相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A procedure has been developed for the automated determination of aflatoxin M1 in decreamed milk, by using on-line dialysis and subsequent trace enrichment on a reverse phase column. After foreflush to the analytical column the determination is performed with fluorescence detection. Fully automated analysis within 10 min is thus possible with reproducible dialysis recoveries above 50% (CV is 3.3%, n = 20) and detection levels of 50 ng/kg.  相似文献   

2.
Sample pretreatment has often been the rate limiting step in analyses by HPLC. Multicolumn or column switching techniques now available have made efficient automated cleanup procedures possible, with high sample throughput and analytical precision.  相似文献   

3.
A high-performance liquid chromatographic method for the determination of the main phenytoin metabolite, hydroxyphenytoin, in the urine of epileptic patients is described. The use of an automated column-switching technique greatly simplifies the pretreatment steps. Thereby, both time and chemicals are saved. The possibility of error arising during the several pretreatment steps is considerably reduced. Following acid hydrolysis of the hydroxyphenytoin glucuronic acid conjugate the sample is diluted with water and after centrifugation is injected onto the pre-column. After washing for a short time with water, the substances which were absorbed on the head of the pre-column were backflushed with water--acetonitrile as eluent onto the analytical column. Separation is achieved by gradient elution using an ODS reversed-phase column with a particle size of 5 microns.  相似文献   

4.
Both D- and L-serine in rat brain microdialysis sample were simultaneously determined by pre-column fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), separation of the derivatives on ODS column, TSKgel ODS-80TsQA, followed by Pirkle type chiral columns, Sumichiral OA-2500 (S), which gave a sufficient enantiomeric separation of NBD-D-serine and NBD-L-serine, and fluorimetric detection at a wavelength of 540 nm with an excitation wavelength of 470 nm. The peaks of NBD-D-serine and NBD-L-serine in the rat brain microdialysis sample were clearly found, and the validation study showed satisfactory results; the precision and accuracy were within 5.14 and 109%, respectively. Using the proposed HPLC method, the time-course profile of D-serine concentration in rat prefrontal cortex following intraperitoneal administration of D-serine was investigated. As a consequence, D-serine appeared to be rapidly distributed in the brain, and then decreased gradually with time in the extracellular fluid of the rat prefrontal cortex. The proposed HPLC method will be useful for in vivo studies on D-serine, which acts as a coagonist for N-methyl-D-aspartate receptor, to the extracellular fluid of rat brain.  相似文献   

5.
Summary A new high performance liquid chromatographic method was developed using a column-switching technique for the simultaneous determination of cephalexin, cefuroxime, cefoxitin and cephaloridine in plasma. The plasma samples were injected onto a precolumn packed with Corasil RP C18 (37–50 m) after simple dilution with an internal standard solution in 0.01 M acetate buffer (pH 3.5). Polar plasma components were washed out using 0.01 M acetate buffer (pH 3.5). After valve switching, the concentrated drugs were desorbed in back-flush mode and separated on a Partisil ODS-3 column using acetonitrile in 0.02 M acetate buffer (pH 4.3) (1585, v/v) as the mobile phase. The method showed excellent precision with good sensitivity and speed with a detection limit of 0.5 g/ml. The total analysis time per sample was less than 25 min, and the mean coefficients of variation for intra- and inter-assay were both less than 4.9 %.This method has been successfully applied to plasma from rats after subcutaneous injection of cefuroxime.  相似文献   

