首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Solid-phase microextraction of polychlorinated biphenyls   总被引:8,自引:0,他引:8  
The extraction and analysis of 21 polychlorinated biphenyls (PCBs) ranging from di- to decachlorobiphenyls in ocean, wetland and leachate water samples were achieved using solid-phase microextraction (SPME) with a 100-μm poly(dimethylsiloxane) (PDMS) fiber and gas chromatography–electron-capture detection (GC–ECD). Severe carryover between samples (e.g., 20%) occurs on both stir bars and the SPME fibers demonstrating that it is important to use a new stir bar for each sample, as well as to perform SPME–GC blanks between samples to avoid quantitative errors. The equilibrium partitioning coefficients of individual PCB congeners between PDMS and water were found to be surprisingly different compared to their octanol–water partitioning coefficient (Kow), demonstrating that Kow cannot be used to estimate the partitioning behavior of PCBs in the SPME process. Using a 15-min SPME extraction, SPME analysis with GC–ECD was linear (r2≥0.97) from 5 pg/ml to the solubility limit of each congener. Concentrations in water samples obtained by 15-min SPME extractions compared favorably with those obtained by toluene extractions, demonstrating that SPME combined with GC is a useful technique for the rapid determination of PCBs in water samples.  相似文献   

2.
王树涛  王炎  尤宏  梁志华 《色谱》2004,22(5):547-550
利用自制的有机硅树脂胶粘剂和粉状活性炭制成活性炭涂层萃取头。该萃取头富集能力强,对氯仿、四氯化碳、三氯乙烯、四氯乙烯4种卤代烃化合物的富集率达到13.8~18.7倍;热稳定性好,最高使用温度可达290 ℃;使用寿命长,250 ℃解吸条件下可反复使用140次以上。上述4种化物固相微萃取-气相色谱分析的结果表明,方法的最低检出质量浓度为0.008~0.05 μg/L。采用该萃取头对含有该4种卤代烃化合物的实际水样进行了SPME-GC分析,4种化合物的回收率为95.5%~104.6%。  相似文献   

3.
The applicability of the retention index system to hcadspacc solid phase microextraxtion (HS–SPME) was investigated. In headspace SPME, the two equilibria gas phase/matrix and fiber coating/gas phase have to he considered. In this paper the equilibrium fiber coating/gas phase is discussed separately to characterize it more detailed and to investigate several methodical aspects. Therefore, the different distribution constants Kfiber/gas of n-alkanes, which were used for reference compounds, were related to their Kováts retention indices. The validity of the derived linear relationship log Kfiber/gas versus retention index I is demonstrated for various examples. This relation is helpful for the assessment of distribution constants of substances not available and for the choice of a suitable fiber coating. Furthermore, quantification of analytes in the gas phase can be done without authentic substances.  相似文献   

4.
Solid-phase microextraction (SPME) followed by gas chromatography/mass spectrometry (GC/MS) was used for the detection of liver cancer volatile biomarkers. Headspace SPME conditions (fiber coating, extraction temperature and extraction time) and desorption conditions were optimized and applied to the determination of volatiles in human blood. Between the liver cancer group (n = 19) and the normal group (n = 18), positive rates of 19 volatile compounds among the total of 47 detected were found to be different with statistical significance (p < 0.05, chi-squared test). We suggested hexanal, 1-octen-3-ol and octane, of the 19 compounds, as biomarkers of liver cancer with clinical diagnostic value. The sensitivity and specificity of 94.7% and 100% for hexanal, 84.2% and 100% for 1-octen-3-ol, and 89.5% and 100% for octane were obtained, respectively, after the cutoff values had been properly established. These results show that SPME-GC/MS is a simple, rapid and sensitive method for the investigation of volatile disease markers in human blood.  相似文献   

5.
The preparation, properties and application of carbon fibers for SPME   总被引:1,自引:0,他引:1  
Gierak A  Seredych M  Bartnicki A 《Talanta》2006,69(5):1079-1087
The conditions of preparation of new types of carbon fibers for solid phase micro extraction (SPME) prepared by methylene chloride pyrolysis (at 600 °C) on the quartz fiber (100 μm) as well as by supporting synthetic active carbon (prepared especially for this purposes) supported in a special epoxide-acrylic polymer is described. The properties of such carbon fibers for SPME were defined by determination of the partition coefficient of the tested substances (i.e., benzene, toluene, xylenes, trichloromethane and tetrachloromethane) and by the microscopic investigations with the application of the optical and scanning electron microscope.

