首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode was prepared by electrochemical polymerization technique. The properties of modified electrode was studied. It was found that the electrochemical properties of modified electrode was very much dependent on the experimental conditions, such as monomer oxidation potential and pH. The modified electrode surface was characterized by scanning electron microscopy (SEM). The PEDOT-PANS film modified electrode shows electrocatalytic activity toward oxidation of dopamine (DA) in acetate buffer solution (pH 5.0) and results in a marked enhancement of the current response. The linear sweep voltammetric (LSV) peak heights are linear with DA concentration from 2 × 10−6 to 1 × 10−5 M. The detection limit is 5 × 10−7 M. More over, the interferences of ascorbic acid (AA) and uric acid (UA) were effectively diminished. This work provides a simple and easy approach for selective determination of dopamine in the presence of ascorbic acid and uric acid.  相似文献   

2.
A novel bimediator amperometric sensor is fabricated for the first time by surface modification of graphite electrode with thionine (TH) and nickel hexacyanoferrate (NiHCF). The electrochemical behavior of the TH/NiHCF bimediator modified electrode was characterized by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The TH/NiHCF bimediator modified electrode exhibited a pair of distinct redox peaks for NiHCF and TH with formal potentials of 0.33 V and −0.27 V vs. SCE at a scan rate of 50 mV s−1 in 0.1 M NaNO3 and 0.1 M NH4NO3 respectively. The electrocatalytic activity of the bimediator modified electrode towards oxidation of gallic acid with NiHCF and reduction of hydrogen peroxide with TH was evaluated and it was observed that the modified electrode showed an electrocatalytic activity towards the oxidation of gallic acid in the concentration range of 4.99 × 10−6–1.20 × 10−3 M with a detection limit of 1.66 × 10−6 M (S/N = 3) and reduction of H2O2 in the concentration range of 1.67 × 10−6–1.11 × 10−3 M with a detection limit of 5.57 × 10−7 M (S/N = 3). The bimediator modified electrode was found to exhibit good stability and reproducibility.  相似文献   

3.
The mixed‐valent nickel hexacyanoferrate (NiHCF) and poly(3,4‐ethylenedioxythiophene) (PEDOT) hybrid film (NiHCF‐PEDOT) was prepared on a glassy carbon electrode (GCE) by multiple scan cyclic voltammetry. The films were characterized using atomic force microscopy, field emission scanning electron microscopy, energy dispersive spectroscopy, X‐ray diffraction, and electrochemical impedance spectroscopy (AC impedance). The advantages of these films were demonstrated for the detection of ascorbic acid (AA) using cyclic voltammetry and amperometric techniques. The electrocatalytic oxidation of AA at different electrode surfaces, such as the bare GCE, the NiHCF/GCE, and the NiHCF‐PEDOT/GCE modified electrodes, was determined in phosphate buffer solution (pH 7). The AA electrochemical sensor exhibited a linear response from 5×10−6 to 1.5×10−4 M (R2=0.9973) and from 1.55×10−4 to 3×10−4 M (R2=0.9983), detection limit=1×10−6 M, with a fast response time (3 s) for AA determination. In addition, the NiHCF‐PEDOT/GCE was advantageous in terms of its simple preparation, specificity, stability and reproducibility.  相似文献   

4.
Qian L  Yang X 《Talanta》2006,68(3):721-727
A new amperometric biosensor for hydrogen peroxide was developed based on cross-linking horseradish peroxidase (HRP) by glutaraldehyde with multiwall carbon nanotubes/chitosan (MWNTs/chitosan) composite film coated on a glassy carbon electrode. MWNTs were firstly dissolved in a chitosan solution. Then the morphology of MWNTs/chitosan composite film was characterized by field-emission scanning electron microscopy. The results showed that MWNTs were well soluble in chitosan and robust films could be formed on the surface. HRP was cross-linked by glutaraldehyde with MWNTs/chitosan film to prepare a hydrogen peroxide biosensor. The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for H2O2 in the absence of a mediator. The linear range of detection towards H2O2 (applied potential: −0.2 V) was from 1.67 × 10−5 to 7.40 × 10−4 M with correction coefficient of 0.998. The biosensor had good repeatability and stability for the determination of H2O2. There were no interferences from ascorbic acid, glucose, citrate acid and lactic acid.  相似文献   

