首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method has been developed for determining benzo[a]pyrene in shale oil by combining dry-column chromatography, thin-layer chromatography and fluorescence spectrometry. A two-step separation method was employed to isolate benzo[a]pyrene from shale oil. Benzo[a]pyrene was identified and determined by detecting its fluorescence directly from chromatoplates; as little as 0.06 ng can be detected. The limit of detection of benzo[a]pyrene in shale oil is ca. 1.2 ppm and the reproducibility of the method is ±2.6 ppm.  相似文献   

2.
This paper presents the characterization of polycyclic aromatic hydrocarbons (PAHs) in solid-surface fluorescence as the first step for obtaining new optical sensors for PAHs screening. The fluorescence properties of the EPA-PAHs (naphthalene, acenaphthene, acenaphthylene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[k]fluoranthene, benzo[b]fluoranthene, benzo[a]pyrene, indeno [1,2,3-cd]pyrene, benzo[g,h,i]perylene and dibenzo[a,h]anthracene) on five types of solid-surfaces were evaluated. The experimental variables (pH and percentage of organic solvent in samples) were studied, obtaining different possibilities for making individual sensors for some of these PAHs and the best conditions for developing sensors for PAH screening were also studied.  相似文献   

3.
The most suitable wavelength intervals were selected for the determination of 4 polycyclic aromatic hydrocarbons (PAHs; benzo[g,h,i]perylene, dibenzo[a,h]anthracene, pyrene, and triphenylene) in very complex mixtures of 11 PAHs: anthracene, benz[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[g,h,i]perylene, benzo[k]fluoranthene, chrysene, dibenz[a,h]anthracene, phenanthrene, pyrene, and triphenylene. The multiple linear regression algorithm was applied to measurements made in several wavelength intervals previously selected on the basis of sensitivity and minimum number of interfering compounds. Of the different models obtained, those displaying minimum error propagation in the analytical result were selected. By applying the models proposed in this study, we precisely and accurately determined benzo[g,h,i]perylene, dibenz[a,h]anthracene, pyrene, and triphenylene in complex mixtures--a feat that could not be achieved by the use of constant-wavelength spectrofluorimetry in combination with second-derivative techniques.  相似文献   

4.
Abstract— Significant spectroscopic difference was found between the 3(π, π*) state of coumarins and the 3La state of benzpyrene. No analogy of the partially localized triplet state associated with the coumarin chromophore was revealed in the case of the potent carcinogen, benzo[a]pyrene. Instead, the 3La state of benzo[a]pyrene is characterized by more derealization than that of the non–carcinogenic benzo[e]pyrene. Therefore, the predominant photoreaction between benzo[a]pyrene and DNA bases does not seem to involve cycloaddition in contrast to the coumarin-pyrimidine system. Reactivity indices have been calculated, and results are consistent with recent experimental findings. In addition, spectroscopic properties of benzo[a]pyrene and benzo[e]pyrene have been comparatively described in terms of relatively high-resolution spectra, polarization measurements, and molecular orbital calculations.  相似文献   

5.
A method capable of determining 13 PAHs (acenaphthene, anthracene, benzo[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, chrysene, dibenzo[ah]anthracene, fluoranthene, fluorene, indene[1,2,3-cd]pyrene, phenanthrene and pyrene) in a mixture of 16 EPA PAHs by second derivative synchronous spectrofluorometry in the constant wavelength mode was developed. It has not been possible to determine the following PAHs in the mixture: acenaphthylene, benzo[ghi]perylene and naphthalene. The approach studied allows the sensitive, rapid and inexpensive identification and quantitation of 13 PAHs in a solution of hexane. The detection limits are <1 microg L(-1) (except for chrysene and phenanthrene).  相似文献   

6.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90-115%) and RSD % (< or =7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

7.
建立了固相萃取-高效液相色谱-荧光法检测方便面和烤肠中苯并[a]芘的方法。采用正己烷作为提取溶剂,经苯并[a]芘专用固相萃取柱HiCapt Benzo富集净化,高效液相色谱-荧光法对样品中苯并[a]芘进行分离分析。苯并[a]芘的质量浓度在0.5~20.0μg/kg范围内与色谱峰面积呈良好的线性关系,相关系数R2为0.9997。方便面和烤肠中苯并[a]芘的加标回收率分别为92.2%~98.3%和95.9%~97.9%,日内和日间相对标准偏差分别为3.34%~5.01%和2.11%~4.07%。与传统方法相比,该方法快速简单、有机溶剂消耗少,在油炸烟熏食品的苯并[a]芘分析中具有较大应用前景。  相似文献   

