首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Affinity chromatography is the most selective chromatographic method for the purification of biologically active materials. It is based on the biospecific interaction of the substrates with a ligand, which is chemically immobilized onto a suitable matrix (support). Different matrices provided by natural and synthetic polymers are used for the preparation of affinity supports. In this communication we describe and compare the properties of various supports based on polysaccharides, polyacrylamides and inorganic materials. In particular, we discuss the utility of different silica derivatives (especially primary hydroxyl silica) for the immobilization of ligands and high-performance affinity chromatography.  相似文献   

2.
3.
A new coupling strategy using pre-packed diol-silica supports to obtain affinity columns for high-performance affinity chromatography (HPAC) is described. These columns were prepared by "in flow" activation in which solutions containing anhydrous solutions of CNBr and triethylamine are separately pumped to a mixer and then onto a pre-packed diol-silica column. Recycling the amino ligand to be coupled several times over the activated silica diol columns results in ligand immobilization. DNA (the Op 1 lac operator), 6-aminohexyl-Cibacron and a peptide (melittin) were all successfully "in flow" coupled to freshly activated columns. Methods for CNBr activation of pre-packed diol-silica column were developed for one, two or three pump HPLC systems. The supports were successfully used for the HPAC purification of a Lac repressor-beta-galactosidase fusion protein, alcohol dehydrogenase, and calmodulin. Columns prepared by in flow activation/coupling procedures were shown to be stable for at least 14 months. Also, in flow activated silica columns could be stored in anhydrous acetone for at least 3 months prior to coupling. Our experiments with these affinity ligand columns (DNA-silica, aminohexyl-Cibacron F3GA-silica, and melittin-silica), suggests that this is a very successful coupling protocol for producing a variety of HPAC columns.  相似文献   

4.
The ruggedness evaluation of an analytical method is now generally required for further validation. By considering ruggedness at an early stage of method development, major disappointments and amount of work could be avoided. This work shows that the optimization software OSIRIS can be helpful for the chromatographer during a method development, as it takes into account the method ruggedness. The ruggedness of the analysis conditions is then evaluated all along the selectivity optimization procedure. This optimization software belongs to the interpretive methods that consist of predicting the optimum conditions by modeling first the solute retention over the parameter space using a minimum number of preliminary runs. The choice of a response function is studied. This response function must be able to take into account several individual criteria: analysis time, minimal resolution and ruggedness of each parameter. Some optimum separations, determined using a ruggedness criteria or not, are given and compared in terms of long term repeatability.  相似文献   

5.
Spatially addressable combinatorial libraries were synthesized by solution phase chemistry and screened for binding to human serum albumin. Members of arylidene diamide libraries were among the best hits found, having submicromolar binding affinities. The results were analyzed by the frequency with which particular substituents appeared among the most potent compounds. After immobilization of the ligands either through the oxazolone or the amine substituent, characterization by surface plasmon resonance showed that ibuprofen affected the binding kinetics, but phenylbutazone did not. It is therefore likely that these compounds bind to Site 2 in sub domain IIIA of human serum albumin (HSA).  相似文献   

6.
Summary A computer-assisted method is presented for mobile phase selection for the optimal separation of pesticides by HPTLC and HPLC. The system is based on a plot of solute retention value and separation criterion vs. binary mobile phase composition for graphic optimization. The result of HPTLC can be transposed to HPLC for optimal separation. The transposition equation is given.  相似文献   

7.
Preparation methods of monolithic silica columns for HPLC including the surface modification were reviewed. Chemical modification methods recently reported to obtain stationary phases for reversed-phase (RP), chiral, ion-exchange, and hydrophilic interaction chromatography (HILIC) separations were discussed. Recent results related to preparation methods of monolithic silica were also covered. The characteristics and properties of silica monoliths and some applications of monolithic silica columns for different analytical and bioanalytical fields will be commented.  相似文献   

