首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Aluminium, hydroxyquinolate can be quantitatively extracted by chloroform from an ammoniacal solution containing hydroxyquinoline, complexone and cyanide. Likewise extracted are titanium, vanadium, tantalum, niobium, uranium, zirconium, gallium, antimony, bismuth, indium and traces of beryllium. Aluminium can be separated from the first five elements by an extraction in ammoniacal solution containing hydrogen peroxide.Zirconium, gallium, bismuth and antimony can be eliminated by a cupferron extraction and indium by extraction with diethyldithiocarbamate. Beryllium is eliminated by performing an extraction with hydroxyquinoline at pH 5. The proposed method enables a practically specific photometrical determination of aluminium. Applications are given of the determination of trace and higher amounts of aluminium in steels, non-ferrous alloys and in glass.  相似文献   

2.
Kuchekar SR  Chavan MB 《Talanta》1988,35(5):357-360
Extraction of gallium(III), indium(III) and thallium(III) with n-octylaniline in chloroform at various concentrations of hydrogen halide acids (HCl, HBr, HI) has been studied and a scheme for their separation proposed. The procedure can be successfully applied to the separation and determination of gallium in presence of mercury, bismuth, manganese, zinc and lead; indium in presence of bismuth, antimony, lead, mercury, cadmium and zinc; and thallium in presence of mercury, cadmium, manganese, aluminium, tin and antimony. The advantage of the method is that the reagent can be recovered for reuse. The method is simple, rapid, and effects clear-cut separation.  相似文献   

3.
It has been shown that 2N sodium sulphide reagent can be successfully used in separating tellurium, molybdenum, antimony or rhenium from bismuth., platinum, gold, selenium, rhenium, arsenic, molybdenum or tellurium from cadmium; platinum, gold, selenium, rhenium, arsenic, molybdenum, tellurium or antimony from indium.It is not possible to separate quantitatively arsenic, platinum, gold or selenium from bismuth; antimony from cadmium; and tin from bismuth, cadmium or indium.  相似文献   

4.
1,2-Naphthoquinone-4-sulphonic acid-2-thiosemicarbazone (NQTS-4S) has been used as visual indicator in the complexometric determination of trivalent metal ions, aluminium, gallium, indium, bismuth and iron. Simultaneous determination of aluminium and iron and of aluminium and copper has also been carried out. The standard deviation and percentage errors have also been calculated.  相似文献   

5.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

6.
This work presents a disposable bismuth‐antimony film electrode fabricated on screen‐printed electrode (SPE) substrates for lead(II) determination. This bismuth‐antimony film screen‐printed electrode (Bi‐SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi‐SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen‐printed electrodes (BiSPE), antimony film screen‐printed electrodes (SbSPE) and bismuth‐antimony film glassy carbon electrodes (Bi‐SbGC). Under optimized conditions, the Bi‐SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 µg/L. The Bi‐SbSPE has been demonstrated successfully to detect lead in river water sample.  相似文献   

7.
Young RS 《Talanta》1976,23(2):125-130
Methods are reviewed for the determination of the following constituents of copper refinery slimes: aluminium, antimony, arsenic, barium, bismuth, calcium, cobalt, copper, gold, iron, lead, magnesium, manganese, molybdenum, nickel, platinum metals, selenium, silicon, silver, sulphur, tellurium, tin and zinc.  相似文献   

8.
Summary Systematic studies of gallium on Dowex-21K in malonate media are reported. On the basis of the value of the elution constant (E) it was separated from large number of metal ions. By selective sorption it was separated from the alkalis, alkaline earths, bismuth, thallium (I), mercury (II), iron (II) and germanium (IV). With water as eluant it was separated from cobalt, nickel, zinc, manganese and palladium, with ammonium chloride it was possible to separate it from copper, iron and vanadium, and with a specific eluant it was separated from lead and zirconium. Finally the sequential separation of gallium from thallium, aluminium and indium was accomplished.  相似文献   

9.
A study was undertaken to determine the interfering effects of arsenic, bismuth, germanium, lead, selenium, tin and tellurium on trace determination of antimony by atomic-absorption spectrometry with hydride-generation. A 1% NaBH(4) solution was used as reductant and a small amount of oxygen was added to the hydrogen produced, to support the combustion and atomization of SbH(3). The interference from selenium in the determination of antimony is removed if potassium iodide-ascorbic acid solution or copper sulphate is added to the sample solution. The interference of tin and tellurium can also be avoided by adding potassium iodide-ascorbic acid solution. A possible interference mechanism is discussed.  相似文献   

10.
Thallium(III), in the presence of other triply charged ions such as gallium, indium, bismuth and antimony in aqueous solution, was quantitatively and selectively extracted into 2-propanol/water phase by addition of NaCl ranging from 2.5 to 4.0 mol dm−3. The extraction efficiencies of gallium, indium, bismuth and antimony were much lower than that of thallium(III). Thus a maximal selective separation of thallium(III) from these elements could be attained using a 2-propanol/water mixture. Thallium(III) was extracted as TlCl4 with Na+. The detailed extraction mechanism in the presence of chloride, water in the organic phase and counter ions is discussed.  相似文献   

