1.
Microemulsion electrokinetic chromatography (MEEKC) coupled with a diode-array detector was developed for the simultaneous analysis of natural steroidal compounds, withanolides including withaferin A, withacnistin and iochromolide. Optimal resolution was obtained with a microemulsion consisting of 70 mM octane, 800 mM 1-butanol, 100 mM sodium dodecyl sulfate (SDS), and 10 mM phosphate-borate buffer (pH 7) using a fused-silica capillary at 25 kV and 40 degrees C. Since this technique is not compatible with mass spectrometry detection, a capillary electrochromatographic method was developed to separate the investigated withanolides. The effects of mobile phase composition and pH were systematically investigated. Complete separation was obtained with a capillary electrochromatography (CEC) Hypersil C18 bonded silica column (packed length, 25 cmx100 microm ID and 375 microm OD), packed with 3 microm particles. The mobile phase consisted of formic acid-ammonia, pH 8 / acetonitrile (40/60 v/v); the voltage was set at 25 kV and the temperature at 20 degrees C. Under these conditions, resolution of these closely related compounds, including the critical pair withacnistin and iochromolide, was achieved in less than 5 min. The separations by MEEKC and CEC were compared with that obtained by reversed-phase liquid chromatography and showed similar retention order, indicating the analogy of the retention mechanism of these techniques. To further improve specificity and sensitivity, the developed CEC method was interfaced with electrospray ionization mass spectrometry using a Teflon connection between the CEC column and a void fused-silica capillary. Finally, the described methods were applied to the qualitative analysis of withanolides in Iochroma gesnerioides plant extract.  相似文献   

2.
Microemulsion electrokinetic chromatography of proteins.   总被引:2,自引:0,他引:2  
Microemulsion electrokinetic chromatography was used to separate a test mixture of proteins effectively. The separation was carried out in a 42.5 cm (to the detector) x 50 microns I.D. fused-silica capillary using a microemulsion system consisting of 80 mM heptane, 120 mM SDS, 900 mM butanol in 2.5 mM borate buffer, pH 8.5-9.5. Optimum separation conditions were investigated with respect to the running voltage, temperature, pH and the composition of microemulsion. Results were compared with those obtained in micellar electrokinetic chromatography and capillary zone electrophoresis. The examined method is practical and successfully applied to the assay of genetically engineering pharmaceuticals, recombinant human granulocyte macrophage colony stimulating factor injection and recombinant human granulocyte colony stimulating factor injection.  相似文献   

3.
This paper shows the applicability of capillary electrophoresis (CE) coupled to mass spectrometry (MS) for the analysis of acrylamide (AA) in foodstuffs. In order to obtain an ionisable compound amenable to be analysed by CE, acrylamide was derivatised with 2-mercaptobenzoic acid. Spectra in positive and negative modes were studied in order to select the best ionisation mode and multistep tandem mass spectrometry was used to obtain structural information. Maximum signal was observed when negative mode was used and MS/MS and MS3 were selected for quantitation and confirmation, respectively. For the separation, a fused-silica capillary of 80 cm and 50 microm I.D. and 35 mM ammonium formate/ammonia solution at pH 10 as running electrolyte were used. The applicability of field amplified sample injection (FASI) in reversed polarity was evaluated in order to decrease detection limits. The developed FASI-CE-MS/MS method provided a detection limit of 8 ng g(-1) and good linearity (r=0.999) and precision (day-to-day lower than 15%). The method has been applied to the analysis of different representative food products and the results were compared with those obtained by LC-MS/MS.  相似文献   