5.
The optimization of a biosensor prepared by the immobilization of oxalate oxidase (OOX) with a cross-linking agent onto a multilayer inorganic/organic modified electrode, is presented. A very thin Prussian Blue (PB) film covered by a self-doped polyaniline (SPAN) layer acts as very sensitive amperometric sensor for the H2O2 formed by the enzymatic reaction. The electrode allows the very reliable and sensitive oxalate detection in the 0.08 to 0.45 mmol l−1 concentration range. The observed sensitivity was 131.3 μA mmol−1 cm−2 at the operation potential of 0.05 V versus Ag/AgCl in a succinate buffer solution (pH=3.8). The bilayer Prussian blue/SPAN leads to a very stable, sensitive and selective system that not only minimizes the interference caused by ascorbic and uric acids but also forms a very adherent sensing film that allows repetitive successive determinations.  相似文献   

6.
Properties of single foam films prepared with tetraethylammonium perfluorooctane-sulfonate (TAPOS) were studied. Film thickness was measured as a function of NH4Cl concentration in the film forming solution. The dependence of the film disjoining pressure versus the film thickness (disjoining pressure isotherms) and the mean lifetime of the films were studied. The dependence of the film thickness on the electrolyte concentration showed the presence of an electrostatic double layer at the film surfaces. The electrostatic double layer component of the disjoining pressure was screened at a NH4Cl concentration higher than 0.2 M where Newton black films (NBFs) of 6 nm thickness were formed. These films are bilayers of amphiphile molecules and contain almost no free water. The disjoining pressure isotherms of the foam films formed with 0.001 M TAPOS were measured at two different NH4Cl concentrations (0.005 and 0.0005 M). The Deryaguin-Landau-Verwey-Overbeek (DLVO) theory describes well the isotherms with an electrostatic double layer potential of ∼140 mV. The mean lifetime, a measure of the stability of the NBFs, was measured depending on surfactant concentrations. The observation of NBF was possible above a minimum TAPOS concentration of 9.4 × 10−5 M. Above this concentration, the lifetime increases exponentially. The dependence of the film lifetime on surfactant concentration is explained by the theory for NBF-rupture by nucleation mechanism of formation of microscopic holes.  相似文献   

7.
Baozhen Wang 《Talanta》2007,72(2):415-418
Multilayer thin films composed of poly(allylamine hydrochloride) (PAH) and carboxymethyl cellulose (CMC) have been prepared on the surface of a gold (Au) disk electrode by a layer-by-layer deposition of PAH and CMC and ferricyanide ions ([Fe(CN)6]3−) were confined in the film. [Fe(CN)6]3− ions can be successfully confined in the films from weakly acidic or neutral [Fe(CN)6]3− solutions, while, in basic solution, [Fe(CN)6]3− ion was not confined. The [Fe(CN)6]3− ion-confined Au electrode showed clear redox peaks in the cyclic voltammogram around 0.35 V versus Ag/AgCl. The amounts of [Fe(CN)6]3− ions confined in the films depended on the thickness of the films or the number of layers in the LbL films. The [Fe(CN)6]3− ion-confined Au electrode was used for electrocatalytic determination of ascorbic acid in the concentration range of 1-50 mM.  相似文献   

8.
Maki T  Soh N  Nakano K  Imato T 《Talanta》2011,85(4):1730-1733
A simple and sensitive flow injection fluorometric method for the determination of ascorbic acid is described. Perylenebisimide-linked nitroxide (PBILN) is used as a fluorescent reagent, which permits the selective determination of ascorbic acid. The fluorescence of the perylenebisimide moiety in PBILN is quenched by the nitroxide moiety, which is linked to the perylenebisimide. When a stream of a solution of ascorbic acid is merged with a stream of PBILN, the ascorbic acid reacts with the nitroxide moiety of PBILN to form hydroxylamine, and the fluorescence properties of the perylenebisimide moiety are recovered. As a result, a peak-shaped fluorescence signal is produced, which can be observed by a fluorescence detector located downstream. Under optimized conditions, a good linear relationship between the concentration of ascorbic acid and peak height in the concentration range from 0.5 to 10 μmol L−1 was found and the detection limit (S/N = 3) was 0.28 μmol L−1. The relative standard deviation for the determination of 4.0 μmol L−1 ascorbic acid samples was 1.0% (n = 5). The proposed method was applied to the determination of ascorbic acid in several soft drink beverages and the analytical results were in good agreement with those obtained using a conventional method.  相似文献   

