首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 510 毫秒
1.
Evmiridis NP 《Talanta》1989,36(3):357-362
A method for periodate determination is given which combines the rapidity of flow-injection analysis and the sensitivity of chemiluminescence (CL) detection. It is based on the CL emission generated during oxidation of pyrogallol by periodate, and gives a relative standard deviation of 3% and a detection limit of 350 ng with the instrumentation used. The method has been applied to determination of ethylene glycol, with a detection limit of 0.5 mumole. The accuracy of the method is quite good when the ethylene glycol is oxidized in unbuffered solutions, and the interference due to formaldehyde produced can be halved by prior addition of an appropriate amount of iodate. A throughput of 15 samples/min is possible, and the method is suitable for automation and remote control.  相似文献   

2.
建立了连续流动分析仪测定土壤中挥发酚含量的方法。称取5 g左右的土壤样品,以磷酸调节p H值为4,加入适量水并进行蒸馏,馏出液用连续流动分析仪测定挥发酚含量。在4.96~200μg/L范围内,挥发酚的质量浓度与相对峰高线性相关,线性方程为y=235.31x+51.6,相关系数r~2=0.999 8,挥发酚的检出限为1.24μg/L。取2种土壤样品分别进行6次平行测定,测定结果的相对标准偏差分别为1.52%,1.56%。对2种挥发酚标准样品进行测试,相对误差分别为1.90%,2.08%,加标回收率在87.8%~95.5%之间。该方法适合大批量样品的连续分析,且无需使用三氯甲烷,与传统方法相比更安全环保。  相似文献   

3.
Zsigrai IJ  Bartusz DB 《Talanta》1983,30(1):54-56
A method for coulometric thermometric precipitation titrations of chloride, bromide and iodide in molten calcium nitrate tetrahydrate at 55 degrees with coulometrically generated silver ions has been developed. The change in temperature during the titration is followed with the aid of a thermistor bridge coupled to a recorder. To minimize the temperature effect of the passage of current through the melt, two thermistors are connected in opposition in the bridge, with one in the anodic and the other in the cathodic cell compartment. Amounts of 62-80 mumole of halide have been determined with relative error below 0.4% and relative standard deviation less than 2.7%. The relative error in determination of 40 mumole of iodide was + 2%.  相似文献   

4.
建立了微波消解-电感耦合等离子体质谱(ICP-MS)法测定山东小麦中7种重金属元素(Cr、Ni、Cu、As、Cd、Pb、Zn)的方法,并对山东地区千余份小麦进行分析。结果表明,通过使用适宜的内标和He碰撞模式,7种重金属元素的方法检出限在0.0007~0.09 mg/kg,相对标准偏差(RSD,n=6)在10%以内,标准曲线线性关系良好,相关系数均大于0.999,方法用于国家有证标准物质(GSB-3、GSB-4、GSB24)的测定,结果与标准值相符。方法灵敏度高,重现性好,定量准确,可用于大批量小麦样品的测定。  相似文献   

5.
摘要:为了提升石墨炉原子吸收测定土壤样品中Cd和Pb的准确度和测试效率,对样品前处理和仪器测试等条件进行优化选择,确定了低温电热板消解样品时,硝酸、氢氟酸、高氯酸的三酸比例和复溶方式以及采用海光GGX-920型石墨炉原子吸收测定Cd和Pb的升温程序、样品和基体改进剂加入量等条件。应用选定方法条件分别对土壤标准物质GBW07403、GBW07449水系沉积物 GBW07309进行6次测定,测定值Cd的相对标准偏差RSD:2.49%~4.67%,相对误差RE:-2.31% ~ 2.22%,测定值Pb的相对标准偏差RSD:1.98%~ 2.54%,相对误差RE:-1.88% ~ 2.11%。此方法精密度和准确度均达到标准要求,是一种准确而快速的检测方法,适合大批量的环境样品检测。  相似文献   

6.
基于0.004 mol/L的柠檬酸介质中,痕量V(Ⅴ)催化KBrO3氧化甲基紫的褪色反应,建立了测定痕量V(Ⅴ)的动力学光度法。方法的检出限为1.23μg/L,线性范围为0~0.16μg/mL。讨论了酸度、反应物浓度、温度、反应时间、干扰离子等因素的影响,确定了该体系反应的最佳条件。在25 mL溶液中,测定2.0μg V(Ⅴ)的RSD为1.9%(n=11)。方法可用于测定小麦和苹果中的痕量V(Ⅴ),RSD为1.1%~2.7%,标准加入回收率为97.6%~99.0%。  相似文献   

