首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Determination of barium in water and biological fluids by emission spectrometry with an inductively-coupled plasma

An emission spectrometric method is described for the determination of barium in water urine and blood with an inductively-coupled plasma. The method is highly selective, reproducible, and sensitive. The limits of detection are 0.06 μg l-1 in water, 0.25 μg l-1 in urine, 0.6 μg l-1 in blood. For thirteen healthy subjects, the barium content was 4.3 μg l-1 (s = 1.4) in urine and less than 1 μg l-1 in blood. For a case of accidental poisoning, the content was 260 μg Ba l-1 in blood and 280 μg Ba l-1 in urine.  相似文献   


2.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems.  相似文献   

3.
Different methods of atomization of selenium from a platinum wire filament are described, including electrothermal heating of the filament and atomlzation in an argon-hydrogen flame. A combination of these approaches proved to give the best sensitivity and detection limit. The selenium was preconcentrated on the filament by electrolysis prior to the atomic absorption measurements to eliminate chemical interferences and improve the sensitivity of the method. The detection limit was 0.5 μg l-1 for a 5-min electrolysis, and 0.2 μg l-1 when the electrolysis time was 30 min.  相似文献   

4.
《Analytica chimica acta》2004,520(1-2):117-124
Changes in fresh weight, total protein amounts (Bradford’s method), cadmium concentration (DPASV) and glutathione content (HPLC/MS) were studied in maize kernels cultivated for 5 days at three different cadmium concentrations (0, 10 and 100 μmol l−1 CdCl2). A highly sensitive HPLC/MS method was used for the determination of glutathione on a reversed-phase Atlantis dC18 chromatographic column (150 mm×2.1 mm, 3 μm particle size). An isocratic mode with acetonitrile–0.01% TFA (5:95, flow rate 0.1 ml min−1 and 30 °C) was applied. The m/z spectra and the data for the selected ion monitoring (SIM) mode were recorded at m/z for glutathione 308→179. Cadmium concentration was measured by a differential pulse adsorptive stripping voltammetry (DPASV) after deposition on a hanging mercury drop electrode (HMDE) at potential −0.7 V (accumulation time 180 s, acetate buffer of pH 3.6, 22 °C). An AUTOLAB with a VA-Stand 663 and a three-electrode system consisting of the HMDE as a working electrode with area 0.4 mm2, an Ag/AgCl/3 mol l−1 KCl as a reference electrode and a Pt-wire as an auxiliary electrode was employed. The maize kernels exposed to the highest cadmium concentration (100 μmol l−1) germinated formerly and much better. A rapid increase of the fresh weight probably relates with more intensive uptake of water in order to decrease cadmium concentration. An intensive preservation of homeostasis of Cd2+ ions in the germinating plants by defending mechanisms might explain differences of uptake rate of cadmium. The linear increase of GSH content with the exposure time at all studied concentration suggests the defending mechanisms might be triggered by concentrations of a heavy metal.  相似文献   

5.
A simple, fast and reliable method, with a low detection limit, has been developed for the determination of total mercury in saliva samples. The method uses a brominating reagent, followed by on-line addition of KMnO4 at room temperature to convert organically bound mercury to inorganic mercury ions, and determines mercury by flow-injection cold-vapour atomic absorption spectrometry. Using the method described, complete recoveries of five mercury compounds from saliva were attained. Results obtained on real samples using the new method were comparable to that obtained using the established method with batch system. The detection limit of this method, based on three standard deviations of the blank, is 0.05 μg l−1 Hg in a saliva sample of 500 μl. A sample throughput of 80 measurements per hour is possible with the method. The calibration curves are linear up to 20 μg l−1 and the dynamic range extends to 40 μg l−1 Hg. At a concentration of 1μg l−1 mercury in saliva, the relative standard deviation is about 2% for 11 replicates; a total volume of 0.5 ml saliva is required for three replicates.  相似文献   

6.
The bismuth film electrode (BiFE), in combination with anodic stripping voltammetry, offers convenient measurement of low concentrations of tin. The procedure involves simultaneous in situ formation of the bismuth film electrode on a glassy carbon substrate electrode, together with electrochemical deposition of tin, in a non-deaerated model solution containing bismuth ions, catechol as complexing agent and the metal analyte, followed by an anodic stripping scan. The BiFE is characterized by an attractive electroanalytical performance, with two distinct voltammetric stripping signals corresponding to tin, accompanied with low background contributions. Several experimental parameters were optimized, such as concentration of bismuth ions and catechol, deposition potential, deposition time and pH of the model solution. In addition, a critical comparison is given with bare glassy carbon and mercury film electrodes, revealing the superior characteristics of BiFE for measurement of tin. BiFE exhibited highly linear behavior in the examined concentration range from 1 to 100 μg L−1 of tin (R2 = 0.997), an LoD of 0.26 μg L−1 tin, and good reproducibility with a calculated R.S.D. of 7.3% for 10 μg L−1 tin (n = 10). As an example, the practical applicability of BiFE was tested with the measurement of tin in a real sample of seawater.  相似文献   

