首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Development of an LC-MALDI method for the analysis of protein complexes   总被引:4,自引:0,他引:4  
In this study, a two-dimensional LC-MALDI-TOF/TOF method has been developed for analyzing protein complexes. In our hands, the method has proven to be an excellent strategy for the analysis of protein complexes isolated in pull-down experiments. This is in part because the preservation of the chromatographic separation on a MALDI target yields an "unlimited" amount of time to obtain MS/MS spectra, making it possible to probe more deeply into complex samples. A brief statistical analysis was performed on the data obtained from the LC-MALDI-TOF/TOF system in order to better understand peptide fragmentation patterns under high-energy collision conditions. These statistical analyses provided some insight into how to evaluate the quality and accuracy of the database search results derived from the TOF/TOF-based analysis. The potential of the method was demonstrated by the successful identification of all the known penicillin-binding proteins in E. coli isolated using a drug-based pull-down with ampicillin as the bait. The performance of the LC-MALDI-TOF/TOF system was compared with that of an equivalent 2D LC-ESI-MS/MS approach, in the analysis of a protein bait-based pull-down. Regardless of the number of peptides identified in the ESI versus MALDI approach, the two approaches were found to be complementary. When the data is merged at the peptide level, the combined result gives higher Mascot scores and an overall higher confidence in protein identification than with either approach alone.  相似文献   

2.
Highly complex protein mixtures can be analyzed after proteolysis using liquid chromatography/mass spectrometry (LC/MS). In an LC/MS run, intense peptide ions originating from high-abundance proteins are preferentially analyzed using tandem mass spectrometry (MS(2)), so obtaining the MS(2) spectra of peptide ions from low-abundance proteins is difficult even if such ions are detected. Furthermore, the MS(2) spectra may produce insufficient information to identify the peptides or proteins. To solve these problems, we have developed a real-time optimization technique for MS(2), called the Information-Based-Acquisition (IBA) system. In a preliminary LC/MS run, a few of the most intense ions detected in every MS spectrum are selected as precursors for MS(2) and their masses, charge states and retention times are automatically registered in an internal database. In the next run, a sample similar to that used in the first run is analyzed using database searching. Then, the ions registered in the database are excluded from the precursor ion selection to avoid duplicate MS(2) analyses. Furthermore, real-time de novo sequencing is performed just after obtaining the MS(2) spectrum, and an MS(3) spectrum is obtained for accurate peptide identification when the number of interpreted amino acids in the MS(2) spectrum is less than five. We applied the IBA system to a yeast cell lysate which is a typical crude sample, using a nanoLC/ion-trap time-of flight (IT/TOF) mass spectrometer, repeating the same LC/MS run five times. The obtained MS(2) and MS(3) spectra were analyzed by applying the Mascot (Matrix Science, Boston, MA, USA) search engine to identify proteins from the sequence database. The total number of identified proteins in five LC/MS runs was three times higher than that in the first run and the ion scores for peptide identification also significantly increased, by about 70%, when the MS(3) spectra were used, combined with the MS(2) spectra, before being subjected to Mascot analysis.  相似文献   