8.
9.
The combined use of silica-based chromatographic supports with immobilized affinity ligands can be used in many preparative and analytical applications. One example is the use of silica-based affinity columns in HPLC, giving rise to a method known as high-performance affinity chromatography (HPAC). This review discusses the role that silica has played in the development of affinity chromatography and HPAC and the applications of silica in these methods. This includes a discussion of the types of ligands that have been employed with silica and the methods by which these ligands have been immobilized. Various formats have also been presented for the use of silica in affinity chromatographic methods, including assays involving direct or indirect analyte detection, on-line or off-line affinity extraction, and chiral separations. The use of silica-based affinity columns in studies of biological systems based on zonal elution and frontal analysis methods will also be considered.  相似文献   

10.
An overview of the advantages gained in coupling a flow-injection manifold to a liquid chromatograph is presented. Improvements in the analytical features arising from this association and the peculiar pre- and postcolumn arrangements are discussed, as are the promising prospects of arrangements to be developed for avoiding the preliminary steps of the analytical process.  相似文献   

11.
In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.  相似文献   

12.
Silica microspheres have been synthesized by phase separation and sol–gel transition coupled with emulsion method. The as-obtained material is characterized by scanning electron microscopy, nitrogen sorption, elemental analysis and particle size distribution measurements. The results demonstrated that the material featured with hierarchically porous structure, possessing both mesopores and penetrable macropores. The mesopores provide large surface area while the macropores traverse the silica particles, which may facilitate fast mass transfer as well as guarantee low backpressure when such materials are used for packed high-performance liquid chromatography (HPLC) column. Therefore, their preliminary applications as HPLC packings in fast separation and low-pressure separation have been attempted in the present study. Benzene, benzaldehyde and benzyl alcohol were separated within two minutes on the silica column at a flow rate of 7 mL min−1. Vitamin E mixtures can also be baseline separated at a high flow rate of 8 mL min−1. In addition, thirteen aromatic hydrocarbons were well separated on the octadecyl-bonded silica (ODS) column. In comparison with a commercial Kromasil ODS column, the pressure of the proposed column is much lower (<1/2) under the same chromatographic conditions, while comparable separation efficiency can be achieved.  相似文献   

13.
Three anthraquinone glutathionyl-biomimetic dye ligands, comprising as terminal biomimetic moiety glutathione analogues (glutathionesulfonic acid, S-methyl-glutathione and glutathione) were synthesised and characterised. The biomimetic ligands were immobilised on agarose gel and the affinity adsorbents, together with a nonbiomimetic adsorbent bearing Cibacron Blue 3GA, were studied for their purifying ability for the glutathione-recognising enzymes, NAD+-dependent formaldehyde dehydrogenase (FaDH) from Candida boidinii, NAD(P)+-dependent glutathione reductase from S. cerevisiae (GSHR) and recombinant maize glutathione S-transferase I (GSTI). All biomimetic adsorbents showed higher purifying ability for the target enzymes compared to the nonbiomimetic adsorbent, thus demonstrating their superior effectiveness as affinity chromatography materials. In particular, the affinity adsorbent comprising as terminal biomimetic moiety glutathionesulfonic acid (BM1), exhibited the highest purifying ability for FaDH and GSTI, whereas, the affinity adsorbent comprising as terminal biomimetic moiety methyl-glutathione (BM2) exhibited the highest purifying ability for GSHR. The BM1 adsorbent was integrated in a facile two-step purification procedure for FaDH. The purified enzyme showed a specific activity equal to 79 U/mg and a single band after sodium dodecylsulfate-polyacrylamide gel electrophoresis analysis. Molecular modelling was employed to visualise the binding of BM1 with FaDH, indicating favourable positioning of the key structural features of the biomimetic dye. The anthraquinone moiety provides the driving force for the correct positioning of the glutathionyl-biomimetic moiety in the binding site. It is located deep in the active site cleft forming many favourable hydrophobic contacts with hydrophobic residues of the enzyme. The positioning of the glutathione-like biomimetic moiety is primarily achieved by the strong ionic interactions with the Zn2+ ion of FaDH and Arg 114, and by the hydrophobic contacts made with Tyr 92 and Met 140. Molecular models were also produced for the binding of BM1 and BM3 (glutathione-substituted) to GSTI. In both cases the biomimetic dye forms multiple hydrophobic interactions with the enzyme through binding to a surface pocket. While the glutathioine moiety of BM3 is predicted to bind in the crystallographically observed way, an alternative, more favourable mode seems to be responsible for the better purification results achieved with BM1.  相似文献   

