首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
The European Union banned the use of anabolic steroids for cattle fattening in 1988. Analytical techniques able to detect trace amounts of the parent drugs and their metabolites are mandatory for the control of abuse. Stanozolol (Stan) is an anabolic steroid that is often found in injection sites and cocktails. However, it has never been detected in tissues (kidney fat, meat) or excreta (urine, faeces) taken during regulatory inspection. The difference between the structure of Stan and the other steroids (a pyrazole ring fused to the androstane ring system) is probably the cause of this phenomenon. In the multi-laboratory study described here, veal calves were treated with intramuscular doses of Stan. In the excreta of these calves the presence, absence and/or concentration of Stan and of its major metabolites 16 beta-hydroxystanozolol and 3'-hydroxystanozolol were determined. For the determination of these analytes the different laboratories used different extraction and clean-up procedures and also evaluated different analytical techniques such as GC-MS (negative chemical ionization) and LC-MS-MS. The aim of this investigation was to explore which analyte should be validated for veterinary inspection purposes.  相似文献   

2.
Triple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences. Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10 ng mL(-1) in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3'-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL. Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, however QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite.  相似文献   

3.
An improved radioreceptor assay (RRA) is used for the screening of urine samples from cattle for the presence of exogenous oestrogenic anabolic compounds, e.g., stilbenes and zeranol. The method includes extraction of the hormones from urine samples with simultaneous purification using reversed-phase C18 cartridges. High-performance liquid chromatography is used to isolate the anabolics from the naturally occurring oestrogens. Fractions containing the stilbenes and zeranol are collected and subsequently analysed using the RRA with the oestrogen receptor, isolated from immature calf uteri, as a binder and tritiated 17 beta-oestradiol as a tracer. Urine samples from untreated calves and cows and samples from calves treated with zeranol-trenbolon acetate, dienoestrol or hexoestrol or samples containing diethylstilboestrol were analysed with this RRA method. Sensitivity, specificity and predictive values were calculated at different classification levels (0.4, 0.5, 0.6 and 1.0 ng/ml 'apparent' oestradiol in urine). An optimum sensitivity (89%) with a maximum specificity (95%) was reached at a classification level of 0.6 ng/ml. At this level the detection limits in urine samples are 0.5 ng/ml for hexoestrol, 0.6 ng/ml for diethylstilboestrol, 0.9 ng/ml for dienoestrol and 5.0 ng/ml for zeranol.  相似文献   

4.
Anabolic steroids are banned in food producing livestock in Europe. Efficient methods based on mass spectrometry detection have been developed to ensure the control of such veterinary drug residues. Nevertheless, the use of "cocktails" composed of mixtures of low amounts of several substances as well as the synthesis of new compounds of unknown structure prevent efficient prevention. New analytical tools able to detect such abuse are today mandatory. In this context, metabolomics may represent new emerging strategies for investigating the global physiological effects associated to a family of substances and therefore, to suspect the administration of steroids. The purpose of the present study was to set up, assess and compare two complementary mass spectrometry-based metabolomic strategies as new tools to screen for steroid abuse in cattle and demonstrate the feasibility of such approaches. The protocols were developed in two European laboratories in charge of residues analysis in the field of food safety. Apart from sample preparation, the global process was different in both laboratories from LC-HRMS fingerprinting to multivariate data analysis through data processing and involved both LC-Orbitrap-XCMS and UPLC-ToF-MS-MetAlign strategies. The reproducibility of both sample preparation and MS measurements were assessed in order to guarantee that any differences in the acquired fingerprints were not caused by analytical variability but reflect metabolome modifications upon steroids administration. The protocols were then applied to urine samples collected on a large group of animals consisting of 12 control calves and 12 calves administrated with a mixture of 17β-estradiol 3-benzoate and 17β-nandrolone laureate esters according to a protocol reflecting likely illegal practices. The modifications in urine profiles as indicators of steroid administration have been evaluated in this context and proved the suitability of the approach for discriminating anabolic treated animals from control ones. Such an approach may therefore open a new way for the screening of anabolic steroid administration through targeted monitoring of relevant biomarkers highlighted as a result of the metabolomics study.  相似文献   

5.
For many years, EC regulations have prohibited the use of anabolic agents in food-producing animals. Multiple screening methods have been published, but some lack specificity and some are difficult to apply when screening for unknowns in surveillance programmes. This paper presents a new and powerful technique, combining multiresidue immunoaffinity chromatography and GC-MS, for the simultaneous identification and semi-quantification of various anabolic steroids in urine and faeces samples of bovine origin. It should reduce the cost, time and effort of screening by limiting the number of tedious clean-up steps and analyses required. A preliminary extraction step is applied to the individual biological specimens: solid-phase extraction followed by enzymatic digestion in the case of urine samples and a single liquid extraction step for faeces. This step is followed by a first clean-up step involving both a solid-phase column and a rapid RP-HPLC separation. The individual biological fractions (urine or faeces) are further purified on a multiresidue immunoaffinity chromatographic gel (MIAC-steroids-CER) so as to decrease interferences due mainly to background signals. A final trimethylsilyl derivatization is followed by the analysis of the biological samples by a sensitive and specific GC-MS procedure.  相似文献   

