首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
By virtue of their compactness, long-term stability, minimal reagent consumption and robustness, miniaturized sequential injection instruments are well suited for automation of assays onboard research ships. However, in order to reach the sensitivity and limit of detection required for open-ocean determinations of trace elements, it is necessary to preconcentrate the analyte prior its derivatization and subsequent detection by fluorescence. In this work, a novel method for the determination of dissolved zinc (Zn) at subnanomolar levels in seawater is described. The proposed method combines, for the first time, automated matrix removal, extraction of the target element, and fluorescence detection within a miniaturized flow manifold, based on the Lab-On-Valve (LOV) concept. The key feature of the microfluidic manipulation of the sample is flow programming, designed to pass sample through a mini-column where the target analyte and other complexable cations are retained, while the seawater matrix is washed out. Next, zinc is eluted and merged with a Zn selective fluorescent probe (FluoZin-3) at the confluence point of the LOV central channel using two high-precision stepper motor driven pumps that are operated in concert. Finally, the thus formed Zn complex is transported to the LOV flow cell for selective fluorescence measurement. This work describes the characterization and optimization of the method including Solid Phase Extraction using the Toyopearl AF-Chelate-650M resin, and detailed assay protocol controlled by a commercially available software and instrument. The proposed method features a LOD of 0.02 nM, high precision (<3% at 0.1 and 2 nM Zn levels), an assay cycle of 13 min and a reagent consumption of 150 μL FluoZin-3 per sample, which makes the method highly suitable for oceanographic shipboard analysis. The accuracy of the method has been validated through the analysis of seawater reference standards and comparison with ICP-MS determinations on seawater samples collected in the upper 1300 m of the subtropical south Indian Ocean. This work confirms that integration of sample pretreatment with optical detection in the LOV format offers a widely applicable approach to trace analysis of seawater.  相似文献   

2.
Zinc ion fluorescence sensing and the binding properties of 4-methyl-2,6-bis(((phenylmethyl)imino)methyl)phenol (HL) have been investigated. It displays high selectivity for Zn2+ and can be used as zinc ion-selective luminescent probe for biological application under physiological conditions. The increase in emission in the presence of Zn2+ is accounted for by the formation of hexanuclear complex [Zn6(L)2(OH)2(CH3COO)8] characterized by X-ray crystallography. An approximately 6-fold Zn2+-selective chelation-enhanced fluorescence response in HEPES buffer (pH 7.4) is attributed due to the strong coordination of Zn(II) that would impose rigidity and hence decrease the nonradiative decay of the excited state. By incubation of cultured living cells (B16F10 mouse melanoma and A375 human melanoma) with HL, intracellular Zn2+ concentration could be monitored.  相似文献   

3.
Grand M  Oliveira HM  Ruzicka J  Measures C 《The Analyst》2011,136(13):2747-2755
This paper introduces the preliminary design and optimization of a micro-Sequential Injection lab-on-valve system (μSI-LOV) with fluorescence detection for the direct determination of trace Zn(2+) in an unacidified seawater matrix. The method capitalizes on the sensitivity and selectivity of FluoZin-3, which was originally designed to measure zinc in living cells. The optimum reaction conditions, sources of blank signal and physical parameters of the μSIA-LOV are evaluated with the requirements of trace metal analysis in mind, namely high sensitivity and low background signals. A detailed investigation of the effect of sample and reagent sequencing on sensitivity is presented for the first time using μSIA-LOV. We find that the order of sequencing greatly influences peak shape and analytical sensitivity with the highest and smoothest peaks obtained when a large volume of sample (75 μL) is aspirated last in the sequence prior to flow reversal and detection. The optimized reaction conditions and reagent/sample sequencing protocol yield a detection limit of 0.3 nM Zn(2+), high precision (RSD < 2.5%), a linear quantification range up to 40 nM and an analytical cycle of ~1 min per sample. This work demonstrates that μSI-LOV is capable of attaining detection limits that are close to those needed for open ocean determinations of Zn(2+) without preconcentration or separation of the analyte from the seawater matrix. The low reagent consumption (50 μL per sample), full automation and minimal maintenance requirements of μSI-LOV make it well suited for shipboard analysis and, eventually, for development to meet the pressing need for trace element measurements in unattended locations.  相似文献   

4.
设计合成了荧光传感分子水杨醛-4-甲氧基苯甲酰腙(SAMB),通过IR、1HNMR和元素分析确证了其结构,利用紫外-可见吸收光谱和荧光光谱考察了其对不同阳离子的识别作用。结果表明,SAMB的荧光发射对锌离子表现出高选择性响应,且形成1∶1型配合物。乙醇中锌离子的加入导致SAMB的荧光增强328倍,而其他过渡金属离子只引起SAMB的荧光的略微增强。初步探讨了受体分子与锌离子的结合模式与荧光增强机理。  相似文献   

