 共查询到20条相似文献,搜索用时 45 毫秒
1.
2.
Solvent optimization is an important procedure in desorption electrospray ionization (DESI) and in this study the effects of solvent surface tension are explored. Data are presented for methanol/water/surfactant solvent systems, which show increases in ion signals of more than an order of magnitude when low concentrations of surfactants are added to the standard methanol/water (1:1) spray solvent. Examples of analytes tested include food chemicals, peptides, pharmaceuticals, and drugs of abuse. The improvement in ion intensity is mainly attributed to the effect of surface tension in producing smaller spray droplets, which are shown to cover a larger surface area. Surfactant-containing spray solutions allowed extension of DESI-MS analysis to previously intractable analytes like melamine and highly hydrophobic compounds like the sudan dyes.  相似文献   

3.
The salt tolerance of desorption electrospray ionization (DESI) was systematically investigated by examining three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl (1:1) from different surfaces. At physiological salt concentrations, the individual drugs in each mixture were observed in each experiment. Even at salt concentrations significantly above physiological levels, particular surfaces were effective in providing spectra that allowed the ready identification of the compounds of interest in low nanogram amounts. Salt adducts, which are observed even in the absence of added salt, could be eliminated by adding 0.1% 7 M ammonium acetate to the standard methanol:water (1:1) spray solvent. Comparison of the salt tolerance of DESI with that of electrospray ionization (ESI) demonstrated better signal/noise characteristics for DESI. The already high salt tolerance of DESI can be optimized further by appropriate choices of surface and spray solution.  相似文献   

4.
Desorption electrospray ionization mass spectrometry (DESI‐MS) requires little to no sample preparation and has been successfully applied to the study of biologically significant macromolecules such as proteins. However, DESI‐MS and other ambient methods that use spray desorption to process samples during ionization appear limited to smaller proteins with molecular masses of 25 kDa or less, and a decreasing instrumental response with increasing protein size has often been reported. It has been proposed that this limit results from the inability of some proteins to easily desorb from the surface during DESI sampling. The present study investigates the apparent mass dependence of the instrumental response observed during the DESI‐MS analysis of proteins using spray desorption collection and reflective electrospray ionization. Proteins, as large as 66 kDa, are shown to be quantitatively removed from surfaces by using spray desorption collection. However, incomplete dissolution and the formation of protein–protein and protein–contaminant clusters appear to be responsible for the mass‐dependent loss in sensitivity for protein analysis. Alternative ambient mass spectrometry approaches that address some of the problems encountered by spray desorption techniques for protein analysis are also discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
Sulfated oligosaccharides derived from glycosaminoglycans (GAGs) are fragile compounds, highly polar and anionic. We report here on the rare but successful application of desorption electrospray ionization (DESI) — LTQ‐Orbitrap mass spectrometry (MS) to the high‐resolution analysis of anionic and sulfated oligosaccharides derived from the GAGs hyaluronic acid and heparin. For that purpose, key parameters affecting DESI performance, comprising the geometric parameters of the DESI source, the probed surface and the spraying conditions, applied spray voltage, flow rates and solvent composition were investigated. Under suitable conditions, the DESI technique allows the preservation of the structural integrity of such fragile compounds. DESI enabled the sensitive detection of anionic hyaluronic acid and heparin oligosaccharides with a limit of detection (LOD) down to 5 fmol (≈10 pg) for the hyaluronic acid decasaccharide. Detection of hyaluronic acid oligosaccharides in urine sample was also successfully achieved with LOD values inferior to the ng range. Multistage tandem mass spectrometry (MSn) through the combination of the DESI source with a hybrid linear ion trap‐orbitrap mass spectrometer allowed the discrimination of isomeric sulfated oligosaccharides and the sequence determination of a hyaluronic acid decasaccharide. These results open promising ways in glycomic and glycobiology fields where structure–activity relationships of bioactive carbohydrates are currently questioned. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

