Solid-phase sulfonation of tryptic peptides adsorbed to C18 muZipTips has been carried out to facilitate de novo sequencing with mass spectrometry. Peptides are reacted with the sulfonation reagent while they are still adsorbed to the solid phase. Excess reagent passes through the ZipTip to waste. Washing the products before subsequent elution from the mini-column also affords sample cleanup prior to analysis. Near quantitative N-terminal sulfonation can be achieved reliably at room temperature in only a few seconds. The method has been applied successfully to model peptides and to solution or in-gel digests of proteins. Current sequencing limits are about 100 fmol of protein. Multiplexed sample sulfonation reactions have been carried out with a manual 8-position micropipettor or using centrifugal force to reliably pass reagents and wash solutions over sample-loaded ZipTips. With multiplexing, overall preparation times have been reduced to about 1 min per sample. The solid-phase format facilitates efficient use of precious digest samples by enabling them to be recovered from the matrix-assisted laser desorption/ionization (MALDI) sample stage after mass fingerprinting, derivatized and re-analyzed by MALDI postsource decay mass spectrometry.  相似文献   

2.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

3.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

4.
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.  相似文献   

5.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

6.
In recent years, various mass spectrometry procedures have been developed for bacterial identification. The accuracy and speed with which data can be obtained by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) could make this a powerful tool for environmental monitoring. However, minor variations in the sample preparation can influence the mass spectra significantly. Therefore, the first objectives of this study were the adjustment and the optimization of experimental parameters allowing a rapid identification of whole bacterial cells without laborious sample preparation. The tested experimental parameters were matrix, extraction solvent, salt content, deposition method, culture medium and incubation time. This standardized protocol was applied to identify reference and environmental bacterial strains of Escherichia coli, Salmonella and Acinetobacter. The environmental bacterial strains were isolated from sewage sludge using an original microextraction procedure based on repeated sonications and enzymatic treatments. The bacterial identification was realized by the observation of the respective genus-, species- and strain-specific biomarkers. This bacterial taxonomy could be completed within one hour, with minimal sample preparation, provided that sufficient bacteria had been collected prior to MALDI-TOF analysis.  相似文献   

7.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

8.
The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3-methylthiazolidine-4-carboxylic acid).  相似文献   

9.
A method to aid in the analysis of bacterial samples of unknown concentration by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is demonstrated. It is shown that in MALDI analysis of bacteria, the intensities of resulting peaks in spectra are sensitive to the microbial concentration. At the high and low ends of the concentration range, no signal can be obtained, leaving very concentrated or very dilute samples indistinguishable. The addition of cytochrome c as an internal control allows the differentiation of these concentrated and dilute samples. The presence of the internal control causes only a 20% to 30% decrease in signal intensity when the bacterial concentration is optimum. However, the signal quality is improved when the internal control is added to some low concentrations of bacteria.  相似文献   

10.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is a powerful tool for the measurement of low molecular mass compounds of biological interest. The limitations for this method are the volatility of many analytes, possible interference with matrix signals or bad ionization or desorption behavior of the compounds. We investigated the application of well-known and straightforward one-pot derivatization procedures to circumvent these problems. The derivatizations tested allow the measurement and the labeling of alcohols, aldehydes and ketones, carboxylic acids, alpha-ketocarboxylic acids and amines.  相似文献   

11.
A protocol for the preparation of polymeric samples for time-of-flight matrix-assisted laser desorption ionization mass spectrometry (TOF-MALDI-MS) analysis was developed. Dithranol was identified as a good matrix for polystyrene (PS), and the addition of silver for cationization of molecules was determined to be necessary. Based on this preparative method, low molecular weight samples of other polymers [polyisoprene, polybutadiene, poly(ethylene oxide), poly(methyl methacrylate), and polydimethylsiloxane] were analyzed with molecular weights up to 49 ku. The effects of laser intensity were determined to influence the molecular weight distribution of intact oligomers, most significantly for low molecular weight polymers. Linear and reflectron modes of analysis were evaluated; better signal intensity and resolution were obtained in the reflectron mode. The TOF-MALDI-MS measurements are compared with time-of-flight secondary ion mass spectrometry (TOF-SIMS) and gel permeation chromatography (GPC) for the same polymers. The M n values calculated by TOF-MALDI-MS consistently are higher than values calculated by TOF-SIMS for all classes of polymers with molecular weights up to 8 ku. The molecular weights of the PS calculated from TOF-MALDI-MS are in good agreement with GPC (±10%). The composition of the terminal group on a polymer chain may affect the ion yields. The ion yields of intact oligomers were evaluated as a function of end group composition for both TOF-MALDI-MS and TOF-SIMS. The slight disparity of results between TOF-SIMS and TOF-MALDI-MS for the perfluoroalkyl-terminated PS suggests that the oligomers are desorbed preferentially from the surface in the TOF-SIMS analysis, rather than having an increased ionization probability.  相似文献   