5.
Zn(2+) is a necessary cofactor for thousands of mammalian proteins. Research has suggested that transient fluxes of cellular Zn(2+) are also involved in processes such as apoptosis. Observations of Zn(2+) trafficking have been collected using Zn(2+) responsive fluorescent dyes. A commonly used Zn(2+) fluorophore is 6-methoxy-8-p-toluenesulfonamido-quinoline (TSQ). The chemical species responsible for TSQ's observed fluorescence in resting or activated cells have not been characterized. Parallel fluorescence microscopy and spectrofluorometry of LLC-PK(1) cells incubated with TSQ demonstrated punctate staining that concentrated around the nucleus and was characterized by an emission maximum near 470 nm. Addition of cell permeable Zn-pyrithione resulted in greatly increased, diffuse fluorescence that shifted the emission peak to 490 nm, indicative of the formation of Zn(TSQ)(2). TPEN (N,N,N'N'-tetrakis(-)[2-pyridylmethyl]-ethylenediamine), a cell permeant Zn(2+) chelator, largely quenched TSQ fluorescence returning the residual fluorescence to the 470 nm emission maximum. Gel filtration chromatography of cell supernatant from LLC-PK(1) cells treated with TSQ revealed that TSQ fluorescence (470 nm emission) eluted with the proteome fractions. Similarly, addition of TSQ to proteome prior to chromatography resulted in 470 nm fluorescence emission that was not observed in smaller molecular weight fractions. It is hypothesized that Zn-TSQ fluorescence, blue-shifted from the 490 nm emission maximum of Zn(TSQ)(2), results from ternary complex, TSQ-Zn-protein formation. As an example, Zn-carbonic anhydrase formed a ternary adduct with TSQ characterized by a fluorescence emission maximum of 470 nm and a dissociation constant of 1.55 × 10(-7) M. Quantification of TSQ-Zn-proteome fluorescence indicated that approximately 8% of cellular Zn(2+) was imaged by TSQ. These results were generalized to other cell types and model Zn-proteins.  相似文献   

6.
Ratiometric imaging is a technique to reduce artifacts by minimizing the influence of extraneous factors on the fluorescence of a sensor and is particularly useful for cellular imaging studies. Here we characterized the iminocoumarin fluorophore as a new scaffold for sensors for ratiometric imaging. The iminocoumarin 4 showed a high quantum yield in aqueous media on excitation in the visible wavelength region, while its coumarin analogue showed little fluorescence. We therefore developed a novel fluorescence probe, ZnIC, for ratiometric imaging of Zn2+, using iminocoumarin as a fluorophore and (ethylamino)dipicolylamine as a Zn2+ chelator. ZnIC exhibited almost the same fluorescence properties as 4, and the emission spectrum of this probe was red-shifted on addition of Zn2+ under physiological conditions. ZnIC is selective for Zn2+ over other biologically important metal ions, such as Ca2+ and Mg2+, and has high affinity for Zn2+. To confirm the suitability of ZnIC for biological applications, we employed it for the ratiometric detection of changes in intracellular Zn2+ in cultured cells and in rat hippocampal slices. The results indicate that iminocoumarin is a useful fluorophore for fluorescence microscopic imaging and that ZnIC should be useful for studies on the biological functions of Zn2+.  相似文献   

7.
We report a two-photon probe (SZn-Mito) for mitochondrial zinc ions ([Zn2+]m). This probe shows a 7-fold enhancement of two-photon-excited fluorescence in response to Zn2+ with a dissociation constant (Kd(TP)) of 3.1 ± 0.1 nM and pH insensitivity in the biologically relevant range, allowing the detection of [Zn2+]m in a rat hippocampal slice at a depth of 100?200 μm without interference from other metal ions through the use of two-photon microscopy.  相似文献   

8.
8-Hydroxyquinoline derivative 1 as a fluorescent chemosensor for Zn2+ was synthesized. Because Cd2+ is often found with Zn2+ in the environment and can form fluorescent complexes with chelating fluorophores, a potentially important property of chemosensors for Zn2+ is their selectivity for Zn2+ over Cd2+. The Zn2+ or Cd2+ complexes of 1 gave an emission band from the 1:1 complex, but the fluorescence intensity for Cd2+ was a half of that for Zn2+. Ligand 1 is suited for use as a fluorescent chemosensor for Zn2+.  相似文献   

