首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
The diastereoisomeric separation of peptidomimetics of hexarelin, a strong growth hormone secretagogue, in CE has been studied. Highly sulfated‐γ‐CD was found to be an appropriate selector for the separation of the stereoisomers. However, non‐repeatable analyses were obtained on bare fused silica capillary due to the progressive adsorption of the analytes on the capillary wall. Two types of polyelectrolyte coating agents were tested to prevent this phenomenon. Coating with neutral polyethylene oxide was found to be efficient but resulted in a very long analysis time (about 40 min). Coating with cationic poly(diallyldimethylammonium) chloride was found both to prevent analyte adsorption, reduce analysis time and alter separation selectivity. EOF measurement revealed that the highly sulfated‐γ‐CDs were strongly adsorbed on the poly(diallyldimethylammonium) chloride coating surface yielding a stable strong cathodic EOF, which considerably reduced analysis time (about 12 min). Very good repeatability of analysis was obtained (RSDmigration time<1%).  相似文献   

2.
Dynamic computer simulation data are compared for the first time with CE data obtained with a laboratory made system comprising an array of 8 contactless conductivity detectors (C4Ds). The experimental setup featured a 50 μm id linear polyacrylamide (LPA) coated fused‐silica capillary of 70 cm length and a purpose built sequential injection analysis manifold for fluid handling of continuous or discontinuous buffer configurations and sample injection. The LPA coated capillary exhibits a low EOF and the manifold allows the placement of the first detector at about 2.7 cm from the sample inlet. Agreement of simulated electropherograms with experimental data was obtained for the migration and separation of cationic and anionic analyte and system zones in CZE configurations in which EOF and other column properties are constant. For configurations with discontinuous buffer systems, including ITP, experimental data obtained with the array detector revealed that the EOF is not constant. Comparison of simulation and experimental data of ITP systems provided the insight that the EOF can be estimated with an ionic strength dependent model similar to that previously used to describe EOF in fused‐silica capillaries dynamically double coated with Polybrene and poly(vinylsulfonate). For the LPA coated capillaries, the electroosmotic mobility was determined to be 17‐fold smaller compared to the case with the charged double coating. Simulation and array detection provide means for quickly investigating electrophoretic transport and separation properties. Without realistic input parameters, modeling alone is not providing data that match CE results.  相似文献   

3.
CE of biomolecules is limited by analyte adsorption on the capillary wall. To prevent this, monolayer or successive multiple ionic‐polymer layers (SMILs) of highly charged polyelectrolytes can be physically adsorbed on the inner capillary surface. Although these coatings have become commonly used in CE, no systematic investigation of their performance under different coating conditions has been carried out so far. In a previous study (Nehmé, R., Perrin, C., Cottet, H., Blanchin, M. D., Fabre, H., Electrophoresis 2008, 29, 3013–3023), we investigated the influence of different experimental parameters on coating stability, repeatability and peptide peak efficiency. Optimal coating conditions for monolayer and multilayer (SMILs) poly(diallyldimethylammonium) chloride/ poly(sodium 4‐styrenesulfonate) coated capillaries were determined. In this study, the influence of polyelectrolyte concentration and ionic strength of the coating solutions, and the number of coating layers on coating stability and performance in limiting protein adsorption was carried out. EOF magnitude and repeatability were used to monitor coating stability. Coating ability to limit protein adsorption was investigated by monitoring variations of migration times, time‐corrected peak areas and separation efficiency of test proteins. The separation performance of polyelectrolyte coatings were compared with those obtained with bare silica capillaries.  相似文献   

4.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

5.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

6.
Capillary electrophoretic separations of inorganic anions are performed using a capillary coated with a mixture of the cationic surfactant didodecyldimethylammonium bromide (DDAB) and the zwitterionic surfactant 1,2-dilauroyl-sn-phosphatidylcholine (DLPC). These double-chained surfactants form semi-permanent coatings on the capillary wall, which allows the excess surfactant to be removed from the buffer prior to separation. Interactions between surfactant aggregates in the buffer and analyte anions are thus eliminated. The electroosmotic flow (EOF) can be altered from fully reversed (100% DDAB) to near zero (100% DLPC) using different ratios of DDAB and DLPC. Controlling the EOF allows for improved resolution of the anions while maintaining a rapid, co-EOF separation, free from analyte-surfactant additive interactions.  相似文献   