6.
Rapid detection of trace level anabolic steroids in urine is highly desirable to monitor the consumption of performance enhancing anabolic steroids by athletes. The present article describes a novel strategy for identifying the trace anabolic steroids in urine using Leidenfrost phenomenon assisted thermal desorption (LPTD) coupled to dielectric barrier discharge (DBD) ionization mass spectrometry. Using this method the steroid molecules are enriched within a liquid droplet during the thermal desorption process and desorbed all-together at the last moment of droplet evaporation in a short time domain. The desorbed molecules were ionized using a dielectric barrier discharge ion-source in front of the mass spectrometer inlet at open atmosphere. This process facilitates the sensitivity enhancement with several orders of magnitude compared to the thermal desorption at a lower temperature. The limits of detection (LODs) of various steroid molecules were found to be in the range of 0.05–0.1 ng mL−1 for standard solutions and around two orders of magnitude higher for synthetic urine samples. The detection limits of urinary anabolic steroids could be lowered by using a simple and rapid dichloromethane extraction technique. The analytical figures of merit of this technique were evaluated at open atmosphere using suitable internal standards. The technique is simple and rapid for high sensitivity and high throughput screening of anabolic steroids in urine.  相似文献   

7.
Doping control in sport is mandatory to detect and to control the use of prohibited substances. Due to the growing number of targets, the analysis of doping compounds and their metabolites is carried out using established screening methods. However, detection of anabolic steroids with 4,9,11-triene structure in urine is problematic, so it is necessary to improve the methods.We review the state of the art in doping-control analysis of 4,9,11-trien-3-one steroids, providing an overview of the screening and confirmatory methods developed for these analytes in human urine. First, we review chromatographic techniques. We discuss difficulties in the derivatization of those compounds prior to gas chromatography analyses. In recent years, liquid chromatography has been the preferred technique in drug testing in sport, due to the reduced sample pre-treatment, improved limits of detection and comprehensiveness. We also report on advances and limitations of immunochemical techniques for the analysis of this group of substances.  相似文献   

8.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

9.
Nineteen different dietary supplements, ordered through the internet and intercepted by the Belgian pharmaceutical inspection at the post office, were analyzed by means of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the presence of anabolic steroids. After a methanolic extraction the samples were screened for the presence of 49 compounds. This resulted in almost 60% of the samples being suspected of containing one of these 49 anabolic compounds and being subjected to a confirmatory product ion scan. In all of these suspected samples we were able to confirm at least one anabolic steroid with concentrations between 0.01 and 2.5 mg unit(-1) (unit: one capsule or tablet or for liquids: the prescribed dose). The anabolic steroids that was mostly encountered was testosterone (50%) followed by beta-boldenone (25%). These results once more confirm the dubious reputation of over-the-counter dietary supplements.  相似文献   

10.
《Analytical letters》2012,45(7):1313-1322
ABSTRACT

A method to detect three anabolic steroids (boldenone, nandrolone and mesterolone) is presented. The anabolic steroids are isolated from equine plasma and urine by extraction with diethyl ether and C18 Sep-Pak cartridge adsorption, respectively. The extracts obtained were derivatized with trifluoroacetyl anhydride and analyzed by GC/SIM/MS. The selected ion monitoring (SIM) mode was applied to increase the sensitivity and, when possible, the higher m/z ions were selected to improve identification. Stability of derivatives was good and compounds having hydroxy and conjugated ketone groups produced trifluoroacetyl ester derivatives that were also stable. Repeatability of the chromatographic analysis was evaluated on the basis of area repeatability, and the coefficient of variation obtained was lower than 4.4. The detection limit was 1 and 5 ng/ml for all the anabolic steroids studied in equine plasma and urine, respectively.  相似文献   

11.
Factors affecting the sensitivity and selectivity of the determination of diuretics, anabolic steroids, central nervous system stimulants, and narcotics in the analysis of human urine extracts by high-performance liquid chromatography-tandem mass spectrometry with atmospheric pressure electrospray ionization and recording of positive ions were investigated. Mass spectra were obtained for all of the test compounds; the characteristic ions, retention times, detection limits, degree of ionization suppression by the matrix, the extraction of the analytes from human biological fluids were determined for all analytes; the selectivity and specificity of determination were evaluated.  相似文献   

12.
A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flight mass spectrometry (GCoaTOFMS) has been developed in order to acquire accurate full scan MS data to be used to detect designer steroids. The developed method allowed the detection of representative prohibited substances, in addition to steroids, at concentrations of 10 ng/mL for anabolic agents and metabolites, 30 ng/mL for corticosteroids, 500 ng/mL for stimulants and beta-blockers, 250 ng/mL for diuretics, and 200 ng/mL for narcotics. Sample preparation was based on liquid-liquid extraction of hydrolyzed human urine, and the final extract was analyzed as trimethylsilylated derivatives in GCoaTOFMS and underivatized in LCoaTOFMS in positive ion mode. The sensitivity, mass accuracy, advantages and limitations of the developed method are presented.  相似文献   

