首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive and selective RP-HPLC method has been developed for quantification of nodakenin in rat plasma. Nodakenin in rat plasma was extracted with acetonitrile, which also acted as a deproteinization agent. Chromatographic separation of nodakenin was performed on an analytical Diamonsil ODS C18 column, with a mobile phase of MeOH-H2O (1:1, v/v) at a flow-rate of 1.0 mL/min, and UV detection was set at 330 nm. The calibration curve was linear over the range 0.2-12.0 microg/mL (R2 = 0.9995) in rat plasma. The lower limit of detection and quantification were 0.01 and 0.1 microg/mL, respectively, using the rat plasma sample. The extraction recoveries were 77.36 +/- 4.56, 82.89 +/- 1.84 and 81.66 +/- 2.49% at concentrations of 1.0, 5.0 and 10.0 microg/mL, respectively. The intra- and inter-day precision and accuracy were validated by relative standard deviation and relative error, which were in the ranges 5.07-5.83 and 3.95-6.29%, respectively. After i.v. administration to rats at a single dose of 40 mg/kg, the plasma concentration-time curve of nodakenin was best conformed to a two-compartment open model. This assay method has been successfully applied to the study of the pharmacokinetics of nodakenin in rats.  相似文献   

2.
A simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C(18) analytical column using acetonitrile-water (25:75, v/v) as the mobile phase and a UV detection at 330 nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0 μg/mL, respectively. The standard curve for nodakenin was linear (r(2) ≥ 0.99) over the concentration range 0.250-50.0 μg/mL with a lower limit of quantification of 0.250 μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ± 5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution.  相似文献   

3.
For the first time, a selective and sensitive chiral HPLC-UV method was developed and fully validated for the simultaneous quantification of eslicarbazepine acetate (ESL), carbamazepine (CBZ), S-licarbazepine (S-Lic), R-licarbazepine (R-Lic), oxcarbazepine (OXC) and carbamazepine-10,11-epoxide (CBZ-E), in mouse plasma and brain homogenate supernatant. After the addition of chloramphenicol as the internal standard, samples were processed using an SPE procedure. The chiral chromatographic analysis was carried out on a LiChroCART 250-4 ChiraDex column, employing a mobile phase of water and methanol (88:12, v/v) pumped at 0.9 mL/min and the UV detector set at 235 nm. The assay was linear (r(2) ≥0.995) for ESL, CBZ, OXC, S-Lic, R-Lic and CBZ-E in the range of, respectively, 0.2-4, 0.4-30, 0.1-60, 0.2-60, 0.2-60 and 0.2-30 μg/mL, in plasma, and of 0.06-1.5 μg/mL for ESL, 0.12-15 μg/mL for CBZ and CBZ-E and 0.06-15 μg/mL for OXC and both licarbazepine (Lic) enantiomers in brain homogenate supernatant. The overall precision was within 8.71% and accuracy ranged from -7.55 to 8.97%. The recoveries of all the compounds were over 92.1%. Afterwards, the application of the method was demonstrated using real plasma and brain samples obtained from mice administered simultaneously with ESL and CBZ.  相似文献   

4.
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed for the determination of bergenin in rat plasma. Bergenin in rat plasma was extracted with methanol, which also acted as a deproteinization agent. Chromatographic separation of bergenin was performed on a C(18) column, with a mobile phase of methanol-water (22:78, v/v) at a flow-rate of 0.8 mL/min and an operating temperature of 40 degrees C, and UV detection was set at 220 nm. The calibration curve was linear over the range 0.25-50 microg/mL (r = 0.9990) in rat plasma. The limit of quantification was 0.25 microg/mL using a plasma sample of 100 microL. The extraction recoveries were 83.40 +/- 6.02, 81.49 +/- 2.40 and 72.51 +/- 2.64% at concentrations of 0.5, 5 and 50 microg/mL, respectively. The intra-day and inter-day precision and accuracy were validated by relative standard deviation (RSD%) and relative error (RE%), which were in the ranges 3.74-9.91 and -1.6-8.0%. After intravenous administration to rats at the dose of 11.25 mg/kg, the plasma concentration-time curve of bergenin was best conformed to a two-compartment open model. The main pharmacokinetic parameters indicated that bergenin exhibited a wide distribution and moderate elimination velocity in rat.  相似文献   

