首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Histidine-tagged lentiviral vectors were separated from crude cell culture supernatant using labscale monolithic adsorbents by immobilized metal affinity chromatography. The capture capacity, concentration factor, purification factor, and elution efficiency of a supermacroporous cryogel monolith were evaluated against the BIA Separations convective interaction media (CIM) disc, which is a commercial macroporous monolith. The morphology of the polymeric cryogel material was characterised by scanning electron microscopy. Iminodiacetic acid was used as the metal chelating ligand in both monoliths and the chelating capacity for metal ions was found to be comparable. The CIM-IDA-Ni(2+) adsorbent had the greatest capture capacity (6.7 x 10(8) IU/ml of adsorbent), concentration factor (1.3-fold), and elution efficiency (69%). Advantages of the cryogel monoliths included rapid, low pressure processing as well low levels of protein and DNA in the final purified vector preparations.  相似文献   

2.
A continuous supermacroporous matrix has been developed allowing direct capture of enzyme from non-clarified crude cell homogenate at high flow-rates. The continuous supermacroporous matrix has been produced by radical co-polymerization of acrylamide, allyl glycidyl ether and N,N'-methylene-bis(acrylamide) which proceeds in aqueous solution of monomers frozen inside a column (cryo-polymerization). After thawing, the column contains a continuous matrix having interconnected pores of 10-100 microm size. Iminodiacetic acid covalently coupled to the cryogel is a rendering possibility for immobilized metal affinity chromatographic purification of recombinant His-tagged lactate dehydrogenase, (His)6-LDH, originating from thermophilic bacterium Bacillus stearothermophilus, but expressed in Escherichia coli. The large pore size of the adsorbent makes it possible to process particulate-containing material without blocking the column. No preliminary filtration or centrifugation is needed before application of crude extract on the supermacroporous column. A total of 210 ml crude homogenate, 75 ml of it non-clarified, was processed on a single 5.0 ml supermacroporous column at flow speeds up to 12.5 ml/min without noticeable impairment of the column properties. Mechanically the cryogel adsorbent is very stable. The continuous matrix could easily be removed from the column, dried at 70 degrees C and kept in a dry state. After rehydration and reinsertion of the matrix into an empty column, (His)6-LDH was purified as efficiently as on the newly prepared column. The procedure of manufacturing the supermacroporous continuous cryogel is technically simple. Starting materials and initiators are cheap and available and are simply mixed and frozen under specified conditions. Altogether these qualities reveal that the supermacroporous continuous cryogels is a very interesting alternative to existing methods of protein purification from particulate-containing crude extracts.  相似文献   

3.
Suitable conditions for separating cells using a chromatographic procedure were evaluated in parallel chromatography on minicolumns. A 96-hole minicolumn plate filled with cryogel monoliths (18.8 mm x 7.1 mm ?) with immobilized concanavalin A was used. Chromatographic columns (113 mm x 7.1 mm ?) were used for chromatographic resolution of a mixture of Saccharomyces cerevisiae and Escherichia coli cells. Separation of a cell mixture containing equal amounts of cells of both types performed in a column format under the determined optimal conditions, resulted in a quantitative capture of applied S. cerevisiae cells, while E. coli passed through the column. Bound S. cerevisiae cells were released by flow-induced detachment and by compression of the adsorbent in the presence of 0.3 M methyl alpha-D-manno-pyranoside. The flowthrough and the eluted fractions were analyzed by plate counting and by registering metabolic activity of S. cerevisiae cells in the eluted fractions after capturing on ConA-cryogel monoliths in a 96-minicolumn plate format. The flowthrough fraction contained E. coli cells with nearly 100% purity, whereas the fraction eluted by compression of the adsorbent contained viable S. cerevisiae cells with 95% purity. Thus, an efficient chromatographic separation of cells was achieved using affinity cryogel column.  相似文献   