7.
In this work, a new copolymer synthesized in our laboratory is used as physically adsorbed coating for capillary electrophoresis (CE). The copolymer is composed of ethylpyrrolidine methacrylate (EPyM) and methylmethacrylate (MMA). The capillary coating is easily obtained by simply flushing into the tubing an EPyM/MMA solution. It is demonstrated that the composition of the EPyM/MMA copolymer together with the selection of the background electrolyte (BGE) and pH allow tailoring the direction and magnitude of the electroosmotic flow (EOF) in CE. It is also shown that the EOF obtained for the EPyM/MMA-coated capillaries was reproducible in all cases independently on pH or polymer composition. Thus, RSD values lower than 1.9% (n=5) for the same capillary and day were obtained for the migration time, while the repeatability interdays (n=5) was observed to provide RSD values lower than 0.5%. The stability of the coating procedure was also tested between capillaries (n=3) obtaining RSD values lower than 0.6%. It is demonstrated with several examples that the use of EPyM/MMA coatings in CE can drastically reduce the analysis time and/or to improve the resolution of the separations. It is shown that EPyM/MMA-coated capillaries allow the separation of basic proteins by reducing their adsorption onto the capillary wall. Also, EPyM/MMA-coated capillaries provide a faster separation of samples containing simultaneously positive and negative analytes. Moreover, it is demonstrated that the use of EPyM/MMA-coated capillaries can incorporate an additional chromatographic-like interaction with nucleosides that highly improves the separation of this group of solutes.  相似文献   

8.
Polyelectrolytes are widely used in capillary electrophoresis as coating agents of silica capillaries to prevent adsorption phenomena and improve the repeatability of peptide and protein analysis. A systematic study of the coating experimental conditions has been carried out to optimize coating stability and performance. The main experimental parameters studied were the type and concentration of polyelectrolytes used in several monolayer and multilayer coatings, the ionic strength of coating and stabilizing solutions, and the procedures used for coating and capillary storage. Electroosmotic flow magnitude, direction and repeatability were used to monitor coating stability. Coating ability to limit adsorption was investigated by monitoring variations of migration times, time-corrected peak areas and separation efficiency of test peptides. Capillary-to-capillary and batch-to-batch reproducibility was also studied. In addition, the separation performance of polyelectrolyte coatings were compared to those obtained with bare silica capillaries.  相似文献   

9.
Control of the electroosmotic flow (EOF) is critical for achieving optimal separations by capillary electrophoresis. For instance, manipulation of the EOF can yield either high resolution separations or rapid analyses. Dynamic capillary coatings are a simple and cost-effective approach to altering the EOF. The normal EOF can be slowed using buffer additives such as Mg2+ and hexamethonium which ion exchange onto the surface silanols to lower the effective wall charge. Alternatively, cationic polyelectrolytes or cationic surfactants can be used to establish a cationic coating on the capillary wall, which results in a reversed EOF. Practical considerations such as pH stability and reproducibility obtainable with an EOF modifier will be discussed.  相似文献   

10.
The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).  相似文献   

11.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

12.
The necessity for microchannel wall coatings in capillary and chip-based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused-silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes--covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.  相似文献   

13.
Semipermanent surfactant coatings are effective for the prevention of wall adsorption of proteins in CE. However, they often suffer from their unsatisfactory coating stability as they essentially degrade from the capillary walls after the surfactants are removed from the buffer. In this paper, we proposed a facile and universal method to improve the stability of semipermanent surfactant coatings based on addition of an oppositely charged surfactant into the coating. Didodecyldimethylammonium bromide (DDAB) and a gemini surfactant, 18-6-18, were used as the model semipermanent coatings, and sodium dodecyl sulfate (SDS) was chosen as their oppositely charged surfactant. SDS can strongly alter the packing parameter P of the cationic surfactants, and consequently mediates the coating stability. With the increase of SDS concentration in coating, the coating stability first dramatically increases due to the enlarged P, and then decreases due to the weakness of electrostatic interaction between the capillary wall and surfactant coating. At the proper SDS concentration, very stable coatings can be obtained that, even after rinsing under 138 kPa for 60 min, the reversed electroosmotic flow (EOF) only decreases by 3.6%. These SDS-enhanced coatings show excellent stability and reproducibility in protein separation (RSD of migration time <1.1% for run-to-run assay, n=9). Also, the high separation efficiency (>500,000 plates/m) and fine recovery of tested proteins indicate that these coatings are powerful in wall adsorption suppression. Finally, we found that the separation efficiency of protein was a more exact indicator for the coating stability than the traditional EOF magnitude.  相似文献   