The obtained carbon SPME fibers were applied to the analysis of some volatile organic compounds from its aqueous matrix. During chromatographic GC test, at the investigated SPME carbon fibers, we obtained different but mostly high partition coefficients for the determined compounds (Kfs from 120 for trichloromethane up to 11,500 for tetrachloromethane).

Owing to the high partition coefficients of the studied substances obtained on carbon fibers, it was possible to do the analysis of organic substances occurring in trace amounts in different matrices. In this paper, we present the analysis of BTX contents in the petrol analyzed with the application carbonized with CH2Cl2 SPME fiber (C1NM) and a headspace over the petrol sample (concentration of each BTX g/dm3).  相似文献   


6.
Optimization of the SPME device design for field applications   总被引:2,自引:0,他引:2  
Solid Phase Microextraction (SPME) is a powerful tool for field investigations. With the help of a portable gas chromatograph it can be used for fast analysis directly on-site, or it can be utilized for field sampling and then transported to the laboratory for instrumental analysis. In the latter case, it is important for the reliability of the results that losses of volatiles and contamination of the fiber during storage and transport are minimized. A number of dedicated devices, designed and built for SPME field sampling and storage, have been developed and tested. Sealing capacity of the prototypes was investigated by storing compounds ranging in volatility from methylene chloride to 1,3-dichlorobenzene on selected SPME fibers (100 μm PDMS, 65 μm PDMS/DVB and 75 μm Carboxen/PDMS) at different temperatures. Significant differences were noticed in storage capacity from coating to coating. A comparison between the field samplers optimized in this study and the field sampler commercially available from Supelco revealed advantages and limitations of each of the designs. A gas-tight valve syringe (50 μL SampleLock by Hamilton), modified in order to accommodate the SPME fiber, had the best storage capacity for very volatile compounds. With this device, over 80% of the initial amount of methylene chloride was retained by the 100 μm PDMS fiber after 24 h of refrigerated storage, which is a very good result considering that the PDMS coating is characterized by very low storage capacity for volatiles. Field sampling investigations with the SPME prototypes confirmed the usefulness of these devices for field analysis. Received: 9 November 1998 / Accepted: 15 January 1999  相似文献   

7.
Optimization of the SPME device design for field applications   总被引:1,自引:0,他引:1  
Solid Phase Microextraction (SPME) is a powerful tool for field investigations. With the help of a portable gas chromatograph it can be used for fast analysis directly on-site, or it can be utilized for field sampling and then transported to the laboratory for instrumental analysis. In the latter case, it is important for the reliability of the results that losses of volatiles and contamination of the fiber during storage and transport are minimized. A number of dedicated devices, designed and built for SPME field sampling and storage, have been developed and tested. Sealing capacity of the prototypes was investigated by storing compounds ranging in volatility from methylene chloride to 1,3-dichlorobenzene on selected SPME fibers (100 μm PDMS, 65 μm PDMS/DVB and 75 μm Carboxen/PDMS) at different temperatures. Significant differences were noticed in storage capacity from coating to coating. A comparison between the field samplers optimized in this study and the field sampler commercially available from Supelco revealed advantages and limitations of each of the designs. A gas-tight valve syringe (50 μL SampleLock by Hamilton), modified in order to accommodate the SPME fiber, had the best storage capacity for very volatile compounds. With this device, over 80% of the initial amount of methylene chloride was retained by the 100 μm PDMS fiber after 24 h of refrigerated storage, which is a very good result considering that the PDMS coating is characterized by very low storage capacity for volatiles. Field sampling investigations with the SPME prototypes confirmed the usefulness of these devices for field analysis. Received: 9 November 1998 / Accepted: 15 January 1999  相似文献   

8.
The applicability of solid phase microextraction (SPME) to the headspace analysis of monoterpene hydrocarbons from conifer needles was examined. To this end, the influences of fiber coating thickness, exposure time, and exposure temperature on the enrichment of the different monoterpene hydrocarbons were investigated. The distribution constants between polydimethylsiloxane fiber and gas phase at a given temperature were found to be very different. A relation is therefore derived to calculate the distribution constants of substances not available from their Kováts retention indices. A slightly different approach could be the use of so-called “relative distribution factors”, not considering the actual volume of fiber coating. In view of the different enrichment conditions in SPME as well as the general problems of headspace analysis, a comparison with a completely different method of sample preparation is presented. Furthermore, some applications of SPME to the analysis of monoterpenes from pine needles are given.  相似文献   