7.
表面活性剂增敏催化光度法测定痕量铬(Ⅵ)   总被引:14,自引:0,他引:14  
报道了以十六烷基三甲基溴化铵为增敏剂,铬(Ⅵ)催化过氧化氢氧化间苯二酚蓝的反应,拟定了测定痕量铬(Ⅵ)的新催化光度法。本法由于添加了十六烷基三甲基溴化铵,灵敏度提高了19.8倍,测定铬(Ⅵ)含量的线性范围为0.02 ̄0.28mg/L,检出限为5.3×10^-3mg/L,相对标准偏差为1.1%(n=9),可用于水样中铬(Ⅵ)的测定。  相似文献   

8.
We report an accurate and reproducible DNA quantitation method using the polymerase chain reaction (PCR). The amount of PCR product is monitored after each PCR cycle by capillary electrophoresis. To ensure accurate quantitation, a non-amplified internal standard is added to each PCR-amplified electrophoresis sample to correct for variations in injection volume. Quantitation of the sample is based on the number of cycles necessary to generate a predetermined amount of PCR product. Duck hepatitis B virus genome was used as a model in this study. The genome was quantified with a linear relationship between cycle number and logarithm of sample DNA for amounts of sample DNA between 30 and 3.1 x 10(8) copies ( r(2)>0.999). The relative standard deviation for the corrected capillary electrophoresis signal was 2.7%, while the relative standard deviation for the overall assay was 3.0%. Results from a single-blind study generated a relative error of 1.3%.  相似文献   

9.
阳离子表面活性剂增敏催化光度法测定痕量铬(Ⅵ)   总被引:3,自引:0,他引:3  
基于存在增敏剂十六烷基三甲基溴化铵,铬(Ⅵ)催化过氧化氢氧化胭脂红酸的反应,拟定了测定痕量铬(Ⅵ)的新催化光度法。本法由于添加了十六烷基三甲基溴化铵,灵敏度提高3.3倍,测定铬(Ⅵ)含量的线性范围为0.005~0.16μg/mL,检出限为1.0×10-3μg/mL,相对标准偏差为0.5%(n=9),可用于测定水样中的铬(Ⅵ)。  相似文献   

10.
钡以及轻稀土元素氧化物对中、重稀土元素的干扰一直是质谱测试中存在的问题。建立了石墨粉垫底碳酸钠-硼酸混合熔剂熔融前处理样品,以103Rh为内标校正,一体化碰撞反应-电感耦合等离子体质谱仪法测定地质样品中稀土元素含量的方法。探讨了碳酸钠-硼酸混合熔剂熔融前处理样品注意事项、碰撞模式下碰撞气流量和离子透镜的参数的优化、干扰校正试验等问题,采用国家标准物质GBW07403、GBW07405、GBW07427、GBW07429验证,实验结果表明,各元素线性关系良好,相关系数均大于0.999,方法检出限在0.01~0.03mg/kg之间,相对误差为0.13%~7.1%,相对标准偏差为0.79%~6.59%,测试结果与标准值相吻合。对实际样品分析,得到平滑的球粒陨石归一化的稀土元素配分曲线,证明测定结果是合理可信的。该方法熔剂用量少,过程空白低,对器皿的侵蚀小,直接加热浸取,简化了操作过程,适用于大批量地质样品中稀土元素的测定。  相似文献   

11.
本文研究了金属卟啉-氧化剂-烷烃仿酶体系中的气相色谱定量测定方法,获得了该体系的最佳色谱条件和产物的相对重量校正因子。该方法的相对误差小于0.2%,相对标准偏差小于0.6%。对四种类型的金属卟啉催化的环己烷充氧化反应对动力学研究结果表明:反应物的生成量与反应时间呈良好的直线关系,其相关系数大于0.99。  相似文献   

12.
A simple titrimetric method for the determination of thiol and disulphide groups in biological samples with p-diethylaminophenylmercuric acetate as titrant, is suggested. Milligram amounts of cysteine (1-25 mg) are determined with a relative standard error not higher than 1%. The lowest detenninable amount of cysteine is 0.1 mg (relative standard deviation 3%). The accuracy and the sensitivity are the same as in amperometric titration with mercuric chloride. The method has been successfully used for the determination of thiol groups in various biological samples.  相似文献   

13.
建立高温燃烧水解-离子色谱法测定煤中氟和氯含量的方法。间隔测量煤标准物质和待测煤样,以煤标准物质特性量值的变化扣除系统漂移的影响,提高了测定结果的准确度和重复性。氟含量在0.042~2.018μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.995 8,检出限为0.011μg/g,测量结果相对标准偏差为6.32%(n=6);氯含量在0.046~2.292μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.999 8,检出限为0.010μg/g,测量结果的相对标准偏差为0.7%(n=6)。用该方法对煤标准物质进行测定,氟、氯测定结果与标准值一致。该方法简便快速,灵敏度高,结果准确,可用于煤中氟和氯含量的测定。  相似文献   

