, methcathinone, phencyclidine, and ketamine which were included to complete
the screening spectrum. All but the last two are modified molecular structures of amphetamine, tryptamine, or piperazine.
Among the amphetamine derivatives are cathinone, methcathinone, 3,4-DMA, 2,5-DMA, DOB, DOET, DOM, ethylamphetamine, MDDMA,
4-MTA, PMA, PMMA, 3,4,5-TMA, TMA-6 and members of the 2C group: 2C-B, 2C-D, 2C-H, 2C-I, 2C-P, 2C-T-2, 2C-T-4, and 2C-T-7.
AMT, DPT, DiPT, MiPT, DMT, and 5MeO-DMT are contained in the tryptamine group, BZP, MDBP, TFMPP, mCPP, and MeOPP in the piperazine
group. Using an Applied Biosystems LC-MS/MS API 365 TurboIonSpray it is possible to identify all 35 substances. After addition
of internal standards and mixed-mode solid-phase extraction the analytes are separated using a Synergi Polar RP column and
gradient elution with 1 mM ammonium formate and methanol/0.1% formic acid as mobile phases A and B. Data acquisition is performed
in MRM mode with positive electro spray ionization. The assay is selective for all tested substances. Limits of detection
were determined by analyzing S/N-ratios and are between 1.0 and 5.0 ng/mL. Matrix effects lie between 65% and 118%, extraction efficiencies range from 72%
to 90%. 相似文献
We report here a novel approach for the extraction and analysis of thyroid hormones (TH) and their metabolites (THM) from human serum samples. Our method features a compact, 96-well micro-titre plate-based pre-analytic extraction/clean-up workflow combined with an isotope dilution LC-MS/MS-MS3 analytical method. In particular, these features make possible the detection of iodothyronines at their endogenous concentrations in serum differing by a factor of ca. 104, with potential to semi-automate the pre-analytics. The method was validated by the assessment of linearity, lower limits of quantification and detection (LLOQ and LLOD respectively), intra- and inter-day accuracy, precision, process efficiency (PE), matrix effect (ME) and relative recovery (RE). Calibration curves were linear in the concentration range in sample matrix from 0.1–250 nM for T3, rT3, T4 and 3-T1AM and from 0.005–1 nM for 3,5-T2 and 3,3′-T2. Using a 200-μL sample volume, the analyte dependant LLOQ were in the range 0.005 (3,5-T2) to 0.25 (T4) nM and LLOD were between 0.002 (3,5-T2) and 0.052 nM (T4). We applied the LC-MS/MS-MS3 method to the analysis of a cross section of patients with disorders of the thyroid hormone axis. T4, T3 and rT3 concentrations (± standard deviation) were 120 ± 18, 1.9 ± 0.4 and 0.45 ± 0.09 nM respectively. 3,3′-T2 concentrations (± standard deviation) were 0.079 ± 0.022 nM; 3,5-T2 concentrations were below the LLOQ and/or LLOD in all but a single sample (0.013 nM). This method expands the analytical spectrum to endogenous thyroid hormone metabolites such as 3,5-T2 which exert biological actions and rT3 which may act as surrogate markers for disturbed thyroid hormone metabolism.
An improved method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of glycidyl fatty acid esters in oils was developed. The method incorporates stable isotope dilution analysis (SIDA) for quantifying the five target analytes: glycidyl esters of palmitic (C16:0), stearic (C18:0), oleic (C18:1), linoleic (C18:2) and linolenic acid (C18:3). For the analysis, 10 mg sample of edible oil or fat is dissolved in acetone, spiked with deuterium labelled analogs of glycidyl esters and purified by a two-step chromatography on C18 and normal silica solid phase extraction (SPE) cartridges using methanol and 5% ethyl acetate in hexane, respectively. If the concentration of analytes is expected to be below 0.5 mg/kg, 0.5 g sample of oil is pre-concentrated first using a silica column. The dried final extract is re-dissolved in 250 μL of a mixture of methanol/isopropanol (1:1, v/v), 15 μL is injected on the analytical C18 LC column and analytes are eluted with 100% methanol. Detection of target glycidyl fatty acid esters is accomplished by LC-MS/MS using positive ion atmospheric pressure chemical ionization operating in Multiple Reaction Monitoring mode monitoring 2 ion transitions for each analyte. The method was tested on replicates of a virgin olive oil which was free of glycidyl esters. The method detection limit was calculated to be in the range of 70-150 μg/kg for each analyte using 10 mg sample and 1-3 μg/kg using 0.5 g sample of oil. Average recoveries of 5 glycidyl esters spiked at 10, 1 and 0.1 mg/kg were in the range 84% to 108%. The major advantage of our method is use of SIDA for all analytes using commercially available internal standards and detection limits that are lower by a factor of 5-10 from published methods when 0.5 g sample of oil is used. Additionally, MS/MS mass chromatograms offer greater specificity than liquid chromatography-mass spectrometry operated in selected ion monitoring mode. The method will be applied to the survey of glycidyl fatty acid esters in food products on the Canadian market. 相似文献