3.
Simple and efficient digestion of proteins, particularly hydrophobic membrane proteins, is of significance for comprehensive proteome analysis using the bottom-up approach. We report a microwave-assisted acid hydrolysis (MAAH) method for rapid protein degradation for peptide mass mapping and tandem mass spectrometric analysis of peptides for protein identification. It uses 25% trifluoroacetic acid (TFA) aqueous solution to dissolve or suspend proteins, followed by microwave irradiation for 10 min. This detergent-free method generates peptide mixtures that can be directly analyzed by liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) without the need of extensive sample cleanup. LC-MALDI MS/MS analysis of the hydrolysate from 5 microg of a model transmembrane protein, bacteriorhodopsin, resulted in almost complete sequence coverage by the peptides detected, including the identification of two posttranslational modification sites. Cleavage of peptide bonds inside all seven transmembrane domains took place, generating peptides of sizes amenable to MS/MS to determine possible sequence errors or modifications within these domains. Cleavage specificity, such as glycine residue cleavage, was observed. Terminal peptides were found to be present in relatively high abundance in the hydrolysate, particularly when low concentrations of proteins were used for MAAH. It was shown that these peptides could still be detected from MAAH of bacteriorhodopsin at a protein concentration of 1 ng/microl or 37 fmol/microl. To evaluate the general applicability of this method, it was applied to identify proteins from a membrane protein enriched fraction of cell lysates of human breast cancer cell line MCF7. With one-dimensional LC-MALDI MS/MS, a total of 119 proteins, including 41 membrane-associated or membrane proteins containing one to 12 transmembrane domains, were identified by MS/MS database searching based on matches of at least two peptides to a protein.  相似文献   

4.
Peptide retention time (RT) is independent of tandem mass spectrometry (MS/MS) parameters and can be combined with MS/MS information to enhance peptide identification. In this paper, we utilized peptide empirical RT and MS/MS for peptide identification. This new approach resulted in the construction of an Empirical Peptide Retention Time Database (EPRTD) based on peptides showing a false‐positive rate (FPR) ≤1%, detected in several liquid chromatography (LC)/MS/MS analyses. In subsequent experiments, the RT of peptides with FPR >1% was compared with empirical data derived from the EPRTD. If the experimental RT was within a specified time range of the empirical value, the corresponding MS/MS spectra were accepted as positive. Application of the EPRTD approach to simple samples (known protein mixtures) and complex samples (human urinary proteome) revealed that this method could significantly enhance peptide identification without compromising the associated confidence levels. Further analysis indicated that the EPRTD approach could improve low‐abundance peptides and with the expansion of the EPRTD the number of peptide identifications will be increased. This approach is suitable for large‐scale clinical proteomics research, in which tens of LC/MS/MS analyses are run for different samples with similar components. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
Desorption electrospray ionization mass spectrometry (DESI-MS) was demonstrated as a method to detect and identify peptides from two-dimensional separations of cytochrome c and myoglobin tryptic digests on ProteoChrom HPTLC Cellulose sheets. Data-dependent tandem mass spectra were acquired during lane scans across the TLC plates. Peptides and the corresponding proteins were identified using a protein database search software. Two-dimensional distributions of identified peptides were mapped for each separated protein digest. Sequence coverages for cytochrome c and myoglobin were 81 and 74%, respectively. These compared well with those determined using the more standard HPLC/ESI-MS/MS approach (89 and 84%, respectively). Preliminary results show that use of more sensitive instrumentation has the potential for improved detection of peptides with low R(f) values and improvement in sequence coverage. However, less multiple charging and more sodiation were seen in HPTLC/DESI-MS spectra relative to HPLC/ESI-MS spectra, which can affect peptide identification by MS/MS. Methods to increase multiple charging and reduce the extent of sodiation are currently under investigation.  相似文献   