8.
We have evaluated both electron ionization (EI) and negative-ion chemical ionization (NICI) methods for the analysis of trimethylsilyl derivatives of a series of polycyclic aromatic hydrocarbon (PAH) alcohols including styrene diol, benzo[e]pyrene diol and tetrols, cyclopenta[c,d]pyrene diols, benzo[a]pyrene-4,5-diols, chrysene tetrols, benz[a]anthracene tetrols I and II, and syn- and anti-benzo[a]pyrene tetrols. NICI is the more sensitive method for all compounds except styrene diol. Detection limits are compound-dependent and range from 1 fmol for cyclopenta[c,d]pyrene diol to 1 pmol for benzo[e]pyrene diol. The EI detection limit for styrene diol is 60 fmol. PAH alcohols related to the compounds listed above were observed following hydrolysis of hemoglobin which had been reacted with PAH epoxides in vitro. Benzo[a]pyrene tetrols and a chrysene tetrol were observed following hydrolysis of hemoglobin isolated from human smokers' blood. Hydrolysis of styrene oxide treated hemoglobin in 18O-labeled water revealed at least two mechanisms of ester hydrolysis, including the BAL 1 pathway.  相似文献   

9.
[structure: see text] The synthesis of phenanthrene and benzo[e]pyrene bisimides, 1 and 2, was accomplished via the Diels-Alder trapping of sterically congested o-xylylenols photochemically generated from 3,6-dibenzoyl-o-xylene and 1,4-dibenzoyl-9,10-dihydroanthracene, respectively. Absorption and emission from 2 are red-shifted from 1 and unsubstituted benzo[e]pyrene. The fluorescence quantum yield for 2 is an order of magnitude lower than that of 1 and comparable to that of the parent benzo[e]pyrene.  相似文献   

10.
The formation of polycyclic aromatic hydrocarbons (PAHs) during pyrolysis process of phenylalanine had been studied. Ten PAHs, including fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[k]fluoranthene, benzo[e]pyrene, and benzo[a]pyrene were analyzed by gas chromatography-mass spectrometry using selective ion monitoring mode. This technique offers the capability to analyze trace amounts of PAHs in phenylalanine pyrolyzates. The pyrolysis was carried out in a micro-furnace with quartz furnace liner. The injection was conducted with glass pelletizer syringe to avoid metal contamination. Qualitative results were obtained at 900 degrees C and quantitative analysis of 10 PAHs was done for 700 and 900 degrees C.  相似文献   

11.
A simple and rapid method for the highly sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in water was developed. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene in water were concentrated into sodium dodecyl sulfate (SDS)-alumina admicelles. The collection was performed by adding SDS and alumina particles into the sample solution at pH 2. After gentle mixing, the resulting suspension was passed through a membrane filter to collect the SDS admicelles containing highly concentrated PAHs. The filter was placed on a slide glass and then covered admicellar layer with a fused silica glass plate before setting in a fluorescence spectrometer. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene were selectively determined by the synchronous fluorescence scan (SFS) analysis with keeping wavelength intervals between excitation and emission to 98, 35, 29, and 45 nm, respectively. Because of the minimum spectral overlapping, 1-40 ng l−1 of benzo[a]pyrene, benzo[k]fluoranthene, and perylene as well as 10-150 ng l−1 of pyrene were selectively determined with eliminating the interferences of other 12 PAHs. The detection limits were 0.3 ng l−1 for benzo[a]pyrene, benzo[k]fluoranthene, and perylene, and 1 ng l−1 for pyrene. They were 2-3 orders of magnitude lower than the detection limits in normal aqueous micellar solutions. The application to water analysis was studied.  相似文献   

12.
The use of derivative constant-wavelength synchronous scan fluorimetry is reported for the determination of three polycyclic aromatic hydrocarbon pollutants in drinking water (linearity range 0.4-4 mug 1(-1)). The limits of detection (LD) and quantification (LQ) (mug 1(-1)) are 0.01 and 0.07 for benzo[b]fluoranthene, 0.03 and 0.12 for benzo[a]pyrene and 0.19 and 0.57 for indeno[1,2,3-cd]pyrene in the presence of three other pollutants, benzo[k]fluoranthene, benzo[ghi]perylene and fluoranthene. The precision (RSD /= 85%) were satisfactory.  相似文献   

13.
Dubois  L.  Zdrojewski  A.  Monkman  J. L. 《Mikrochimica acta》1967,55(5):834-842
Microchimica Acta - The technique for determining benzo[a]pyrene, benzo[k]fhuoranthene, and benzo[g,h,i]perylene respectively inμg amounts by UV absorption measurements is described. The...  相似文献   

