1.
针对近5年内在分析化学领域出现的微量样品预处理新技术(包括纤维管内固相微萃取、中空膜萃取、动态三相微萃取等),根据分离机理分成两大类,从原理、仪器装置和应用等方面作一综述。  相似文献   

2.
On-line coupling of miniaturized solid-phase extraction methods and microcolumn separation techniques are reviewed. A conventional solid-phase micro-extraction device and fiber-in-tube solid-phase extraction was employed as the sample preparation method. In the fiber-in-tube technique, a novel fibrous polymeric material was introduced as the extraction medium for the microscale sample preparation step which could be directly coupled with microcolumn liquid-phase separation systems, such as microcolumn liquid chromatography, capillary electrophoresis, and capillary electrochromatography. The applications of these hyphenated systems, consisting of the sample preparation and separation processes, are also reviewed.  相似文献   

3.
An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported.  相似文献   

4.
兽药残留分析中样品前处理技术研究进展   总被引:7,自引:0,他引:7  
样品前处理是兽药残留分析中的关键步骤,直接影响检测的结果.近年来,出现了一些新的样品前处理技术,如固相萃取、基质固相分散萃取、固相微萃取、搅拌棒吸附萃取、膜萃取、液相微萃取、超临界流体萃取、加速溶剂萃取、分子印迹、微波辅助萃取.这些技术能够有效地减少分析过程中由样品前处理过程带来的误差,具有前处理快速、简便的优点,同时可与分析仪器联用,实现分析的自动化.本文对这些新技术的基本原理、特点及在兽药残留分析中的应用进行了综述,并对样品前处理的前景进行了展望.  相似文献   

5.
张雨佳  凌云  张元  张峰 《色谱》2019,37(12):1268-1274
双酚类物质作为一种环境内分泌干扰物,广泛存在于食品包装材料及环境介质中,对生态环境造成污染,也对人体健康产生一定危害。双酚残留是目前重要的食品安全问题,检测食品和环境样品中的双酚类物质的含量对人体健康具有重要的意义。由于残留目标物浓度通常较低,且实际样品存在基质干扰,因此需经一定的样品前处理,并结合仪器分析方法,提高检测效率,增强分析灵敏度与可靠性。常用的前处理分析方法主要有液液萃取、微波辅助萃取、固相萃取、固相微萃取、基质分散固相萃取、QuEChERS等,常用仪器分析方法包括液相色谱法、气相色谱法、毛细管电泳法、酶联免疫吸附测定法、生物传感器法等。该文综述了食品及环境样品中双酚类物质的样品前处理及仪器分析方法,为双酚类化合物的残留监测提供了参考依据。  相似文献   

6.
Accurate quantitative analysis of trace analytes in a complicated matrix is a challenge in modern analytical chemistry. An appropriate analytical method is considered to be one of the most common gaps during the whole process. In this study, a green and efficient strategy based on miniaturized matrix solid-phase dispersion and solid-phase extraction combined with capillary electrophoresis was first proposed for extracting, purifying and determining target analytes from complicated matrix, using Wubi Shanyao Pill as an example. In detail, 60 mg of samples were dispersed on MCM-48 to obtain high yields of analytes, then the extract was purified with a solid-phase extraction cartridge. Finally, four analytes in the purified sample solution were determined by capillary electrophoresis. The parameters affecting the extraction efficiency of matrix solid-phase dispersion, purification efficiency of solid-phase extraction and separation effect of capillary electrophoresis were investigated. Under the optimized conditions, all analytes demonstrated satisfactory linearity (R2>0.9983). What's more, the superior green potential of the developed method for the determination of complex samples was confirmed by the Analytical GREEnness Metric Approach. The established method was successfully applied in the accurate determination of target analytes in Wubi Shanyao Pill and thus provided reliable, sensitive, and efficient strategy support for its quality control.  相似文献   

7.
Miniaturized solid-phase extraction (SPE) has been developed and successfully employed for the determination of organic species in water samples by liquid chromatography (LC). The method is based on the concept of a microscale extraction technique using a fused-silica capillary column for gas chromatography (GC), so-called in-tube solid-phase microextraction (SPME). The extraction conditions, such as the extraction time and flow-rate for the extraction and desorption process, were investigated as well as the effect of the internal structure of the extraction capillary on the efficiency. By inserting a stainless steel wire into the extraction capillary to reduce the internal volume of the capillary with the same surface area of the coating, an improved extraction and pre-concentration effects were obtained. Further pre-concentration was accomplished by the extraction device with a novel fiber-in-tube configuration. The direct coupling of the extraction method with a LC system has made it possible to determine low levels of phthalates in water samples without high consumption of organic solvents. The system developed must have potential applications for the analysis of environmental and biological samples in aqueous sample matrices.  相似文献   

