共查询到20条相似文献,搜索用时 0 毫秒
1.
Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
Jahan Bakhsh Raoof Reza Ojani Mansureh Kolbadinezhad 《Journal of Solid State Electrochemistry》2009,13(9):1411-1416
The electrocatalytic oxidation of glutathione (GSH) has been studied at the surface of ferrocene-modified carbon paste electrode
(FMCPE). Cyclic voltammetry (CV), double potential step chronoamperometry, and differential pulse voltammetry (DPV) techniques
were used to investigate the suitability of incorporation of ferrocene into FMCPE as a mediator for the electrocatalytic oxidation
of GSH in buffered aqueous solution. Results showed that pH 7.00 is the most suitable for this purpose. In the optimum condition
(pH 7.00), the electrocatalytic ability of about 480 mV can be found and the heterogeneous rate constant of catalytic reaction
was calculated as . Also, the diffusion coefficient of glutathione, D, was found to be 3.61 × 10–5 cm2 s−1. The electrocatalytic oxidation peak current of glutathione at the surface of this modified electrode was linearly dependent
on the GSH concentration and the linear analytical curves were obtained in the ranges of 3.2 × 10–5 M–1.6 × 10–3 M and 2.2 × 10–6 M–3.5 × 10–3 M with cyclic voltammetry and differential pulse voltammetry methods, respectively. The detection limits (3σ) were determined as 1.8 × 10–5 M and 2.1 × 10–6 M using CV and DPV, respectively. Finally, the electrocatalytic oxidation of GSH at the surface of this modified electrode
can be employed as a new method for the voltammetric determination of glutathione in real samples such as human plasma. 相似文献
2.
A sensitive and stable electrochemical sensor was developed by modification of carbon paste electrode with ZrO2/graphene/chitosan nanocomposite. The modified sensor served as a potential electrocatalytic platform for dopamine. Electrochemical impedance spectroscopy studies indicated reduction of charge transfer resistance at the modified electrode surface thereby facilitating the electron transfer process which resulted in higher current response to dopamine. The electrochemical behavior of dopamine at the modified electrode was studied using cyclic and square wave voltammetry. The maximum current response for the electro-oxidation of dopamine was observed at pH 7.4 and the process was realized to be diffusion controlled. The modified sensor demonstrated linearity in the range 1000–5000 nM, with high sensitivity (22 nA/nM), detection limit of 11.3 nM and selectivity for dopamine in the presence of ascorbic and uric acid which are found to co-exist with dopamine in physiological media. The method was employed for quantification of dopamine in a pharmaceutical formulation. 相似文献
3.
《Colloids and surfaces. B, Biointerfaces》2010,79(2):217-221
In this work, we have prepared nano-material modified carbon paste electrode (CPE) for the sensing of an antidepressant, buzepide methiodide (BZP) by incorporating TiO2 nanoparticles in carbon paste matrix. Electrochemical studies indicated that the TiO2 nanoparticles efficiently increased the electron transfer kinetics between drug and the electrode. Compared with the nonmodified CPE, the TiO2-modified CPE greatly enhances the oxidation signal of BZP with negative shift in peak potential. Based on this, we have proposed a sensitive, rapid and convenient electrochemical method for the determination of BZP. Under the optimized conditions, the oxidation peak current of BZP is found to be proportional to its concentration in the range of 5 × 10−8 to 5 × 10−5 M with a detection limit of 8.2 × 10−9 M. Finally, this sensing method was successfully applied for the determination of BZP in human blood serum and urine samples with good recoveries. 相似文献
4.
In this work, we developed a novel graphene-assisted matrix solid-phase dispersion (GA-MSPD) method for extraction of polybrominated diphenyl ethers (PBDEs) and their methoxylated (MeO-) and hydroxylated (OH-) analogs from environmental samples. We found that grinding the solid sample with chemically converted graphene (CCG) powder yielded a tight contact and sufficient dispersion of the sample matrix due to the large surface area and flexible nanosheet morphology of CCG. The resultant blend was eluted using a two-step elution strategy: PBDEs and MeO-PBDEs were eluted firstly by hexane/dichloromethane and analyzed by GC-ECD, and then OH-PBDEs were eluted by acetone and determined by LC-ESI-MS/MS. The GA-MSPD conditions were optimized in detail. Better recoveries were obtained with GA-MSPD than with other sorbents (C18 silica, Florisil and carbon nanotubes) and other extraction techniques (Soxhlet and accelerated solvent extraction). Other advantages of GA-MSPD, including reduced consumption of sorbent and solvent, good selectivity and short extraction time, were also demonstrated. In analysis of soil samples, the method detection limits of five PBDEs, ten MeO-PBDEs and ten OH-PBDEs were in the range of 5.9-28.7, 14.3-46.6, and 5.3-212.6 pg g(-1) dry weight, respectively. The proposed method was successfully applied to the extraction of PBDEs, MeO-PBDEs and OH-PBDEs from different kinds of spiked environmental samples, including soil, tree bark and fish. 相似文献
5.