9.
A solid-phase microextraction (SPME) procedure for the determination of four haloanisoles (2,4,6-trichloroanisole, 2,3,4,6-tetrachloroanisole, pentachloroanisole and 2,4,6-tribromoanisole), as well as their precursor halophenols (2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, pentachlorophenol and 2,4,6-tribromophenol), involved in the presence of cork taint in wine, was developed. Firstly, analytes were concentrated on a SPME fiber, and then halophenols were derivatised using N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA). The compounds were desorbed for 5 min in the gas chromatography injector port and then determined with an electron capture detector. The influence of different parameters on the efficiency of extraction (volume of sample, type of fibre coating and time) and derivatisation (time, temperature and volume of MSTFA) steps was evaluated. Polyacrylate (PA) was selected as the extraction fiber, optimised parameters for SPME were 10 ml of wine, temperature 70 degrees C and extraction time 60 min. The optimal conditions identified for the derivatisation step were temperature 25 degrees C, reagent volume 50 microl and extraction time 25 min. Under optimal conditions, the proposed method showed satisfactory linearity, precision and detection limits. The method was applied successfully to the analysis of red wine samples. To our knowledge, this is the first time that headspace (HS) SPME combined with on-fiber derivatisation has been applied to determine cork taint responsible compounds in wine.  相似文献   

10.
11.
霍巨垣  欧阳钢锋  陈丽琼  王欣 《色谱》2016,34(6):615-620
建立了顶空固相微萃取结合气相色谱-质谱联用技术测定玩具中10种可迁移有机锡化合物的方法。玩具材料经0.07 mol/L HCl浸泡2 h后,使用醋酸-醋酸钠缓冲溶液将浸泡液的pH值调至4.7,然后加入四乙基硼化钠将浸泡液中的有机锡化合物乙基化,在振荡条件下用100 μ m聚二甲基硅氧烷(PDMS)纤维进行顶空固相微萃取,萃取完成后将纤维插入气相色谱进样口进行热解吸,使用DB-5毛细管柱对10种有机锡化合物进行分离。10种有机锡化合物的检出限为0.5~5 μg/kg。两个加标水平(0.500 μg/L和5.00 μg/L)下的回收率分别为80.7%~118.7%和86.2%~120.5%,RSD均低于15%。应用该方法测定了玩具可触及材料(包括涂层、织物、塑料、木料)中的可迁移有机锡化合物。该方法简便、快速、灵敏度高,不需使用有毒有机溶剂,绿色环保。  相似文献   

12.
Solid-phase microextraction (SPME) with a disposable ionic liquid (IL) coating was developed for headspace extraction of benzene, toluene, ethylbenzene, and xylenes (BTEX) in paints. The SPME fiber was coated with IL prior to every extraction, then the analytes were extracted and desorbed on the injection port of gas chromatography, and finally the IL coating on the fiber was washed out with solvents. The coating and washing out of IL from the fiber can be finished in a few minutes. This disposable IL-coated fiber was applied to determine BTEX in water-soluble paints with results in good agreement with that obtained by using commercially available SPME fibers. For all the four studied paints samples, the benzene contents were under the detection limits, but relatively high contents of toluene, ethylbenzene and xylenes (56-271 microg g(-1)) were detected with spiked recoveries in the range of 70-114%. Compared to the widely used commercially available SPME fibers, this proposed disposable IL-coated fiber has much lower cost per determination, comparable reproducibility (RSD < 11%), and no carryover between each determination. Considering that IL possess good extractability for various organic compounds and metals ions, and that task-specific IL can be designed and synthesized for selective extraction of target analytes, this disposable IL coating SPME might has great potential in sample preparation.  相似文献   