9.
The development and cellular applications of novel fluorescent probes for Zn2+, ZnAF-1F, and ZnAF-2F are described. Fluorescein is used as a fluorophore of ZnAFs, because its excitation and emission wavelengths are in the visible range, which minimizes cell damage and autofluorescence by excitation light. N,N-Bis(2-pyridylmethyl)ethylenediamine, used as an acceptor for Zn2+, is attached directly to the benzoic acid moiety of fluorescein, resulting in very low quantum yields of 0.004 for ZnAF-1F and 0.006 for ZnAF-2F under physiological conditions (pH 7.4) due to the photoinduced electron-transfer mechanism. Upon the addition of Zn2+, the fluorescence intensity is quickly increased up to 69-fold for ZnAF-1F and 60-fold for ZnAF-2F. Apparent dissociation constants (K(d)) are in the nanomolar range, which affords sufficient sensitivity for biological applications. ZnAFs do not fluoresce in the presence of other biologically important cations such as Ca2+ and Mg2+, and are insensitive to change of pH. The complexes with Zn2+ of previously developed ZnAFs, ZnAF-1, and ZnAF-2 decrease in fluorescence intensity below pH 7.0 owing to protonation of the phenolic hydroxyl group of fluorescein, whose pKa value is 6.2. On the other hand, the Zn2+ complexes of ZnAF-1F and ZnAF-2F emit stable fluorescence around neutral and slightly acidic conditions because the pKa values are shifted to 4.9 by substitution of electron-withdrawing fluorine at the ortho position of the phenolic hydroxyl group. For application to living cells, the diacetyl derivative of ZnAF-2F, ZnAF-2F DA, was synthesized. ZnAF-2F DA can permeate through the cell membrane, and is hydrolyzed by esterase in the cytosol to yield ZnAF-2F, which is retained in the cells. Using ZnAF-2F DA, we could measure the changes of intracellular Zn2+ in cultured cells and hippocampal slices.  相似文献   

10.
A new rhodamine-derived Schiff base (RS) was synthesized and its sensing property to metal ions was investigated by UV/vis and fluorescence spectroscopies. Addition of Hg2+ ions to the aqueous solution of RS gave a visual color change as well as significantly fluorescent enhancement, while other ions including Pb2+, Cd2+, Cr3+, Zn2+, Cu2+, Fe2+, Co3+, Ni2+, Ca2+, Mg2+, K+ and Na+ ions did not induce any distinct color/spectral changes, which constituted a Hg2+-selective fluorescent OFF-ON chemosensor. The Hg2+-induced ring-opening of spirolactam of rhodamine in RS resulted in the dual chromo- and fluorogenic observation.  相似文献   

11.
Superior fluorescence imaging methods are needed for detailed studies on biological phenomena, and one approach that permits precise analyses is time-resolved fluorescence measurement, which offers a high signal-to-noise ratio. Herein, we describe a new fluorescence imaging system to visualize biomolecules within living biological samples by means of time-resolved, long-lived luminescence microscopy (TRLLM). In TRLLM, short-lived background fluorescence and scattered light are gated out, allowing the long-lived luminescence to be selectively imaged. Usual time-resolved fluorescence microscopy provides fluorescence images with nanosecond resolution and has been used to image interactions between proteins, protein phosphorylation, the local pH, the refractive index, ion or oxygen concentrations, etc. Luminescent lanthanide complexes (especially europium and terbium trivalent ions (Eu3+ and Tb3+)), in contrast, have long luminescence lifetimes on the order of milliseconds. We have designed and synthesized new luminescent Eu3+ complexes for TRLLM and also developed a new TRLLM system using a conventional fluorescence microscope with an image intensifier unit for gated signal acquisition and a xenon flash lamp as the excitation source. When the newly developed luminescent Eu3+ complexes were applied to living cells, clear fluorescence images were acquired with the TRLLM system, and short-lived fluorescence was completely excluded. By using Eu3+ and Tb3+ luminescent complexes in combination, time-resolved dual-color imaging was also possible. Furthermore, we monitored changes of intracellular ionic zinc (Zn2+) concentration by using a Zn2+-selective luminescent Eu3+ chemosensor, [Eu-7]. This new imaging technique should facilitate investigations of biological functions with fluorescence microscopy, complementing other fluorescence imaging methodologies.  相似文献   