14.
Summary There are a number of parameters which have to be chosen depending on the analysis being done in gas chromatography. While the choice of stationary phase material is based on the solutes to be separated, the thickness is dependent on the concentration and the volatility of the components to be analyzed. This study undertakes a coupled column phase ratio optimization by connecting a short piece of a particular column prior to a normal length of an analytical column. Various columns of different dimensions (phase ratio), but of the same stationary phase material (methyl silicone), are coupled together by a deactivated glass press-fit connector, and the efficiency and capacity are measured. The coupling of fused silica open tubular columns is optimized in efficiency by matching or decreasing the phase ratio of successive columns. Capacity optimization is accomplished by increasing the phase ratio of consecutive columns. Capacity and efficiency optimization are opposing each other; therefore, if some efficiency can be sacrificed a substantial increase in capacity is possible.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of demecarium bromide and related process intermediate and companion products is described. The compounds of interest are separated by isocratic reversed-phase chromatography on a mu Bondapak CN column using UV detection. The reproducibility of the method and stability of demecarium bromide is demonstrated. Applications presented for the method include quantitation of demecarium bromide in aqueous solutions and control of the raw material.  相似文献   

16.
Very fast reversed-phase separations of biomacromolecules are performed using columns made with superficially porous silica microsphere column packings ("Poroshell"). These column packings consist of ultra-pure "biofriendly' silica microspheres composed of solid cores and thin outer shells with uniform pores. The excellent kinetic properties of these new column packings allow stable, high-resolution gradient chromatography of polypeptides, proteins, nucleic acids, DNA fragments, etc. in a fraction of the time required for conventional separations. Contrasted with <2-microm non-porous particles, Poroshell packings can be used optimally with existing equipment and greater sample loading capacities, while retaining kinetic (and separation speed) advantages over conventional totally porous particles.  相似文献   

17.
The aim of the study described in this report has been the development and the evaluation of a new improved interface to be operated under continuous heating, for on-line coupling solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC). Heating is desirable to increase desorption rate and decrease carryover. The results obtained have been compared with that obtained by off-line desorption and online desorption without heating. The SPME-HPLC interface described here has an inner volume of 60 microL, fixation for infinite points and a novel leak less sealing system. When the heating system was used, the area values were almost 10-fold higher than that obtained using the off-line mode. The obtained chromatograms showed an increasing of the area and height of chromatographic peaks and proved the excellent performance and reproducibility of the interface developed in this work.  相似文献   

18.
19.
Native mesoporous silica beads were subjected to a sequence of post-treatment procedure including hydrochloric acid treatment, calcination and subsequent rehydroxylation. The post-treated silica beads were converted into RP-18 silica by silanization with monochloro- and dimethoxy-n-octadecylsilanes, respectively. The influence of post-treatments and silanization conditions on the physico–chemical characteristics and on the chromatographic behaviour of the RP-silicas was studied. Also the changes of the pore structural parameters and the silanol group densities during the post-treatment and silanization were assessed.  相似文献   

20.
Shi Z  Fu C 《Talanta》1997,44(4):593-604
The role of porphyrins in the determination of metal ions by high-performance liquid chromatography (HPLC) is examined. In assessing the current status of the area, recent advances and developments are discussed and future potential is pointed out.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号