9.
Methylene blue (MB) was incorporated into mordenite zeolite by ion exchange reaction in aqueous phase. The dye is strongly retained and not easily leached from the zeolite matrix. The solid was characterized by XRD prior to using it for the electrode preparation. This compound was incorporated into a carbon paste electrode for cyclic voltammetric and amperometric measurements. Methylene blue immobilized on the support underwent a quasi-reversible electrochemical redox reaction. In various electrolyte solutions and changing the pH between 2.0 and 7.0, the midpoint potential remained practically constant, i.e. 153.7±0.8 mV. This is not the usual behavior of MB, because in solution phase its midpoint potential changes considerably as the pH changes. The electrode made with this material was used for the mediated oxidation of ascorbic acid. The anodic peak current observed in cyclic voltammetry was linearly dependent on the ascorbic acid concentration. At a fixed potential under static conditions, the calibration plot was linear over the ascorbic acid concentration range 2.0×10−5 to 8.0×10−4 M. The detection limit of the method is 1.21×10−5 M, low enough for trace ascorbic acid determination in various real samples.  相似文献   

10.
Wang K  Xu JJ  Tang KS  Chen HY 《Talanta》2005,67(4):798-805
A novel solid-contact potentiometric sensor for ascorbic acid based on cobalt phthalocyanine nanoparticles (NanoCoPc) as ionophore was fabricated without any need of auxiliary materials (such as membrane matrix, plasticizer, and other additives). The electrode was prepared by simple drop-coating NanoCoPc colloid on the surface of a glassy carbon electrode. A smooth, bright and blue thin film was strongly attached on the surface of the glassy carbon electrode. The electrode showed high selectivity for ascorbic acid, as compared with many common anions. The influences of the amount of NanoCoPc at the electrode surface and pH on the response characteristics of the electrode were investigated. To overcome the instability of the formal potential of the coated wire electrode, a novel electrochemical pretreatment method was proposed for the potentiometric sensor based on redox mechanism. This resulting sensor demonstrates potentiometric response over a wide linear range of ascorbic acid concentration (5.5 × 10−7 to 5.5 × 10−2 M) with a fast response (<15 s), lower detection limit (ca. 1.0 × 10−7 M), and a long-term stability. Furthermore, microsensors based on different conductors (carbon fiber and Cu wire) were also successfully fabricated for the determination of practical samples.  相似文献   

11.
A glassy carbon electrode modified with poly(alizarin red)/electrodeposited graphene (PAR/EGR) composite film was prepared and applied to detect ciprofloxacin (CPFX) in the presence of ascorbic, uric acid and dopamine. The morphology and interface property of PAR/EGR films were examined by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electrocatalytic oxidation of CPFX on AR/EGR was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linearity ranged from 4 × 10−8 to 1.2 × 10−4 M with a detection limit (S/N = 3) of 0.01 μM. The modified electrode could be applied to the individual determination of CPFX as well as the simultaneous determination of CPFX, ascorbic acid, uric acid and dopamine. This method proved to be a simple, selective and rapid way to determine CPFX in pharmaceutical preparation and biological media.  相似文献   

12.
Nitro blue tetrazolium polyvinyl alcohol film dosimeters, NBT-PVA were prepared and evaluated based on radiation-induced reduction of NBT2+. NBT-PVA film dosimeters containing different concentrations of NBT dye from 1 to 5 mM were prepared in a solution of ethanol. The dosimeters were irradiated with ?-ray from 60Co source at doses up to 50 kGy. UV/vis spectrophotometer was used to investigate the optical density of un-irradiated and irradiated films in terms of absorbance at 529 nm. The absorbance increases with absorbed dose up to 50 kGy for NBT-PVA film dosimeters. The dose sensitivity of NBT-PVA film increases strongly with increase of concentrations of NBT dye. The effects of irradiation temperature, humidity, dose rate and the stability of the response of the films after irradiation were investigated. A considerable increase was observed in the dose response of NBT-PVA film by adding appropriate concentration of sodium formate and Triton X-100.  相似文献   