4.
A new type of supermacroporous, monolithic, cryogel affinity adsorbent was developed, allowing the specific capture of urokinase from conditioned media of human fibrosarcoma cell line HT1080. The affinity adsorbent was designed with the objective of using it as a capture column in an integrated perfusion/protein separation bioreactor setup. A comparative study between the utility of this novel cryogel based matrix and the conventional Sepharose based affinity matrix for the continuous capture of urokinase in an integrated bioreactor system was performed. Cu(II)-ion was coupled to epoxy activated polyacrylamide cryogel and Sepharose using iminodiacetic acid (IDA) as the chelating ligand. About 27-fold purification of urokinase from the conditioned culture media was achieved with Cu(II)-IDA-polyacrylamide cryogel column giving specific activity of about 814 Plough units (PU)/mg protein and enzyme yields of about 80%. High yields (95%) were obtained with Cu(II)-IDA-Sepharose column by virtue of its high binding capacity. However, the adsorbent showed lower selectivity as compared to cryogel matrix giving specific activity of 161 PU/mg protein and purification factor of 5.3. The high porosity, selectivity and reasonably good binding capacity of Cu(II)-IDA-polyacrylamide cryogel column make it a promising option for use as a protein capture column in integrated perfusion/separation processes. The urokinase peak pool from Cu(II)-IDA-polyacrylamide cryogel column could be further resolved into separate fractions for high and low molecular weight forms of urokinase by gel filtration chromatography on Sephacryl S-200. The selectivity of the cryogel based IMAC matrix for urokinase was found to be higher as compared to that of Cu(II)-IDA-Sepharose column.  相似文献   

5.
Yao K  Yun J  Shen S  Wang L  He X  Yu X 《Journal of chromatography. A》2006,1109(1):103-110
A novel continuous supermacroporous monolithic cryogel embedded with nanometer-size particles was prepared by the radical cryogenic co-polymerization of acrylamide (AAm), N,N'-methylene-bis-acrylamide (MBAAm), allyl glycidyl ether (AGE) and the dispersed surfactant-stabilized Fe3O4 nanoparticles under the freezing-temperature variation condition in a glass column. This special separation matrix has interconnected supermacropores with pore size of 10-50 microm, which permit the free-passage of microbial cells or cell debris in the culture fluids and then is interest in downstream processes. The axial liquid dispersion coefficients of the new continuous supermacroporous monolithic bed at different liquid flow rates were obtained by measuring residence time distributions (RTDs) using tracer pulse-response method. The experimental results showed that the axial liquid dispersion within the bed was weak in a wide water flow rate of 0.5-15 cm/min. The axial dispersion coefficient was found to be increased exponentially with the increase of liquid flow rate. Chromatographic process of bovine serum albumin (BSA) in the cryogel monolithic bed was carried out to reveal the protein breakthrough and elution characteristics. Compared with other reported cryogel beds in literature, the protein adsorption capacity of the present cryogel bed was improved due to the embedded nano-sized solid adsorbents in the gel matrix. Microstructure morphology of the embedded nanoparticles in the cryogel and the gel matrix structure were also analyzed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) in this paper.  相似文献   

6.
Graft polymerization of monomer chains with expected functional groups onto the matrix pore surfaces by initiator is an effective approach for introducing ion-exchange groups to cryogel matrix to get anion- or cation-exchange supermacroporous cryogels. In this work, a novel cation-exchange cryogel with sulfo binding groups was prepared by grafting of 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPSA) onto polyacrylamide-based cryogels in glass columns. The grafting polymerization was achieved in an in-situ manner which was performed by pumping the initiator and the reactive solution of graft monomer with sulfo binding groups directly through a cryogel bed pre-produced in a glass column under frozen condition. The axial liquid dispersion characteristics within the monolithic cryogel beds before and after the in-situ polymerization were compared by measuring residence time distributions (RTDs) at various liquid flow rates using tracer pulse-response method. Microstructure morphology of pores within cryogels was analyzed by scanning electron microscopy (SEM). Chromatography of lysozyme was carried out to reveal the protein breakthrough and elution characteristics in the obtained cryogel beds.  相似文献   

7.
In this study, composite monoliths with porous structures were prepared using quaternized chitosan and diatom earth for protein separation. Quaternized chitosan (N-[(2-hydroxy-3-trimethylammonium)propyl] chitosan chloride) dissolved in water was mixed with diatom earth and crosslinked with glutaraldehyde under low-temperature conditions to form a cryogel. Interconnected porous monoliths were obtained after removing ice crystals from the cryogel. The monoliths adsorbed bovine serum albumin selectively from the solution mixture of bovine serum albumin and bovine ɤ-globulin, and bovine ɤ-globulin was recovered in the flow-through fraction. The adsorption selectivity was enhanced by changing the solution pH from 6.8 to 5.5. The adsorption of bovine serum albumin by the monolith was replicated at least five times following its washing with a buffer containing 400 mM NaCl and subsequent regeneration with a 10 mM acetate buffer. The composited monolith is a promising adsorbent for the removal of acidic proteins, such as serum albumin contamination in neutral proteins, for example, ɤ-globulins, in bioproduction processes.  相似文献   