7.
A signal enhancement of two orders of magnitude was achieved when reactive desorption electrospray ionization (DESI) was used to investigate copper(II) dibutyl dithiocarbamate, Cu(II)(bu2dtc)2, found in a specialized polymer. Cu(II) was oxidized to Cu(III) during the DESI experiment by oxidants in the spray solvent. Such oxidants could be present or formed during electrospray (e.g., O2) or deliberately added to the spray solvent (this approach is called reactive DESI). When a strong oxidizing agent (e.g., iodine) was added to the spray solvent, the signal increased by two orders of magnitude relative to the pure solvent spray. The correlation between the standard reduction potential of the oxidant and the signal intensity and signal to noise ratio of the product ion for various reagents, was tested and discussed. The observed DESI enhancements in rates of oxidation are not observed in homogeneous solution. The major peaks in the collision induced dissociation (CID) spectrum of the complex ion Cu(III)(bu2dtc)2]+ were identified using isotopic distributions and MS3 data.  相似文献   

8.
The direct analysis of pharmaceutical formulations and active ingredients from non‐bonded reversed‐phase thin layer chromatography (RP‐TLC) plates by desorption electrospray ionisation (DESI) combined with ion mobility mass spectrometry (IM‐MS) is reported. The analysis of formulations containing analgesic (paracetamol), decongestant (ephedrine), opiate (codeine) and stimulant (caffeine) active pharmaceutical ingredients is described, with and without chromatographic development to separate the active ingredients from the excipient formulation. Selectivity was enhanced by combining ion mobility and mass spectrometry to characterise the desorbed gas‐phase analyte ions on the basis of mass‐to‐charge ratio (m/z) and gas‐phase ion mobility (drift time). The solvent composition of the DESI spray using a step gradient was varied to optimise the desorption of active pharmaceutical ingredients from the RP‐TLC plates. The combined RP‐TLC/DESI‐IM‐MS approach has potential as a rapid and selective technique for pharmaceutical analysis by orthogonal gas‐phase electrophoretic and mass‐to‐charge separation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Volný M  Venter A  Smith SA  Pazzi M  Cooks RG 《The Analyst》2008,133(4):525-531
Time resolved measurements show that during a desorption electrospray ionization (DESI) experiment, the current initially rises sharply, followed by an exponential decrease to a relatively steady current. When the high voltage on the spray emitter is switched off, the current drops to negative values, suggesting that the direction of current flow in the equivalent DESI circuit is reversed. These data demonstrate that the DESI source behaves as a dc capacitor and that the addition of a surface between the sprayer and the counter electrode in DESI introduces a new electrically active element into the system. The charging and discharging behavior was observed using different surfaces and it could be seen both by making current measurements on a plate at the entrance to the mass spectrometer as well as by measuring ion current in the linear ion trap within the vacuum system of the mass spectrometer. The magnitude of the steady state current obtained without analyte present on the surface is different for different surface materials, and different capacitor time constants of the equivalent RC circuits were calculated for different DESI surfaces. The PTFE surface has by far the greatest time constant and is also able to produce the highest DESI currents. Surface properties play a crucial role in charge transfer during DESI in addition to the effects of the chemical properties of the analyte. It is suggested that surface energy (wettability) is an important factor controlling droplet behavior on the surface. The experimental data are correlated with critical surface tension values of different materials. It is proposed, based on the results presented, that super-hydrophobic materials with extremely high contact angles have the potential to be excellent DESI substrates. It is also demonstrated, using the example of the neurotransmitter dopamine, that the surface charge that develops during a DESI-MS experiment can cause electrochemical oxidation of the analyte.  相似文献   

10.
We report high resolution spectra for the medium molecular weight proteins myoglobin and cytochrome-c obtained using a custom desorption electrospray ionisation (DESI) source coupled to a Bruker Daltonics 12 T Apex Qe Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS). The DESI source was designed for accurate alignment and reproduction of critical geometric variables. A two axis motorised stage was included to enable automated rastering of the sample under the DESI plume. Spectra for the intact proteins have been obtained under single-acquisition conditions and a top-down analysis of cytochrome-c was performed using both collision induced dissociation (CID) and electron capture dissociation (ECD) of the isolated [M+15H]15+ charge state. The sequence coverage is comparable to that obtained using electrospray ionisation, demonstrating the utility of top-down protein analysis by DESI FTICR-MS.  相似文献   