4.
Capillary electrophoresis (CE) separations are reported for sulfonamides and benzodiazepines in an uncoated fused-silica capillary. The capillary column exit was connected to a liquid junction-ion spray interface combination coupled to an atmospheric pressure ionization (API) triple quadrupole mass spectrometric (MS) system. On-line UV detection occurred 20 cm from the inlet of the capillary and with the API mass spectrometer (CE-API-MS) after the entire length of the capillary (100 cm). The separations were made using volatile buffers composed of ammonium acetate (15-20 mM) with 15-20% of methanol to facilitate ionization under electrospray conditions. This study showed that the major metabolite of flurazepam in man, N-1-hydroxyethylflurazepam, could be detected and characterized in human urine by CE-UV-MS following the administration of a single oral dose of 30 mg of flurazepam dihydrochloride. The presence of additional flurazepam metabolites in human urine was observed by using the system, suggesting that a combination of UV with MS detection should be useful for metabolic studies. In addition to molecular weight determination of compounds, structural information may be obtained by utilizing online tandem mass spectrometry (CE-UV-MS-MS). This was demonstrated for sulfamethazine where the protonated molecule species was transmitted into the collision cell of the tandem triple quadrupole mass spectrometer. Collision-induced dissociation of the protonated sulfamethazine molecule yielded structural information characteristic of the sulfa drug following the on-column injection of 2 pmol of sulfamethazine.  相似文献   

5.
Micellar electrokinetic chromatography (MEKC) was successfully and conveniently applied to the chiral separation with the addition of cyclodextrins (CDs) as chiral selector to the running buffer. Chiral separation depended on the type of CD; in particular, beta-CD was effective for the chiral separation of racemorphan. We investigated the optimal conditions of type and concentration of CD as chiral selector for the routine enantiomeric separation of racemorphan with good reproducibility. The effects of other parameters such as buffer pH and detection wavelength were also investigated to obtain the optimum conditions for the enantiomeric separation of racemorphan. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used for confirmation of racemorphan. The optimal conditions for enantiomeric separation of the racemorphan were as follows: 50 mM borate buffer at pH 9.4 with 50 mM SDS, 10 mM beta-CD and 20% 1-propanol, 57 cm x 50 microns fused-silica capillary column, and UV detection at 192 nm. Based on the developed method, racemorphan in human urine was also separated and determined using solid-phase extraction and MEKC.  相似文献   

6.
Ali I  Aboul-Enein HY 《Electrophoresis》2003,24(12-13):2064-2069
The chiral resolution of baclofen was achieved by capillary electrophoresis using a fused-silica capillary (60 cm x 75 microm ID). The background electrolyte (BGE) was phosphate buffer (pH 7.0, 50 mM)-acetonitrile (95:5 v/v) containing 10 mM beta-cyclodextrin. The applied voltage was 15 kV. The values of alpha and R(s) were 1.06 and 1.00, respectively. The electrophoretic conditions were optimized varying the pH and the ionic strength of the BGE, concentrations of beta-cyclodextrin and acetonitrile and the applied voltage.  相似文献   

7.
The development and validation of an analytical method for the determination of spiramycin I in the presence of its related substances by capillary electrophoresis is shown. The separation, performed in a phosphate buffer (80 mM, pH 7.5) containing 12 mM cetyltrimethylammonium bromide (CTAB) and 20 mM sodium cholate, with a 50 microm ID and 44 cm long fused-silica capillary (36 cm effective length), applying a voltage of 12 kV (l approximately 80 microA), at 25 degrees C, is achieved in 15 min. Good selectivity among spiramycin I and its related substances was obtained. The influence of the buffer pH, and of the CTAB and sodium cholate concentrations was investigated. The method robustness, examined by means of a full-fraction factorial design, shows that it can be used within the limits set for the three parameters that were investigated. The method is linear (r = 0.9992) and precise (day-to-day corrected peak area repeatability, n = 18, relative standard deviation = 1.3%). The limits of detection and quantitation are 7 pg (0.025%) and 22 pg (0.08%), respectively, relative to a 2 mg/mL solution.  相似文献   

8.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

9.
A new method for the identification of oligosaccharides obtained by enzymatic digestion of hyaluronic acid (HA) with bacterial hyaluronidase (HA lyase, E.C. 4.2.2.1, from Streptococcus agalactiae) using online capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS) is presented. A fused-silica capillary coated with polyacrylamide was used with a 40 mM ammonium acetate buffer at pH 9.0 and a separation voltage of +30 kV applied to the inlet. Separation was achieved for oligosaccharides containing 4-16 monomers. The migration behavior follows the chain length of the oligomers, regardless of charge state. However, no linear relationship was found for the relation between mobility and chain length. Using an ion trap mass analyzer, complementary structural information was obtained by MS/MS and MS(n) experiments.  相似文献   