6.
The identification of glycosylation sites in proteins is often possible through a combination of proteolytic digestion, separation, mass spectrometry (MS) and tandem MS (MS/MS). Liquid chromatography (LC) in combination with MS/MS has been a reliable method for detecting glycopeptides in digestion mixtures, and for assigning glycosylation sites and glycopeptide sequences. Direct interfacing of LC with MS relies on electrospray ionization, which produces ions with two, three or four charges for most proteolytic peptides and glycopeptides. MS/MS spectra of such glycopeptide ions often lead to ambiguous interpretation if deconvolution to the singly charged level is not used. In contrast, the matrix-assisted laser desorption/ionization (MALDI) technique usually produces singly charged peptide and glycopeptide ions. These ions require an extended m/z range, as provided by the quadrupole-quadrupole time-of-flight (QqTOF) instrument used in these experiments, but the main advantages of studying singly charged ions are the simplicity and consistency of the MS/MS spectra. A first aim of the present study is to develop methods to recognize and use glycopeptide [M+H]+ ions as precursors for MS/MS, and thus for glycopeptide/glycoprotein identification as part of wider proteomics studies. Secondly, this article aims at demonstrating the usefulness of MALDI-MS/MS spectra of N-glycopeptides. Mixtures of diverse types of proteins, obtained commercially, were prepared and subjected to reduction, alkylation and tryptic digestion. Micro-column reversed-phase separation allowed deposition of several fractions on MALDI plates, followed by MS and MS/MS analysis of all peptides. Glycopeptide fractions were identified after MS by their specific m/z spacing patterns (162, 203, 291 u) between glycoforms, and then analyzed by MS/MS. In most cases, MS/MS spectra of [M+H]+ ions of glycopeptides featured peaks useful for determining sugar composition, peptide sequence, and thus probable glycosylation site. Peptide-related product ions could be used in database search procedures and allowed the identification of the glycoproteins.  相似文献   

7.
An algorithm for interpretation of product ion spectra of peptides generated from ion trap mass spectrometry is developed for de novo amino acid sequencing of peptides for the purpose of protein identification. It is based on a multi-pass analysis of product ion data using a rigorous data extraction and sequence interpretation protocol in the initial pass. The extraction/interpretation algorithm becomes more relaxed in subsequent passes, considering more of the fragment ions, and potentially more sequence candidates. The possible peptide sequences generated by the algorithm are scored according to those sequences which best explain the fragment ion spectrum. These sequences are searched against a protein database using a BLAST search engine to find likely protein candidates. The method is also suitable for locating and determining protein modifications, and can be applied to de novo interpretation of peptide fragment ions in the tandem mass (MS/MS) spectrum produced from a mixture of two peptides having similar nominal mass, but different sequences. Using a known protein, bovine serum albumin, as an example, it is illustrated that this method is rapid and efficient for MS/MS spectral interpretation. This method combined with BLAST programs is then applied to search homologies and to generate information on post-translational modifications of an unknown protein isolated from shark cartilage that does not have a complete genome or proteome database.  相似文献   

8.
Mass spectrometry based proteomic experiments have advanced considerably over the past decade with high-resolution and mass accuracy tandem mass spectrometry (MS/MS) capabilities now allowing routine interrogation of large peptides and proteins. Often a major bottleneck to 'top-down' proteomics, however, is the ability to identify and characterize the complex peptides or proteins based on the acquired high-resolution MS/MS spectra. For biological samples containing proteins with multiple unpredicted processing events, unsupervised identifications can be particularly challenging. Described here is a newly created search algorithm (MAR) designed for the identification of experimentally detected peptides or proteins. This algorithm relies only on predefined list of 'differential' modifications (e.g. phosphorylation) and a FASTA-formatted protein database, and is not constrained to full-length proteins for identification. The algorithm is further powered by the ability to leverage identified mass differences between chromatographically separated ions within full-scan MS spectra to automatically generate a list of likely 'differential' modifications to be searched. The utility of the algorithm is demonstrated with the identification of 54 unique polypeptides from human apolipoprotein enriched from the high-density lipoprotein particle (HDL), and searching time benchmarks demonstrate scalability (12 high-resolution MS/MS scans searched per minute with modifications considered). This parallelizable algorithm provides an additional solution for converting high-quality MS/MS data of multiply processed proteins into reliable identifications.  相似文献   

9.
A simple and effective method was developed for peptide sequencing and protein identification through the determination of its N-terminal residue. The method of N-terminal carbamidomethylation with iodoacetamide could specifically and remarkably enhance the intensity of a1 ions in the tandem mass spectra of the peptide derivatives without significantly altering their fragmentation pattern, thus allowing determination of their N-terminal residues. The effectiveness and specificity of the method was demonstrated by confirming and extending sequence interpretation of several model peptides and proteins. The developed method was then applied in the LC-MS/MS analysis of the tryptic digests of myoglobin and a whole protein extract from rat heart tissues. The results from database searches were well validated with the enhancement of a1 ions in tandem mass spectra and the specificity of protein identification was obtained when the information of N-terminal residues was included in the database search.  相似文献   