8.
Continuous supermacroporous chromatographic columns with anion-exchange ligands [2-(dimethylamino)ethyl group] and immobilized metal affinity (IMA) ligands (Cu2+-loaded iminodiacetic acid) have been developed allowing binding of Escherichia coli cells and the elution of bound cells with high recoveries. These poly(acrylamide)-based continuous supermacroporous columns have been produced by radical co-polymerization of monomers in aqueous solution frozen inside a column (cryo-polymerization). After thawing, the column contains a continuous matrix (so-called cryogel) with interconnected pores of 10-100 microm in size. The large pore size of the matrix makes it possible for E. coli cells to pass unhindered through a plain column containing no ligands. E. coli cells bound to an ion-exchange column at low ionic strength were eluted with 70-80% recovery at NaCl concentrations of 0.35-0.40 M, while cells bound to an IMA-column were eluted with around 80% recovery using either 10 mM imidazole or 20 mM EDTA solutions, respectively. The cells maintain their viability after the binding/elution procedure. These preliminary results indicate that microbial cells can be handled in a chromatographic mode using supermacroporous continuous columns. These columns are easy to manufacture from cheap and readily available starting materials, which make the columns suitable for single-time use.  相似文献   

9.
The aim of this study is to prepare supermacroporous cryogels embedded with Cu(2+)-attached sporopollenin particles (Cu(2+)-ASP) having large surface area for high protein adsorption capacity. Supermacroporous poly(2-hydroxyethyl methacrylate) (PHEMA)-based monolithic cryogel column embedded with Cu(2+)-ASP was prepared by radical cryo-copolymerization of 2-hydroxyethyl methacrylate (HEMA) with N,N'-methylene-bis-acrylamide (MBAAm) as cross-linker directly in a plastic syringe for affinity purification of human serum albumin (HSA). Firstly, Cu(2+) ions were attached to sporopollenin particles (SP), then the supermacroporous PHEMA cryogel with embedded Cu(2+)-ASP was produced by free radical polymerization using N,N,N',N'-tetramethylene diamine (TEMED) and ammonium persulfate (APS) as initiator/activator pair in an ice bath. Embedded particles (10 mg) in PHEMA-based cryogel column were used in the adsorption/desorption of HSA from aqueous solutions. Optimum conditions of adsorption experiments were performed at pH 8.0 phosphate buffer, with flow rate of 0.5 mL/min, and at 5°C. The maximum amount of HSA adsorption from aqueous solution was very high (677.4 mg/g SP) with initial concentration 6 mg/mL. It was observed that HSA could be repeatedly adsorbed and desorbed to the embedded Cu(2+)-ASP in PHEMA cryogel without significant loss of adsorption capacity.  相似文献   

10.
Sponge-like material was utilized as novel chromatographic media for high throughput analyses. The pore size of the sponge-like material was several dozen micrometer, and was named spongy monolith because it consists of continuous structured copolymers, which was made of poly(ethylene-co-vinyl acetate), such as monolithic materials including silica monoliths and organic polymer monoliths. The spongy monolith was packed into a stainless steel column (100 mm × 4.6 mm I.D.) and evaluated in liquid chromatography (LC) with an on-line column-switching LC concentration system. The results indicate that the packed column could be used with high flow rates and low back pressure (9.0 mL/min at 0.5 MPa). Furthermore, bisphenol A was quantitatively recovered by on-line column-switching LC concentration with the spongy monolithic column. Additionally, the adsorption capacity and physical strength of the media was enhanced via chemical modification of spongy monoliths using glycerol dimethacrylate. The results compared with original spongy monolith demonstrated that a higher adsorption capacity was achieved on a shorter column, and a stable low back pressure was obtained at high throughput elution even with a longer column.  相似文献   