7.
The electronics and construction for an end-column ultramicroelectrode (3–10 μm) detection system that permits the use of medium-sized capillaries (25 μm I.D.) without appreciable effects from the potential field at the end of the capillary. Normal peak-to-peak noise over 10 s was 0.01–0.1 pA. The background noise observed for a 200 × μm carbon-fiber electrode placed either 180 μm within a 25-μm capillary or at a point 500 μm away from the capillary was essentially the same. A study of detector response as a function of the position of the electrode has shown that accurate location of the electrode is important for sensitive and reproducible detection. These studies also showed that differences between the density of the electrolyte existing the capillary and the electrolyte in the detection cell could cause anomalous electrode response depending on the location of the electrode relative to the end of the capillary. Application of a carbon fiber or an Hg film electrode gave detection limits (twice the peak-to-peak noise over 10 s) of 2 · 10−8 mol/l for Pb2+, 1 · 10− 5 mol/l for NO2 and 5 · 10−10 mol/l for catechol.  相似文献   

8.
Stripping analysis has been widely recognised as a powerful tool for trace metal analysis. Its remarkable sensitivity is attributed to the combination of a preconcentration step coupled with differential measurements that generate an extremely favourable signal-to-noise ratio. Mercury electrodes have been traditionally employed for achieving high reproducibility and sensitivity of the stripping technique. However, because of the toxicity of mercury, new alternative electrode materials are highly desired, particularly for on-site environmental monitoring of trace pollutants. Bismuth is an electrode material characterized by its low toxicity and its ability to form alloys with some metals of interest like cadmium, lead or zinc, allowing their preconcentration at the electrode surface. We present here the preparation of Cu/Nafion/Bi electrodes and their application to heavy metal analysis by anodic stripping voltammetry. First, the main limitations of the basic Cu/Bi electrode for on-site monitoring in natural waters are highlighted. Then the modification of the Cu/Bi electrode by a Nafion membrane is presented. The analytical performances of this new electrode for trace cadmium and lead analysis were evaluated in non-deaerated solutions. Linear calibration curves were obtained in synthetic solutions for concentrations ranging from 2 to 12 and 2 to 18 μg L−1 for cadmium and lead, respectively, with relative standard deviations lower than 5% (n = 15). The analytical methodology was then successfully applied to monitor the Cd2+ and Pb2+ content in real samples such as ground water and aquatic plant extracts. The results favourably compared to those obtained using a mercury drop electrode and were validated by ICP-MS.  相似文献   

9.
An electrochemiluminescence (ECL) sensor with good long-term stability and fast response time has been developed. The sensor was based on the immobilization of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) into the Eastman-AQ55D–silica composite thin films on a glassy carbon electrode. The ECL and electrochemistry of Ru(bpy)32+ immobilized in the composite thin films have been investigated, and the modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and chlorpromazine (CPZ) in a flow injection analysis system and showed high sensitivity. Because of the strong electrostatic interaction and low hydrophobicity of Eastman-AQ55D, the sensor showed no loss of response over 2 months of dry storage. In use, the electrode showed only a 5% decrease in response over 100 potential cycles. The detection limit was 1 μmol l−1 for oxalate and 0.1 μmol l−1 for both TPA and CPZ (S/N=3), respectively. The linear range extended from 50 μmol l−1 to 5 mmol l−1 for oxalate, from 20 μmol l−1 to 1 mmol l−1 for TPA, and from 1 μmol l−1 to 200 μmol l−1 for CPZ.  相似文献   

10.
Wei Wei Zhu  Nian Bing Li  Hong Qun Luo   《Talanta》2007,72(5):1733-1737
A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at −1.4 V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from −1.4 to −0.4 V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 μg l−1 for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results.  相似文献   