11.
A source that couples the desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) techniques together was demonstrated to broaden the range of compounds that can be analyzed in a single mass spectrometric experiment under ambient conditions. A tee union was used to mix the spray reagents into a partially immiscible blend before this mixture was passed through a conventional electrospray (ES) probe capillary. Using this technique, compounds that are ionized more efficiently by the DICE method and those that are ionized better with the DESI procedure could be analyzed simultaneously. For example, hydroquinone, which is not detected when subjected to DESI-MS in the positive-ion generation mode, or the sodium adduct of guaifenesin, which is not detected when examined by DICE-MS, could both be detected in one experiment when the two techniques were combined. The combined technique was able to generate the molecular ion, proton and metal adduct from the same compound. When coupled to a tandem mass spectrometer, the combined source enabled the generation of product ion spectra from the molecular ion and the [M + H]+ or [M + metal]+ ions of the same compound without the need to physically change the source from DICE to DESI. The ability to record CID spectra of both the molecular ion and adduct ions in a single mass spectrometric experiment adds a new dimension to the array of mass spectrometric methods available for structural studies.  相似文献   

12.
Internal energy distributions in desorption electrospray ionization (DESI)   总被引:3,自引:2,他引:1  
The internal energy distributions of typical ions generated by desorption electrospray ionization (DESI) were measured using the "survival yield" method, and compared with corresponding data for electrospray ionization (ESI) and electrosonic spray ionization (ESSI). The results show that the three ionization methods produce populations of ions having internal energy distributions of similar shapes and mean values (1.7-1.9 eV) suggesting similar phenomena, at least in the later stages of the process leading from solvated droplets to gas-phase ions. These data on energetics are consistent with the view that DESI involves "droplet pick-up" (liquid-liquid extraction) followed by ESI-like desolvation and gas-phase ion formation. The effects of various experimental parameters on the degree of fragmentation of p-methoxy-benzylpyridinium ions were compared between DESI and ESSI. The results show similar trends in the survival yields as a function of the nebulizing gas pressure, solvent flow rate, and distance from the sprayer tip to the MS inlet. These observations are consistent with the mechanism noted above and they also enable the user to exercise control over the energetics of the DESI ionization process, through manipulation of external and internal ion source parameters.  相似文献   

13.
Desorption electrospray ionisation (DESI) and neutral desorption/extractive electrospray ionisation (EESI) have been coupled to a hybrid quadrupole travelling-wave (T-Wave)-based ion mobility time-of-flight mass spectrometer for the direct accurate mass analysis of active ingredients formulated into pharmaceutical samples. The collision cross-section measurements of polyethylene glycol (PEG) excipients detected in one formulation were estimated and compared with published data. These estimated collision cross-sections of the PEG species showed good agreement with published data.  相似文献   

14.
Desorption electrospray ionization (DESI) mass spectrometry has been implemented on a commercial ion‐trap mass spectrometer and used to optimize mass spectrometric conditions for DNA nucleobases: adenine, cytosine, thymine, and guanine. Experimental parameters including spray voltage, distance between mass spectrometer inlet and the sampled spot, and nebulizing gas inlet pressure were optimized. Cluster ions including some magic number clusters of nucleobases were observed for the first time using DESI mass spectrometry. The formation of the cluster species was found to vary with the nucleobases, acidification of the spray solvent, and the deposited sample amount. All the experimental results can be explained well using a liquid film model based on the two‐step droplet pick‐up mechanism. It is further suggested that solubility of the analytes in the spray solvent is an important factor to consider for their studies by using DESI. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
We report the first coupling of a desorption electrospray ionization (DESI) ion source to Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR-MS) for high-resolution protein analysis. The DESI FT-ICR-MS source design is described in detail along with preliminary data obtained on peptides and proteins ranging from 1 to 5.7 kDa.  相似文献   

16.
The direct quantitation of active ingredients in solid pharmaceutical tablets by desorption electrospray ionization mass spectrometry (DESI MS) is complicated by the dependence of the DESI signal on variables such as spray angles and distances, morphological sample properties, and the difficulty of properly incorporating an internal standard. Here, a DESI MS method for the direct quantitative screening of widely counterfeited antimalarial tablets containing artesunate is presented. This method is based on reactive DESI, where analyte desorption and ionization occur by the formation of noncovalent complexes between alkylamine molecules in the DESI spray solution and artesunate molecules exposed on the sample surface in the open air. For quantitation purposes, the internal standard d4-artesunic acid was synthesized by esterification of d4-succinic anhydride and dihydroartemisinin, and homogeneously dispersed on the tablet surface via a controlled deposition procedure. The analyte-to-internal standard signal intensity ratio was observed to be largely independent of all DESI variables, only showing dependence on tablet hardness. Analysis of artesunate tablet standards prepared with known amounts of the active ingredient in the 0.02 to 0.32 mg artesunate mg(-1) tablet range resulted in a calibration curve with good linearity (r = 0.9985). Application of this method to the direct quantitation of genuine artesunate tablets from Vietnam showed a 6% (n = 4) precision and 94% accuracy after the spectral data were corrected for tablet hardness.  相似文献   

