首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
A two-infrared laser desorption/ionization method is described. A first laser, which was either an Er:YAG laser or an optical parametric oscillator (OPO), served for ablation/vaporization of small volumes of analyte/matrix sample at fluences below the ion detection threshold for direct matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). A second IR-laser, whose beam intersected the expanding ablation plume at a variable distance and time delay, was used to generate biomolecular ions out of the matrix-assisted laser desorption (MALD) plume. Either one of the two above lasers or an Er:YSGG laser was used for post-ionization. Glycerol was used as IR-MALDI matrix, and mass spectra of peptides, proteins, as well as nucleic acids, some of which in excess of 10(5) u in molecular weight, were recorded with a time-of-flight mass spectrometer. A mass spectrum of cytochrome c from a water ice matrix is also presented. The MALD plume expansion was investigated by varying the position of the post-ionization laser beam above the glycerol sample surface and its delay time relative to the desorption laser. Comparison between the OPO (pulse duration, tau(L) = 6 ns) and the Er:YAG laser (tau(L) approximately 120 ns) as primary excitation laser demonstrates a significant effect of the laser pulse duration on the MALD process.  相似文献   

2.
An all-optical mass spectrometric system is presented which combines the advantages of picosecond-laser desorption and post-ionization with the high performance of a time-of-flight mass-spectrometer. System studies show directly that the ionization process is saturated at focal power densities of about 1012W/cm2. The saturated ionization is used to quantificate the amount of desorbed particles. Typical desorption rates far below one single monolayer per laser pulse could been achieved.  相似文献   

3.
We report the implementation of an infrared laser onto our previously reported matrix-assisted laser desorption electrospray ionization (MALDESI) source with ESI post-ionization yielding multiply charged peptides and proteins. Infrared (IR)-MALDESI is demonstrated for atmospheric pressure desorption and ionization of biological molecules ranging in molecular weight from 1.2 to 17 kDa. High resolving power, high mass accuracy single-acquisition Fourier transform ion cyclotron resonance (FT-ICR) mass spectra were generated from liquid- and solid-state peptide and protein samples by desorption with an infrared laser (2.94 μm) followed by ESI post-ionization. Intact and top-down analysis of equine myoglobin (17 kDa) desorbed from the solid state with ESI post-ionization demonstrates the sequencing capabilities using IR-MALDESI coupled to FT-ICR mass spectrometry. Carbohydrates and lipids were detected through direct analysis of milk and egg yolk using both UV- and IR-MALDESI with minimal sample preparation. Three of the four classes of biological macromolecules (proteins, carbohydrates, and lipids) have been ionized and detected using MALDESI with minimal sample preparation. Sequencing of O-linked glycans, cleaved from mucin using reductive β-elimination chemistry, is also demonstrated.  相似文献   

4.
A new method of electrospray-assisted laser desorption/ionization (ELDI) mass spectrometry, which combines laser desorption with post-ionization by electrospray, was applied to rapid analysis of solid materials under ambient conditions. Analytes were desorbed from solid metallic and insulating substrata using a pulsed nitrogen laser. Post-ionization produced high-quality mass spectra characteristic of electrospray, including protein multiple charging. For the first time, mass spectra of intact proteins were obtained using laser desorption without adding a matrix. Bovine cytochrome c and an illicit drug containing methaqualone were chosen in this study to demonstrate the applicability of ELDI to the analysis of proteins and synthetic organic compounds.  相似文献   

5.
Liu J  Zhang C  Sun J  Luo H 《The Analyst》2012,137(8):1764-1767
We describe complexation reactions of insulin and other proteins with metal ions generated from the substrate surface by laser irradiation in laser desorption spray post-ionization mass spectrometry (LDSPI-MS). This particular type of complexation reaction in LDSPI-MS was investigated for the first time, which indicated that the mechanistic process of LDSPI-MS might be much more complicated than that proposed before for similar methods.  相似文献   

6.
Amphiphilic lipids and hydrophobic proteins are vaporized at atmospheric pressure using nonresonant 70 femtosecond (fs) laser pulses followed by electrospray post-ionization prior to being transferred into a time-of-flight mass spectrometer for mass analysis. Measurements of molecules on metal and transparent dielectric surfaces indicate that vaporization occurs through a nonthermal mechanism. The molecules analyzed include the lipids 1-monooleoyl-rac-glycerol, 1,2-dihexanoyl-sn-glycero-3-phosphocholine, 1,2-dimyristoyl-sn-glycero-3-phosphocholine, and the hydrophobic proteins gramicidin A, B, and C. Vaporization of lipids from blood and milk are also presented to demonstrate that lipids in complex systems can be transferred intact into the gas phase for mass analysis.  相似文献   