5.
Antimicrobial prophylactic dosing of morbidly obese patients may differ from normal weighted individuals owing to alterations in drug tissue distribution. Drug subcutaneous tissue distribution can be investigated by microdialysis patients and animals. The need for cefazolin prophylactic dose adjustment in obese patients remains under discussion. The paper describes the validation of an HPLC‐UV method for cefazolin quantification in plasma and microdialysate samples from clinical and pre‐clinical studies. A C18 column with an isocratic mobile phase was used for drug separation, with detection at 272 nm. Total and unbound cefazolin lower limit of quantitation was 5 μg/mL in human plasma, 2 μg/mL in rat plasma, and 0.5 and 0.025 μg/mL in human and rat microdialysate samples, respectively. The maximum intra‐ and inter‐day imprecisions were 10.7 and 8.1%, respectively. The inaccuracy was <9.7%. The limit of quantitation imprecision and inaccuracy were < 15%. Cefazolin stability in the experimental conditions was confirmed. Cefazolin plasma concentrations and subcutaneous tissue penetration were determined by microdialysis in morbidly obese patients (2 g i.v. bolus) and diet‐induced obese rats (30 mg/kg i.v. bolus) using the method. This method has the main advantages of easy plasma clean‐up and practicability and has proven to be useful in cefazolin clinical and pre‐clinical pharmacokinetic investigations.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic (RP-HPLC) method was described for the determination of chlorogenic acid (CGA) in rat plasma using protocatechuic acid as internal standard (IS). CGA in plasma was extracted with acetonitrile, which also acted as deproteinization agent. Chromatographic separation was performed on a Kromasil C18 column with methanol-0.2 m acetic acid (pH 3.0, 25:75, v/v) as mobile phase at a flow-rate of 1.0 mL/min with an operating temperature of 30 degrees C and UV detection at 300 nm. The standard curve was found to be linear over the concentration ranges of 0.4-2.5 microg/mL and 2.5-40 microg/mL, and the limit of quantification (LOQ) was 0.4 microg/mL. The analytical precision and accuracy were validated by relative standard deviation (RSD) and relative error, which were in ranges 3.14-10.78% and -2.20-5.00%, respectively. The average recovery of CGA was 87.59%. The method was successfully applied to the pharmacokinetic study of CGA in Yin-Huang granules.  相似文献   

7.
The objective of this study was the development, optimization, and validation of a novel reverse-phase high-pressure liquid chromatography (RP-HPLC) method for the quantification of reduced glutathione in pharmaceutical formulations utilizing simple UV detection. The separation utilized a C18 column at room temperature and UV absorption was measured at 215 nm. The mobile phase was an isocratic flow of a 50/50 (v/v) mixture of water (pH 7.0) and acetonitrile flowing at 1.0 mL/min. Validation of the method assessed the methods ability in seven categories: linearity, range, limit of detection, limit of quantification, accuracy, precision, and selectivity. Analysis of the system suitability showed acceptable levels of suitability in all categories. Likewise, the method displayed an acceptable degree of linearity (r(2) = 0.9994) over a concentration range of 2.5-60 μg/mL. The detection limit and quantification limit were 0.6 and 1.8 μg/mL respectively. The percent recovery of the method was 98.80-100.79%. Following validation the method was employed in the determination of glutathione in pharmaceutical formulations in the form of a conjugate and a nanoparticle. The proposed method offers a simple, accurate, and inexpensive way to quantify reduced glutathione.  相似文献   

8.
IntroductionTraditionally,Di-Gu-Pi has been used as a naturaltherapeutic agent for the treatment of diabetes,hemor-rhagic inframmation,hypertension,ulcers,and feverunder the guidance of the theory of Traditional ChineseMedicinal(TCM)science[1].This fact h…  相似文献   

9.
《Analytical letters》2012,45(11):1815-1838
Abstract

A high performance liquid chromatography analysis method has been developed for the quantitation of 2′,3′-dideoxyinosine (DDI) in plasma. Proteins were precipitated from plasma samples with acetonitrile containing the internal standard, 6-methylaminopurine riboside. The treated samples were evaporated to dryness and reconstituted in mobile phase for the analysis. Separation of the components was achieved on a 5 μm octadecylsilane column with ultraviolet detection at 254 nm. The method was validated at nine concentrations between 0.015 and 150 μg/mL. Using 500 μL of human plasma, the limit of quantitation was 120 ng/mL and the limit of detection was 60 ng/mL. The mean intra-day precision of the method was 1.6%. The mean accuracy of the method was within 2% of the actual values. This method is currently being used for pharmacokinetic studies in the rat.  相似文献   