6.
A method for determining cis-diamminedichloroplatinum(II) (CDDP), an anticancer drug, in plasma and urine by HPLC with UV detection and column-switching has been developed. Typical conditions were as follows. An apparatus was composed of two columns, two pumps, a UV detector, a sample injector with a 100 microL loop, a switching valve, a column oven and a recorder. A Rheodyne model 7125 sample injector was used as the switching valve. A precolumn (4.6 mm ID x 25 cm) was packed with MCI GEL CK10S (a strong cation exchanger), and an analytical column (4.6 mm ID x 5 cm) was packed with MCI GEL CDR10 (a strong anion exchanger). Both columns were connected in series via the switching valve. The CDDP-containing fraction of the effluent from the precolumn was loaded to the analytical column by column-switching and the effluent from the analytical column was monitored at 210 nm. An eluent of 0.3 M sodium dihydrogen phosphate was pumped at a flow rate of 1 mL/min and the columns were maintained at 40 degrees C. CDDP was eluted at about 11 min and the identity of the peak of CDDP on the chromatogram was confirmed by its 3-dimensional chromatogram and analysis of platinum in the column effluent. Under the conditions described above, a linear relationship was obtained between peak height and concentration of CDDP up to 100 microM. Correlation efficients were 0.998 for plasma and 0.999 for urine. The detection limit was 0.1 microM for CDDP in both plasma and urine (S/N = 3,0.005 AUFS). The reproducibility was within 3% for 10 determinations.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
Analyte derivatization is advantageous for the analysis of malondialdehyde (MDA) as a biomarker of oxidative stress in biological samples. Conventionally, however, derivatization is time consuming, error-prone and has limited options for automation. We have addressed these challenges for the solid phase analytical derivatization of MDA from small volume tissue homogenate samples. A manual derivatization method was first developed using Amberlite XAD-2 (12 mg) as the solid phase. Subsequently an automated column switching process was developed that provided simultaneous derivatization and extraction of the MDA-DH hydrazone product on a cartridge packed with XAD-2, followed by quantitative elution of the product to an analytical LC column (Waters NovoPak C18, 3.9 x 150 mm). The LOD was 0.02 microg/mL and recovery was quantitative. The method was linear (r(2) >0.999) with precision < 5% from the LOQ (0.06 microg/mL) to at least 35 microg/mL. The method was successfully applied to the analysis of small volume (30 microL) mouse tissue homogenate samples. Endogenous levels of MDA in the tissues ranged from 20 to 40 nmol/g tissue (ca. 0.1-0.2 microg/mL homogenate). Compared to conventional MDA analyses, the current method has advantages in automation, selectivity, precision and sensitivity for analysis from very small sample volumes.  相似文献   

8.
A one-step sample preparation by electro-deposition for total-reflection X-ray fluorescence (TXRF) analysis has been developed using a common three-electrode arrangement with a rotating disc as the working electrode. Several elements such as Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Cd, Pb, As and U have been determined simultaneously in saline matrix. A special electrode tip has been constructed as a holder for the TXRF sample carrier, which consists of polished glassy carbon. The influence of parameters such as time, pH value, and trace element concentration on the deposition yield has been examined for 14 elements. From repeatability studies, the uncertainty in deposition yields at the 95% confidence level has been found to be less than 20% for most of these elements. Typical detection limits range from 5 to 20 ng/l under the experimental conditions applied here. By an appropriate choice of the reference element and by calculation of yield factors, reliable quantification can be achieved directly by internal standardization. First results obtained for the standard reference material CRM 505 are presented.  相似文献   

9.
10.
Summary A method is described for the determination of deoxynivalenol (DON) in maize and corn silage with a detection limit by UV of 0.2 ppm after a simple separation by means of connected reversed-phase columns.  相似文献   