13.
A fast and simple screening procedure using solid‐phase microextraction and gas chromatography‐mass spectrometry (SPME‐GC‐MS) in full‐scan mode for the determination of volatile organic compounds (VOC) is presented. The development of a fast and simple screening technique for the simultaneous determination of various volatiles is of great importance, because of their widespread use, frequent occurrence in forensic toxicological questions and the fact that there is often no hint on involved substances at the crime scene. To simulate a screening procedure, eight VOC with different chemical characteristics were chosen (isoflurane, halothane, hexane, chloroform, benzene, isooctane, toluene and xylene). To achieve maximum sensitivity, variables that influence the SPME process, such as type of fiber, extraction and desorption temperature and time, agitation and additives were optimized by preliminary studies and by means of a central composite design. The limits of detection and recoveries ranged from 2.9 µg/l (xylene) to 37.1 µg/l (isoflurane) and 7.9% (chloroform) to 61.5% (benzene), respectively. This procedure can be used to answer various forensic and toxicological questions. The short time taken for the whole analytical procedure may make its eventual adoption for routine analysis attractive. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
The simultaneous determination of several odorous trichlorobromophenols in water has been carried out by an in-sample derivatization headspace solid-phase microextraction method (HS-SPME).The analytical procedure involved their derivatization to methyl ethers with dimethyl sulfate/NaOH and further HS-SPME and gas chromatography-mass spectrometry (GC/MS) determination. Parameters affecting both the derivatization efficiency and headspace SPME procedures, such as the selection of the SPME fiber coating, derivatization–extraction time and temperature, were studied. The commercially available polydimethylsiloxane (PDMS) 100 μm and Carboxen-polydimethylsiloxane-divinylbenzene (CAR-PDMS-DVB) fibers appeared to be the most suitable for the simultaneous determination of these compounds. The precision of the HS-SPME/GC/MS method gave good relative standard deviations (RSDs) run-to-run between 9% and 19% for most of them, except for 2,5-diCl-6-Br-phenol, 2,6-diCl-3-Br-phenol and-2,3,6-triBr-phenol (22%, 25% and 23%, respectively). The method was linear over two orders of magnitude, and detection limits were compound dependent but ranged from 0.22 ng/l to 0.95 ng/l. The results obtained for water samples using the proposed SPME procedure were compared with those found with the EPA 625 method, and good agreement was achieved. Therefore, the in-sample derivatization HS-SPME/GC/MS procedure here proposed is a suitable method for the simultaneous determination of odorous trichlorobromophenols in water.  相似文献   

15.

A highly porous fiber coating material was prepared and functionalized with 3-amino propyl triethoxysilane (APTES) on hexagonally ordered nanoporous silica (SBA-15). Applicability of this coating was assessed employing a laboratory made solid-phase microextraction (SPME) device and gas chromatography–mass spectrometry for the simultaneous sampling and determination of trace polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions. A one at the time optimization strategy was applied to investigate and optimize important extraction parameters such as extraction temperature, extraction time, ionic strength and sonication time. In the optimum conditions, the relative standard deviations for deionized water, spiked with selected PAHs were between 3.3 and 7.7% (n = 3), and detection limits for the studied compounds were 4.2 and 26.1 pg mL−1. No significant change was observed in the extraction efficiency of the new SPME fiber, over 50 extractions. The proposed method was successfully applied to the extraction and determination of PAHs in the waste water samples.

  相似文献   

16.
Nielsen AT  Jonsson S 《The Analyst》2002,127(8):1045-1049
A method was developed for the simultaneous determination of the following nine volatile sulfur compounds in gas samples: carbon disulfide, carbonyl sulfide, ethyl sulfide, ethyl methyl sulfide, hydrogen sulfide, isopropanethiol, methanethiol, methyl disulfide and methyl sulfide. The target compounds were preconcentrated by solid-phase microextraction (SPME) and determined by gas chromatography combined with mass spectrometry. Experimental design was employed to optimize the extraction time and temperature and concurrent detection of the nine compounds was achieved by using an SPME fiber coated with Carboxen-polydimethylsiloxane (75 microns). Detection limits ranged from 1 ppt (v/v) for carbon disulfide to 350 ppt (v/v) for hydrogen sulfide and calibration functions were linear up to 20 ppb (v/v) for all the compounds investigated.  相似文献   