10.
The objective of this study was to develop a fast and robust method for the quantitation of the antifungal drug anidulafungin in human plasma samples by generic two-dimensional liquid chromatography (online-SPE/reversed phase LC) coupled to a tandem-quadrupole mass spectrometer (LC-online SPE-MS/MS). Online SPE was performed using an Oasis HLB cartridge column and for reversed-phase chromatography a Nucleodur Gravity C(18) column was used. A 100 μL aliquot of human plasma was extracted with 200 μL of 80:20 MeOH-0.2 M ZnSO(4) (v/v) as precipitation reagent containing ascomycin as internal standard (IS). The supernatant was directly injected for analysis. The total run time was 4.5 min. Anidulafungin and ascomycin were detected in the positive ionization mode. The method performance data for anidulafungin, such as limit of detection (0.013 μg/mL), lower limit of quantitation (0.04 μg/mL), linearity (R(2) = 0.9999) and concentration range (0.04-10 μg/mL) were ascertained. Intra- and inter-day precisions were ≤6.6% and intra- and inter-day accuracies were 98.5-101.0 and 100.0-102.5%, respectively. The assay was successfully applied for quantitation of anidulafungin in patient plasma samples.  相似文献   

11.
Levonorgestrel and quinestrol, commonly known as EP‐1, has long been used in the control of wild rodents. Up to the present time, however, no method for simultaneous quantification of levonorgestrel and quinestrol in rat plasma has been reported. In the present study, a sensitive reverse‐phase high‐performance liquid chromatography with ultraviolet detection (RP‐HPLC‐UV) method for quantification of levonorgestrel and quinestrol in rat plasma has been developed. It uses a Kromasil ODS C18 column and acetonitrile‐0.1% formic acid (85 : 15, v/v) mobile phase at ambient temperature. The plasma sample was prepared by hexane–isoamyl alcohol extraction (90 : 10, v/v). The flow rate and detection wavelength were 1.0 mL/min and 230 nm. The correlation coefficients were greater than 0.9995 within 0.08–50 μg/mL for levonorgestrel and 0.12–50 μg/mL for quinestrol, and the limits of detection were 0.02 and 0.05 μg/mL for levonorgestrel and quinestrol, respectively. Average recovery ranged from 92.5 to 96.3% and inter‐day RSDs were less than 7.56%. This method can be applied to the further pharmacokinetic study of levonorgestrel and quinestrol in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
Sensitive and reproducible methods for the determination of oxycodone, oxymorphone and noroxycodone in Ringer solution, rat plasma and rat brain tissue by liquid chromatography/mass spectrometry are described. Deuterated analogs of the substances were used as internal standards. Samples in Ringer solution were analyzed by direct injection of 10 microL Ringer solution diluted by an equal volume of water. The limit of quantification was 0.5 ng/mL and the method was linear in the range of 0.5-150 ng/mL for all substances. To analyze oxycodone and oxymorphone in rat plasma, 50 microL of plasma were precipitated with acetonitrile, and the supernatant was directly injected onto the column. To analyze oxycodone, oxymorphone and noroxycodone in rat plasma, 100 microL of rat plasma were subjected to a C18 solid-phase extraction (SPE) procedure, before reconstituting in mobile phase and injection onto the column. For both methods the limit of quantification in rat plasma was 0.5 ng/mL and the methods were linear in the range of 0.5-250 ng/mL for all substances. To analyze the content of oxycodone, oxymorphone and noroxycodone in rat brain tissue, 100 microL of the brain homogenate supernatant were subjected to a C18 SPE procedure. The limit of quantification of oxycodone was 20 ng/g brain, and for oxymorphone and noroxycodone 4 ng/g brain, and the method was linear in the range of 20-1000 ng/g brain for oxycodone and 4-1000 ng/g brain for oxymorphone and noroxycodone. All methods utilized a mobile phase of 5 mM ammonium acetate in 45% acetonitrile, and a SB-CN column was used for separation. The total run time of all methods was 9 min. The intra-day precision and accuracy were <11.3% and <+/-14.9%, respectively, and the inter-day precision and accuracy were <14.9% and <+/-6.5%, respectively, for all the concentrations and matrices described.  相似文献   

