首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
Triple isotope dilution mass spectrometry (triple IDMS) has been applied for the first time on protein quantification, especially on transferrin. Transferrin as an acute phase protein is a marker for several inflammation processes in the human body. Therefore, in Germany, the accurate and precise measurement of this important analyte is required. In this work, a new approach to triple IDMS is described and compared to double IDMS. Also, complete uncertainty budgets for both methods were set up to demonstrate the ability of this method to be used as a reference procedure. The relative expanded uncertainty (k?=?2) for triple IDMS (3.6 %) is smaller than the one for double IDMS (4.0 %). The content of transferrin found in the human serum reference material ERM-DA470k/IFCC ((2.41?±?0.08) g/kg) with both methods was in good agreement with each other and with the certificate. For triple IDMS ((2.426?±?0.086) g/kg) and for double IDMS ((2.317?±?0.092) g/kg), transferrin was determined. Although triple IDMS is a little more time consuming compared to double IDMS, there is the advantage that the isotopic composition of the spike material does not have to be determined. This is very useful especially in case of a marginal isotopic enrichment in the spike or problems with the accurate measurement of the spike isotope ratio.
Figure
Using triple instead of double species-specific IDMS helps to reduce the uncertainty and improves the reliability of the results, especially in cases where an accurate determination of the spike isotope ratio is difficult or impossible, because the spike ratio cancels from the equation  相似文献   

2.
An analytical method is presented based on reverse isotope dilution single detector inductively coupled plasma magnetic sector mass spectrometry (ID-ICP-SMS) and applied to the specific case of the certification of a (111)Cd enriched candidate Cd spike calibration material (nominal mass fraction 10 mg kg(-1) in 5% HNO3 solution). Uncertainty propagation was used as a tool for both determining the analytical approach and validating it. The robustness of close to "exact matching" reverse IDMS to correction of measured isotope intensities for multiplicative (mass discrimination) and (semi)additive effects (dead time, instrumental background, and isobaric interference) is discussed. The very low experimental relative standard deviation of the mean (0.08%) of eight replicate determinations indicated that all significant sources of uncertainty had probably been taken into account for the estimation of the final combined uncertainty statement (U(c) = 0.17%, k = 1). IRMM-621 was used as comparator. Uncertainties on IUPAC isotopic abundances of 111Cd and 112Cd, for the natural Cd solution involved between the two enriched materials, formed nearly 60% of U(c). The repeatability of the isotope ratio measurements contributed less than 10%. Correction for procedural blank necessitated somewhat unusual calculations (potential contamination of an enriched material with natural Cd). The procedure also involved a quadrupole based ICP-MS judged to be appropriate for the characterization of the isotopic composition. For comparison purposes, direct IDMS results are simulated using identical experimental input data. Finally, a significant background signal in the 106-116 mass region, observed only with the magnetic sector instrument, was attributed to argon based isobaric interferences.  相似文献   

3.
A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Copyright Crown copyright 2003. Reproduced with the permission of Her Majesty's Stationery Office.  相似文献   

4.
The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained.This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO(3)/H(2)O(2) microwave digestion. The thallium isotope amount ratio ( n((205)Tl)/ n((203)Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n((206)Pb)/ n((208)Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study "lead in wine" organised by the CCQM (Comité Consultatif pour la Quantité de Matière, BIPM, Paris; the highest measurement authority for analytical chemical measurements).The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=kxuc, k=2)The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R(206,B) of the blend between the enriched spike and the sample.  相似文献   

5.
提出了一种适用于微量气体定量分析的大小球三步同位素稀释质谱法,并给出其实验模型和不确定度理论分析结果。通过引入三步稀释过程,不涉及稀释剂的纯度、丰度、添加质量等方面的数据,仅需测定各步稀释剂质量之比,在其中的两步反稀释过程中使用了基标准纯物质,从而使微量气体的定量分析结果可溯源至基标准纯物质。该方法解决了已有同位素稀释质谱法在微量气体定量分析中的难题。  相似文献   