A sensitive and selective electrochemical sensor for the determination of nitrobenzene (NB) was developed based on a carbon paste electrode (CPE) modified with a nanocomposite prepared from the conducting polymer poly(3,4-ethylenedioxythiophene) and carbon nanotubes. The modified CPE exhibits good conductivity, a large surface area, and excellent catalytic activity towards the electrochemical reduction of NB. Under optimal conditions, the modified CPE is capable of detecting NB in the 0.25 to 43 μM concentration range and with a detection limit at 83 nM. Moreover, the sensor is highly stable and reusable, and free of interferences by other commonly present nitro compounds. It was used to determine NB in wastewater samples. Figure
A sensitive nitrobenzene sensor was developed based on the chemically synthesized nanocomposite composed of conducting polymer poly(3,4-ethylenedioxythiophene) and carbon nanotubes, which showed excellent catalytic activity towards the electrochemical reduction of nitrobenzene. 相似文献
6.
《中国化学快报》2019,30(12):2211-2215
An electrochemical sensor based on self-made nano-porous pseudo carbon paste electrode (nano-PPCPE) has been successfully developed, and used to detect Cd2+ and Pb2+. The experimental results showed that the electrochemical performance of nanoPPCPE is evidently better than both glassy carbon electrode (GCE) and pure carbon paste electrode (CPE). Then the prepared nano-PPCPE was applied to detect Cd2+ and Pb2+ in standard solution, the results showed that the electrodes can quantitatively detect trace Cd2+ and Pb2+, which has great significance in electrochemical analysis and detection. The linear ranges between the target ions concentration and the DPASV current were from 0.1–3.0 μmol/L, 0.05–4.0 μmol/L for Cd2+ and Pb2+, respectively. And the detection limits were 0.0780 μmol/L and 0.0292 μmol/L, respectively. Moreover, the preparation of the nano-PPCPE is cheap, simple and has important practical value. 相似文献
7.
An amperometric dipyrone sensor based on a polymeric nickel-salen (salen = N,N´-ethylenebis(salicydeneiminato)) film coated platinum electrode was developed. The sensor was constructed by electropolymerization of nickel-salen complex at a platinum electrode in acetonitrile/tetrabuthylamonium perchlorate by cyclic voltammetry. After cycling the modified electrode in a 0.50 mol L-1 KCl solution, the estimated surface concentration was found to be equal to 1.29 x 10-9 mol cm-2. This is a typical behavior of an electrode surface immobilized with a redox couple that can usually be considered as a reversible single-electron reduction/oxidation of the nickel(II)/nickel(III) couple. A plot of the anodic current versus the dipyrone concentration for chronoamperometry (potential fixed = +0.50 V) at the sensor was linear in the 4.7 x 10-6 to 1.1 x 10-4 mol L-1 concentration range and the concentration limit was 1.2 x 10-6 mol L-1. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations. 相似文献
8.
Dong Sun Xiaokun Li Huajie Zhang Xiafeng Xie 《International journal of environmental analytical chemistry》2013,93(3):324-333
A mesoporous silica was synthesised and used to modify the surface of carbon paste electrode (CPE). The electrochemical behaviours of p-aminophenol were investigated. Compared to the unmodified CPE, the mesoporous silica-modified CPE obviously lowers the oxidation potential of p-aminophenol, and remarkably increases its oxidation peak current. The effects of pH value, amount of mesoporous silica, accumulation potential and time were examined. As a result, a sensitive, rapid and convenient electroanalytical method was developed for p-aminophenol. The linear range is from 0.025?mg?L?1 to 3?mg?L?1, and the limit of detection is 0.01?mg?L?1 after 2-min accumulation. Finally, the method was successfully used to determine p-aminophenol in water samples. 相似文献
9.