10.
Lin SY  Wang GR  Huang QP  Liu CY 《Electrophoresis》2006,27(21):4257-4265
We introduce a T-type interface and a crossflow nebulizer to find ways to combine CEC with inductively coupled plasma MS (ICP-MS) detection for selenium speciation. For CEC separation, we employed a macrocyclic polyamine-bonded phase capillary as the separation column and a bare fused-silica capillary filled with the make-up liquid (0.05 M HNO3). The effect of nebulizer gas flow rate, make-up liquid flow, type, concentration and pH of the mobile phase on the separation have been studied. Tris buffer of 50 mM at pH 8.50 gave the best performance for selenium speciation. The reproducibility of the retention time indicated that sample injection by electrokinetic and nebulizer gas flow was better than that by self-aspiration alone. The detection limits for selenate, selenite, selenocystine and selenomethionine were found to be 2.40, 3.53, 12.86 and 11.25 ng/mL, respectively. Due to the high sensitivity and element-specific detection, as well as the high selectivity of the bonded phase, quantitative analysis of selenium speciation in urine was also achieved.  相似文献   

11.
A protein-bonded porous-layer open-tubular (PLOT) column has been synthesized and applied to the separation of amino acids by CEC. The porous layer was coated on the capillary inner wall by in situ polymerization of 2-hydroxyethyl methacrylate and 2-vinyl-4,4-dimethylazlactone in the presence of 1-decanol as a porogen inside a fused-silica capillary silanized with gamma-methacryloxypropryltrimethoxysilane. The azlactone functionalities at the surface of the porous polymeric support layer were allowed to react with BSA to yield a protein-bonded PLOT column. This porous layer was characterized by scanning electron microscopy and its thickness was about 1 microm. CEC on this column gave enhanced resolution of three amino acids (histidine, phenylalanine, and tryptophan), and baseline separation was achieved with 20 mM phosphate buffer, pH 8.0.  相似文献   

12.
Nogami C  Sawada H 《Electrophoresis》2005,26(7-8):1406-1411
Capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) was applied to the analysis of polar positional and geometrical anionic isomers. Since the investigated positional and geometrical anionic isomers have different pK(a) values, they could be separated by CE-ESI-MS under simple analytical conditions using a bare fused-silica capillary and volatile ammonium acetate buffer after optimizing buffer pH. Ortho-, meta-, para-hydroxybenzoate positional isomers were completely separated on a fused-silica capillary with 20 mM ammonium acetate buffer at pH 10.0, and cis-, trans-cyclohexane dicarboxylate geometrical isomers could be also separated with 20 mM ammonium acetate buffer at pH 4.0. Several analytical parameters affecting ESI-MS sensitivity were also investigated. It was found that both running buffer pH and sheath liquid pH had significant effects on the selectivity and the sensitivity on CE-ESI-MS analysis while sheath flow rate and other parameters had little influence. Under optimized conditions, linearity, detection limit, and repeatability of the analysis of hydroxybenzoate isomers were examined, and good results were obtained. It was found that the method presented in this paper is a simple, robust, and cost-effective method for simultaneous analysis of positional and geometrical anionic isomers as well as of other small anionic compounds.  相似文献   

13.
Summary A systematic investigation of operational buffer systems, sample preparation and instrument parameters for achieving the best possible performance for determinating an homologous series of N-benzyl-N-alkyl-N,N-dimethylammonium chloride compounds by capillary zone electrophoresis with direct UV detection. The most effective separation was achieved within 3.5 min with the addition of acetonitrile (40%) in a phosphate buffer (20 mM pH 5.2) using a 40 cm fused-silica capillary operating at 25 KV and 20°C. Degassing of all electrolyte solutions and samples was very important. The linearity and repeatability for each compounds were satisfactory. To improve detection limits, on-column sample preconcentration, sample stacking, was investigated achieving a tenfold enrichment factor and quantitation limits about 10−7M.  相似文献   