12.
The analysis of oligonucleotides using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has led to the investigation of the use of matrix additives (i.e., co-matrices) to help improve the poor spectral quality commonly observed during the analysis of this class of compounds. The use of certain matrix additives in MALDI-MS has been investigated previously, and these additives have been shown to enhance the desorption/ionization efficiency of oligonucleotides during the MALDI experiment. Specifically, amine bases, such as piperidine, imidazole, and triethylamine, have been shown to improve mass spectral quality as assessed by improved molecular ion resolution and increased molecular ion abundance. These improvements occur due to competition between the oligonucleotide and the co-matrix for protons generated during the MALDI event. Co-matrices with proton affinities near or above the proton affinities of the nucleotide residues serve as proton sinks during the desorption/ionization process. In this work, we have investigated the use of polyamines as co-matrices for MALDI mass spectrometric analysis of oligonucleotides. Spermine tetrahydrochloride, spermine, spermidine trihydrochloride, and spermidine were evaluated for their effectiveness at enhancing the mass spectral quality of oligonucleotides analyzed using MALDI-MS. The solution-phase pK( b) values and the gas-phase proton affinities of these polyamines were determined, and it was found that the polyamines appear to be more basic than the monofunctional amines investigated previously. The mass spectral data shows that spermidine and spermine are extremely effective co-matrices, yielding improved molecular ion resolution and molecular ion abundances. The spermine co-matrices are more effective than the spermidine co-matrices, but adduction problems with the spermine co-matrices limits their overall utility. In general, polyamine co-matrices are found to be more effective than monofunctional amine co-matrices at improving the mass spectral data obtained during MALDI-MS of oligonucleotides.  相似文献   

13.
The S-nitrosylation of proteins is involved in the trafficking of nitric oxide (NO) in intra- and extracellular milieus. To establish a mass spectrometric method for identifying this post-translational modification of proteins, a synthetic peptide and transthyretin were S-nitrosylated in vitro and analyzed by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The intact molecular ion species of nitrosylated compounds was identified in the ESI mass spectrum without elimination of the NO group. However, the labile nature of the S-NO bond was evident when the in-source fragmentation efficiently generated [M + H - 30](+) ions. The decomposition was prominent for multiply charged transthyretin ions with high charge states under ordinary ESI conditions, indicating that the application of minimum nozzle potentials was essential for delineating the stoichiometry of nitrosylation in proteins. With MALDI, the S-NO bond cleavage occurred during the ionization process, and the subsequent reduction generated [M + H - 29](+) ions.  相似文献   

14.
Various types of ionization of organotellurium compounds in mass-spectrometric study are considered, with diphenyl telluroxide as example. The mass spectra of diphenyl telluroxide are presented. The possibility of applying surface-activated and matrix-assisted laser desorption/ionization mass spectrometry to organotellurium compounds is examined.  相似文献   

15.
A variety of surfactants have been tested as matrix-ion suppressors for the analysis of small molecules by matrix-assisted laser desorption/ionization time-of flight mass spectrometry. Their addition to the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) greatly reduces the presence of matrix-related ions when added at the appropriate mole ratio of CHCA/surfactant, while still allowing the analyte signal to be observed. A range of cationic quaternary ammonium surfactants, as well as a neutral and anionic surfactant, was tested for the analysis of phenolics, phenolic acids, peptides and caffeine. It was found that the cationic surfactants, particularly cetyltrimethylammonium bromide (CTAB), were suitable for the analysis of acidic analytes. The anionic surfactant, sodium dodecyl sulfate, showed promise for peptide analysis. For trialanine, the detection limit was observed to be in the 100 femtomole range. The final matrix/surfactant mole ratio was a critical parameter for matrix ion suppression and resulting intensity of analyte signal. It was also found that the mass resolution of analytes was improved by 25-75%. Depth profiling of sample spots, by varying the number of laser shots, revealed that the surfactants tend to migrate toward the top of the droplet during crystallization, and that it is likely that the analyte is also enriched in this surface region. Here, higher analyte/surfactant concentration would reduce matrix-matrix interactions (known to be a source of matrix-derived ions).  相似文献   