7.
A systematic mass spectrometric study of two of the most common analgesic drugs, paracetamol and ibuprofen, is reported. The drugs were studied by means of secondary ion mass spectrometry (SIMS) and secondary neutral mass spectrometry (SNMS) using laser post-ionization (LPI) both in pure samples and in a two-component mixture. Ion suppression within the two-component system observed in SIMS mode is ameliorated using LPI under room temperature analysis. However, suppression effects are apparent in LPI mode on performing the analysis at cryogenic temperatures, which we attribute to changes in the desorption characteristics of sputtered molecules, which influences the subsequent post-ionization efficiency. This suggests different mechanisms of ion suppression in SIMS and LPI modes.
Figure
?  相似文献   

8.
The study of the key parameters impacted surface‐assisted laser desorption/ionization‐mass spectrometry is of broad interest. In previous studies, it has been shown that surface‐assisted laser desorption/ionization‐mass spectrometry is a complex process depending on multiple factors. In the presented study, we showed that neither porosity, light absorbance nor surface hydrophobicity alone influence the enhancement phenomena observed from the hybrid metal‐semiconductor complexes versus individual targets, but small changes in the analyte attaching to the target significantly affect laser desorption ionization‐efficiency. By means of Raman spectroscopy and scanning electron microscopy, it was revealed that the formation of an amorphous analyte layer after drying on a solid substrate was essential for the enhanced laser desorption ionization‐signal observed from the hybrid metal‐semiconductor targets, and the crystallization properties of the analyte appeared as a function of the substrate. Obtained results were used for the screening of regular and lactose‐free milk samples through the hybrid metal‐semiconductor target. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A new system incorporating a multi-turn time-of-flight secondary ion/sputtered neutral mass spectrometer (TOF-SIMS/SNMS) with laser post-ionization was designed and constructed. This system consists of a gallium focused ion beam, femtosecond (fs) laser for post-ionization, and multi-turn TOF mass spectrometer. When laser post-ionization was used, the secondary ion signal strengths for several metals increased by up to 650 times, and were greater than the values obtained in conventional TOF-SIMS experiments. Use of the multi-turn mass spectrometer resulted in an increase in mass resolving power with increase in the total TOF. The mass resolving power reached to 23,000 after 800 multi-turn cycles, corresponding to a flight path length of 1040 m. These results indicated that this system is very effective for the analysis of valuable materials such as space samples with high sensitivity, high mass resolving power, and high lateral resolution.   相似文献   

10.
Time-dependent quantum mechanical calculations have been carried out for the photon- and electron-stimulated desorption of ammonia from metal or semiconductor surfaces. The desorption is facilitated by a short-lived complex which excites the N---H3 inversion mode. The desorption yield and its isotope effect have been obtained from a wave packet on two-dimensional empirical potential energy surfaces. The translational and vibrational distributions of the desorbed ammonia are also calculated. The desorption mechanism includes both direct and predesorption, but the latter predominates. It is shown that the quantum desorption dynamics is much more complex than the simple MGR model.  相似文献   

11.
We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements.  相似文献   

12.
Micro-particles containing actinides are of interest for risk assessments of contaminated areas, nuclear forensic analyses, and IAEA as well as Euratom safeguards programs. For their analysis, secondary ion mass spectrometry (SIMS) has been established as the state-of-the-art standard technique. In the case of actinide mixtures within the particles, however, SIMS suffers from isobaric interferences (e.g., 238U/238Pu, 241Am/241Pu). This can be eliminated by applying resonance ionization mass spectrometry which is based on stepwise resonant excitation and ionization of atoms with laser light, followed by mass spectrometric detection of the produced ions, combining high elemental selectivity with the analysis of isotopic compositions. This paper describes the instrumental modifications for coupling a commercial time-of-flight (TOF)-SIMS apparatus with three-step resonant post-ionization of the sputtered neutrals using a high-repetition-rate (kHz) Nd:YAG laser pumped tunable titanium:sapphire laser system. Spatially resolved ion images obtained from actinide-containing particles in TOF-SIMS mode demonstrate the capability for isotopic and spatial resolution. Results from three-step resonant post-ionization of bulk Gd and Pu samples successfully demonstrate the high elemental selectivity of this process.  相似文献   