6.
Isotope ratio monitoring combined with n((13)C)/n((12)C) isotope dilution mass spectrometry (IRM/IDMS) provides results of low uncertainty of the order of 0.1% if it is applied to the analysis of simple mixtures as found in organic chemistry, even if only low (13)C spike additives to the sample are used. If the method is applied to the analysis of systems that require large-scale sample preparation prior to the measurement, such as the determination of glucose in serum, the results obtained exhibit a higher uncertainty that is comparable to that of the conventional gas chromatography/isotope dilution mass spectrometry (GC/IDMS) method. The reason for this observation is that the small contribution that the IRM/IDMS method makes to the uncertainty budget of the result is superimposed on a large contribution due to the sample preparation. It appears therefore that the IRM/IDMS method has no advantage over the conventional GC/IDMS method. However, if a series of measurements is carried out, and if a suitable experimental design is chosen, the IRM/IDMS method can provide valuable additional information. The influence of sample preparation on each individual result can be quantified as its deviation from the average value of all results of the series. From these data conclusions can be drawn for an improvement in sample preparation.  相似文献   

7.
Two reference materials, at relatively low and high concentrations (GBW08404 and GBW08405), for analysis of the mass fractions of Cd, Cr, Hg and Pb in polypropylene were developed. The reference materials were prepared by doping blank polypropylene base material with Cd, Cr, Hg and Pb in the form of oxides, salts or pigments. Homogeneity and stability studies were performed by inductively coupled plasma mass spectrometry. The certification of the four analytes was carried out by isotope-dilution mass spectrometry (IDMS) with microwave-assisted digestion. Combined uncertainties were calculated from the IDMS uncertainty evaluation budget and the uncertainty of the homogeneity. The mass fractions of Cd, Cr, Hg and Pb of the two certified reference materials (CRMs) were from 8 to 1,000 mg kg−1. The two samples were also used in an interlaboratory comparison scheme in which National Institute of Metrology, China, National Metrological Institute of Japan and Korea Research Institute of Standards and Science participated. The agreement of the comparison results proved that the certification procedure of the CRMs is valid and that the certified values of Cd, Cr, Hg and Pb are accurate and reliable.  相似文献   

8.
Species-specific (SS) isotope dilution analysis with gel electrophoresis (GE)-laser ablation (LA)-ICP-MS is a promising technique for the quantification of particular metal-binding proteins in biological samples. However, unavailable isotopically enriched spike and metal losses in GE separation are main limitations for SS-isotope dilution PAGE-LA-ICP-MS. In this study, we report for the first time the absolute quantification of transferrin (Tf) and albumin (Alb) in human serum by non-denaturing (native) GE combined with species-unspecific isotope dilution mass spectrometry (IDMS). In order to achieve a homogeneous distribution of both protein and isotope-enriched spike (simulated isotope equilibration), immersing the protein strips with 34S spike solution after gel electrophoresis was demonstrated to be an effective way of spike addition. Furthermore, effects of immersion time and 34S spike concentration were investigated to obtain optimal conditions of the post-electrophoresis isotope dilution method. The relative mass of spike and ablated sample (msp/msam) in IDMS equation was calculated by standard Tf and Alb proteins, which could be applied to the quantification of Tf and Alb in ERM-DA470k/IFCC for method confirmation. The results were in agreement with the certified value with good precision and small uncertainty (1.5–3%). In this method, species-specific spike protein is not necessary and the integrity of the heteroatom-protein could be maintained in sample preparation process. Moreover, the application of species-unspecific isotope dilution GE-LA-ICP-MS has the potential to offer reliable, direct and simultaneous quantification of proteins after conventional 1D and 2D gel electrophoretic separations.  相似文献   

9.
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time‐consuming derivatization for gas chromatography–mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid‐phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization–quadrupole time‐of‐flight mass spectrometry (APCI‐Q‐TOF‐MS) that does not require derivatization. Solid‐phase extraction‐isotope dilution mass spectrometry (SPE‐IDMS) involves pre‐equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i‐Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co‐eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI‐Q‐TOF‐MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
In nuclear safeguards, precise and accurate isotopic analyses are needed for two major elements from the nuclear fuel cycle: uranium and plutonium. This can be achieved by Isotope Dilution Mass Spectrometry (IDMS), which is one of the most reliable analytical techniques for the determination of plutonium amount content to a high level of accuracy. In order to achieve reliable isotope measurements isotopic reference materials with certified amount of plutonium and isotopic composition are required. At the Institute for Reference Materials and Measurements (IRMM) various plutonium spike reference materials for isotopes 239Pu, 240Pu, 242Pu and 244Pu are available. This enabled the setup of an inter-calibration campaign inter-linking selected plutonium spikes on a metrological basis applying state-of-the-art measurement procedures. The aim of this campaign is threefold: firstly to perform measurements on selected plutonium spike isotopic reference materials for quality control purposes, secondly to verify the amount content and the isotopic composition of the recently produced IRMM-1027m large sized dried (LSD) spikes and thirdly to demonstrate IRMM’s measurement capabilities for plutonium analysis via external quality tools. The obtained results using various spike isotopic reference materials will be presented and discussed in this paper. The measurement uncertainties of the IDMS results were calculated according to the guide to the expression of uncertainty in measurement (GUM).  相似文献   