采用水热法合成了纳米氧化锌-氧化石墨烯复合材料,并基于该复合材料构制了一种新型双酚A传感器,研究了该传感器的电化学行为。结果表明,在含8.0×10-5mol/L CTAB的p H 7.0磷酸盐缓冲液中,双酚A在0.573V处出现1个不可逆的氧化峰,具有良好的电化学响应;其氧化峰电流与浓度在1.0×10-8~4.0×10-5mol/L范围内呈良好的线性关系,检出限为5.0×10-9mol/L;对模拟环境水样中双酚A进行3次平行测定的回收率在96.3%~101.9%之间,相对误差在1.2%~3.8%范围内。该传感器具有灵敏度高、线性范围宽的特点。 相似文献
10.
Jahan Bakhsh Raoof Reza Ojani Maryam Ramine 《Journal of Solid State Electrochemistry》2009,13(9):1311-1319
A p-duroquinone (tetramethyl-p-benzoquinone) modified carbon paste electrode (DMCPE) was employed to study the electrocatalytic reduction of nitrite in
aqueous solutions using cyclic voltammetry (CV), double potential-step chronoamperometry, and differential pulse voltammetry
(DPV). It has found that under an optimum condition (pH 1.00), the reduction of nitrite at the surface of DMCPE occurs at
a potential of about 660 mV less negative than that of an unmodified carbon paste electrode (CPE). The catalytic rate constant,
k′h, based on Andrieux and Saveant theoretical model was calculated as for scan rate 10 mV s-1. Also, the apparent diffusion coefficient, D
app, was found as 2.5 × 10–10 and 3.61 × 10–5 cm2 s-1
for p-duroquinone in carbon paste matrix and nitrite in aqueous buffered solution, respectively. The values for αnα were estimated to be −0.65 and −0.19 for the reduction of nitrite at the surface of DMCPE and CPE, respectively. The electrocatalytic
reduction peak currents showed a linear dependence on the nitrite concentration, and a linear analytical curve was obtained
in the ranges of 5.0 × 10–5 M to 8.0 × 10–3 M and 6.0 × 10–6 M to 8.0 × 10–4 M of nitrite concentration with CV and DPV methods, respectively. The detection limits (2σ) were determined as 2.5 × 10–5 M and 4.3 × 10–6 M by CV and DPV methods. This method was also applied as a simple, selective and precise method for determination of nitrite
in real samples (the weak liquor from the wood and paper factory of Mazandaran province in Iran) by using a standard addition
method. 相似文献
11.
Silicon dioxide nanoparticles modified carbon paste electrode was fabricated and used for electrochemical investigation of tryptophan. Compared with the unmodified electrode, the peak current significantly increased. Experimental conditions for tryptophan determination were optimized. Linear relationship between the peak current and tryptophan concentration was obtained in the range of 1.0 × 10?7?5.0 × 10?6 mol L?1 and 5.0 × 10?6?5.0 × 10?5 mol L?1 with an estimated detection limit of 3.6 × 10?8 mol L?1 (S/N = 3). Tryptophan in pharmaceutical and human serum samples were successfully determined by the proposed method. 相似文献
12.
Banafsheh Norouzi Ali Malekan Majid Moradian 《Russian Journal of Electrochemistry》2016,52(4):330-339
In the present work, nickel-zeolite modified carbon paste electrode (Ni-ZMCPE) was prepared. The electrochemical behaviour of hydrogen peroxide at the surface of modified electrode was investigated by cyclic voltammetry and chronoamperometry in 0.1 M NaOH supporting electrolyte. The electrochemical characterization of Ni-ZMCPE exhibits redox behavior of Ni(III)/Ni(II) couple in alkaline medium. It has been shown that Ni-ZMCPE improves efficiency of the modified electrode toward hydrogen peroxide electrooxidation (It wasn’t remarkable different on ZMCPE and CPE in the presence and absence of hydrogen peroxide). Moreover, the effects of various parameters such as effect of different percents of Ni-Z to graphite, effect of pH and hydrogen peroxide concentration on the electrooxidation of hydrogen peroxide as well as stability of the Ni-ZMCPE have also been investigated. Under the selected conditions, the anodic peak current was linearly dependent on the concentration of hydrogen peroxide in the range 0.03–0.1 and 0.3–6 mM with amperometric method. The detection limit (S/N = 3) was also estimated to be 1 μM. 相似文献
13.