13.
Two vitamin C species of ascorbic acid and dehydroascorbic acid in aqueous solution were monitored by flow injection analysis. Ascorbic acid and dehydroascorbic acid were resolved by a reversed-phase column, and dehydroascorbic acid was reduced to ascorbic acid by an on-line post-column reaction with dithiothreitol. Both natural and reduced ascorbic acids were photometrically detected at 260 nm, and the two vitamin C species were simultaneously determined. The determination range was from 0 to 8 × 10−5 M with a limit of detection of 1.7 × 10−6 M. The proposed method was applied to the conversion monitoring of ascorbic acid and dehydroascorbic acid in weakly acidic to weakly alkaline aqueous solutions, as well as to the determination of the vitamin C in some beverage samples.  相似文献   

14.
Design and fabrication of an ammonia sensor operating at room temperature based on pigment-sensitized TiO2 films was described. TiO2 was prepared by sol–gel method and deposited on glass slides containing gold electrodes. Then, the film immersed in a 2.5 × 10−4 M ethanol solution of cyanidin to absorb the pigment. The hybrid organic–inorganic formed film here can detect ammonia reversibly at room temperature. The relative change resistance of the films at a potential difference of 1.5 V is determined when the films are exposed to atmospheres containing ammonia vapors with concentrations over the range 10–50 ppm. The relative change resistance, S, of the films increased almost linearly with increasing concentrations of ammonia (r = 0.92). The response time to increasing concentrations of the ammonia is about 180–220 s, and the corresponding values for decreasing concentrations 240–270 s. At low humidity, ammonia could be ionized by the cyanidin on the TiO2 film and thereby decrease in the proton concentration at the surface. Consequently, more positively charged holes at the surface of the TiO2 have to be extracted to neutralize the adsorbed cyanidin and water film. The resistance response to ammonia of the sensors was nearly independent on temperature from 10 to 50 °C. These results are not actually as good as those reported in the literature, but this preliminary work proposes simpler and cheaper processes to realize NH3 sensor for room temperature applications.  相似文献   

15.
E.K. Janghel  V.K. Gupta  J.K. Rai 《Talanta》2007,72(3):1013-1016
A new simple and sensitive analytical spectrophotometric method is developed for the determination of ascorbic acid reduces methyl viologen to form a stable blue coloured free radical ion. This method has a sensitivity and lower limit detection of 0.1 μg ml−1 of ascorbic acid (0.1 ppm) which is comparable to the flow injection analysis reported earlier. Beer's law is obeyed over the concentration range of 1.0-10 μg ml−1 of ascorbic acid per 10 ml of the final solution (0.1-1.0 μg ml−1) at 600 nm. The molar absorptivity and Sandell's sensitivity were found to be 1.5 × 105 ± 100 l mol−1 cm−1 and 0.001 μg cm−2, respectively. The method has been applied to the determination of ascorbic acid in food, pharmaceuticals and biological samples.  相似文献   

16.
A new method is developed for the catalytic oxidation of ascorbic acid at graphite zeolite-modified electrode, doped with copper(II) (Cu2+A/ZCME). Copper(II) exchanged in zeolite type A acts as catalyst to oxidize ascorbic acid. The modified electrode lowered the overpotential of the reaction by ∼400 mV. First, the electrochemical behavior of copper(II), incorporated in the zeolite type A modified electrode, was studied. The results illustrate that diffusion can control the copper(II)/copper(0) redox process at the Cu2+A/ZCME. Then, the behavior of electrocatalytic oxidation reaction for ascorbic acid was researched. The electrode was employed to study electrocatalytic oxidation of ascorbic acid, using cyclic voltammetry and chronoamperometry as diagnostic techniques. The diffusion coefficient of ascorbic acid was equal to 1.028 × 10−5 cm2 s−1. A linear calibration graph was obtained over the ascorbic acid with a concentration range of 0.003-6.00 mmol L−1. The detection limit (DL) of ascorbic acid was estimated as 2.76 × 10−7 mol L−1. The relative standard deviations of 10 replicate measurements (performed on a single electrode at several ascorbic acid concentrations between 3.0 and 200 μmol L−1) were measured between 1.0 and 2.4%.  相似文献   