12.
We have developed a series of fluorescent Zn(2+) sensor molecules with distinct affinities for Zn(2+), because biological Zn(2+) concentrations vary over a wide range from sub-nanomolar to millimolar. The new sensors have K(d) values in the range of 10(-8)-10(-4) M, compared with 2.7 nM for ZnAF-2. They do not fluoresce in the presence of other biologically important metal ions such as calcium or magnesium, and they can detect Zn(2+) within 100 ms. In cultured cells, the fluorescence intensity of ZnAF-2 was saturated at low Zn(2+) concentration, while that of ZnAF-3 (K(d) = 0.79 muM) was not saturated even at relatively high Zn(2+) concentrations. In hippocampal slices, we measured synaptic release of Zn(2+) in response to high-potassium-induced depolarization. ZnAF-2 showed similar levels of fluorescence increase in dentate gyrus (DG), CA3 and CA1, which were indistinguishable. However, ZnAF-3 showed a fluorescence increase only in DG. Thus, by using a combination of sensor molecules, it was demonstrated for the first time that a higher Zn(2+) concentration is released in DG than in CA3 or CA1 and that we can easily visualize Zn(2+) concentration over a wide range. We believe that the use of various combinations of ZnAF family members will offer unprecedented versatility for fluorescence-microscopic imaging of Zn(2+) in biological applications.  相似文献   

13.
An organoselenium-based NSe(3) type of tripodal system 2 as a Hg(2+)-selective fluorescence "turn-on" probe is described. The "turn-on" fluorescence behavior of this selenotripod 2 is significant because it depends on Hg-Se bond formation and acts as a reporting unit for this system. The system exhibits immediate response (15 s) with a subnanomolar detection limit (0.1 nM) for the Hg(2+) ion. It efficiently detects both aqueous and nonaqueous Hg(2+) at 2 nM concentration.  相似文献   

14.
A new fluorescent probe for Zn2+, namely, 8-hydroxy-5-N,N-dimethylaminosulfonylquinolin-2-ylmethyl-pendant cyclen (L8), was designed and synthesized (cyclen=1,4,7,10-tetraazacyclododecane). By potentiometric pH, 1H NMR, and UV spectroscopic titrations, the deprotonation constants pKa1-pKa6 of L(8)4 HCl were determined to be <2, <2, <2 (for amino groups of the cyclen and quinoline moieties), 7.19+/-0.05 (for 8-OH of the quinoline moiety), 10.10+/-0.05, and 11.49+/-0.05, respectively, at 25 degrees C with I=0.1 (NaNO3). The results of 1H NMR, potentiometric pH, and UV titrations, as well as single-crystal X-ray diffraction analysis, showed that L8 and Zn2+ form a 1:1 complex [Zn(H-1L8)], in which the 8-OH group of the quinoline ring of L8 is deprotonated and coordinates to Zn2+, in aqueous solution at neutral pH. On addition of one equivalent of Zn2+ and Cd2+, the fluorescence emission of L8 (5 microM) at 512 nm in aqueous solution at pH 7.4 [10 mM HEPES with I=0.1 (NaNO3)] and 25 degrees C increased by factors of 17 and 43, respectively. We found that the cyclen moiety has the unique property of quenching the fluorescence emission of the quinolinol moiety when not complexed with metal cations, but enhancing emission when complexed with Zn2+ or Cd2+. In addition, the Zn2+-L8 complex [Zn(H-1L8)] is much more thermodynamically and kinetically stable (Kd{Zn(H-1L8)}=[Zn2+]free[L8]free/[Zn(H-1L8)]=8 fM at pH 7.4) than the Zn2+ complexes of our previous Zn2+ fluorophores ([Zn(H-1L2)] and [Zn(L3)]). Furthermore, formation of [Zn(H-1L8)] is much faster than those of [Zn(H-1L2)] and [Zn(L3)]. The staining of early-stage apoptotic cells with L8 is also described.  相似文献   

15.
A simple,water-soluble,Fe3+-selective fluorescent probe,derived from rhodamine B,was synthesized and characterized.The probe exhibits a fluorescence response toward Fe3+ with acceptable sensitivity and selectivity and even facilitates visual or naked-eye detection of Fe3+.The experiment results show that the response of the probe to Fe3+ is pH-independent over a wide range of 4.0-10.0.In addition,fluorescence microscopic imaging experiments have proven that the probe is cell permeable and can be used for monitoring intracellular Fe3+ in living cells.  相似文献   