13.
Li H  He J  Liu Q  Huo Z  Liang S  Liang Y  Ito Y 《Chromatographia》2011,73(1-2):171-175
A simple, selective and sensitive reversed-phase high performance liquid chromatography method for simultaneous analysis of hydrochlorothiazide and reserpine in human urine was developed and subjected to primary pharmacokinetic study. After a simple protein precipitation using methanol and extraction with ethyl acetate, the analytes were separated on an Elite C(18) column at a flow rate of 0.8 mL min(-1). The mobile phase was composed of acetonitrile (A) and 0.2% ammonium chloride solution (B) for a gradient elution starting at A:B at 30:70, v/v for 0~6 min, linearly raising the percent of A from 30% to 50% (6~9 min) and ending at 50:50, v/v (9~25 min). The standard curves were linear over the range of 0.05-20 μg mL(-1) for hydrochlorothiazide and 0.02-5.0 μg mL(-1) for reserpine, respectively (r > 0.999). The limit of detection (LOD) and the limit of quantification (LOQ) were 5.5 ng mL(-1) and 18.2 ng mL(-1) for hydrochlorothiazide, and 7.1 ng mL(-1) and 23.6 ng mL(-1) for reserpine, respectively. The recoveries for both analytes were above 89.0±1.35%. The intra-day and inter-day precision for hydrochlorothiazide were less than 1.91% and 1.38%, and those for reserpine were below 1.61% and 2.64%, respectively. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy, and it was employed successfully for the simultaneous determination of hydrochlorothiazide and reserpine in human urine samples.  相似文献   

14.
A simple and efficient method based on cloud-point extraction combined with high-performance liquid chromatography was developed and validated for the determination of larotaxel in rat plasma. Nonionic surfactant Triton X-114 was chosen as the extraction solvent. Variable parameters affecting the cloud-point extraction efficiency, for example the nature and concentration of surfactant, NaOH concentration, incubation temperature, and time were evaluated and optimized. Chromatographic separation was accomplished on a Diamonsil C(18) column (150 mm × 4.6 mm, 5 μm) using a mobile phase consisting of acetonitrile and 0.1% phosphoric acid with pH 4.0 (60:40, v/v). The calibration curve showed good linearity over the range of 0.05-10 μg/mL. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 5.7%, interday precision below 7.2%, accuracy within ±3.5%, and mean extraction recovery of 91.8-94.2%. The validated method was successfully applied to the pharmacokinetic study of larotaxel in rat plasma after a single intravenous administration of larotaxel injection and larotaxel-loaded liposome, respectively. The results indicated that the larotaxel-loaded liposome led to significant differences in pharmacokinetic profile.  相似文献   

15.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LCESI-MS/MS) method with low matrix effects was developed and validated for the quantification of the lipophilic antipsychotic ziprasidone from rat plasma and brain tissue. Ziprasidone was extracted from rat plasma and brain homogenate using a single-step liquid-liquid extraction. Ziprasidone was separated on an Agilent Eclipse XDB C8 column (150 x 2.1 mm i.d., 5 microm) column using a mobile phase of acetonitrile-0.02% ammonia in water (pH 7.20 adjusted with formic acid) using gradient elution. Ziprasidone was detected in the positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recovery, matrix effects and stability were determined. The LLOQ was 0.2 ng/mL for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/mL for plasma and 0.833-833.3 ng/g for brain tissue. The correlation coefficient (R2) values were more than 0.996 for both plasma and brain homogenate. The precision and accuracy intra-day and inter-day were better than 8.13%. The relative and absolute recovery was above 81.0% and matrix effects were lower than 5.2%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of ziprasidone after chronic treatment.  相似文献   

16.
A simple RP-HPLC method was established for the determination of salidroside in dog plasma. Salidroside is one of the most active ingredients of Rhodiola L. The method had within-run precision values in the range of +/- 2.3 to +/- 9.1% (n = 5) and between-run precision in the range of +/- 3.2 to +/- 9.8%. A simple protein precipitation for salidroside extraction was processed using ACN at precipitant-to-plasma volume ratio (P-P ratio) of 3:2. The extraction recoveries of salidroside at seven concentrations were higher than 63.2%. There was a linear relationship between chromatographic area and concentration over the range of 0.83-520 microg/mL for salidroside in plasma (R = 0.9926). The LOQ (S/N = 10) of the method was 0.83 microg/mL. The method was applied in a study of the pharmacokinetics of salidroside injection in six beagle dogs. The major pharmacokinetic parameters of C(max), AUC(0-24), AUC(0-infinity), and t(1/2) of salidroside in beagle dogs after i.v. administration of a single 75 mg/kg (5 mL/kg) dose were 96.16 +/- 8.59 microg/mL, 180.3 +/- 30.6 microg h/mL, 189.3 +/- 32.1 microg h/mL, and 2.006 +/- 0.615 h, respectively.  相似文献   