14.
Abstract— Recent studies have shown that ultraviolet (UV) irradiation induces a systemic effect which enhances subsequent tumor induction by benzo[a]pyrene in a manner which is dependent on the dose of benzo[a]pyrene. The present study was designed to test whether UV-B irradiation renders mice susceptible to subcutaneous or intravenous injection of a regressor tumor induced by benzo[a]pyrene. The sources of UV-B irradiation were banks of 6 Westinghouse FS-40 sunlamps, situated 20 cm above the mouse cages. Female BALB/cAnNHsd received five 30-min dorsal UV-B radiation treatments per week for 12 weeks, resulting in a total dose of approx. 6.4 × 105 J m-2. Two to seven days after termination of UV treatments, syngeneic regressor tumor cells (BP2) induced by benzo[a]pyrene were injected subcutaneously or intravenously into irradiated mice and unirradiated controls. By 38 days post subcutaneous implantation, 24/30 and 3/30 BP2 implants were detectable in the irradiated and unirradiated mice, respectively. Ultraviolet irradiated mice were also unable to reject lung colonies resulting from intravenous administration of BP2 cells, although they were rejected by unirradiated mice. The mean number of lung colonies per mouse was 16- to 35-fold greater in UV irradiated mice than in unirradiated controls, at 14 to 17 days post injection. Thus, UV irradiation rendered mice, with no known exposure to benzo[a]pyrene, susceptible to a subcutaneous or intravenous injection of a regressor tumor induced by benzo[a]pyrene.  相似文献   

15.
Biogeochemical interfaces in soil are dynamic in the spatial and temporal domain and require advanced visualisation and quantification tools to link in vitro experiments with natural systems. This study presents the development, characterization and application of functional nanoparticles coated with monoclonal antibodies to visualise the distribution of benzo[a]pyrene in porous media using magnetic resonance imaging. The labelled particles are 450 nm in diameter and interact with benzo[a]pyrene covalently bound to silanized silica gel. They did not bind to benzo[a]pyrene adsorbed to plain silica gel. Although unspecific filtration was low, washing steps are required for visualisation. The ability to visualise benzo[a]pyrene is inversely correlated to the heterogeneity of the soil materials. There are access restrictions to narrow pore spaces which allow the visualisation of only those pathways which are also accessible to bacteria and hydrocolloids. The production of the particles is applicable to other antibodies which extends the range of potential target contaminants.  相似文献   

16.
In this paper an application of new procedures for atmospheric particulate analysis is illustrated. PM10, PAHs (benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1, 2, 3-cd]pyrene (Ip), dibenzo[a, h]anthracene (DbA)) and heavy metals (Cu, Ni, Zn, Co, Mn, Cd, Fe and Pb) were investigated. PM10 determination was performed by gravimetric method, PAHs were measured by GC-MS, and heavy metals by HPIC. An air quality monitoring campaign on the territory of Bari municipality has been organised, and its results are shown.  相似文献   

17.
Bian Z  Tang G  Chen Z  Pang Y  Jiang X  Hu Q 《色谱》2011,29(10):1031-1035
以全自动固相萃取技术净化主流烟气萃取液,建立了卷烟主流烟气中苯并[a]芘、苯并[a]蒽和屈艹 3种多环芳烃的气相色谱-串联质谱(GC-MS/MS)测定方法。以吸烟机抽吸卷烟,并以剑桥滤片捕集卷烟主流烟气,然后以含氘代苯并[a]芘内标的环己烷溶液萃取滤片,萃取液经全自动固相萃取仪净化后以GC-MS/MS分离检测。结果表明,苯并[a]芘、苯并[a]蒽和屈艹 的检出限分别为0.05、0.16和0.23 ng/cig,回收率为91.5%~102.1%,相对标准偏差(RSD)均小于5%。该方法的自动化程度高、操作简便、检出限低、重复性好,适用于卷烟主流烟气中苯并[a]芘、苯并[a]蒽 3种多环芳烃释放量的检测。  相似文献   

18.
A simple and rapid microwave-assisted extraction (MAE) procedure was developed and optimized for benzo[a]anthracene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in wood samples. The spiked wood used was prepared 3 months before analysis to simulate weathering processes and to allow the formation of analyte-matrix interaction. The samples, immersed in acetonitrile were irradiated with microwaves in a closed-vessel system. Optimization of the method was achieved by using a factorial design approach on parameters such as extraction time, temperature and sample amount. The analysis of extracts has been carried out by reversed-phase high-performance liquid chromatography with fluorescence detection for quantification and UV-diode-array detection for confirmation. The MAE procedure yielded extracts that could be analyzed directly without any preliminary clean-up or solvent exchange steps.  相似文献   

19.
In the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg?1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg?1.  相似文献   

20.
The zero-field transitions in the photoexcited triplet state of benzo[α]pyrene bound to DNA have been observed by optical detection of magnetic resonance of 2 K. The transition frequencies individual spin sublevel intersystem crossing rates were measured by monitoring the microwave-induced intensity changes of the triplettriplet absorption at 465.8 nm. The triplet state zero-field splitting and dynamics for the benzo[α]pyrene DNA complex are compared with these properties measured for benzo(α)pyrene in other solvent systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号