10.
Liquid chromatography (LC) electron transfer dissociation (ETD) tandem mass spectrometry (MS/MS) of protein digests is demonstrated in a hybrid quadrupole‐hexapole orthogonal time‐of‐flight (OTOF) mass spectrometer. Analyte ions are selected in a mass‐analyzing quadrupole, accumulated in the hexapole linear ETD reaction cell and mutually stored with ETD reagent anions. Product ions are collected in an ion cooler and then analyzed by an OTOF mass analyzer. The hexapole structure of the ETD reaction cell allows for a broad fragment ion mass range distribution and a high ion storage capacity. Analytically useful ETD OTOF‐MS/MS spectra could be obtained at a rate of faster than 2 Hz. When used in conjunction with LC this high speed allows for several MS and MS/MS spectra to be obtained across each LC peak. An MS scan is used to select the precursor ions. With a 1 m flight tube and single reflection, resolutions of about 10 k and a mass accuracy of 5 ppm were achieved. When analyzing a 100 fmol solution of a tryptic digest of bovine serum albumin (BSA) by LC/ETD MS/MS, 27 unique peptides were identified with a summed Mascot score of 1316 using the Swiss Prot database. In addition, we explored the capability for analyzing small proteins with the present hybrid instrument. ETD MS/MS of intact ubiquitin ([M+12H]12+) leads to the identification of the protein with a Mascot score of 264. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The development of novel proteomic technologies that will enable the discovery of disease specific biomarkers is essential in the clinical setting to facilitate early diagnosis and increase survivability rates. We are reporting a shotgun two-dimensional (2D) strong cationic exchange/reversed-phase liquid chromatography/electrospray ionization tandem mass spectrometry (SCX/RPLC/ESI-MS/MS) protocol for the analysis of proteomic constituents in cancerous cells. The MCF7 breast cancer cell line was chosen as a model system. A series of optimization steps were performed to improve the LC/MS experimental setup, sample preparation, data acquisition and database search protocols, and a data filtering strategy was developed to enable confident identification of a large number of proteins and potential biomarkers. This research has resulted in the identification of >2000 proteins using multiple filtering and p-value sorting. Approximately 1600-1900 proteins had p < 0.001, and, of these, approximately 60% were matched by >or=2 unique peptides. Alternatively, >99% of the proteins identified by >or=2 unique peptides had p < 0.001. When searching the data against a reversed database of proteins, the rate of false positive identifications was 0.1% at the peptide level and 0.4% at the protein level. The typical reproducibility in detecting overlapping proteins across replicate runs exceeded 90% for proteins matched by >or=2 unique peptides. According to their biological function, approximately 200 proteins were involved in cancer-relevant cellular processes, and over 25 proteins were previously described in the literature as putative cancer biomarkers, as they were found to be differentially expressed between normal and cancerous cell states. Among these, biomarkers such PCNA, cathepsin D, E-cadherin, 14-3-3-sigma, antigen Ki-67, TP53RK, and calreticulin were identified. These data were generated by subjecting to MS analysis approximately 42 microg of sample, analyzing 16 SCX peptide fractions, and interpreting approximately 55,000 MS2 spectra. Total MS time required for analysis was 40 h.  相似文献   

