首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
The nicotine metabolites, cotinine and trans-3′-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers’ urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.
Figure
Scheme of the procedure for detection of cotinine and 3HC  相似文献   

2.
The use of nanoparticles (NPs) can substantially improve the analytical performance of surface plasmon resonance imaging (SPRi) in general, and in DNA sensing in particular. In this work, we report on the modification of the gold surface of commercial biochips with gold nanospheres, silica-coated gold nanoshells, and silver nanoprisms, respectively. The NPs were tethered onto the surface of the chip and functionalized with a DNA probe. The effects of tethering conditions and varying nanostructures on the SPRi signals were evaluated via hybridization assays. The results showed that coupling between planar surface plasmons and electric fields, generated by localized surface plasmons of the NPs, is mandatory for signal enhancement. Silver nanoprisms gave the best results in improving the signal change at a target DNA concentration of <50 nM by +50 % (compared to a conventional SPRi chip). The limit of detection for the target DNA was 0.5 nM which is 5 times less than in conventional SPRi.
Figure
?  相似文献   

3.
We have developed a surface-enhanced Raman scattering (SERS) probe for the determination of mercury(II) using methimazole-functionalized and cyclodextrin-coated silver nanoparticles (AgNPs). These AgNPs in pH 10 solution containing sodium chloride exhibit strong SERS at 502 cm?1. Its intensity strongly decreases in the presence of Hg(II). This effect serves as the basis for a new method for the rapid, fast and selective determination of trace Hg(II). The analytical range is from 0.50 μg L?1 to 150 μg L?1, and the limit of detection is 0.10 μg L?1. The influence of 11 metal ions commonly encountered in environmental water samples was found to be quite small. The method was applied to the determination of Hg(II) in spiked water samples and gave recoveries ranging from 98.5 to 105.2 % and with relative standard deviations of <3.5 % (n?=?5). The total analysis time is <10 min for a single sample.
Figure
A high-sensitive SERS probe for the determination of Hg2+ using methimazole-functionalized cyclodextrin-protected AgNPs was designed. The limit of detection is 0.10 μg L?1.  相似文献   

4.
A selective aptameric sequence is adsorbed on a two-dimensional nanostructured metallic platform optimized for surface-enhanced Raman spectroscopy (SERS) measurements. Using nanofabrication methods, a metallic nanostructure was prepared by electron-beam lithography onto a glass coverslip surface and embedded within a microfluidic channel made of polydimethylsiloxane, allowing one to monitor in situ SERS fingerprint spectra from the adsorbed molecules on the metallic nanostructures. The gold structure was designed so that its localized surface plasmon resonance matches the excitation wavelength used for the Raman measurement. This optofluidic device is then used to detect the presence of a toxin, namely ochratoxin-A (OTA), in a confined environment, using very small amounts of chemicals, and short data acquisition times, by taking advantage of the optical properties of a SERS platform to magnify the Raman signals of the aptameric monolayer system and avoiding chemical labeling of the aptamer or the OTA target.
Fig
Aptamer detection of OTA within a SERS/microfluidic channel  相似文献   

5.
Water–soluble fluorescent silver nanoclusters (Ag NCs) were prepared with the assistance of commercially available polyinosinic acid (PI) or polycytidylic acid (PC). The fluorescence of the Ag NCs is effectively quenched by trace mercury(II) ions, which can be applied for their detection. The response of the Ag NCs prepared with PI to Hg(II) ion is linear in the Hg(II) concentration range from 0.05 to 1.0 μM (R2?=?0.9873), and from 0.5 to 10 μM of Hg(II) (R2?=?0.9971) for Ag NCs prepared with PC. The detection limits are 3.0 nM and 9.0 nM (at an S/N of 3), respectively. The method is simple, sensitive and fairly selective.
Figure
Water-soluble fluorescent Ag nanoclusters (NCs) were facilely prepared using commercially available polyinosinic acid or polycytidylic acid. The fluorescence intensity of the as-prepared Ag NCs was effectively quenched by trace Hg2+, which was used for the detection of Hg2+ in water samples with good performance.  相似文献   