11.
Glucose oxidase was immobilized onto electrodes by co-deposition from an aqueous solution containing the diluted ion-exchange polymer Nafion. The cationic exchange property of the polymer was used to provide high local concentrations of l,1'-dimethylferricinium (DMFc+) mediator in the film by exchange from solution. The mediated electrodes were operated at +200 mV (vs. ), and the Nafion film was shown to reduce interfering current from ascorbate anion. Cyclic voltammetric analysis revealed a fourteen-fold increase in the effective DMFc+ activity at the electrode after extraction into the film. The sensitivity to glucose was 52 μA/cm2/mM in a solution containing 0.09 mM DMFc+, which is at least three-fold greater than reported for similar electrodes using hydrogen peroxide detection at +650 mV, with a response time of less than 1 min for a 10 μm thick membrane. Oxygen interference was significant, requiring deaeration of the solution before analysis. The electrodes exhibited no significant decrease in sensitivity for more than 50 days on storage in acetate buffer. Electrodes covered with 8000 MWCO dialysis membrane slowed the exchange of DMFc+ with the solution such that the Nafion film functioned as a mediator reservoir. This permitted reagentless analysis of glucose, typically capable of twenty assays when measuring concentrations between 0.1 and 1 mM. The sensitivity for glucose was 7.85 μA/cm2/mM, which is 15% of the sensitivity for the electrode without the dialysis membrane. The detection limit was 20 μM, with a linear range extending to about 3 mM, giving a dynamic range of over two orders of magnitude. Thus where some sacrifice of sensitivity and response rate may be made, the dialysis membrane cover enables multiple analyses in a reagentless biosensor scheme.  相似文献   

12.
Molybdenum(VI) is determined by anodic stripping voltammetry using a carbon paste electrode modified in situ with cetyltrimethylammonium bromide (CTAB). The preconcentration of molybdenum is performed by adsorption and reduction of ion-pairs of cetyltrimethylammonium and molybdenum(VI) oxalate at a potential of −0.4 V vs. the saturated calomel electrode (SCE). The supporting electrolyte contains 0.01 M oxalic acid and 0.075 mM CTAB. Differential pulse anodic stripping voltammetry exploiting the reoxidation signal is used for the determination of trace levels of molybdenum(VI). Linearity between current and concentration exists for a range of 0.5–500 μg 1−1 Mo with proper preconcentration times; the limit of detection (calculated as 3σ) is 0.04 μg 1−1 with an accumulation period of 10 min.  相似文献   

13.
The photocatalytic degradation of organochlorine pesticides including -, β-, γ-, δ-hexachlorobenzene (BHC), dicofol and cypermethrin were carried out on a nano-TiO2 coated films under UV irradiation in the air. The photocatalytic conditions, including the amount of TiO2, irradiation time and the intensity of light were optimized. The pesticides were most effectively degraded under the condition of 2.24 mg/cm2 on TiO2 film and a 400 W UV irradiation of high-pressure mercury lamp with a wavelength of 365 nm. A typical organochlorine pesticide, 20 μg -BHC, was dipped onto the TiO2 film surface and degraded completely within 20 min. In addition, the photocatalytic degradation pathways on the nano-TiO2 coated film were discussed.  相似文献   

14.
The refreshable mercury film silver based electrode Hg(Ag)FE applied for determination of Cr(VI) traces using catalytic adsorptive striping voltammetry (CAdSV) will be presented. The film electrode is characterized by its very good surface reproducibility (not less than 2%) and long-term stability (1500–2000 measurement cycles). The mechanical refreshing of mercury film is realized in the specially constructed device, in a time shorter than 1–2 s.

In the paper, it will be proved that a mechanically weak hanging mercury drop electrode (HMDE) may be substituted by mercury film Hg(Ag)FE electrode with a surface area adjustable from 1.5 to 12 mm2. For the electrode surface 4 mm2 the detection limit obtained for Cr(VI) was 0.19 nM, while the linearity range measured for a 20 s accumulation time was between 0.5 and 50 nM. The relative standard deviation (R.S.D.) in determination of Cr(VI) varied from 1 to 5%. The influence of the excess of Cr(III) on determination of Cr(VI) was analyzed using samples from the Dobczyce reservoir spiked with known amounts of Cr(VI) and Cr(III).  相似文献   


15.
Du J  Li Y  Lu J 《Talanta》2001,55(6):183-1058
It was found that the weak chemiluminescence produced from the reaction of polyhydroxy phenols with luminol in alkaline solution could be strongly enhanced by ferricyanide and ferrocyanide. Based on this found, a new flow injection chemiluminescence method is proposed for the determination of four polyhydroxy phenols: pyrogallol, phlorglucinol, quinol and resorcinol. The detection limits of the method are 0.03 μg ml−1 pyrogallol, 0.03 μg ml−1 phlorglucinol, 0.04 μg ml−1 quinol, and 0.02 μg ml−1 resorcinol. The possible mechanism of CL reactions is also discussed briefly.  相似文献   