11.
Kynurenic acid (KYNA), an endogenous antagonist of ionotropic glutamate and α7 nicotinic receptors, was fluorometrically determined by column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. The HPLC system consists of two octadecyl silica (ODS) columns, both of which are connected with an anion-exchange column (trapping column). Following sample injection onto the HPLC column, KYNA was separated on the first ODS column with a mobile phase of H2O/acetonitrile (95/5) containing 0.1% acetic acid. The peak fraction of KYNA was trapped on the anion-exchange column by changing the position of a six-port valve and then introduced into the second ODS column. Subsequently, KYNA was detected fluorometrically as a fluorescence complex formed with zinc ion which was pumped constantly. Instrumental limit of detection was approximately 0.16 nM, which corresponded to 8.0 fmol (per 50 μl injection, signal to noise ratio 3), and the limit of quantification was 0.53 nM (signal to noise ratio 10). Intra- and inter-day relative standard deviations were 1.1-3.9% (n = 3) and 3.0-5.3% (n = 3), respectively. The peak of KYNA in rat plasma was clearly detected by the proposed column-switching HPLC system after a facile pretreatment procedure. Intra- and inter-day relative mean errors were −1.6-1.4% (n = 3) and −2.4 to −0.4% (n = 3), respectively, with a satisfactory precision (within 5.0%). A calibration curve for the determination of KYNA showed a good linearity (r2 > 0.999) in the range of 25-200 nM. The KYNA concentrations in the plasma of male Sprague-Dawley rats (8-week-old) were 44 ± 5.5 nM (mean ± S.E., n = 5). In ketamine-treated rats, which are animal models of schizophrenia, the plasma KYNA concentrations were significantly increased compared with those in the control rats (p < 0.05).  相似文献   

12.
Summary A simple, fast, fully automated method for plasma serotonin determination is described. Full automation is obtained by coupling two devices: a sample processing station and a solid-phase autosampler. The sample processing station dilutes the plasma sample and is then connected, on-stream, with the solid-phase autosampler. It firstly fills a loop with all the solvents necessary for the sample clean-up, then, inverting the flow, pumps these solvents through the silica-bonded cation-exchange disposable extraction cartridge positioned on the autosampler. For the elution, the cartridge is switched on-stream with the HPLC analytical column and serotonin is eluted by the HPLC mobile-phase. The HPLC separation is performed by ion-pairing reversed-phase liquid chromatography. The column effluent is completely reduced by an electrochemical reactor and serotonin is detected in an oxidation-mode by a dual-cell electrochemical detector. The plasma sample is 50 l, the plasma sensitivity is 40 ng/l, the retention time is 6 min and the recovery is 95%. The repeatibility, the normal ranges for platelet-poor and for platelet-rich plasma have been established and correlation with manual HPLC calculated.Presented at the 17th International Symposium on Chromatography, September 25–30, 1988, Vienna, Austria.  相似文献   

13.
提出了电沉积富集制样-X荧光光谱法同时测定水样中痕量Ni、Cd和Pb的方法.方法以平整光滑的高纯铜片为基质,采用电解的方法对待测元素进行电沉积富集,然后用X射线荧光光谱仪进行测定.探讨了沉积电压、溶液pH值、电解质浓度、沉积时间等参数对待测元素电沉积富集的影响.方法精密度(RSD)分 别为Ni 1.6%、Cd 1.2%...  相似文献   

14.
A new rapid, sensitive and validated HPLC method has been developed for the determination of methylxanthines and their metabolites in asthmatic patients. The method was initiated by using spiked urine samples on a silica monolithic column as a novel packing material. The mobile phase consisted of 10 mM potassium dihydrogen phosphate buffer/methanol (87.5:12.5 v/v), at a flow rate 1 mL/min. Detection was set at 274 nm. The LOQ for all the compounds ranged from 14 to 41 ng/mL. Excellent linearity was achieved over the studied range of concentration with correlation coefficients 0.9991–0.9998 (n = 6). The developed method was validated by precision and accuracy with RSD <2.55%. On extraction of the drugs and metabolites from the urine samples high recoveries were achieved ranging from 82.06 to 98.34% w/w on RP18 cartridges and methanol/chloroform (20:80 v/v) as the extraction solvent. This method has advantages over other methods using conventional C18 packings.  相似文献   