14.
A method using reversed-phase high-performance liquid chromatography with ultraviolet detection for the determination of ceterizine in serum is described. The method is sensitive down to 50 ng/ml (250-microliter loop). Sample preparation involves only serum deproteination with perchloric acid and injection of the centrifuged supernatant. Elution is at pH 2.5 with acetonitrile-methanol-0.05 M phosphate buffer (33:9:58, v/v) on a 25 cm x 4.6 mm I.D. Spherisorb S5 ODS2 column. Detection is at 211 nm, its lambda max. For levels above 300 ng/ml the serum sample size is 100 microliter and a 200-microliter sample is necessary for concentrations less than 300 ng/ml. At the 2 micrograms/ml concentration the intra-assay relative standard deviation is better than 2.2%, whilst the inter-assay deviation is 2.6% over eight samples. At 200 ng/ml the intra-assay relative standard deviation is 6% over seven samples. Detector response is linear from 100 ng/ml to 10 micrograms/ml (100-microliter loop).  相似文献   

15.
建立电感耦合等离子体发射质谱法测定钨矿石中钨华的含量。用氨水溶液对矿石样品进行浸取分离,将浸取液稀释10倍体积后测定,以3%盐酸溶液作为测定介质。WO3的质量浓度在0~100 ng/m L范围内与信号强度呈良好的线性关系,相关系数为0.999 9,方法检出限为0.5 ng/m L。用该方法对5个钨矿石样品和2个标准物质样品中的钨华进行测定,测定结果的相对标准偏差为2.15%~9.46%(n=12),且与经典方法极谱法测定结果的相对偏差小于10%。该方法快速、简便,精确度较高,可用于钨矿石中钨华的测定。  相似文献   

16.
Taga M  Kan M 《Talanta》1989,36(9):955-956
An atomic-absorption spectrophotometric method has been developed for the indirect determination of phosphorus. The calibration graph is linear over the range 0.025-0.2 mug of phosphorus. The relative standard deviation is 1.3% for 0.2 mug of phosphorus (6 replicates). The method has been applied to the determination of phosphate in natural water samples. The enhancement effect of acetone on the determination is discussed.  相似文献   

17.
The validation of a microbiological assay, applying cylinder plate method for determination of the activity of lomefloxacin in coated tablets is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, lomefloxacin was measured in concentrations ranging from 2.0 to 8.0 microg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 1.15%), and accurate (it measured the added quantities). The excipients did not interfere in the determination. It was concluded that the microbiological assay is satisfactory for quantitation of lomeflox tablets.  相似文献   

18.
流动注射-抑制化学发光法测定镱(Ⅲ)   总被引:1,自引:0,他引:1  
在碱性介质中, Yb(Ⅲ)对Luminol-KMnO4体系化学发光强度具有抑制作用, 据此建立了一种测定Yb(Ⅲ)的化学发光新方法. 在优化的实验条件下, 化学发光强度与Yb(Ⅲ)的浓度在4.0×10-7~1.0×10-4 mol/L范围内呈现出良好的线性关系. 其检测限(3σ)为5.0×10-8 mol/L, 对8.0×10-5 mol/L的Yb(Ⅲ)溶液进行测定, 相对标准偏差为3.9% (n=11). 本法已应用于合成样品中的镱的测定.  相似文献   

19.
大气沉降物中砷的测定传统方法干扰多,本文针对大气沉降物样品的复杂性,在样品中加入盐酸、硝酸、高氯酸于电热板上加热消解,能有效的消除大量有机质对测量结果的干扰,为大气沉降物研究工作提供更为精准的检测数据。该方法能有效的消除基体干扰,分析成本低,测定的精密度高、准确性好,相对标准偏差(RSD)低于2.0%,样品加标回收率高于90%。  相似文献   

20.
Wei Q  Duan C  Wang J  Ma H  Du B 《Annali di chimica》2006,96(7-8):451-461
A new catalytic kinetic spectrophotometric method for the determination of trace amount of chromium (VI) in microemulsion medium has been developed. The method is based on the catalytic effect of chromium (VI) on the oxidation of nuclear fast red in the presence of Tween-80 microemulsion and HAc-NaAc buffer solution (pH = 5.2). The linear ranges are in the range of 0 approximately 0.0480 microg mL(-1) of Cr (VI) at 528 nm and the detection limit is 1.56x10(-9)g mL(-1). The method has been applied in determination of Cr (VI) in water and food samples with satisfactory results. The relative standard deviation is less than 4.6 % and the recovery is 93.5 approximately 104 %.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号