11.
The present paper describes a chromatographic capture/purification step for the recovery of proteins directly from undiluted and unclarified cell culture broths using supermacroporous dimethylacrylamide (DMAA) cryogel. The interconnected character and the size (10-100 microm) of the pores of the adsorbent make it possible to process whole cell fermentation broths without blocking the column. Cu2+-iminodiacetic acid (IDA) DMAA cryogel has been used for the isolation and purification of excreted (His)6-tagged single chain (sc) Fv antibody fragments, (His)6-scFv, from E. coli cell culture. Bound protein was recovered with 0.2 M imidazole or with 20 mM EDTA and was practically cell-free. Chromatographic capture using Cu2+-IDA cryogel column was performed at flow rates of 300 and 600 cm/h, respectively and resulted in 84-96% recovery of (His)6-scFv fragments with a purification factor of 13-15. The DMAA cryogel adsorbent is mechanically stable, can withstand harsh cleaning-in-place procedure and is relatively inexpensive. Chromatographic isolation of proteins using cryogels allows efficient removal of cells and can be operated at a flow rate as high as 600 cm/h. This novel technique has proven to be a scalable process, does not require special equipment and can be a good alternative to expanded bed adsorption and other integrated isolation techniques.  相似文献   

12.
A new approach to the search for residues of unknown growth promoting agents such as anabolic steroids and beta-agonists in feed is presented. Following primary extraction and clean-up, samples are separated using gradient liquid chromatography (LC). The effluent is split towards two identical 96-well fraction collectors and an optional electrospray quadrupole time-of-flight mass spectrometry (QTOFMS) system for accurate mass measurement. One 96-well plate is used for a bioassay (enzyme-immuno assay, receptor assay) and will detect the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate is used for identification by LC/QTOFMS/MS. The value of this LC/bioassay/QTOFMS/MS methodology is highlighted by the finding and structure elucidation of a new beta-agonist in a feed extract.  相似文献   

13.
A novel approach for the fabrication of macroporous poly(glycidyl methacrylate-ethylene glycol dimethacrylate) monolith is presented. The method involved the use of sodium sulfate granules and organic solvents as co-porogens. Compared with the conventional monoliths [ML-(1-3)] using organic solvents only as a porogen, the improved monoliths [MLS-(1-3)] showed not only higher column efficiency and dynamic binding capacity (DBC) for protein (bovine serum albumin, BSA), but also higher column permeability and lower back pressure. It is considered that the superpores introduced by the solid granules played an important role for the improvement of the monolith performance. Moreover, poly(glycidyl methacrylate-diethylamine) tentacles were grafted onto the pore surface of MLS-3 monolith. This has further increased the DBC of BSA to 74.7 mg/ml, about three times higher than that of the monoliths without the grafted tentacles. This grafting does not obviously decrease the column permeability, so a new monolith of high column permeability and binding capacity has been produced for high-performance preparative protein chromatography.  相似文献   

14.
SVEC Frantisek 《色谱》2005,23(6):585-594
 Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography (HPLC) in classical columns in the early 1990s and later extended to the capillary format. These monolithic materials are prepared using simple processes carried out in an external mold (inorganic monoliths) or within the confines of the column (organic monoliths and all capillary columns). These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode. Since all the mobile phase must flow through the monolith, the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations. As a result, the monolithic columns perform well even at very high flow rates. The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.  相似文献   

15.
A novel mercaptotetrazole‐silica hybrid monolithic column was prepared for capillary liquid chromatography, in which the thiol‐end mercaptotetrazole was mixed with hydrolyzed γ‐methacryloxypropyltrimethoxysilane and tetramethyloxysilane for the co‐polycondensation and thiol‐ene click reaction in a one‐pot process. The effects of the molar ratio of silanes, the amount of mercaptotetrazole, and the volume of porogen on the morphology, permeability and pore properties of the as‐prepared mercaptotetrazole‐silica hybrid monoliths were investigated in detail. A series of test compounds including alkylbenzenes, amides and anilines were employed for evaluating the retention behaviors of the mercaptotetrazole‐silica hybrid monolithic columns. The results demonstrated that the mercaptotetrazole‐silica hybrid monoliths exhibited hydrophobic, hydrophilic as well as ion‐exchange interaction. The run‐to‐run, column‐to‐column and batch‐to‐batch reproducibilities of the mercaptotetrazole‐silica hybrid monoliths were satisfactory with the relative standard deviations less than 1.4 (= 5), 3.9 (= 3) and 4.0% (= 5), respectively. In addition, the mercaptotetrazole‐silica hybrid monolith was further applied to the separation of sulfonamides, nucleobases and protein tryptic digests. These successful applications confirmed the promising potential of the mercaptotetrazole‐silica hybrid monolith in the separation of complex samples.  相似文献   