J. Tashkhourian S. F. Nami Ana S. Hashemnia M. R. Hormozi-Nezhad 《Journal of Solid State Electrochemistry》2013,17(1):157-165
A modified carbon paste electrode was prepared by incorporating the TiO2 nanoparticles in the carbon paste matrix. The electrochemical behavior of gallic acid (GA) is investigated on the surface of the electrode using cyclic voltammetry and differential pulse voltammetry. The surface morphology of the prepared electrode was characterized using the scanning electron microscopy. The results indicate that the electrochemical response of GA is improved significantly at the modified electrode compared with the unmodified electrode. Furthermore, the capabilities of electron transfer on these two electrodes were also investigated by electrochemical impedance spectroscopy. Under the optimized condition, a linear dynamic range of 2.5?×?10?6 to 1.5?×?10?4?mol?L?1 with detection limit of 9.4?×?10?7?mol?L?1 for GA is obtained in buffered solutions with pH 1.7. Finally, the proposed modified electrode was successfully used in real sample analysis. 相似文献
14.
A novel nitrite sensor was fabricated based on a graphene/polypyrrole/chitosan nanocomposite film modified glassy carbon electrode. The nanocomposite film was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The electron transfer behaviour of the modified electrodes was investigated in [Fe(CN)(6)](3-)/(4-) redox probe using cyclic voltammetry and electrochemical impedance spectroscopy. Differential pulse voltammetry and amperometry were used to study the electrochemical properties of the proposed sensor. Under optimum conditions, the sensor exhibited good reproducibility and stability for nitrite determination. Linear response was obtained in the range of 0.5-722 μM with a detection limit of 0.1 μM (S/N = 3) for nitrite determination. 相似文献
15.
Zhiqiang Gao Mingxian Zi Yimin Zhang Guangqiang Wang Zaofan Zhao 《Mikrochimica acta》1993,111(1-3):63-70
The electrocatalysis of nitrite in solutions at an inorganic film modified glassy carbon electrode was studied. The modifier was an electrodeposited thin inorganic film of the copper-heptacyanonitrosylferrate (CuHNF). Cyclic voltammetry of the modified electrode in a nitrite solution revealed that both oxidation and reduction of nitrite were catalyzed and the electrocatalytic currents were controlled by the diffusion of nitrite. Voltammetric and amperometric responses were investigated. When applied as an amperometric sensor in a flow injection system, the modified electrode permitted detection at — 0.55 V, over 500 mV lower than at the naked electrode surface. A linear response range extending from 1 × 10–6 to 1 × 10–3
M nitrite was obtained, with a detection limit of 3 × 10–7
M. The relative standard deviation for 50 repetitive injections with a 5 × 10–5
M nitrite solution was less than 4%. The procedure was applied to the determination of nitrite in saliva and nitrate. 相似文献
16.
Malena Karla Lombello Coelho Hanna Leijoto De Oliveira Fernanda Garcia De Almeida Keyller Bastos Borges César Ricardo Teixeira Tarley 《International journal of environmental analytical chemistry》2017,97(14-15):1378-1392
A simple and fast voltammetric method based on a new electrode composed of carbon paste electrode/bifunctional hybrid ion imprinted polymer (CPE/IIP) was developed for the quantification of Cd2+ in water samples. The voltammetric measurements by Differential Pulse Voltammetry were performed by using CPE containing 11.0 mg of IIP under phosphate buffer solution at concentration 0.1 mol L?1 and pH 6.5. The electrochemical method was carried out by Cd2+ preconcentration at ?1.2 V during 210 s, followed by anodic stripping. The performance of IIP towards Cd2+ determination was evaluated by comparison to non-imprinted polymer, whose detectability of IIP was much higher (45%). The sensitivity of the sensor was found to be 0.0105 µA/µg L?1. The limits of detection and limits of quantification were found to be 4.95 μg L?1 and 16.4 μg L?1, respectively. The developed method was successfully applied to Cd2+ determination in mineral, tap and lake water samples, whose results are in agreement with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) used as reference analytical technique. According to achieved results, the developed method can be used for routine analysis of quality control of water samples from different sources. 相似文献
17.
Mazloum-Ardakani M. Rajabi H. Mirjalili B. B. F. Beitollahi H. Akbari A. 《Journal of Solid State Electrochemistry》2010,14(12):2285-2292
In the present paper, the use of a novel carbon paste electrode modified by N,N′(2,3-dihydroxybenzylidene)-1,4-phenylene diamine (DHBPD) and TiO2 nanoparticles prepared by a simple and rapid method for the determination of hydrazine (HZ) was described. In the first part
of the work, cyclic voltammetry was used to investigate the redox properties of this modified electrode at various solution
pH values and at various scan rates. A linear segment was found with a slope value of about 48 mV/pH in the pH range 2.0–12.0.