6.
A glassy carbon electrode (GCE) was modified with pyrocatechol violet (PCV) that was electrodeposited on single walled carbon nanotubes (SWCNTs) via continuous cycling between 0 and 0.9 V (vs. SCE). The resulting electrode exhibits excellent electrocatalytic activity towards the oxidation of hydrazine at 0.3 V. The apparent surface coverage of the electrode is at least 24 times higher (2.7?×?10?10 mol cm?2) than that obtained with a bare GCE (1.1?×?10?11 mol cm?2). This is attributed to a remarkably strong synergistic effect between the acid-pretreated SWCNTs and the electrodeposited PCV coating. Response is fast (2 s) and sensitive (281 mA M?1 cm?2). Other features include a wide linear range (150 nM to 0.4 mM) and a low detection limit (150 nM at an SNR of 3). The sensor has been successfully applied to the determination of hydrazine in water and cigarette samples with good accuracy and precision. In addition, the morphology and the wetting properties of the coating were studied by scanning electromicroscopy and contact angle measurements.
Figure
A glassy carbon electrode (GCE) was modified with pyrocatechol violet (PCV) that was electrodeposited on single walled carbon nanotubes (SWCNTs). The resulting electrode exhibits excellent electrocatalytic activity towards the oxidation of hydrazine at 0.3 V with fast response, wide linear range and a low detection limit.  相似文献   

7.
We report on an electrode for the amperometric determination of lorazepam. A glassy carbon electrode was coated with a molecular imprint made by electropolymerization of ortho-phenylenediamine and filled with multiwalled carbon nanotubes and gold nanoparticles, which enhances the transmission of electrons. The sensor was studied with respect to its response to hexacyanoferrate (III) as a probe and by electrochemical impedance spectroscopy, cyclic voltammetry and square wave voltammetry. The linear response range to Lorazepam is from 0.5 nM to 1.0 nM and from 1.0 nM to 10.0 nM, with a detection limit of 0.2 nM (at an S/N of 3). The electrode was successfully applied to determine Lorazepam in spiked human serum.
Figure 1
The preparation of schematic of the AuNP/MIP/f?MWCNT/GCE electrode  相似文献   

8.
《Analytical letters》2012,45(16):2682-2690
This paper describes the development of a portable microfluidic chip based on a surface-enhanced Raman spectroscopy (SERS) sensor for crystal violet analysis. A Y-shape microfluidic chip with a staggered herringbone structure was designed to efficiently mix the analyte and SERS active silver colloid. The subsequent detection of the analyte was performed on the microfluidic chip by a portable Raman system. Compared with other methods, this sensor is easy to operate and is expected to have applications for rapid and sensitive on-site analysis. A good linear correlation over the concentration range of 10 to 750 nM of crystal violet with a correlation coefficient of 0.992 was obtained. The recovery was between 98.6% and 102.9% for crystal violet in river water with relative standard deviations between 2.43% and 4.26%.  相似文献   

9.
Microextraction by packed sorbents (MEPS) combined with Surface-enhanced Raman spectroscopy (SERS) was investigated, and applied to the determination of musk ketone (MK) in river water samples. The full MEPS–SERS method includes analyte enrichment by MEPS preconcentration with C18 sorbent followed by SERS detection supported by silver nanoparticles. An eluent drop containing the analyte is deposited directly from the MEPS syringe on a CaF2 glass plate. When the drop has dried, a specific volume of silver nanoparticles solution is added on it before each SERS measurement. Several experimental variables were studied in depth; under the optimum experimental conditions MK can be extracted from a 500 μL sample with recoveries in the range 47–63 %. The limit of detection was 0.02 mg L?1 and the relative standard deviation 15.2 % (n?=?4). Although not investigated in this work, the proposed method might be suitable for in-situ monitoring, because of the portability of the Raman spectrometer used.
Figure
Experimental scheme of the MEPS-SERS method proposed for the determination of musk ketone in river water  相似文献   