11.
2-Methyl-5-nitroso-8-hydroxyquinoline (2-methyl-5-nitroso-oxine), hitherto undescribed, has been prepared. The sensitivity and selectivity of this oxine derivative, together with 5-nitroso oxine, and 2-methyl-oxine towards aluminium, yttrium, gallium, indium and thallium(III) have been investigated. A gradation in selectivity is found. With oxine, precipitation occurs with all the above metals under the conditions of the test. With 2-methyl-oxine, precipitation occurs with all metals with the exception of aluminium. With 5-nitroso-oxine, no precipitation occurs with aluminium, yttrium, gallium and indium, and with 2-methyl-5-mtroso-oxine, no precipitation occurs with any metal in Group III B. A possible explanation for this behaviour is advanced.  相似文献   

12.
采用化学蒸气发生-四通道原子荧光光谱法测定了高纯金中的痕量砷、锑、铋和碲。用乙酸乙脂萃取分离金,水相还原后采用化学蒸气发生-四通道原子荧光光谱法测定高纯金中的痕量砷、锑、铋和碲。在最佳条件下,方法对As,Sb,Bi,Te的检出限分别为0.04,0.05,0.04,0.03 ng/mL(3σ);测定精密度分别为0.98,0.89,0.94,0.99%(对10 ng/mL As,Sb,Bi和Te混合标准,n=7)。方法对实际样品中的As,Sb,Bi,Te进行了同时测定,测定结果与标准方法无明显差异,各元素的加标回收率为95%~105%。  相似文献   

13.
Donaldson EM  Wang M 《Talanta》1986,33(3):233-242
Methods for determining ~ 0.2 mug g or more of silver and cadmium, ~ 0.5 mug g or more of copper and ~ 5 mug g or more of antimony, bismuth and indium in ores, concentrates and related materials are described. After sample decomposition and recovery of antimony and bismuth retained by lead and calcium sulphates, by co-precipitation with hydrous ferric oxide at pH 6.20 +/- 0.05, iron(III) is reduced to iron(II) with ascorbic acid, and antimony, bismuth, copper, cadmium and indium are separated from the remaining matrix elements by a single methyl isobutyl ketone extraction of their iodides from ~2M sulphuric acid-0.1M potassium iodide. The extract is washed with a sulphuric acid-potassium iodide solution of the same composition to remove residual iron and co-extracted zinc, and the extracted elements are stripped from the extract with 20% v v nitric acid-20% v v hydrogen peroxide. Alternatively, after the removal of lead sulphate by filtration, silver, copper, cadmium and indium can be extracted under the same conditions and stripped with 40% v v nitric acid-25% v v hydrochloric acid. The strip solutions are treated with sulphuric and perchloric acids and ultimately evaporated to dry ness. The individual elements are determined in a 24% v v hydrochloric acid medium containing 1000 mug of potassium per ml by atomic-absorption spectrophotometry with an air-acetylene flame. Tin, arsenic and molybdenum are not co-extracted under the conditions above. Results obtained for silver, antimony, bismuth and indium in some Canadian certified reference materials by these methods are compared with those obtained earlier by previously published methods.  相似文献   

14.
Donaldson EM 《Talanta》1989,36(5):543-548
A method for determining approximately 0.5, mug/g or more of cobalt, nickel and lead and approximately 3 mug/g or more of bismuth and indium in ores, soils and related materials is described. After sample decomposition and dissolution of the salts in dilute hydrochloric-tartaric acid solution, iron(III) is reduced with ascorbic acid and the resultant iron(II) is complexed with ammonium fluoride. Cobalt, nickel, lead, bismuth and indium are subsequently separated from iron, aluminium, zinc and other matrix elements by a triple chloroform extraction of their xanthate complexes at pH 2.00 +/- 0.05. After the removal of chloroform by evaporation and the destruction of the xanthates with nitric and perchloric acids, the solution is evaporated to dryness and the individual elements are ultimately determined in a 20% v/v hydrochloric acid medium containing 1000 mug/ml potassium by atomic-absorption spectrometry with an air-acetylene flame. Co-extraction of arsenic and antimony is avoided by volatilizing them as the bromides during the decomposition step. Small amounts of co-extracted molybdenum, iron and copper do not interfere.  相似文献   