14.
Lin CC  Liu CY 《Electrophoresis》2004,25(18-19):3216-3223
With 3-trimethoxysilylpropyl chloride as the spacer, a proline-coated capillary column was prepared for the capillary electrochromatographic (CEC) separation of amino acids by in-column derivatization. Nine standard mixtures, including aspartic acid, glutamic acid, valine, phenylalanine, alanine, isoleucine, leucine, tyrosine, and tryptophan, were injected. o-Phthalaldehyde (OPA), OPA/2-mercaptoethanol (2-ME) and OPA/N-acetylcysteine (NAC) in borate buffer were tested as the derivatizing agent. Among them, OPA (50 mM) in borate buffer (pH 9.5, 50 mM) gave the best performance. The formation of isoindole could be detected by UV detection. The sandwich-type injection was carried out in hydrostatic mode (10 cm) with the program R(10 s)S(10 s) R(10 s)W(10 min) with R, S, and W being the reagent, sample, and waiting times. Mesityl oxide, benzyl alcohol, and acetone showed some interaction with the column. A current monitoring method was used instead of the determination of the electroosmotic flow (EOF). The direction of EOF was from anode to cathode even under acidic condition lower than the pI value (6.31) of the bonded group due to some unreacted silanol groups. Some parameters including pH, nature, and concentration of the mobile phase and the effect of organic modifier with regard to the CEC separation were investigated. With the proline-coated column (75 (50) cm x 75 microm ID) the best separation was performed in phosphate buffer (pH 4.00, 100 mM) with an applied voltage of -15 kV. The established method was also compared with those precolumn derivatized prior to the separation with proline-coated column as well as with in-capillary derivatization and separation with a bare fused-silica column.  相似文献   

15.
On-line combination of partial filling capillary electrophoresis and electrospray ionization mass spectrometry was demonstrated for the simultaneous enantioseparation of tramadol and its main phase I metabolites. The partial filling technique was efficient at avoiding MS contamination by the chiral selector. Different experimental factors were investigated, including the chiral selector nature and concentration, plug length as well as the separation temperature. The best enantioseparation of the investigated compounds was achieved with a coated polyvinyl alcohol capillary and a 40 mM ammonium acetate buffer, pH 4.0, adding sulfobutyl ether beta-cyclodextrin (2.5 mg/ml) as the chiral selector. The charged cyclodextrin not only allowed enantioseparation of tramadol and its metabolites, but also improved the selectivity of compounds with the same molecular mass. Finally, CE-electrospray ionisation-MS was successfully applied to the stereoselective analysis of tramadol and its main metabolites in plasma after a simple liquid-liquid extraction.  相似文献   

16.
Aqueous and nonaqueous capillary electrophoresis (NACE) were investigated for separation of venlafaxine, a new second-generation antidepressant, and its three phase I metabolites. Working at basic pH, around the venlafaxine pKa value, was effective in resolving the investigated drugs, but created considerable peak tailing. To overcome electrostatic interactions between analytes and silanol groups, investigations were also carried out at acidic pH. However, despite the addition of up to 50% v/v of organic solvents (e.g., methanol or acetonitrile), complete separation of the studied compounds was not possible. NACE was found to be an appropriate alternative to resolve venlafaxine and its metabolites simultaneously. Using a conventional capillary (fused-silica, 64.5 cm length, 50 microm inner diameter), and a methanol-acetonitrile mixture (20/80 v/v) containing 25 mM ammonium formate and 1 M formic acid, complete resolution of these closely related compounds was performed in less than 3.5 min. Selectivity, efficiency and separation time were greatly affected by the organic solvent composition. As the electric current generated in nonaqueous medium was very low, the electric field was further increased by reducing the capillary length. This allowed a baseline resolution of venlafaxine and its three metabolities in 0.7 min. Selectivity was compared in aqueous and nonaqueous media in relation to the acid-base properties of the analytes as well as to the solvation degree. Finally, the method successfully coupled on-line to mass spectrometry with electrospray ionization interface allowed significant sensitivity enhancement.  相似文献   