10.
We have synthesized silver nanoparticles (AgNPs) decorated with α-cyclodextrin (CD) by using the traditional silver mirror reaction in the presence of CD. The CD-AgNPs were used as substrate in surface-enhanced Raman spectroscopy (SERS) for determining melamine. The intensity of the Raman band of melamine at 704 cm?1 was used to determine melamine in milk and milk powder. The use of CD-AgNPs as the SERS substrate rather than classical silver nanoparticles makes the method more sensitive in giving an enhancement by a factor of up to?~?106 in scattering efficiency. The effects of the volume of solutions (of CD-AgNPs, NaCl, NaOH, melamine) and of mixing time were optimized. The standard addition method was employed for quantitative analysis. The correlation coefficient of the calibration plot is 0.9995, and the limit of detection is 3.0 μg L?1. The method was successfully applied to the determination of melamine in milk and milk powder, with relative standard deviations of <10 % and recoveries between 89 and 104 %.
Figure
Novel silver nanoparticles decorated with α-cyclodextrin (CD-AgNPs) were prepared. The melamine in milk and milk powder was determined using SERS and CD-AgNPs. The limit of detection is 3.0 μg L?1, and recoveries between 89 and 104 %  相似文献   

11.
We report on the detection of trace quantities of melamine (MA) by a colorimetric method that exploits the conformational change of hemin G-quadruplex-DNAzyme. The addition of MA to hemin G-quadruplex-DNAzyme structure containing thymine bases causes the thymine in the DNAzyme to interact with MA via a stable triple H-bond and leads to a conformational change. This, in turn, affects the peroxidase-like activity of hemin which is determined colorimetrically at 450 nm by adding 3,3’,5,5’-tetramethylbenzidine and hydrogen peroxide. The method was applied to the colorimetric determination of MA over a wide range of concentrations (0.2 to 24 μM) with a detection limit of 80 nM. The effect also can be detected with bare eyes. The method was successfully applied to the determination of MA in spiked milk powder.
Figure
A novel, simple and rapid, visual colorimetric method is applied for the detection of melamine with a wide range of 8?×?10?7 M to 1?×?10?3 M and low detection limit of 2.7?×?10?7 M.  相似文献   

12.
A novel facile method has been established for rapid on-site detection of antidiabetes chemicals used to adulterate botanical dietary supplements (BDS) for diabetes. Analytes and components of pharmaceutical matrices were separated by thin-layer chromatography (TLC) then surface-enhanced Raman spectroscopy (SERS) was used for qualitative identification of trace substances on the HPTLC plate. Optimization and standardization of the experimental conditions, for example the method used for preparation of silver colloids, the mobile phase, and the concentration of colloidal silver, resulted in a very robust and highly sensitive method which enabled successful detection when the amount of adulteration was as low as 0.001 % (w/w). The method was also highly selective, enabling successful identification of some chemicals in extremely complex herbal matrices. The established TLC–SERS method was used for analysis of real BDS used to treat diabetes, and the results obtained were verified by liquid chromatography–triple quadrupole mass spectrometry (LC–MS–MS). The study showed that TLC–SERS could be used for effective separation and detection of four chemicals used to adulterate BDS, and would have good prospects for on-site qualitative screening of BDS for adulterants.
Figure
Experimental procedure of TLC-SERS method  相似文献   

13.
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0–38 μM (R 2?=?0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-d-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12.5 μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays.
Figure
Multi-channel microfluidic biosensor with integrated IDUAs for a sandwich nucleic acid hybridization assay  相似文献   