17.
A highly porous fiber coating material was prepared and functionalized with 3-amino propyl triethoxysilane (APTES) on hexagonally ordered nanoporous silica (SBA-15). Applicability of this coating was assessed employing a laboratory made solid-phase microextraction (SPME) device and gas chromatography?Cmass spectrometry for the simultaneous sampling and determination of trace polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions. A one at the time optimization strategy was applied to investigate and optimize important extraction parameters such as extraction temperature, extraction time, ionic strength and sonication time. In the optimum conditions, the relative standard deviations for deionized water, spiked with selected PAHs were between 3.3 and 7.7% (n = 3), and detection limits for the studied compounds were 4.2 and 26.1 pg mL?1. No significant change was observed in the extraction efficiency of the new SPME fiber, over 50 extractions. The proposed method was successfully applied to the extraction and determination of PAHs in the waste water samples.  相似文献   

18.
Experimental determination of oil-water partition coefficients often poses difficulties associated with emulsion formation. The aim of this work was to find an appropriate technique for determination of oil–water partition coefficients of polar, nonvolatile compounds. Two different methods were tested. The first method used a “silicone membrane equilibrator.” For the second method, solid-phase microextraction (SPME) fibers with a polyacrylate (PA) coating were used as a passive sampler. With both methods, oil–water partition coefficients for 14 compounds with polar functional groups were determined at 37 °C with good repeatability (standard deviation 0.11 log units or lower). The partition coefficients determined with the silicone membrane equilibrator method ranged from 0.50 to 3.49 log units. The oil–water partition coefficients obtained with the PA-SPME passive sampling approach were significantly higher than those obtained with the silicone membrane equilibrator method for nine of 14 compounds. The differences were up to 0.39 log units (i.e., a factor of 2.5). Additional experiments suggested that this difference occurred because the sorption properties of the PA fibers used were influenced by the surrounding phase, e.g., through swelling of the polymer phase. Therefore, the SPME passive sampling method using PA fibers seems to be less reliable, whereas the silicone membrane equilibrator method was found to be a convenient technique for the determination of oil–water partitioning.  相似文献   

19.
P. Popp  A. Paschke 《Chromatographia》1997,46(7-8):419-424
Summary A new 80 μm Carboxen-polydimethylsiloxane (PDMS) fiber for solid phase microextraction (SPME) was tested for the enrichment of volatile organic compounds from water and air. Detection limits between 13 ng L−1 (CH2Cl2) and 0.1 ng L−1 (CHCl2Br and CHClBr2) for the combination: Carboxen-PDMS fiber and GC-ECD and between 35 ng L−1 and 45 ng L−1 (BTEX compounds) for the combination: Carboxen-PDMS and GC-FID using the headspace procedure were determined. Comparisons with the 100 μm PDMS fiber and further coatings show the advantages of the Carboxen-PDMS fiber with respect to extraction efficiency. Disadvantages of the new fiber compared with the 100 μm PDMS fiber are poorer repeatability and prolongation of equilibrium time. Distribution coefficients of the BTEX compounds between aqueous solution and SPME fiber coating were calculated and compared with the results of other researchers and with octanol-water partition coefficients.  相似文献   

20.
A solid-phase microextraction (SPME) procedure has been developed for the determination of 16 US Environmental Protection Agency promulgated polycyclic aromatic hydrocarbons (PAHs). Five kinds of SPME fibers were used and compared in this study. The extracted sample was analyzed by gas chromatography with flame ionization detection or mass spectrometry. Parameters affecting the sorption of analyte into the fibers, including sampling time, thickness of the fiber coating, and the effect of temperature, have been examined. Moreover, the feasibility of headspace SPME with different working temperatures was evaluated. The method was also applied to real samples. The 85-microm polyacrylate (PA) and 100-microm poly(dimethylsiloxane) (PDMS) fibers were shown to have the highest affinities for the selected PAHs. The PA fiber was more suitable than the PDMS fiber for the determination of low-ring PAHs while high sensitivity of high-ring PAHs was observed when a 100-microm PDMS fiber was used. The method showed good linearity between 0.1 and 100 ng/ml with regression coefficients ranging from 0.94 to 0.999. The reproducibility of the measurements between fibers was found to be very good. The precisions of PA and PDMS fibers were from 3 to 24% and from 3 to 14%, respectively. Headspace SPME is a valid alternative for the determination of two- to five-ring PAHs. A working temperature of 60 degrees C provides significant enhancement in sensitivity of two- to five-ring PAHs having low vapor pressures (>10(-6) mmHg at 25 degrees C) (1 mmHg = 133.3 Pa) and low Henry's constants (>10 atm ml/mol) (1 atm = 1.01 x 10(5) Pa).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号