16.
A new 2,6-bis(5,6-dihydrobenzo[4,5]imidazo[1,2-c]quinazolin-6-yl)-4-methylphenol (1) serves as a highly selective and sensitive fluorescent probe for Zn(2+) in a HEPES buffer (50 mM, DMSO:water = 1:9 (v/v), pH = 7.2) at 25 °C. The increase in fluorescence in the presence of Zn(2+) is accounted for by the formation of dinuclear Zn(2+) complex [Zn(2)(C(35)H(25)N(6)O)(OH)(NO(3))(2)(H(2)O)] (2), characterized by X-ray crystallography. The fluorescence quantum yield of the chemosensor 1 is only 0.019, and it increases more than 12-fold (0.237) in the presence of 2 equiv of the zinc ion. Interestingly, the introduction of other metal ions causes the fluorescence intensity to be either unchanged or weakened. By incubation of cultured living cells (A375 and HT-29) with the chemosensor 1, intracellular Zn(2+) concentrations could be monitored through selective fluorescence chemosensing.  相似文献   

17.
Two methoxy-substituted TQEN (N,N,N',N'-tetrakis(2-quinolylmethyl)ethylenediamine) derivatives, T(MQ)EN (N,N,N',N'-tetrakis(6-methoxy-2-quinolylmethyl)ethylenediamine) and T(TMQ)EN (N,N,N',N'-tetrakis(5,6,7-trimethoxy-2-quinolylmethyl)ethylenediamine), have been prepared, and their fluorescence properties with respect to Zn2+ coordination were investigated. Introduction of a methoxy substituent at 6-position of the quinoline ring enhances the fluorescence intensity by 10-fold, and the three methoxy substituents in the 5,6,7-positions afford significant enhancement of the long-wavelength component of the fluorescence of zinc complex. The substituents did not alter the binding affinity of these compounds toward zinc ion significantly. T(MQ)EN was proved to be effective in detection of zinc ion in cells by fluorescent microscopy.  相似文献   

18.
Lee MH  Wu JS  Lee JW  Jung JH  Kim JS 《Organic letters》2007,9(13):2501-2504
A novel tren-based tripodal chemosensor 1 bearing a rhodamine and two tosyl groups was synthesized and its sensing behavior toward metal ions was investigated by UV/vis and fluorescence spectroscopies. Addition of a Hg2+ ion to a CH3CN solution of 1 gave a visual color change as well as significantly enhanced fluorescence, while other ions including Pb2+, Zn2+, Cu2+, Ca2+, Ba2+, Cd2+, Co2+, Mg2+, Ag+, Cs+, Li+, and Na+ induced no or much smaller color/spectral changes, which constituted a Hg2+-selective fluorescent chemosensor (OFF-ON).  相似文献   

19.
Three compounds structurally related to the fluorescent zinc sensor Zinpyr-1 (ZP1) have been synthesized and characterized. In each of these ZinAlkylPyr (ZAP) analogues, an alkyl group (methyl, benzyl) replaces one of the metal-binding picolyl moieties in ZP1. The methyl-for-picolyl substitutions in ZAP1 and ZAP2 have a negligible effect on the optical spectrum of the fluorophore but elevate the quantum yields (Phi = 0.82 (ZAP1), 0.74 (ZAP2)) to values near that of Zn2+-saturated ZP1 (Phi = 0.92). The benzyl-for-picolyl substitution in ZAP3 similarly enhances the quantum yield (Phi = 0.52) relative to that of metal-free ZP1 (Phi = 0.38). As previously observed for methylated ZP1 sensors, methylation of the 6-position of the pyridyl ring diminishes the emission by lowering both the molar extinction coefficient and the quantum yield. Although these new ZAP compounds cannot detect Zn2+ fluorimetrically at neutral pH, complexation of Zn2+ does occur, as evidenced by sizable changes in the optical spectra. The ZAP1-3 probes can detect Zn2+ fluorimetrically at pH 9, indicating that proton-induced background emission obscures any Zn2+-induced fluorescence at pH 7. The tertiary amine groups in ZAP1-3 are less basic than those in ZP1, which implies that the additional pyridine rings are responsible for the emissive response to Zn2+ at pH 7.0.  相似文献   

20.
Huang S  Clark RJ  Zhu L 《Organic letters》2007,9(24):4999-5002
Two new 1,2,3-triazolyl-containing N4-tetradentate ligands show nanomolar affinity for Zn2+ under physiological conditions. Furthermore, they are easily derivatizable to afford fluorescent probes suitable for sensitive Zn2+ detection. Structural characterizations in both solid and solution states suggest that N3 and N2 in the 1,2,3-triazolyl moiety coordinate with Zn2+ in A and B to afford five-membered and six-membered coordination rings, respectively. The probes show sensitive fluorescence enhancement and ratiometric responses to Zn2+.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号