17.
The objective of the current study was to develop and validate a simple, precise and accurate isocratic stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) assay method for the determination of spironolactone and furosemide in solid pharmaceutical dosage forms. Isocratic RP-HPLC separation was achieved on an SGE 150 × 4.6 mm SS Wakosil II 5C8RS 5-μm column using a mobile phase of acetonitrile-ammonium acetate buffer (50:50, v/v) at a flow rate of 1.0 mL/min. The detection was carried out at 254 nm using a photodiode array detector. The drug was subject to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and solution stability. The method was found to be linear in the drug concentration range of 40-160 μg/mL with correlation coefficients of 0.9977 and 0.9953 for spironolactone and furosemide, respectively. The precision (relative standard deviation; RSD) among a six-sample preparation was 0.87% and 1.1% for spironolactone and furosemide, respectively. Repeatability and intermediate precision (RSD) among a six-sample preparation were 0.46% and 0.20% for spironolactone and furosemide, respectively. The accuracy (recovery) was between 98.05 and 100.17% and 99.07 and 100.58% for spironolactone and furosemide, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of spironolactone and furosemide; therefore, the assay can be considered to be stability-indicating.  相似文献   

18.
林强  杨超  李美丽  王佳  侯瀚然  邵兵  牛宇敏 《色谱》2023,41(3):274-280
人体生物基质中麻痹性贝类毒素的检测对其引起的食物中毒诊断和救治具有重要意义。研究建立了超高效液相色谱-串联质谱法测定血浆、尿液中14种麻痹性贝类毒素的分析方法。实验比较了不同固相萃取柱的影响,优化了前处理条件和色谱条件,血浆样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取后直接上机测定,尿液样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取,聚酰胺(PA)固相萃取柱净化后上机测定。采用Poroshell 120 HILIC-Z色谱柱(100 mm×2.1 mm,2.7μm)对14种贝类毒素进行分离,流动相为含0.1%(v/v)甲酸的5 mmoL/L甲酸铵缓冲溶液和0.1%(v/v)甲酸乙腈溶液,流速为0.50 mL/min。在电喷雾模式(ESI)下进行正负离子扫描,采用多反应监测(MRM)模式检测,外标法定量。结果表明,对于血浆和尿液样品,14种贝类毒素分别在0.24~84.06 ng/mL范围内线性关系良好,相关系数均大于0.995。尿液检测的定量限为4.80~34.40 ng/mL,血浆检测的定量限为1.68~12.04 ng/mL。尿液和血浆样品在1、2和10倍定量限加标水平下平均回收率为70.4%~123.4%,日内精密度为2.3%~19.1%,日间精密度为4.0%~16.2%。应用建立的方法对腹腔注射14种贝类毒素小鼠血浆和尿液进行测定,20份血浆样本中检出含量分别为19.40~55.60μg/L和8.75~13.86μg/L。该方法操作简便,样品取样量少,方法灵敏度高,适用于血浆和尿液中麻痹性贝类毒素的快速检测。  相似文献   

19.
Dimethylacetamide (DMA) is a solvent used in the preparation of intravenous busulfan, an alkylating agent used in blood or marrow transplantation. DMA may contribute to hepatic toxicity, so it is important to monitor its clearance. The aim of this study was to develop an HPLC‐UV assay for measurement of DMA in human plasma. After precipitation of plasma proteins with acetonitrile followed by dilution (1:4) with water, the extract was injected onto the HPLC and detected at 195 nm. Separation was performed using a Cogent‐HPS 5 μm C18 column (250 × 4.6 mm) preceded by a Brownlee 7 μm RP18, pre‐column (1.5 cm × 3.2 mm). The mobile phase was 25 mm sodium phosphate buffer (pH 3), containing 2.5% (v /v) acetonitrile and 0.0005% (v /v) sodium‐octyl‐sulfonate. Using a flow rate of 1 mL/min, the retention times of DMA and the internal standard (IS), 2‐chloroacetamide, were 9.5 and 3.5 min, respectively. Peak area ratio (DMA:IS) was a linear function of concentration from 1 to 1000 μg/mL. There was excellent intraday precision (<5% for 5–700 μg/mL DMA), accuracy (<3% deviation from the true concentration) and recovery (74–98%). The limits of detection and quantification were 1 and 5 μg/mL, respectively. In eight children who received intravenous busulfan, DMA concentrations ranged from 110 to 438 μg/mL.  相似文献   

20.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号