8.
In order to combat a variety of pests, pesticides are widely used in fruits. Several extraction procedures (liquid extraction, single drop microextraction, microwave-assisted extraction, pressurized liquid extraction, supercritical fluid extraction, solid-phase extraction, solid-phase microextraction, matrix solid-phase dispersion, and stir bar sorptive extraction) have been reported to determine pesticide residues in fruits and fruit juices. The significant change in recent years is the introduction of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods in these matrices analysis. A combination of techniques reported the use of new extraction methods and chromatography to provide better quantitative recoveries at low levels. The use of mass spectrometric detectors in combination with liquid and gas chromatography has played a vital role to solve many problems related to food safety. The main attention in this review is on the achievements that have been possible because of the progress in extraction methods and the latest advances and novelties in mass spectrometry, and how these progresses have influenced the best control of food, allowing for an increase in the food safety and quality standards.  相似文献   

9.
Since the first report in 1991, carbon nanotubes (CNTs) have shown great possibilities for a wide variety of processes and applications, which include their use as electrodes, sensors (gas, enzymatic, etc.), nanoprobes, electronic materials, field emitters, etc. The combination of structures, dimensions and topologies has provided physical and chemical attractive properties that are unparalleled by most known materials. Their applications have also reached the Analytical Chemistry field in which CNTs are being used as matrices in matrix assisted laser desorption ionization, stationary phases in either gas chromatography, high performance liquid chromatography or capillary electrochromatography, also as pseudostationary phases in capillary electrophoresis, etc. as well as new solid-phase extraction (SPE) materials. Concerning this last application the number of works has considerably increased in the last five years. This review article pretends to focus on the most important features and different applications of SPE using CNTs (including matrix solid-phase dispersion and solid-phase microextraction) covering articles published since their introduction up to now (September 2009).  相似文献   

10.
Here, a simple, reliable method for the quantification of the 16 EPA priority polycyclic aromatic hydrocarbons in dried blood spots is outlined using liquid extraction and phospholipid solid-phase sample cleanup coupled with analysis by ultra-performance liquid chromatography with ultraviolet–visible detection. Whole blood spotted on Whatman FTA cards was efficiently quantified by extraction into acidified methanol and passed through a phospholipid solid-phase extraction well plate before injection into a liquid chromatography under reverse-phase conditions. The analyte recoveries in quality control samples ranged from 63.4 to 104.1%, with relative standard deviations from 0.48 to 2.04%. These figures of merit are comparable with measurements in whole blood or serum using similar techniques. The method detection limits were from 45.0?ng·g?1 for benzo[g,h,i]perylene to 118.7?ng·g?1 for chrysene, with matrix spike recoveries from 64.3 to 99.4%, demonstrating acceptable sensitivity and low matrix interference. With a simple liquid extraction approach and short 16-min liquid chromatography, the dried blood spots were effectively and rapidly analyzed.  相似文献   

11.
Applications of capillary electrophoresis (CE) and capillary liquid chromatography (LC) to environmental analysis have been limited. In this work we present applications of micellar electrokinetic chromatography (MEKC) to the analysis of environmental matrices for synthetic dyes. Separations obtained by capillary LC are compared with those obtained under MEKC for seven selected dyes. Both techniques are capable of resolving the subject compounds at high efficiency. Recovery data for spiked water and soil matrices were obtained for four dyes using solid-phase extraction cartridges and disks with determination by MEKC-UV detection. Both pH adjustment via acid and ion-pairing via a cationic surfactant were investigated for isolating dyes. Capillary LC detection was by continuous-flow liquid secondary ion mass spectrometry (CF-LSI-MS) whereas MEKC used UV detection (214 nm). Application of peak-profiling at high mass resolution is illustrated with the capillary LC-MS technique. Interfacing capillary LC under CF-LSI-MS using the coaxial arrangement is easier than interfacing CE with this arrangement. MEKC provides a powerful screening and determinative technique, while capillary LC-MS provides a confirmatory tool.  相似文献   

12.
Summary Sample pretreatment is often the bottleneck of a tracelevel analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.  相似文献   

13.
B. Mile 《Chromatographia》2005,62(1-2):3-9
Chromatographic separation techniques are now widely used to examine the material evidence associated with a crime. Four areas are considered. Analysis of drugs of abuse by GC, GC-MS and GC-FTIR; HPLC; chiral chromatography; capillary electrophoresis (CE) and capillary electrochromatography (CEC); solid-phase microextraction (SPME). The quantitative detection of adulterants and trace pesticides in foods using supercritical fluid extraction (SFE). DNA profiling by separation of fragments by gel and capillary electrophoresis and fluorescence detection. Future developments in automation and miniaturisation and the design of microchips and micro-electrode devices allowing complete analysis in 8 μL cells.  相似文献   