16.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

17.
Recently, sample preparation has been considered to be the major cause of bottlenecks during high-throughput analysis. With the assistance of robotic liquid handlers and the 96-well plate format, more samples can be prepared for subsequent liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Protein precipitation is still widely used despite potential loss of sensitivity or variable results due to ion suppression. The use of solid-phase extraction (SPE) clearly gives superior results but may not be as cost effective as protein precipitation due to the labor and material costs associated with the process. Here, a novel 96-well SPE plate is described that was designed to minimize the elution volume required for quantitative elution of analytes. The plate is packed with 2 mg of a high-capacity SPE sorbent that allows loading of up to 750 microL of plasma, while the novel design permits elution with as little as 25 microL. Therefore, the plate offers up to a 15-fold increase in sample concentration. The evaporation and reconstitution step that is typically required in SPE is avoided due to the concentrating ability of the plate. Examples of applications in drug discovery/development are shown and results are compared to protein precipitation. Excellent sensitivity and linearity are demonstrated.  相似文献   

18.
This study proposed the development of a monolithic supermacroporous affinity column for direct capture of lactoperoxidase, a glycoprotein present in milk, whey, and colostrum, with several applications due to its wide antimicrobial activity. A poly(acrylamide)-based cryogel was produced by radical co-polymerization of monomers in frozen aqueous solution and activated with p-aminobenzenesulfonamide as a ligand for specific interaction with the lactoperoxidase. The axial liquid dispersion coefficients at different liquid flow rates were determined by measuring residence time distributions using the tracer pulse-response method. The axial dispersion coefficient was low and the height equivalent to theoretical plate was not dependent on the flow velocity. The adsorptive capacity of affinity cryogel was studied as a function of flow velocity and the best condition was 0.9 cm/min. The response surface methodology was applied to optimize the capture of the enzyme, as a function of pH and salt concentration. Higher purification factor value was found at a salt concentration of 80 mmol/L and pH of 8.0 (p < 0.05). There was no influence of the variables under study on the yield (p > 0.05). The results indicated that affinity cryogel is a promising chromatography support for the use in high-throughput one-step purification of lactoperoxidase from whey.  相似文献   

19.
The development of organic porous polymer monoliths represents an alternative approach to stationary phase design. The use of these materials has helped to rekindle interest in capillary electrochromatography. Although a large number of investigations have explored different monolith recipes, polymerization conditions, and application challenges, few investigations have addressed the fundamentals of this separation mode with this type of material. This study addresses the thermodynamics of the reversed phase retention mechanism on 100% butyl acrylate and 1:3 butyl:lauryl acrylate (volume/volume ratio) porous polymer monoliths used in a capillary electrochromatography mode. Linear van't Hoff plots yield enthalpies of retention of ?3.9 to ?14.3 kJ/mol on two different, but related columns for five selected hydrophobic analytes across a thirty degree temperature range. Minimum plate heights were only moderately impacted over this temperature range.  相似文献   

20.
A novel separation method was developed to isolate directly cytidine triphosphate (CTP) from fermentation broth of yeast using anion-exchange supermacroporous cryogel. The anion-exchange cryogel with tertiary amine groups was prepared by graft polymerization. The breakthrough characteristics and elution performance of pure CTP in the cryogel bed were investigated experimentally and the CTP binding capacity was determined. Then the separation experiments of CTP from crude fermentation broth of yeast using the cryogel column were carried out using deionized water and 0.01 M HCl as washing buffer, respectively. The chromatographic behavior was monitored and analyzed. The purity and concentration of the obtained CTP in these processes were determined quantitatively by HPLC. The maximal purity of CTP obtained at the condition of 0.01 M HCl as washing buffer and 0.5 M NaCl in 0.01 M HCl as elution buffer reached 93%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号