11.
Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution was used in connection with ICP-MS by external calibration, which has the advantage of a simple sample preparation technique but introduces high amounts of the silver matrix into the mass spectrometer. On the other hand, isotope dilution mass spectrometry (IDMS) with an enriched 99Ru spike solution was applied for ICP-MS and NTI-MS measurements, respectively, in connection with a significant reduction of the matrix by AgCl precipitation. In these cases loss of ruthenium by the AgCl precipitate has no effect on the analytical result. The results of the different methods agreed usually well analysing ruthenium traces in the range of 0.1–10 μg per gram emulsion. The detection limits obtained were 4 ng/g for ICP-IDMS, 20 ng/g for NTI-IDMS, and 15 ng/g for ICP-MS with external calibration. Differences in the results between the different methods could mainly be attributed to sample inhomogeneities. ICP-IDMS with silver matrix reduction by AgCl precipitation is recommended as a routine method, NTI-IDMS with the corresponding sample treatment as a calibration method.  相似文献   

12.
This critical review discusses the conditions under which inductively coupled plasma–isotope dilution mass spectrometry (ICP–IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP–IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP–IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP–IDMS analysis. Coupling of gas or liquid chromatography with species-specific ICP–IDMS, however, enables validation of analytical methods involving species transformations which cannot easily be performed by other methods. The potential and limitations of ICP–IDMS are demonstrated by recently published results and by some unpublished investigations by our group. It has been shown that possible loss of silicon as volatile SiF4 during decomposition of a sample by use of hydrofluoric acid has no effect on trace silicon determination if the isotope-dilution step occurs during digestion in a closed system. For powder samples, laser ablation ICP–IDMS can be applied with an accuracy comparable with that only available from matrix-matched standardization, whereas the accuracy of electrothermal vaporization ICP–IDMS was strongly dependent on the element determined. The significance of easy synthesis of isotope-labeled spike compounds for species-specific ICP–IDMS is demonstrated for monomethylmercury and Cr(VI). Isotope-exchange reactions between different element species can prevent the successful application of ICP–IDMS, as is shown for iodinated hydrocarbons. It is also shown for monomethylmercury that species transformations during sample-pretreatment steps can be followed by species-specific ICP–IDMS without loss of accuracy. A relatively simple and time-efficient procedure for determination of monomethylmercury in environmental and biological samples is discussed. The method, which entails a rapid microwave-assisted isotope dilution step and in-situ extraction of the derivatized species, has good potential for routine application in the future.  相似文献   

13.
An important but commercially unavailable compound isotopically enriched monoethylmercury chloride (C2H5201HgCl), has been synthesized from commercially available 201HgO (98.11% enriched isotopic purity) and tetraethyltin. The required synthesis time is 1 h at 90 °C, and the product is the single product of monoethylmercury chloride, yielding more than 95% as 201Hg in C2H5201Hg+ (98.19 ± 0.22% enriched isotopic purity). The synthesized product was analyzed with high‐performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (HPLC‐ICP‐MS) to determine its concentration, isotopic composition and purity. The synthetic isotopically enriched monoethylmercury synthesized can be used in speciated isotope dilution mass spectrometry (SIDMS) and isotope dilution mass spectrometry (IDMS) analyses as a standard. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
A simple procedure for the synthesis of an important standard, isotopically enriched methylmercury, which is not commercially available, has been established successfully. The isotopically enriched standard synthesized is utilized in conventional isotope dilution mass spectrometry (IDMS), as well as in speciated IDMS (SIDMS), for determination of the true concentration of methylmercury in environmental samples. The CH3201Hg+ standard has been synthesized from commercially available 201HgO and tetramethyltin. The synthesis time required is 1 h at 60°C. The product is highly pure, yielding more than 90% as 201Hg in CH3201Hg+. Hazardous dimethylmercury does not occur during this synthesis procedure. The product synthesized was analyzed using high‐performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (ICP‐MS) and ICP‐MS alone in order to determine its concentration, isotopic composition and purity. The stability of the product was also evaluated for over 6 months and found to be stable at 4°C in the dark. The isotopically enriched methylmercury synthesized can be used in SIDMS and IDMS analyses as a standard. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6–21% for pressed pellets and 3–21% for fused solids were obtained from n = 3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches.  相似文献   