17.
Redox changes occur in some circumstances when organic compounds are analyzed by desorption electrospray ionization mass spectrometry (DESI-MS). However, these processes are limited in scope and the data presented here suggest that there are only limited analogies between the redox behavior in DESI and the well-known solution-phase electrochemical processes in standard electrospray ionization (ESI). Positive and negative ion modes were both investigated and there is a striking asymmetry between the incidence of oxidation and of reduction. Although in negative ion mode DESI experiments, some aromatic compounds were ionized as odd-electron anion radicals, examples of full reduction were not found. By contrast, oxidation in the form of oxygen atom addition (or multiple oxygen atom additions) was observed for several different analytes. These oxidation reactions point to chemically rather than electrochemically controlled processes. Data is presented which suggests that oxidation is predominantly caused by reaction with discharge-created gas-phase radicals. The fact that common reducing agents and known antioxidants such as ascorbic acid are not modified, while a saturated organic acid like stearic acid is oxidized in DESI, indicates that the usual electrochemical redox reactions are not significant but that redox chemistry can be induced under special experimental conditions.  相似文献   

18.
Reactive desorption electrospray ionization (reactive DESI) is demonstrated to be a rapid and sensitive method for the direct detection of alkyl methylphosphonic acids, the hydrolysis products and metabolites of the chemical warfare (CW) agents VX (S-2-diisopropylaminoethyl-O-ethyl methylphosphonothiolate) and GB (sarin, isopropylmethyl phosphonofluoridate). Rapid and sensitive detection of these compounds is readily achieved by performing DESI from a solid surface; detection specificity is enhanced by implementation of a heterogeneous ion/molecule reaction using boric acid in the spray solvent. The reagent ion H(2)BO(3) (-) generated in the spray readily reacts with condensed-phase alkyl MPA to form anionic adducts. The specificity of this chemical reaction, together with the characteristic fragmentation patterns of the reaction products, supplies a highly discriminatory detection method for methylphosphonic acid (MPA), ethylphosphonic acid (EMPA) and isopropyl methylphosphonic acid (IMPA) in complex matrices.  相似文献   

19.
A new mode of operation for desorption electrospray ionization (DESI) analysis of liquids or solid residues from evaporated solvents is presented. Unlike traditional DESI, the electrospray is not deflected off of a surface but instead is transmitted through a sampling mesh at a 0° angle between the electrospray tip, sample mesh, and capillary inlet of a mass spectrometer. In this configuration, deposited samples can be analyzed rapidly without rigorous optimization of spray distances or angles and without the preparation time associated with solvent evaporation. The new transmission mode desorption electrospray ionization (TM-DESI) technique is not applicable to bulk materials, but instead is a method designed to simplify the sample preparation process for liquid samples and sample extracts. The technique can reduce analysis time to seconds while consuming only microliters of sample. The results presented summarize the optimization of the technique, highlight key figures of merit for several model compounds, and illustrate potential applications to high throughput screening of liquid mixtures in both extraction solvents and biological matrices.  相似文献   

20.
Reactive desorption electrospray ionization (DESI), an ambient technique, has been explored as a tool for the development of a fast screening approach for supramolecular complexes capitalizing on the specificity of mass spectrometric detection. A library of twelve potential guests for inclusion by a β‐cyclodextrin host was initially screened via DESI using a spray solution incorporating the host directed toward an array of deposited guests. The steroid nortestosterone was used to verify the applicability of reactive DESI for complexation experiments with β‐cyclodextrin. Results from the DESI experiment and results from an analogous electrospray ionization (ESI) mass spectral screen were compared with solution‐phase data obtained by nuclear magnetic resonance (NMR) spectroscopy. The complexes detected using DESI were identical to those determined using NMR, validating the applicability of the technique to supramolecular applications, but the ESI data exhibited significant disparities, predominantly due to the interference of nonspecific artifacts. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   