16.
Agnihotri NK  Singh VK  Singh HB 《Talanta》1993,40(12):1851-1859
Derivative photometric methods for trace analysis of Th(IV) and UO2(II), and their simultaneous determination in mixtures using 5,8-dihydroxy-1,4-naphthoquinone in a micellar medium are reported. Molar absorptivity and Sandell's sensitivity of 1:2 Th(IV) and 1:1 UO2(II) complexes at their λmax, 614.5 nm and 637.0 nm are, 1.19 × 104 1/mol/cm and 1.12 × 104 1/mol/cm and 1.95 × 10−2 μg/cm2 and 2.13 × 10−2 μg/cm2 μg/cm2, respectively. Calibration graph is linear over the range 9.28 × 10−2−18.56 μg/ml of Th(IV) and 9.52 × 10−2−19.04 μg/ml of UO2(II). Though presence of Th(IV) and UO2(II) causes interference in each others determination, 9.28 × 10−1−9.28 μg/ml Th(IV) and 9.52 × 10−1−9.52 μg/ml UO2(II) when present together, can be simultaneously determined using derivative spectra.  相似文献   

17.
The proposed method for cyanide determination at the ultratrace level by differential pulse voltammetry is based in the sensitivity enhancement obtained when both Cu(II) and EDTA are present in the background electrolyte. Comparison of the detection limits and linear dynamic ranges using the conventional borate (pH 9.75), and the proposed borate-EDTA–Cu(II) background electrolytes was carried out. Best results have been obtained with the addition of 0.5 mmol l−1 EDTA and 0.02 mmol l−1 of Cu(II), which allow a detection limit of 1.7 μg l−1 CN (65 nmol l−1 — absolute detection limit 34 ng) with a precision better than ±2% for a 40 μg l−1 level. Calibration range extended from detection limit up to 100 μg l−1. Cyclic voltammetry indicates that the measured cyanide peak is obtained when the electrogenerated CuCN adsorbed onto the hanging mercury drop electrode surface, is oxidised at positive going potential scan. The method has been successfully applied to various industrial waste waters such as metal-finishing waste waters, water/sand mixtures from cleaning processes of coke production, leachates from wastes obtained from electrolytic cells of aluminium production, and liquors from gold extraction industry. Results obtained by the proposed method showed good agreement with those obtained by the standard methods (ion-selective potentiometry and the spectrophotometric pyridine method).  相似文献   

18.
Burakham R  Oshima M  Grudpan K  Motomizu S 《Talanta》2004,64(5):1259-1265
A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03–0.30 μg NO2-N ml−1 and 0.10–1.00 μg NO3-N ml−1. The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9 ng NO2-N ml−1 and 2.3 ng NO3-N ml−1, respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples.  相似文献   

19.
This paper describes a method for the simultaneous determination of As(III), Sb(III) and Se(IV) by combining hydride generation and gas phase molecular absorption spectrometry. A system for continuous hydride generation has been designed and developed, based on the use of a double process of gas-liquid separation, and optimal compromise operation conditions for the three compounds have been found. After generation, the hydrides are collected in a liquid nitrogen cryogenic trap, and then evaporated and driven to the flow cell of a diode array spectrophotometer, in which the transient signals over the 190–250 nm wavelength interval are measured. Under the recommended conditions (sample flow: 35 ml min−1, 0.5 M HCl; reductor flow: 4 ml min−1 of 4% NaBH4, solution) linear response ranges above 50 μg 1−1 for As(III), 30 μg 1−1 for Sb(III) and 200 μg 1−1 for Se(IV) are obtained with detection limits of 22 μg 1−1, 15 μg 1−1 and 65 μg 1−1, respectively. Multiwavelength linear regression equations were used for the simultaneous determination of the three elements in different synthetic samples, with good precision and accuracy and to study simultaneously the interference from different chemical species for the three compounds. Results were similar to those obtained by other techniques using hydride generation.  相似文献   

20.
Natural salt minerals often contain inclusions of saturated salt solutions with diameters from 1 to> 100 μm. With the quantification of the composition of the fluid inclusions, the origin and metamorphism of the salt rocks can be interpreted. Hence, these data are important concerning the long-term safety of underground repositories in salt rocks [1]. For the extraction of the solutions in fluid inclusions with diameters 300 μm, an optical precision instrument was developed. For the simultaneous determination of Cl, Br, SO42−, Li+, Na+, K+, Mg2+ and Ca2+ two ion chromatographic systems with conductivity detection for cations and anions and additional photometric detection for Br were used. To prevent column overload, the Cl concentration must be less than 50 μg/ml in the measuring solution. The extracted samples (volumes> 0.1 μl) are diluted with demineralized water by a factor of 1 · 104 (20-μl sample loops). The practical limit of determination for the measured elements is 0.01–0.3 μg/ml in the measuring solutions. By calculation of the anion and cation charge balance (molar equivalence), a relative error of <5% for the analysis of fluid inclusions was found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号