14.
A miniaturized multiplex biosensor exploiting a microfluidic oligonucleotide array and chemiluminescence (CL) lensless imaging detection has been developed for parvovirus B19 genotyping. The portable device consists of a reaction chip, comprising a glass slide arrayed with three B19 genotype-specific probes and coupled with a polydimethylsiloxane microfluidic layer, and a charge-coupled device camera modified for lensless CL imaging. Immobilized probes were used in DNA hybridization reactions with biotin-labeled targets, and then hybrids were measured by means of an avidin-horseradish peroxidase (HRP) conjugate and CL detection. All hybridization assay procedures have been optimized to be performed at room temperature through the microfluidic elements of the reaction chip, with sample and reagents delivery via capillary force exploiting adsorbent pads to drive fluids along the microchannels. The biosensor enabled multiplex detection of all B19 genotypes, with detectability down to 80 pmol?L?1 for all B19 genotype oligonucleotides and 650 pmol?L?1 for the amplified product of B19 genotype 1, which is comparable with that obtained in traditional PCR-ELISA formats and with notably shorter assay time (30 min vs. 2 h). The specificity of the assay has been evaluated by performing DNA–DNA hybridization reactions among sequences with different degrees of homology, and no cross hybridizations among B19 genotypes have been observed. The clinical applicability has been demonstrated by assaying amplified products obtained from B19 reference serum samples, with results completely consistent with the reference PCR-ELISA method. The next crucial step will be integration in the biosensor of a miniaturized PCR system for DNA amplification and for heat treatment of amplified products.
Figure
A portable multiplex biosensor was developed for detection and genotyping of parvovirus B19 DNA, exploiting lensless CL imaging. The reaction chip is composed of a polydimethylsiloxane microfluidic layer coupled with a glass slide on which oligonucleotide probes specific for three different B19 genotypes are covalently immobilized in a 3?×?3 array. The reaction chip was used in hybridization reactions with biotin-labeled targets and then hybrids were then detected by means of an avidin-HRP conjugate, upon addition of a CL substrate for HRP  相似文献   

15.
Quantitating explosive materials at trace concentrations in real-time on-site within the marine environment may prove critical to protecting civilians, waterways, and military personnel during this era of increased threat of widespread terroristic activity. Presented herein are results from recent field trials that demonstrate detection and quantitation of small nitroaromatic molecules using novel high-throughput microfluidic immunosensors (HTMI) to perform displacement-based immunoassays onboard a HYDROID REMUS100 autonomous underwater vehicle. Missions were conducted 2–3 m above the sea floor, and no HTMI failures were observed due to clogging from biomass infiltration. Additionally, no device leaks were observed during the trials. HTMIs maintained immunoassay functionality during 2 h deployments, while continuously sampling seawater absent without any pretreatment at a flow rate of 2 mL/min. This 20-fold increase in the nominal flow rate of the assay resulted in an order of magnitude reduction in both lag and assay times. Contaminated seawater that contained 20–175 ppb trinitrotoluene was analyzed.
Figure
Displacement-based immunoassay targeting trinitrotoluene is shown  相似文献   

16.
Oligonucleotide-modified nanoparticle conjugates show highly promising potential for SERS-based DNA detection. However, it remains challenging to carry out the SERS-based DNA detection in aqueous solutions directly using oligonucleotide-modified nanoparticles, because the Raman reporters would exhibit lower signals when they are dispersed in aqueous solutions than laid on “dry” metal nanoparticles. Here, we synthesized stable oligonucleotide-modified Ag nanoprism conjugates, and performed SERS-based DNA detection in aqueous solution directly by using such conjugates in combination with Raman reporter-labeled, oligonucleotide-modified gold nanoparticles. The experimental results indicate that this SERS-based DNA detection approach exhibited a good linear correlation between SERS signal intensity and the logarithm of target DNA concentration ranging from 10?11~10?8 M. This sensitivity is comparable to those SERS-based DNA detection approaches with the “dry” process. Additionally, a similar correlation could also be observed in duplex target DNA detection by SERS hybrid probes. Our results suggest that the oligonucleotide-modified Ag nanoprisms may be developed as a powerful SERS-based DNA detection tool.
Scheme of SERS-based DNA detection in aqueous solutions. Capture DNA-modified Ag nanoprisms and Raman reporter-labeled, report DNA-modified gold nanoparticles are utilized in the detection  相似文献   