17.
A ‘self-doped’ polyaniline modified microelectrode, prepared by cyclic potential sweep on a microdisk gold electrode from –0.2 to 0.85 V in 0.5 mol/L sulfuric acid containing aniline and o-aminobenzoic acid, has been developed. The copolymerized process and the resulting polymer characteristics were investigated in detail. This composite film indicated a good electrochemical activity in a wide pH range even in basic solution. Meanwhile, the redox couple exhibited an excellent electrocatalytic activity for the oxidation of ascorbic acid. The oxidation overpotential of ascorbic acid was decreased over 200 mV at this modified electrode compared with a bare gold one. Moreover, the effects of film thickness and pH on the catalytic efficiency were further studied. The dependence of catalytic currents on the concentration of ascorbic acid was linear in the range of 1.2 × 10–5∼ 2.4 × 10–3 mol/L with a correlation coefficient of 0.996. Also, the determination of ascorbic acid in actual samples was evaluated and the results are satisfactory. Received: 7 October 1997 / Revised: 3 February 1998 / Accepted: 7 February 1998  相似文献   

18.
The present work reports a quercetin-modified wax-impregnated graphite electrode (Qu/WGE) prepared through an electrochemical oxidation procedure in quercetin-containing phosphate buffer solution (PBS), for the purpose of detecting uric acid (UA) in the presence of ascorbic acid (AA). During modification quercetin was oxidized to the corresponding quinonic structure, and in the blank buffer solution the electrodeposited film exhibits a voltammetric response anticipated for the surface-immobilized quercetin. Retarding effect of the film towards the reaction of anionic species was found; therefore the pH of sample solutions was selected to ensure the analyte in molecular form. At suitable pHs the Qu/WGE shows excellent electrocatalytic effect towards the oxidation of both AA and UA, and separates the voltammetric signal of UA from AA by about 280 mV, allowing simultaneous detection of these two species. A linear relation between the peak current and concentration was obtained for UA in the range of 1-50 μM in the presence of 0.5 mM AA, with a detection limit 1.0 μM (S/N = 3). This sensor was stable, reproducible and outstanding for long-term use.  相似文献   

19.
In this paper, ascorbic acid as a new carbon dioxide (CO2) absorbent was investigated. The equilibrium solubility of CO2 into 0.5, 1 and 1.5 mol dm−3 (M) aqueous ascorbic acid solutions were measured experimentally with a stirred batch reactor at total atmospheric pressure over the CO2 partial pressure ranging from 0 to 45 kPa and temperatures between 298 and 313 K. The results of the gas solubility are presented as loading capacity (mol CO2/mol ascorbic acid) as function of partial pressure of CO2 for all experimental runs. Experimental results showed that solubility of CO2 increases with increase in molar concentration of ascorbic acid solution at a given temperature and decreases with increase in temperature at a given concentration. The densities and viscosities of the ascorbic acid solutions were measured at the same conditions of the solubility measurement. Some corrosion rate tests were also performed on carbon steel at temperature of 308 K. It was observed that viscosity and corrosion rate increase when the molar concentration of ascorbic acid solution increases.  相似文献   

20.
Salimi A  Abdi K 《Talanta》2004,63(2):475-483
The electroless sol-gel technique was used for the construction of nickel hexacyanoferrat (NiHCF) modified carbon composite electrodes (CCEs).This involves two steps: formation of a carbon ceramic electrode fabricated by nickel powder and then immersing the electrode into a sodium- hexacyanoferate solution for the immobilization of NiHCF films. The cyclic voltammety of the resulting modified CCEs prepared under optimum conditions, shows a well defined surface redox couple due to the [NiIIFeIII/II(CN)6]−2/−1 system. The effect of different alkali metal cations in supporting electrolyte on the behavior of the modified electrode were studied. The charge transfer coefficient (α) and charge transfer rate constant (ks) for modified films were calculated. Hydrazine and hydroxylamine have been chosen as a model to elucidate the electocatalytic ability and analytical parameters of NiHCF modified CCE prepared by one and two-step sol-gel techniques and these compounds determined amperometically at the surface of modified electrodes. The latter shows a good electocatalytic activity towards the oxidation of hydrazine and hydroxylamine in the pH range 3-8 in comparison with CCEs modified by homogeneous mixture of graphite powder, Ni(NO3)2 and Na2[Fe(CN)6], (one-step sol-gel technique). Furthermore, the catalytic rate constant, linear dynamic range, limit of detection, and sensitivity for hydrazine and hydroxylamine detections were evaluated and compared with CCEs prepared with one-step sol-gel method. The modified CCEs containing NiHCF shows good repeatability, short response time, t 90%<3 s, long term stability (3 months) and excellent catalytic activity. Furthermore, the method of preparation is rapid and simple and the modified electrodes are renewed by simple mechanical polishing and immersing in [Na3Fe(CN]6] solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号