14.
The molecularly imprinted polymers (MIPs) are synthetic polymers possessing specific cavities designed for a target molecule. By a mechanism of molecular recognition, the MIPs are used as selective tools for the development of various analytical techniques such as liquid chromatography, capillary electrochromatography, solid-phase extraction (SPE), binding assays and biosensors. This review describes the application of MIPs to the determination of environmental pollutants in these different analytical approaches with a special emphasis on their potential as selective SPE sorbent for the selective extraction of target analytes from complex matrices.  相似文献   

15.
The main physicochemical methods for identifying and quantifying polyphenol compounds in various plant and food objects (tea, wine) and human biological fluids (urine, plasma, blood serum, saliva) were reviewed, such as chromatography (high-performance liquid chromatography and thin-layer chromatography) and electrophoresis (capillary zone electrophoresis and micellar electrokinetic chromatography). Different procedures for sample preparation were discussed, including liquid, solid-phase, supercritical fluid extraction, and high-pressure liquid extraction.  相似文献   

16.
17.
A demanding task in pesticide residue analysis is yet the development of multi-residue methods for the determination of pesticides in vegetables with relatively high fat content (i.e. edible oils and fatty vegetables). The separation of pesticides and other chemical contaminants from high-fat food samples prior to subsequent steps in the analytical process is yet a challenging issue to which much effort in method development has being applied. This review addresses the main sample treatment methodologies for pesticide residue analysis in fatty vegetable matrices. Even with the advent of advanced hyphenated techniques based on mass spectrometry these complex fatty matrices usually require extensive sample extraction and purification. Current methods involve the use of one or the combination of some of the following techniques for both the sample extraction and clean-up steps: liquid-liquid partitioning, solid-phase extraction (SPE), gel-permeation chromatography (GPC), matrix solid-phase dispersion (MSPD), etc. An overview of methods developed for these contaminants in fatty vegetables matrices is presented. Sample extraction and purification techniques are discussed and their most recent applications are highlighted. This review emphasizes that sample preparation is a critical step, but also the determination method is, and cannot be treated separately from sample treatment. In recent years, the appearance and use of new, more polar pesticides has fostered the development of liquid chromatography/mass spectrometry (LC-MS) besides gas chromatography. The main features of LC-MS for the analysis of multi-class pesticides in fatty vegetable samples will be also underlined, with an emphasis on the multi-class, multi-residue strategy and the difficulties associated.  相似文献   

18.
Pesticides are applied widely to protect plants from disease, weeds and insect damage, and usually come into contact with soil, where they undergo a variety of transformations that provide a complex pattern of metabolites. This article reviews the most relevant analytical methods for determining pesticides and their transformation products in soils. We address some recent advances in sampling and sample-preparation technologies for soil analysis. We discuss and critically evaluate procedures, such as liquid extraction methods (pressurized liquid extraction or microwave-assisted extraction) and solid-phase based methods (headspace solid-phase microextraction, solid-phase microextraction or matrix-solid-phase dispersion). Analysis of pesticides is generally carried out by gas chromatography (GC) or liquid chromatography (LC) coupled to different detectors, especially to mass spectrometers (MSs). However, alternative and/or complementary methods, using capillary electrophoresis (CE), biosensors and bioassays have emerged recently. We also consider the advantages and the disadvantages of the various methodologies.  相似文献   

19.
食品农药残留分析进展   总被引:89,自引:0,他引:89  
对食品中农药残留分析技术及其进展进行了综述。样品前处理中,除固相萃取外,超临界流体萃取和基质固相分散得到了飞速发展和广泛应用。原子激发检测器在气相色谱中发展较快,超临界流体色谱和免疫分析技术开发应用于食品农药残留分析中。并对农药残留分析的发展趋势和要求进行了讨论。  相似文献   

20.
A method was developed for determining flumioxazin in soil and water. Recovery efficiencies for solid-phase extraction (SPE) of flumioxazin from deionized, well, and surface water were between 72 and 77%. SPE was superior to liquid-liquid extraction, using water-hexane and water-chloroform emulsions, which resulted in retrieval efficiencies of 25 and 22%, respectively. However, liquid-liquid extraction with ethyl acetate improved recovery of total flumioxazin to >64%. Extraction from soil samples by direct solvent/soil extraction methods recovered between 18 and 76% of applied flumioxazin, depending on the solvent combination used. However, the use of accelerated solvent extraction techniques resulted in a 106 +/- 8% recovery of flumioxazin from soil. In analysis by capillary gas chromatography with mass selective detection, flumioxazin had a calculated limit of detection of 9 ng/mL with a retention time of 16.66 min.  相似文献   