12.
Dysregulation of proteolytic processing of the amyloid precursor protein (APP) contributes to the pathogenesis of Alzheimer's Disease, and the Group VIA phospholipase A(2) (iPLA(2)beta) is the dominant PLA(2) enzyme in the central nervous system and is subject to regulatory proteolytic processing. We have identified novel N-terminal variants of iPLA(2)beta and previously unrecognized proteolysis sites in APP constructs with a C-terminal 6-myc tag by automated identification of signature peptides in LC/MS/MS analyses of proteolytic digests. We have developed a Signature-Discovery (SD) program to characterize protein isoforms by identifying signature peptides that arise from proteolytic processing in vivo. This program analyzes MS/MS data from LC analyses of proteolytic digests of protein mixtures that can include incompletely resolved components in biological samples. This reduces requirements for purification and thereby minimizes artifactual modifications during sample processing. A new algorithm to generate the theoretical signature peptide set and to calculate similarity scores between predicted and observed mass spectra has been tested and optimized with model proteins. The program has been applied to the identification of variants of proteins of biological interest, including APP cleavage products and iPLA(2)beta, and such applications demonstrate the utility of this approach.  相似文献   

13.
A database search using peptide mass fingerprints obtained by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry leads to protein identification with incomplete sequence coverage, because certain peptides are preferentially desorbed/ionized and some are not detected at all. We show that certain tryptic peptides mainly with C-terminal arginine not detected before derivatization become detectable upon dansylation. Others, mainly with C-terminal lysine, are suppressed. An increase in protein sequence coverage and protein identification score by combined data from underivatized and dansylated peptides in database search is demonstrated using human amnion proteins (human serum albumin precursor, calmodulin, collagen alpha 2(VI) chain precursor, galectin-3) separated by two-dimensional gel electrophoresis as well as femtomole amounts of BSA in solution.  相似文献   

14.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

15.
Ricin is a glycosylated proteinous toxin that is registered as toxic substance by Chemical Weapons convention. Current detection methods can result in false negatives and/or positives, and their criteria are not based on the identification of the protein amino acid sequences. In this study, lactose-immobilized monolithic silica extraction followed by tryptic digestion and liquid chromatography/mass spectrometry (LC/MS) was developed as a method for rapid and accurate determination of ricin. Lactose, which was immobilized on monolithic silica, was used as a capture ligand for ricin extraction from the sample solution, and the silica was supported in a disk-packed spin column. Recovery of ricin was more than 40%. After extraction, the extract was digested with trypsin and analyzed by LC/MS. The accurate masses of molecular ions and MS/MS spectra of the separated peptide peaks were measured by Fourier transform-MS and linear iontrap-MS, respectively. Six peptides, which were derived from the ricin A-(m/z 537.8, 448.8 and 586.8) and B-chains (m/z 701.3, 647.8 and 616.8), were chosen as marker peptides for the identification of ricin. Among these marker peptides, two peptides were ricin-specific. This method was applied to the determination of ricin from crude samples. The monolithic silica extraction removed most contaminant peaks from the total ion chromatogram of the sample, and the six marker peptides were clearly detected by LC/MS. It takes about 5 h for detection and identification of more than 8 ng/ml of ricin through the whole handling, and this procedure will be able to deal with the terrorism using chemical weapon.  相似文献   

16.
The identification of proteins differentially expressed between cancer and normal cells is vital for the development of cancer diagnostics, therapeutics and vaccines. Using a ProteinChip Biomarker System (Ciphergen Biosystems, Fremont, CA) which combines ProteinChip technology with time-of-flight mass spectrometry, we have developed a simple method to screen and identify differentially secreted proteins from tumor cell lines. Mass spectra of the range of proteins secreted from normal B-cells were generated along with those secreted from Epstein-Barr virus transformed B-cells. A mass peak at m/z = 4972.1 that was highly over-represented in the transformed B-cell line was chosen for identification and purified by reversed phase chromatography with concomitant monitoring of fractions by SELDI-TOF MS. The resulting purified protein was digested with trypsin and the peptide masses derived from the SELDI-TOF spectrum were used to search the public databases for protein identification. Fragment matching of the resulting peptides identified the protein as thymosin beta-4. Using LC-electrospray ionization MS/MS, the identity of this protein was confirmed. Thymosin beta-4 is a known marker in LCLs establishing the utility of this method to discover and identify proteins differentially expressed between cancers and their matched normal counterparts.  相似文献   