17.
Hsieh YL  Chen TH  Liu CP  Liu CY 《Electrophoresis》2005,26(21):4089-4097
A novel column made through the condensation reaction of TiO2 nanoparticles (TiO2 NPs) with silanol groups of the fused-silica capillary is described. EOF measurements under various buffer constitutions were used to monitor the completion of reactions. The results indicated that the EOF was dependent on the interactions between buffers and the bonded TiO2 NPs. With formate/Tris buffer, EOF reversal at pH below 5 and cathodic EOF at pH above 5 were indicated. The pI of the bonded TiO2 NPs was found at approximately ph 5. Only cathodic EOF was illustrated by substituting the mobile phase with either glutamate or phosphate buffer. It was elucidated that both glutamate and phosphate buffer yield a negative charge layer on the surface of TiO2 NPs attributable to the formation of a titanium complex. The CEC performance of the column was tested with angiotensin-type oligopeptides. Some parameters that would affect the retention behavior were investigated. The interactions between the bonded phases and the analytes were explicated by epitomized acid-base functional groups of the oligopepetides and the speciation of the surface oxide in different pH ranges. The average separation efficiencies of 3.1 x 10(4) plates/m is readily achieved with a column of 70 cm (50 cm) x 50 mum ID under an applied voltage of 15 kV, phosphate buffer (pH 6.0, 40 mM), and UV detection at 214 nm.  相似文献   

18.
The development and validation of an optimized capillary electrophoresis method for the determination of metacycline in the presence of its related substances by capillary electrophoresis is shown. The influence of methanol as organic modifier, buffer pH, buffer concentration, capillary length, column temperature, Triton X-100 and methyl-beta-cyclodextrin was investigated. A central composite design was performed in order to optimize the method. The optimal separation conditions were: uncoated fused-silica capillary (39 cm total length, 31 cm effective length, 50 microm ID); as background electrolyte a solution of 160 mM sodium carbonate and 1 mM EDTA (pH 10.35)/methanol (89:13 v/v); temperature, 15 degrees C; voltage, 12 kV. The method showed good selectivity, repeatability, linearity, and sensitivity. The limits of detection and quantitation are 0.024% and 0.06%, respectively, relative to a 2.5 mg/mL solution. Six commercial samples were analyzed quantitatively.  相似文献   

19.
Capillary high-performance liquid chromatography (capillary HPLC), pressure-assisted capillary electrochromatography (pCEC) and capillary electrochromatography (CEC) were performed in the same capillary packed with 5 microm octadecylsilica (C18) as stationary phase. These three separation modes were compared from the viewpoint of peak efficiency and separation selectivity in order to critically evaluate the advantages which CEC may offer compared to capillary HPLC for the solution of practical biomedical problems. The separation of the non-steroidal anti-inflammatory drug etodolac (ET, 1) and its phase I metabolites, 6-hydroxy etodolac (6-OH-ET, 2), 7-hydroxy etodolac (7-OH-ET, 3) and 8-(1'-hydroxyethyl) etodolac (8-OH-ET, 4) was selected as an example. Baseline separation of all compounds was achieved in different modes and conditions. The effect of pure electrophoretic separation mechanism on the overall separation selectivity observed in CEC has been shown. A high electroosmotic flow (EOF) was observed in C18 packed capillary even at pH 2.5 in various buffers. Furthermore, these separations were coupled on-line with electrospray ionisation mass spectrometry (ESI-MS) and the parent drug and its metabolites were identified in urine. For the coupling of CEC with ESI-MS a laboratory-made electrophoretic device was used in order to overcome some technical disadvantages of commercial instrumentation.  相似文献   

20.
A capillary electrophoresis (CE) method has been developed that allows the separation and estimation of primaquine enantiomers using hydroxypropyl-gamma-cyclodextrin (HP-gamma -CD) as a chiral selector. The influence of chemical and instrumental parameters on the separation, such as type and concentration of CD, buffer concentration, buffer pH, applied voltage, capillary temperature, and injection time, were investigated. Good separation of the racemic mixture of primaquine was achieved using a fused-silica capillary (52.5 cm effective length x 50 microm id) and a background electrolyte composed of tris-phosphate buffer solution (50 mM, pH 2.5) containing 15 mM HP-gamma-CD as a chiral selector. The recommended applied voltage, capillary temperature, and injection time were 15 kV, 25 degrees C, and 6 s, respectively. Within-day and interday reproducibility of peak area and migration time gave relative standard deviation values ranging from 1.05-3.30%. Good recoveries (range of 96.8-104.9%) were obtained from the determination of placebos that were spiked with 0.25-1.00 mg/L primaquine. The proposed CE method was successfully applied to the assay of primaquine diphosphate in pharmaceutical formulations (tablets).  相似文献   