16.
Isotope-dilution mass spectrometry (IDMS) is considered to be a method without significant correction factors. It is also believed that this method is well understood. But unfortunately a large number of different uncertainty budgets have been published that consider different correction factors. These differences lead to conflicting combined uncertainties especially in trace analysis. It is described how the known correction factors must be considered in the uncertainty budget of values determined by IDMS combined with ICP-MS (ICP-IDMS). The corrections applied are dead time, background, interference, mass discrimination, blank correction and air buoyancy.IDMS measurements consist always of a series of isotope abundance ratio measurements and can be done according to different measurement protocols. Because the measurement protocols of IDMS are often rather sophisticated, correlations of influence quantities are difficult to identify. Therefore the measurement protocol has to be carefully considered in the specification of the measurand and a strategy is presented to properly account for these correlations. This will be exemplified for the estimation of mass fractions of platinum group elements (PGEs) and Re in the geological reference material UB-N (from CRPG-CNRS, Nancy in France) with ICP-IDMS. The PGEs with more than one isotope and the element Re are measured with on-line cation-exchange chromatography coupled to a quadrupole ICP-MS. All contents are below 10 µg kg–1. Only osmium is separated from the matrix by direct sparging of OsO4 into the plasma. This leads to transient signals for all PGEs and Re. It is possible to estimate the combined uncertainties and keep them favourably small despite the low contents, the transient signals and the sophisticated correction model.  相似文献   

17.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

18.
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by high-performance liquid chromatography (HPLC) with an on-line detection using the Am and Cm α-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the 241Am/238U and 244Cm/238U ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique. Received: 30 November 1998 / Revised: 8 January 1999 / Accepted: 12 January 1999  相似文献   

19.
In post column online isotope dilution mass spectrometry (IDMS), the stability of the spike mass flow is a key element. Changes in viscosity or fluctuations in the pump rate of the peristaltic pump may affect the results of post column online IDMS measurements. It was shown by simulating random fluctuations and studying the changes in the resulting integrals of the isotope ratio chromatogram of the sample that even small fluctuations, observable when using peristaltic pumps, can influence the result and especially its uncertainty. The use of a balance to continuously monitor the mass flow of the spike during the measurement which we presented in a previous publication allows now to correct the isotope ratio chromatogram for these fluctuations. Subsequently, the simulated effect was verified experimentally for the determination of Se-Met in the human serum reference material BCR 637, where the corrected mass fraction was plainly closer to the mass fraction obtained by species specific IDMS. Additional attention was paid to the fact that there is a time shift between the observation of the fluctuations in the pump rate and the detection of these fluctuations in the ICP-MS.  相似文献   

20.
Swart C  Rienitz O  Schiel D 《Talanta》2011,83(5):151-1551
An alternative post column online double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) method was developed. The resulting equation allows a straightforward calculation of the mass concentration of the analyte in the sample from the measured isotope ratio chromatogram. The use of a balance to determine and monitor the mass flow of the spike and a solution of the species under investigation as the reference are the two core components of this new method. Changes in the viscosity of the system eluent-analyte-spike will not affect the results due to the direct determination of the mass flow rate. The use of the species under investigation as the reference makes the method independent of the injected volume. To simplify matters, the integration of the isotope ratio chromatogram was done with Excel using Simpson's rule instead of sophisticated programs for transformation and integration. The advantages of the new approach were demonstrated with the help of the determination of selenomethionine in the selenized yeast reference material SELM-1 with liquid chromatography coupled to ICP-MS (HPLC ID-ICP-MS) applying the new online double IDMS method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号