Pomalidomide is an immunomodulatory agent (IMiD) that has been approved by the US Food and Drug Administration (FDA) for clinical treatment of patients with multiple myeloma.In this work,we developed a sensitive and validated LC-MS/MS method for high-throughput determination of pomalidomide over the range of 1.006–100.6 ng/m L (R2=0.9991) in human plasma and pharmacokinetic studies.A liquid-liquid extraction method using ethyl acetate was applied to extract pomalidomide and afatinib (... 相似文献
Small specimen volume and high sample throughput are key features needed for routine methods used for population biomonitoring. We modified our routine eight-probe solid phase extraction (SPE) LC-MS/MS method for the measurement of five folate vitamers [5-methyltetrahydrofolate (5-methylTHF), folic acid (FA), plus three minor forms: THF, 5-formylTHF, 5,10-methenylTHF] and one oxidation product of 5-methylTHF (MeFox) to require less serum volume (150 μL instead of 275 μL) by using 96-well SPE plates with 50 mg instead of 100 mg phenyl sorbent and to provide faster throughput by using a 96-probe SPE system. Total imprecision (10 days, two replicates/day) for three serum quality control pools was 2.8–3.6 % for 5-methylTHF (19.5–51.1 nmol/L), 6.6–8.7 % for FA (0.72–11.4 nmol/L), and ≤11.4 % for the minor folate forms (<1–5 nmol/L). The mean (±SE) recoveries of folates spiked into serum (3 days, four levels, two replicates/level) were: 5-methylTHF, 99.4?±?3.6 %; FA, 100?±?1.8 %; minor folates, 91.7–108 %. SPE extraction efficiencies were ≥85 %, except for THF (78 %). Limits of detection were ≤0.3 nmol/L. The new method correlated well with our routine method [n?=?150, r?=?0.99 for 5-methylTHF, FA, and total folate (tFOL, sum of folate forms)] and produced slightly higher tFOL (5.6 %) and 5-methylTHF (7.3 %) concentrations, likely due to the faster 96-probe SPE process (1 vs. 5 h), resulting in improved SPE efficiency and recovery compared to the eight-probe SPE method. With this improved LC-MS/MS method, 96 samples can be processed in ~2 h, and all relevant folate forms can be accurately measured using a small serum volume.
Figure
High-throughput LC-MS/MS method for population monitoring of serum folate forms 相似文献
A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method, characterized by complete automation and high-throughput, was developed for the determination of colistin A and B in human plasma. All sample preparation procedures were performed by using 2.2 mL 96-deep-well plates, whereas robotic liquid-handling workstations were utilized for all liquid transfer steps, including solid-phase extraction (SPE). The whole preparation procedure was very rapid, whereas the method had a very short chromatographic run time of just 2 min. Sample analysis was performed by reversed phase LC-MS/MS, with positive electrospray ionization, using multiple reaction monitoring. The absence of available purified colistin A and B standards led to the development of a novel LC method with evaporative light-scattering detector for the determination of their stoichiometries in the standard mixture, along with its purity. The proposed bioanalytical method was fully validated and it was proven to be selective, accurate, precise, reproducible and suitable for the determination of colistin A and B in human plasma. It was applied successfully to a pharmacokinetic study for the determination of both analytes in samples of patients. 相似文献
A new method is described for performing hydrogen/deuterium (H/D) exchange in an electrospray ionization (ESI) source. The use of liquid chromatography (LC)-mass spectrometer equipped with an ESI source and deuterium oxide (D2O) as the sheath liquid allows H/D exchange experiments to be performed on-line. This directly provides information for determining the number and position of exchangeable hydrogens, aiding in the elucidation of the structures of drug metabolites. To demonstrate the utility of this method, LC-mass spectrometry (MS) and LC-MS/MS experiments were performed using either H2O or D2O as sheath liquid on a matrix metalloprotease (MMP) inhibitor (PD 0200126) and its metabolites. Examination of the mass shift of the deuteriated molecule from that of the protonated molecule allowed the number of exchangeable protons to be determined. Interpretation of the production-spectra helped to determine the location of the exchanged protons and assisted in the assignment of the site(s) of modification for each metabolite. 相似文献