13.
The illegal use of anabolic steroids in livestock breeding has taken enormous proportions the last few decades. To protect the consumer against possible harmful effects due to the consumption of contaminated meat or meat products, a multiresidue analysis of anabolic steroids has been developed for muscle tissues and urine. The pretreatment of the meat and urine samples consists of an enzymatic digestion, liquid or solid-phase extraction, and finally high-performance liquid chromatography (HPLC) fractionation. Five fractions or windows are collected, each containing a number of analytes. The residues are derivatized prior to the detection by gas chromatography-mass spectrometry (GC-MS). Both gas chromatographic retention data and mass spectral data are used for identification of nortestosterone, testosterone, estradiol, ethynylestradiol, trenbolone, zeranol, diethylstilbestrol, boldenone, methandienone, methyltestosterone, megestrol acetate, chlormadinone acetate, medroxyprogesterone acetate, chlorotestosterone, progesterone, and chlorotestosterone acetate. The limit of detection varies from matrix to matrix and from analyte to analyte but is, in the most favorable case, on the order of 0.3 ppb (micrograms/kg).  相似文献   

14.
The applicability of in-vial two-phase liquid-phase microextraction (LPME) in porous hollow polypropylene fiber was studied for the sample preparation of unconjugated anabolic steroids in urine. Four different anabolic steroids - metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol - were used as test compounds and methyltestosterone as an internal standard. A standard two-phase LPME method for use with liquid chromatography/mass spectrometry (LC/MS) was set up and the influence of different parameters, including the nature of organic solvent, extraction time, salting-out and temperature, on the LPME process was investigated. Taking advantage of the preliminary studies, a novel two-phase LPME method utilizing simultaneous in-fiber silylation was developed and validated for gas chromatographic/mass spectrometric (GC/MS) analysis of a danazol metabolite in urine. In all, LPME allowed a very straightforward, simple and selective way to prepare urine samples for steroid analysis, being most suitable for hydrophobic steroids. The LPME method with in-fiber derivatization for GC/MS analysis exhibited high sensitivity, repeatability and linearity and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine matrix without any other steps in sample pretreatment.  相似文献   

15.
A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.  相似文献   

16.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

17.
A high-performance liquid chromatographic method for the determination of the free excreted anabolic drug methandienone in pharmacokinetic studies is described. After extraction of the free steroids from urine, separation on reversed-phase columns leads to quantitative determination of this drug down to 5 ng, and to qualitative detection of less than 1 ng amounts. Because the anabolic drugs and their metabolites are eluted later than the other normally excreted constituents this method is also useful for the routine surveillance of anabolic drug abuse in the sports in general.  相似文献   

18.
A stir bar for sorption extraction based on monolithic material (SBSEM) was prepared in this study. The monolithic material was obtained by in situ copolymerization of octyl methacrylate and ethylene dimethacrylate in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of polymerization parameters and the thickness of monolithic materials on the adsorption and desorption efficiencies were investigated, using naphthalene, phenanthrene and fluoranthene as detected solutes. The results show that monolithic material possessed good permeability resulting in fast adsorption and desorption for detected solutes. Spiked seawater samples containing eight polycyclic aromatic hydrocarbons (PAHs) and urine samples containing four anabolic steroids were preliminarily analyzed by using the sorptive bars and liquid desorption followed by high performance liquid chromatography with diode array detection. The results demonstrate that prepared stir bar was suitable for preconcentration of both apolar and polar analytes. The enrichment factors for phenanthrene, anthracene and pyrene were 150, 134 and 189, respectively. The SBSEM shows good batch-to-batch reproducibility and good stability, and can be reused a least 10 times for the extraction of polycyclic aromatic hydrocarbons in seawater.  相似文献   

19.
Within the scope of the European Community member states' residue monitoring plan, illicit administration of anabolic steroids is monitored at slaughterhouse level as well as on living animals. At farm level, urine is one of the target matrices to detect possible abuse of anabolic steroid growth promoters. Optimisation of the routinely applied analysis method resulted in a procedure for which high performance liquid chromatographic (HPLC) fractionation prior to GC-MS(n) analysis was no longer required. Analytical results could be obtained within 1 day and only 5 mL urine was needed to carry out the screening procedure. Using the downscaled methodology, all validation criteria described in the European Commission document 2002/657/EC could be fulfilled, and the minimum required performance limits (MRPLs) established for anabolic steroids in urine, could be achieved. A higher GC-MS technique's specificity was achieved by detecting the steroids using GC-MS3. Nevertheless, it was decided to screen routinely sampled urine with GC-MS2 whereas GC-MS3 was applied to confirm the presence of anabolic steroid residues in suspected sample extracts.  相似文献   

20.
This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid–liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at ?20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r?≥?0.990) over a range of 50–1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n?=?3) and inter-day (n?=?5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N?=?5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号