17.
We describe a method for the modification of gold nanoparticles (Au-NPs) with benzo-15-crown-5 that led to the development of a colorimetric assay for Ag(I) ion. The brown color of a solution of the modified Au-NPs turns to purple on addition of Ag(I) ion. The ratio of the UV–vis absorption at 600 nm and 525 nm is proportional to the concentration of Ag(I) ions in the range from 20 to 950 nM, and the detection limit is 12.5 nM. Other metal ions do not interfere if present in up to millimolar concentrations. The method enables a rapid determination of Ag(I) in lake and drinking water and is amenable to bare-eye readout.
Figure
The selective colorimetric detection of Ag+ ion using gold nanoparticles modified with benzo crown ether is reported with a color detection limit ~50 nM by naked-eye. The feasibility and simplicity of this cost-effective sensing system demonstrates great potential for the detection of sliver ion in real samples.  相似文献   

18.
We have fabricated an interdigitated double-coil microelectrode chip for the determination of traces of phosphate by making use of a MEMS technique and enzyme immobilization technology. The chip is composed of two 3-dimensional strip microelectrodes which form a double coil microelectrode configuration with steep sidewalls and high aspect ratio. This novel configuration results in a high current response during amplification by redox cycling. The enzyme pyruvate oxidase was immobilized on the chip using gold nanoparticles as a support. Phosphate can be determined by using this chip with good sensitivity and linearity and in concentrations ranging from 0.5 μM to 7 μM.
Figure
A 3-dimensional interdigitated double coils microelectrode chip, which is with micron level strip width and high aspect ratio of height to interval, was fabricated by MEMS technique and enzyme immobilization technology. As an important index of environment monitoring, trace phosphate was determinate by this microelectrode chip with good sensitivity and linearity.  相似文献   

19.
We demonstrate that base mismatches of caspase-3 DNA sequences can be detected by surface plasmon resonance (SPR) following signal amplification by polymerase from Thermus aquaticus (Taq). The concentration of magnesium ions and the respective dNTPs for polymerase binding to the oligonucleotides on the sensing surface were optimized. Taq polymerase binds to double-stranded DNA that is self-assembled on the gold surface of the biosensor to induce an SPR signal. Experiments are presented on the effect of Mg(II) and dNTP concentrations on the activity of the polymerase on the sensing surface. The detection limits are 50 pM, 0.1 nM, 0.7 nM, 7 nM, and 20 nM for correctly matched, single-base mismatched, two-base mismatched, three-base mismatched and four-base mismatched DNA of caspase-3, respectively. This is attributed to the optimized experimental conditions, with samples containing 2 μM of Mg(II) and 0.3 mM of dNTP.
Figure
The process of detecting mismatched caspase-3 DNA oligonucleotides with SPR biosensor  相似文献   

20.
The detection of volatile organic compounds is of great importance for assessing the quality of water. In this contribution, we describe a miniaturized stripping device that allows fast online detection of organic solvents in water. The core component is a glass microfluidic chip that facilitates the creation of an annular-flowing stream of water and nitrogen gas. Volatile compounds are transferred efficiently from the water into the gas phase along the microfluidic pathway at room temperature within less than 5 s. Before exiting the microchip, the liquid phase is separated from the enriched gas phase by incorporating side capillaries through which the hydrophilic water phase is withdrawn. The gas phase is conveniently collected at the outlet reservoir by tubing. Finally, a semiconductor gas sensor analyzes the concentration of (volatile) organic compounds in the nitrogen gas. The operation and use of the stripping device is demonstrated for the organic solvents THF, 1-propanol, toluene, ethylbenzene, benzaldehyde, and methanol. The mobile, inexpensive, and continuously operating system with liquid flow rates in the low range of microliters per minute can be connected to other detectors or implemented in chemical production line for process control.
Figure
We present a microfluidic device for highly efficient analytical stripping of organic solvents from water/solvent mixtures at room temperature  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号