16.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced.  相似文献   

17.
In this report, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to study the binding interactions between calmodulin and two target peptides (melittin and substance P). Various matrix conditions were tested and the less acidic matrix DHAP and THAP were found to favor the survival of the intact calcium-calmodulin as well as the calmodulin-peptide complexes. However, the application of direct MALDI-MS to detect the intact complexes turned out to be very difficult due to the dissociation of the complexes and the formation of nonspecific aggregates. In contrast, the specific binding of the target peptides to calmodulin could be easily deduced using intensity-fading (IF) MALDI-MS. Compared with the nonbinding control, clear reduction in the ion abundances of the target peptides was observed with the addition of calmodulin. Relative binding affinities of different peptides towards the protein could also be estimated using IF-MALDI-MS. This study may extend the application of IF-MALDI-MS in the analysis of noncovalent complexes and offer a perspective into the utility of MALDI-MS as an alternative approach to study the peptides binding to calmodulin.  相似文献   

18.
The identification of isoforms is one of the great challenges in proteomics due to the large number of identical amino acids preventing their separations by two-dimensional electrophoresis. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has become a rapid and sensitive tool in proteomics, notably with the new instrumental improvements. In this study, we used several acquisition modes of MALDI-TOFMS to identify isoforms of porcine glutathiones S-transferase. The use of multiple proteases coupled to the different acquisition modes of MALDI-TOFMS (linear, reflectron, post-source decay (PSD) and in-source decay, positive and negative modes) allowed the identification of two sequences. Moreover, a third sequence is pointed out from a PSD study of a tryptic ion revealing the modification of the amino acid tyrosine 146 to phenylalanine.  相似文献   

19.
The desorption/ionization behaviour of polycyclic aromatic hydrocarbons (PAHs) in matrix-assisted laser desorption/ionization (MALDI) and laser desorption (LD) mass spectrometry was studied by the solvent-free sample preparation method. As the understanding of the desorption/ionization mechanism in MALDI is normally hampered by the different ionization and desorption efficiencies of the analytes, this work was focused on the analyses of a homologous series of four hexabenzocoronenes (HBCs) possessing virtually the same ionization efficiency: HBC parent, hexamethyl-hexabenzocoronene (HBC-C1), hexapropyl-hexabenzocoronene (HBC-C3) and hexakis(dodecyl)-hexabenzocoronene (HBC-C12). The different signal intensities obtained in their mass spectra can be related to differences in their desorption efficiencies, which are attributed to the different strengths of the intermolecular interactions between unsubstituted and alkylated HBCs in the solid state. The influence of the aromatic structure of PAHs on their photoionization/desorption probability was investigated. As a model system, an equimolar mixture composed of HBC-C12 and hexakis(dodecyl)-hexaphenylbenzene (HPB-C12) was chosen. The aromatic structures of both molecules and thus their absorption coefficients at the laser wavelength differ substantially and have a huge influence on their photoionization efficiency. The combined effect of laser light absorption and intermolecular interactions on the desorption/ionization behaviour of giant PAHs was further studied by using an equimolar mixture composed of a larger PAH (C(222)H(42)) and its dendritic precursor (C(222)H(150)). This mixture shows the opposite behaviour to that of the former example, because the balance between desorption and ionization efficiency has changed significantly. The present investigation should be of interest for providing a better understanding of MALDI and LD spectra obtained from natural PAH-containing samples, such as heavy oils, asphaltenes or pitches, for which our artificial mixtures represent suitable model systems.  相似文献   

20.
Simple, rapid and inexpensive one-step reverse micellar microextraction (RMME) procedures were combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) for the determination of thiol-containing peptides and amino acids. In this investigation, a thiol-containing peptide (HW6) was chosen as model compound to understand the mechanism of RMME. The electrostatic interactions between the thiol-containing peptide and reverse micelles were proposed to be reason for the transfer of analytes from the aqueous phase to the organic phase. Reverse micelles were formed by the cationic surfactant, methyltrioctylammonium chloride (MTOAC). The best extraction efficiency of HW6 was obtained under the following conditions: pH 11.0, ionic strength 5.0 mM of KCl and micelle concentration 7.0 mM of MTOAC. The limits of detection (LODs) obtained for HW6 in water, urine and plasma samples were 0.15, 0.19 and 0.28 microM, respectively, with relative standard deviation (RSD) values in the range +/-8.8-10.5%. The sensitivity obtained in water by the present method was 45-fold higher than that of the conventional use of atmospheric-pressure (AP)-MALDI MS. Furthermore, the applicability of the proposed approach was extended for the determination of thiol-containing amino acids in sample solutions by using MALDI time-of-flight (TOF) MS.  相似文献   