The apparent charge transfer rate constant (k
s) and transfer coefficient (α) for electron transfer between DHBPD and TiO2 nanoparticles-modified carbon paste electrode were calculated. In the second part of the work, the mediated oxidation of
HZ at the modified electrode was described. It has been found that under optimum condition (pH 8.0) in cyclic voltammetry,
a high decrease in overpotential occurs for oxidation of HZ at the modified electrode. The values of electron transfer coefficients
(α) and diffusion coefficient (D) were calculated for HZ, using electrochemical approaches. Differential pulse voltammetry exhibited a linear dynamic range
from 1.0 × 10−8 to 4.0 × 10−6 M and a detection limit (3σ) of 9.15 nM for HZ. Finally, this method was used for the determination of HZ in water samples, using standard addition method. 相似文献
18.
In this work, an electrochemical sensor 1-phenyl-3-methyl-4-(2-furoyl)-5-pyrazolone/multiwalled carbon nanotubes/glassy carbon
electrode (GCE) was prepared for the determination of xanthine (XN) in the presence of an excess of uric acid. Cyclic voltammetry
and differential pulse voltammetry were used to characterize the electrode. The oxidation of XN occurred in a well-defined
peak having E
p 0.73 V in phosphate buffer solution of pH 6.0. Compared with the bare GCE, the electrochemical sensor greatly enhanced the
oxidation signal of XN with negative shift in peak potential about 110 mV. Based on this, a sensitive, rapid, and convenient
electrochemical method for the determination of XN has been proposed. Under the optimized conditions, the oxidation peak current
of XN was found to be proportional to its concentration in the range of 0.3~50 μM with a detection limit of 0.08 μM. The analytical
utility of the proposed method was demonstrated by the direct assay of XN in urine samples and was found to be promising at
our preliminary experiments. 相似文献
19.
Elisangela Muncinelli Caldas Eliana Weber de Menezes Tânia Mara Pizzolato Silvio Luis Pereira Dias Tania Maria Haas Costa Leliz Ticona Arenas Edilson Valmir Benvenutti 《Journal of Sol-Gel Science and Technology》2014,72(2):282-289
A mesoporous silica-based hybrid material composed of silica xerogel modified with an ionic silsesquioxane, which contains the 1,4-diazoniabicyclo[2.2.2]octane chloride group, was obtained. The silsesquioxane film is highly dispersed on the surface. This hybrid material was utilized to develop a carbon paste electrode (CPE) for determination of methyl parathion. Transmission FTIR, elemental analysis and N2 adsorption–desorption isotherms were used for characterization of the material. The electrochemical behavior of methyl parathion was evaluated by cyclic voltammetry and differential pulse voltammetry. It was observed a linear response to methyl parathion in the concentration range from 1.25 × 10?7 to 2.56 × 10?6 mol L?1 by employing the carbon paste electrode, in Britton–Robinson buffer solution (pH 6). The achieved detection limit (3 SD of the blank divided by the slope of calibration curve) was 0.013 µmol L?1 and sensitivity was 6.3 µA µmol L?1. This result shows the potentiality of this electrode for application as electrochemical sensor for methyl parathion. 相似文献
20.
A carbon nanotube paste (CNTP) electrode and a carbon nanotube paste/glucose oxidase (CNTP/GOx) electrode were prepared, and the electrochemiluminescent (ECL) behavior of luminol in the presence of glucose was investigated in detail at each of these electrodes. Compared to the classical carbon paste (CP) electrode, the CNTP electrode incorporating glucose oxidase greatly enhanced the response of the ECL sensor to glucose due to the electrocatalytic activity of the carbon nanotubes, the specificity of the enzymatic reaction, and the sensitivity of the luminol ECL reaction. Under optimal conditions, the electrode was found to respond linearly to glucose in the concentration range 1.0x10(-6) approximately 2.0x10(-3) mol/L, and the detection limit (defined as the concentration that can be detected at a signal-to-noise ratio of 3) was found to be a glucose concentration of 5.0x10(-7) mol/L. The method used to prepare the CNTP/GOx electrode was very convenient, and the electrode surface could be renewed in the case of fouling by simply polishing or cutting it to expose a new and fully active surface. The relative standard deviations (RSD) were found to be 6.8% and 8.9% for the CNTP electrode and the CNTP/GOx electrode (n=6). The electrode retained 95% of its initial response after two weeks. 相似文献