13.
The increased popularity of microfabricated devices formed from plastics such as poly(methylmethacrylate) (PMMA) will benefit from approaches adding (bio)chemical functionality to such surfaces. Here, various proteases and nucleases have been covalently immobilized to PMMA surfaces and shown to retain their enzymatic activity as monitored by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Immobilized enzymes yield structural information at a level equivalent to or exceeding that obtained from conventional homogeneous solution-based approaches. Such an approach could be used to expand the functionality of polymer-based microfabricated devices for biological mass spectrometry.  相似文献   

14.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

15.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

16.
As an indication of damage induced by hot electrons in an organic electronic material, the desorption of F- ions from a thin perfluorinated copper phthalocyanide film on SiO2 under low-energy (0-25 eV) electron impact has been recorded mass spectrometrically. Yields and damage cross sections are very low. No strong features due to negative ion resonances are found in the electron energy dependence of the desorption yield; rather the yield function rises from a threshold at about 5-6 eV continuously (with some weak structure) throughout the measured range. We discuss these findings in terms of the electronic structure of the film, as well as parameters influencing the relevant bond breaking process. We emphasize the strong influence of energy redistribution, which quenches normally long-lived negative ion resonances and selects localized and strongly repulsive excitations, as often observed in electronically induced bond breaking at surfaces. The improved understanding should be helpful in the selection of low-damage materials for organic semiconductor devices and for selection of operation parameters.  相似文献   

17.
本文总结了多种构筑硅纳米结构的方法, 综述了近年来利用硅纳米结构提高表面辅助激光解吸/电离质谱(SALDI-MS)性能的研究工作, 展望了利用功能化的硅纳米结构表面进一步提高激光解吸/电离(LDI)效率的前景.  相似文献   

18.
We investigated the thermal mechanism involved in laser desorption/ionization (LDI) of thermally labile molecules from the flat surfaces of amorphous Si (a-Si) and crystalline Si (c-Si). a-Si was selected for this study because of its thermal property, such as low thermal conductivity; thus, it was predicted to be highly susceptible to laser-induced surface heating. By virtue of lack of surface nanostructures, the flat surfaces offer a simple model system to focus on the thermal mechanism, avoiding other effects, including possible non-thermal contributions that can arise from the physical existence of surface nanostructures. For the energetics study, the internal energies of substituted benzylpyridinium ions produced by LDI on the bare and coated surfaces of a-Si and c-Si were obtained using the survival yield method. The results, including LDI thresholds, ion yields, and internal energies all suggested that the LDI mechanism would be indeed thermal, which is most likely promoted by thermal desorption caused by laser-induced surface heating. In addition, the LDI process driven by laser-induced thermal desorption (LITD) was also found to be capable of depositing an excessive internal energy in resulting LDI ions, which underwent a dissociation. It exhibited the essentially same features as in postsource decay (PSD) in MALDI-TOF/TOF mass spectrometry. We report that the LDI process by LITD offers not only a way of intact ionization but also a facile means for PSD of peptide ions, which this work demonstrates is well suited to peptide sequencing using TOF/TOF mass spectrometry.  相似文献   

19.
The use of mass spectrometry (MS) to acquire molecular images of biological tissues and other substrates has developed into an indispensable analytical tool over the past 25 years. Imaging mass spectrometry technologies are widely used today to study the in situ spatial distributions for a variety of analytes. Early MS images were acquired using secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Researchers have also designed and developed other ionization techniques in recent years to probe surfaces and generate MS images, including desorption electrospray ionization (DESI), nanoDESI, laser ablation electrospray ionization, and infrared matrix-assisted laser desorption electrospray ionization. Investigators now have a plethora of ionization techniques to select from when performing imaging mass spectrometry experiments. This brief perspective will highlight the utility and relative figures of merit of these techniques within the context of their use in imaging mass spectrometry.  相似文献   

20.
Infrared soft laser desorption/ionization was performed using a 2.94 µm Er : YAG laser and a commercial reflectron time-of-flight mass spectrometer. The instrument was modified so that a 337 nm nitrogen laser could be used concurrently with the IR laser to interrogate samples. Matrix-assisted laser desorption/ionization (MALDI), laser desorption/ionization and desorption/ionization on silicon with UV and IR lasers were compared. Various target materials were tested for IR soft desorption ionization, including stainless steel, aluminum, copper, silicon, porous silicon and polyethylene. Silicon surfaces gave the best performance in terms of signal level and low-mass interference. The internal energy resultant of the desorption/ionization was assessed using the easily fragmented vitamin B12 molecule. IR ionization produced more analyte fragmentation than UV-MALDI analysis. Fragmentation from matrix-free IR desorption from silicon was comparable to that from IR-MALDI. The results are interpreted as soft laser desorption and ionization resulting from the absorption of the IR laser energy by the analyte and associated solvent molecules. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号