15.
This work deals with As determination in marine sediment using ultrasound for sample preparation. It is shown that As can be quantitatively extracted from marine sediment using 20% (v/v) HCl and sonication. The slurry is centrifuged and the analyte is determined in the supernatant by hydride generation atomic absorption spectrometry (HG AAS). A flow injection (FI) system is employed for hydride generation, with 0.5% (m/v) NaBH(4) used as reducdant and a 20% (v/v) HCl used as sample carrier. The limit of quantification is 1.6 microg g(-1) of As, which is based on 800 microl of sample solution and 0.200 g of sample mass in a volume of 50 mL. Certified and non certified marine sediment samples were analyzed; the results were in accordance with the certified or reference values. Speciation analysis by HPLC-ICP-MS showed that As(V) is the only detectable As species present in the supernatant of the centrifuged sample.  相似文献   

16.
The preparation of samples for injection into a high-performance liquid chromatograph from assay mixtures for the determination of cytochrome P-450-dependent testosterone hydroxylation has been substantially facilitated. By replacing the multiple cumbersome extraction steps of the conventional method with a single column extraction the time for sample preparation was reduced from hours to minutes. The new procedure also yields better recoveries for most of the testosterone metabolites than the original protocol. The use of extraction columns for sample preparation allows the simultaneous treatment of a large number of samples or even the automation of the whole assay procedure. The modified procedure is a straightforward, easy-to-perform method that should greatly facilitate the implementation of the testosterone hydroxylation assay for sharply discriminating between many individual cytochrome P-450 species in routine enzyme diagnostics.  相似文献   

17.
18.
A reversed-phase high-performance liquid chromatographic method is described for the quantitative determination of alprazolam in the plasma of geriatric patients in the presence of 4-hydroxyalprazolam, alpha-hydroxyalprazolam, bromazepam, oxazepam, lorazepam, clobazam, desmethylclobazam, diazepam and desmethyldiazepam. The procedure is based on the enrichment of alprazolam on a PRP-1 pre-column, followed by the transfer of the compound in a forflush mode to the analytical column. Alprazolam can be quantified reliably down to a minimum concentration of 1 ng/ml of plasma.  相似文献   

19.
A practical way for reducing contaminants, such as humic acids, and solving column-clogging problem in environmental water analysis with liquid chromatography is proposed. Detection interference by contamination is one of the most important issues of the environmental analyses. Moreover, due to the recent smaller diameter and fine particle size of an analytical column for HPLC system, a column-clogging problem is another practical difficulty as well. We found it possible to solve these problems by employing column-switching HPLC, which consists of a pretreatment column containing surface-modified polymer particles and flow changeover valves for cleaning the remaining matrices in the pretreatment column prior to analysis. This method was successfully applied to actual HPLC-fluorescence detection of bisphenol A. Limit of detection (LOD) in real sample was <0.7 ng/L. Repeatability was around 1.4% and recovery was around 97% or more. A particular pressure increase was not observed in 150 repeated analyses of real river water samples.  相似文献   

20.
A highly sensitive and semi-automated high-performance liquid chromatographic method, utilizing acetonitrile protein precipitation and column-switching, is described for the determination of cyclosporine A in whole blood. Following a rapid manual acetonitrile treatment of the blood samples, the supernatant is loaded automatically onto a 5-micron high-speed protein separation column without any further clean-up operations. The fraction containing cyclosporine A is switched to a 3-micron C18 reversed-phase high-speed column by a microprocessor-controlled column-switching unit for final separation and detection by absorption at 214 nm. Minimal sample handling and efficient separation resulted in a high recovery (75 +/- 3%) of cyclosporine A from blood and a detection limit as low as 2 micrograms/l with a highly reproducible and linear response up to 2500 micrograms/1 using 0.5 ml of sample. A separation cycle including regeneration of the first column is finished in 15 min, and this system was used continuously for ca. 1000 blood samples from heart, liver, kidney, pancreas and bone marrow recipients without change in separation parameters or material replacement. The method described allows accurate and very fast daily routine monitoring of cyclosporine A in large numbers of blood samples from transplant recipients.  相似文献   