17.
Qscore: An algorithm for evaluating SEQUEST database search results   总被引:12,自引:0,他引:12  
A scoring procedure is described for measuring the quality of the results for protein identifications obtained from spectral matching of MS/MS data using the Sequest database search program. The scoring system is essentially probabilistic and operates by estimating the probability that a protein identification has come about by chance. The probability is based on the number of identified peptides from the protein, the total number of identified peptides, and the fraction of distinct tryptic peptides from the database that are present in the identified protein. The score is not strictly a probability, as it also incorporates information about the quality of the individual peptide matches. The result of using Qscore on a large test set of data was similar to that achieved using approaches that validate individual spectral matches, with only a narrow overlap in scores between identified proteins and false positive matches. In direct comparison with a published method of evaluating Sequest results, Qscore was able to identify an equivalent number of proteins without any identifiable false positive assignments. Qscore greatly reduces the number of Sequest protein identifications that have to be validated manually.  相似文献   

18.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

19.
We developed an efficient and convenient strategy for protein identification and glycosylation analysis of a small amount of unknown glycoprotein in a biological sample. The procedure involves isolation of proteins by electrophoresis and mass spectrometric peptide/glycopeptide mapping by LC/ion trap mass spectrometer. For the complete glycosylation analysis, proteins were extracted in intact form from the gel, and proteinase-digested glycoproteins were then subjected to LC/multistage tandem MS (MSn) incorporating a full mass scan, in-source collision-induced dissociation (CID), and data-dependent MSn. The glycopeptides were localized in the peptide/glycopeptide map by using oxonium ions such as HexNAc+ and NeuAc+, generated by in-source CID, and neutral loss by CID-MS/MS. We conducted the search analysis for the glycopeptide identification using search parameters containing a possible glycosylation at the Asn residue with N-acetylglucosamine (203 Da). We were able to identify the glycopeptides resulting from predictable digestion with proteinase. The glycopeptides caused by irregular cleavages were not identified by the database search analysis, but their elution positions were localized using oxonium ions produced by in-source CID, and neutral loss by the data-dependent MSn. Then, all glycopeptides could be identified based on the product ion spectra which were sorted from data-dependent CID-MSn spectra acquired around localized positions. Using this strategy, we successfully elucidated site-specific glycosylation of Thy-1, glycosylphosphatidylinositol (GPI)-anchored proteins glycosylated at Asn23, 74, and 98, and at Cys111. High-mannose-type, complex-type, and hybrid-type oligosaccharides were all found to be attached to Asn23, 74 and 98, and four GPI structures could be characterized. Our method is simple, rapid and useful for the characterization of unknown glycoproteins in a complex mixture of proteins.  相似文献   

20.
This paper describes an algorithm to apply proteotypic peptide sequence libraries to protein identifications performed using tandem mass spectrometry (MS/MS). Proteotypic peptides are those peptides in a protein sequence that are most likely to be confidently observed by current MS-based proteomics methods. Libraries of proteotypic peptide sequences were compiled from the Global Proteome Machine Database for Homo sapiens and Saccharomyces cerevisiae model species proteomes. These libraries were used to scan through collections of tandem mass spectra to discover which proteins were represented by the data sets, followed by detailed analysis of the spectra with the full protein sequences corresponding to the discovered proteotypic peptides. This algorithm (Proteotypic Peptide Profiling, or P3) resulted in sequence-to-spectrum matches comparable to those obtained by conventional protein identification algorithms using only full protein sequences, with a 20-fold reduction in the time required to perform the identification calculations. The proteotypic peptide libraries, the open source code for the implementation of the search algorithm and a website for using the software have been made freely available. Approximately 4% of the residues in the H. sapiens proteome were required in the proteotypic peptide library to successfully identify proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号