14.
Liu Q  Yuan J  Li Y  Yao S 《Electrophoresis》2008,29(4):871-879
In this paper, we presented the first example of using gemini surfactants as semipermanent coatings in CE for protein separation. These coatings are based on the self-assembly of a series of cationic gemini surfactants, alkanediyl-alpha,omega-bis(dimethylalkylammonium bromide) (m-s-m), on the capillary wall. The coatings can keep stable for a long time without surfactant in the buffer, e.g., after the surfactants were removed from the buffer, the reversed EOF only decreased by 3.6 and 3.9% for 18-2-18 and 16-2-16 coatings over 60 min under continuous electrophoretic conditions. The coating stability increased with the alkyl chain length m. The double long chains of geminis (m > or = 14) yielded a good coating stability; meanwhile, the spacer group acted as an EOF modifier. Thus, this bifunctional surfactant coating provided a new buffer-independent method for EOF control. For 18-s-18 series, the best coating stability and largest EOF were obtained at s = 10. Ranging s from 3 to 10 yielded a linear fine-tuning of EOF and thereby allowed the adjustment of the protein apparent mobility. Highly efficient separation (>500 000 plates/m) was achieved with all the 18-s-18 coatings. Excellent run-to-run and day-to-day reproducibility (RSD of migration time 相似文献   

15.
Yang R  Shi R  Peng S  Zhou D  Liu H  Wang Y 《Electrophoresis》2008,29(7):1460-1466
We present cationized hydroxyethylcellulose (cat-HEC) synthesized in our laboratory as a novel physically adsorbed coating for CE. This capillary coating is simple and easy to obtain as it only requires flushing the capillary with polymer aqueous solution. A comparative study with and without polymers was performed. The adsorbed cat-HEC coating exhibited minimal interactions with basic proteins, providing efficient basic protein separations with excellent reproducibility. Under broad pHs, the amine groups are the main charged groups bringing about a global positive charge on the capillary wall. As a consequence, the cat-HEC coating produced an anodal EOF performance. A comparative study on the use of hydroxyethylcellulose (HEC) and cat-HEC as physically adsorbed coatings for CE are also presented. The separation efficiency and analysis reproducibility proved that the cat-HEC polymer was efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. The long-term stability of the cat-HEC coating in consecutive protein separation runs has demonstrated the suitability of the coating for high-throughput electrophoretic protein separations.  相似文献   

16.
A surfactant bilayer/diblock polymer coating was previously developed for the separation of proteins. The coating consisted of a mixture of the cationic surfactant dioctadecyldimethylammonium bromide (DODAB) and the neutral polymer poly-oxyethylene (POE) 40 stearate (Journal of Chromatography A 1130 (2006) 265–271). Herein an improved method of generating DODAB/POE stearate coatings is demonstrated, which yields more predictable EOF, more stable coatings, greater average efficiencies and easier method development. In this sequential preparation method the DODAB is first flowed through the capillary, followed by a flow of the POE stearate (sequential method). A tunable EOF (−2.40 to −0.17 × 10−4 cm2/Vs) is achieved by varying the POE chain length (8, 40 and 100 oxyethylene units). Mixtures of POE 8 and POE 40 stearate enabled continuous variation in EOF from −2.44 to −0.42 × 10−4 cm2/Vs. Separations of basic proteins yielded efficiencies of 760 000–940 000 plates/m. Coatings formed using the sequential method were more stable over a larger number of runs (%RSD for migration times: 0.7–1.0% over 30 runs) than those formed using the original mixed method (%RSD: 2.4–4.6% over 14 runs). The ability to tune the EOF is important in maximizing the resolution of analytes with similar electrophoretic mobilities. Histone proteins are separated on a sequentially coated capillary with resolution of nine possible subtypes. Acidic proteins are separated on a sequentially coated capillary at pH 6.4.  相似文献   

17.
A physically adsorbed and covalently bonded porphyrin derivative, 5,10,15,20-tetrakis(pentafluorophenyl)porphyrin, H2TPFPP, has been used as a fused-silica capillary wall modifier in open tubular capillary electrochromatography (OT-CEC), and its influence on the electroosmotic flow (EOF) velocity and on the selectivity of OT-CEC separations of a set of model aromatic carboxylic acids has been tested. Whereas most of the coatings of this category bring about an increase in selectivity with a concomitant slow down of the EOF, H2TPFPP coating, depending on pH of the background electrolyte used, resulted both in decreasing of EOF at pH 8.5 by 5% and in increasing of EOF by 10–43% at pH 6 and 5, respectively. The separation efficiency and the resolution of aromatic carboxylic acids separation in coated capillaries, namely in that one with covalent coating, were better than in the bare fused-silica capillary. The perspectives of H2TPFPP as capillary wall modifier are visualized in introducing well defined electroosmotic properties of materials used for miniaturized separation channels preparation in chip-based electromigration devices.  相似文献   