15.
粗二氧化碲作为碲精炼或碲化工产品生产的重要原料,其中共存元素铜、铅、砷、锑、铋、硒含量的准确测定对于生产过程质量控制和贸易结算具有重要意义,但目前没有粗二氧化碲中铜、铅、砷、锑、铋、硒含量检测的标准分析方法。采用王水和饱和氟化氢铵分解试样,在王水和酒石酸介质中,选用Cu 327.393 nm、Pb 220.353 nm、Sb 217.582 nm、Bi 223.061 nm、As 193.696 nm、Se 196.026 nm为分析谱线,采用电感耦合等离子体发射光谱(ICP-AES)法测定粗二氧化碲中铜、铅、锑、铋、砷和硒含量。各元素校准曲线的相关系数均大于0.999;铜、铅、锑、铋、砷和硒的检出限分别为0.0004%、0.0005%、0.0006%、0.0007%、0.0004%和0.0007%,定量检出限分别为0.0012%、0.0016%、0.0020%、0.0025%、0.0013%和0.0025%。按照实验方法测定5个粗二氧化碲样品中铜、铅、锑、铋、砷和硒,测定结果的相对标准偏差(RSD,n=7)为0.79%~4.8%,加标回收率为96.0%~103%。方法简单,精密度和准确度较高,可用于测定粗二氧化碲中铜、铅、砷、锑、铋、硒含量。  相似文献   

16.
The interferences between arsenic and antimony on each other during the hydride generation atomic absorption spectrometry (HGAAS) determination of arsenic and antimony using a quartz tube atomizer (QTA) were examined. In order to eliminate or reduce such interferences by selective heat decomposition of arsine and stibine, a Pyrex adsorption U-tube trap containing glass wool was placed between the drying tube and the quartz tube atomizer. Although at 250 °C stibine decomposes and is held almost completely by the trap, arsine is also decomposed to an extent of 24% and, therefore, thermal decomposition is not useful to eliminate antimony interference on arsenic determination. The effect of coating the glass wool in the U-tube with antimony on the arsenic suppression of the antimony signal was studied. The results showed that the antimony coating in the U-tube could not hold arsenic effectively and its interference on the antimony signal could not be eliminated by this means. In the second part of the study, oxygen was supplied to the quartz tube atomizer during atomization in order to study the effect of supplying oxygen on the antimony signal and on the interference of arsenic in the antimony determination. Sensitivity was increased in the presence of oxygen and interferences of arsenic on antimony determination was decreased by about 10% when oxygen was supplied. It was also observed that the extent of interferences depended mainly on the interferent concentration rather than the analyte concentration.  相似文献   

17.
For elimination of copper interference in anodic stripping determinations of zinc at mercury and bismuth film electrodes gallium ions are usually added to the supporting electrolyte. In the presented studies novel ex situ formed gallium film electrode was applied for this purpose. The proposed electrode is less toxic than mercury one while the detection limit for zinc was lower than for bismuth film electrode following the same deposition time. The calibration graph for deposition time of 60 s was linear from 5 × 10−8 to 2 × 10−6 mol L−1. The determinations of zinc were carried out from undeaerated solutions. The proposed procedure was applied to zinc determination in certified reference material and tap water sample.  相似文献   

18.
Głab S  Hulanicki A 《Talanta》1989,36(4):519-524
The coulometric determination of carbon dioxide is based on the alkalimetric titration of the product of absorption of carbon dioxide in an organic solution of monoethanolamine. The processes occurring in various solvents have been investigated and optimized for analytical application. The protolytic reactions of 2-hydroxyethylcarbamic acid have been investigated in 2-propanol + 2, 5 and 10% water, dimethylformamide + 2% water, dimethylsulphoxide +5, 10 and 20% water. In coulometric generation of the base, 0.1M solutions of tetraethylammonium bromide in these solvents were used. The course of the titration was followed potentiometrically with glass and antimony indicator electrodes. From the titration curves the autoprotolysis constants of the mixed solvents and protonation constants of monoethanolamine in them were calculated. These constants and the concentration of monoethanolamine influence the size of the end-point break for the titrations. On this basis, optimal conditions for analysis have been selected and the total carbon content in samples of natural waters has been determined.  相似文献   

19.
Gallium is extractable as rhodamine B chlorogallate with benzene from 6M hydrochloric acid, and can be determined absorptiometrically or fluorimetrically in the extract. The interference of iron(III) is avoided by first separating gallium by extraction with isopropyl ether from hydrochloric acid solution containing titanous chloride. Traces of gallium can be determined in the presence of aluminium, indium, zinc, antimony, thallium, tungsten and other elements.  相似文献   

20.
Seventeen alkylated salicylidene-o-aminophenol derivatives were tested as fluorimetric reagents for aluminium, gallium, indium, scandium and beryllium. The aluminium, gallium and beryllium complexes are intensely fluorescent, and the scandium and indium complexes weakly fluorescent. The fluorescence properties of the aluminium, gallium and beryllium complexes were studied and conditions for the fluorimetric determination of these metals were established. 2-Hydroxy-4-methylaniline-N-2-hydroxy-4-methyl-benzylidene is a good reagent because of the reproducibility and sensitivity of the fluorescence. The optimal ranges for determination are 0.005–3 mg Al/25 ml, 0.1–7 μg Ga/25 ml and 0.02–7 μg Be/25 ml. In all cases, 1:1 metal—ligand complexes are formed. Optimal reaction conditions and interference studies are reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号