18.
Yao L  Liu Q  Li Y  Yao S 《Journal of separation science》2011,34(18):2441-2447
Separation of inorganic anions by capillary electrophoresis (CE) is usually conducted in co-electroosmotic mode due to the large electrophoretic mobilities of inorganic anions. Semipermanent surfactant coatings have been shown to be effective for CE of inorganic anions due to their strong capability of electroosmotic flow (EOF) manipulation. However, semipermanent coatings often suffer from their unsatisfactory stability. In addition, organic solvent additives are usually required to adjust the selectivity, which also aggravate the degradation of coating. In this work, a novel semipermanent coating consisting of cationic Gemini surfactant 18-10-18 and nonionic surfactant Tween 20 was developed to separate inorganic anions in CE. This coating is easy to prepare and more stable than pure Gemini coating. The introduction of nonionic surfactant in the coating not only suppresses the reversed EOF but can also adjust the selectivity of separation. Good separations of six model anions were achieved, the separation efficiency was as high as 65040-169700 plates/m and the RSDs of the migration times were less than 0.5 and 2.5% for run-to-run and day-to-day assays, respectively. Calibration curves were linear in the range of 0.05-5.0 mM; the detection limits ranged from 20 to 50 μM. More importantly, no organic solvents are required in the background buffer to achieve the satisfactory separations. This guarantees the coating stability and makes the method greener than most of other methods for CE of inorganic anions.  相似文献   

19.
CZE has become widespread for the separation and analysis of biomolecules such as proteins and peptides, due to factors such as, the speed of the separations, low sample volume, and high resolution associated with the technique. However, the separation of biomolecules by CZE does present a significant challenge due to the electrostatic attraction and adsorption of cationic, or cation containing, biomolecules to the capillary surface. To that end numerous methods have been developed to passivate, or protect the surface, in order to prevent the adsorption of analytes. Yet, in the process of protecting the capillary surface, the potential for further modification of the EOF, a factor crucial to effective analyte resolution, is greatly diminished. In seeking to overcome this limitation we have explored the potential of incorporating a range of metal cations into a phospholipid bilayer capillary coating. It has previously been established that the inclusion of calcium into the separation buffer with a phospholipid coating will reverse the EOF in the capillary. Here, we present our investigation of a broader range of metal cations included in the separation buffer (Ca2+, Mg2+, Co2+, Ni2+, Sr2+, Ba2+, and Ce3+) revealing that the choice of metal cation can drastically influence the EOF, with observed values between ?3.80 × 10?4 and ?5.74 × 10?5 cm2/V·s.  相似文献   

20.
Analyte–wall interaction is a significant problem in capillary electrophoresis (CE) as it may compromise separation efficiencies and migration time repeatability. In CE, self-assembled polyelectrolyte multilayer films of Polybrene (PB) and dextran sulfate (DS) or poly(vinylsulfonic acid) (PVS) have been used to coat the capillary inner wall and thereby prevent analyte adsorption. In this study, atomic force microscopy (AFM) was employed to investigate the layer thickness and surface morphology of monolayer (PB), bilayer, (PB-DS and PB-PVS), and trilayer (PB-DS-PB and PB-PVS-PB) coatings on glass surfaces. AFM nanoshaving experiments providing height distributions demonstrated that the coating procedures led to average layer thicknesses between 1 nm (PB) and 5 nm (PB-DS-PB), suggesting the individual polyelectrolytes adhere flat on the silica surface. Investigation of the surface morphology of the different coatings by AFM revealed that the PB coating does not completely cover the silica surface, whereas full coverage was observed for the trilayer coatings. The DS-containing coatings appeared on average 1 nm thicker than the corresponding PVS-containing coatings, which could be attributed to the molecular structure of the anionic polymers applied. Upon exposure to the basic protein cytochrome c, AFM measurements showed an increase of the layer thickness for bare (3.1 nm) and PB-DS-coated (4.6 nm) silica, indicating substantial protein adsorption. In contrast, a very small or no increase of the layer thickness was observed for the PB and PB-DS-PB coatings, demonstrating their effectiveness against protein adsorption. The AFM results are consistent with earlier obtained CE data obtained for proteins using the same polyelectrolyte coatings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号