首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 811 毫秒
1.
Nanocomposite polymer electrolyte thin films of polyvinyl alcohol (PVA)-orthophosphoric acid (H3PO4)-Al2O3 have been prepared by solution cast technique. Films are irradiated with 50 MeV Li3+ ions having four different fluences viz. 5?×?1010, 1?×?1011, 5?×?1011, and 1?×?1012 ions/cm2. The effect of irradiation on polymeric samples has been studied and characterized. X-ray diffraction spectra reveal that percent degree of crystallinity of samples decrease with ion fluences. Glass transition and melting temperatures have been also decreased as observed in differential scanning calorimetry. A possible complexation/interaction has been shown by Fourier transform infrared spectroscopy. Temperature-dependent ionic conductivity shows an Arrhenius behavior before and after glass transition temperature. It is observed that ionic conductivity increases with ion fluences and after a critical fluence, it starts to decrease. Maximum ionic conductivity of ~2.3?×?10?5 S/cm owing to minimum activation energy of ~0.012 eV has been observed for irradiated electrolyte sample at fluence of 5?×?1011 ions/cm2. The dielectric constant and dielectric loss also increase with ion fluences while they decrease with frequency. Transference number of ions shows that the samples are of purely ionic in nature before and after ion irradiation.  相似文献   

2.
Feroz A. Mir 《哲学杂志》2013,93(3):331-344
PrFe0.7Ni0.3O3 thin films (thickness ~ 200 nm) were prepared by pulsed laser ablation technique on LaAlO3 substrate. These films were irradiated with 200?MeV Ag15+ ions at various fluencies, ranging from 1 × 1011 to 1 × 1012 ions/cm2. These irradiated thin films were characterized by using X-ray diffraction, dc conductivity, dc magnetization and atomic force microscopy. These films exhibit orthorhombic structure and retain it even after irradiations. The crystallite size (110–137?nm), micro strain (1.48 × 10?2–1.75 × 10?2 line?2?m?4) and dislocation density (79.7 × 1014–53.2 × 1014 line/m2) vary with ion fluencies. An enhancement in resistivity at certain fluence and then a decrease in its value (0.22175–0.21813?Ω?cm) are seen. A drastic change in observed magnetism after ion irradiation is seen. With ion irradiation, an increase in surface roughness, due to the formation of hillocks and other factors, is observed. Destruction of magnetic domains after irradiation can also be visualized with magnetic force microscopy and is in close agreement with magnetization data. The impact on various physical properties in these thin films after irradiation indicates a distortion in the lattice structure and consequently on single-particle band width caused by stress-induced defects.  相似文献   

3.
A. K. Nath  A. Kumar 《Ionics》2014,20(12):1711-1721
Swift heavy ion (SHI) irradiation has been used as a tool to enhance the electrochemical properties of ionic liquid-based nanocomposite polymer electrolytes dispersed with dedoped polyaniline (PAni) nanorods; 100 MeV Si9+ ions with four different fluences of 5?×?1010, 1?×?1011, 5?×?1011, and 1?×?1012 ions cm?2 have been used as SHI. XRD results depict that with increasing ion fluence, crystallinity decreases due to chain scission up to fluence of 5?×?1011 ions cm?2, and at higher fluence, crystallinity increases due to cross-linking of polymer chains. Ionic conductivity, electrochemical stability, and dielectric properties are enhanced with increasing ion fluence attaining maximum value at the fluence of 5?×?1011 ions cm?2 and subsequently decrease. Optimum ionic conductivity of 1.5?×?10?2 S cm?1 and electrochemical stability up to 6.3 V have been obtained at the fluence of 5?×?1011 ions cm?2. Ac conductivity studies show that ion conduction takes place through hopping of ions from one coordination site to the other. On SHI irradiation, amorphicity of the polymer matrix increases resulting in increased segmental motion which facilitates ion hopping leading to an increase in ionic conductivity. Thermogravimetric analysis (TGA) measurements show that SHI-irradiated nanocomposite polymer electrolytes are thermally stable up to 240–260 °C.  相似文献   

4.
ABSTRACT

Polycarbonate (PC) and polyethylene terephthalate (PET) thermoplastic polymer films were irradiated by low energy ion beams such as 100 keV Hydrogen (H+) ions and 350 keV Nitrogen (N+) ions at varied fluence from 1?×?1013 ions/cm2 to 5?×?1014 ions/cm2. The depth profile concentration of ions was calculated using Stopping and Range of Ions in Matter (SRIM) software code. Fourier Transform Infrared (FTIR) technique shows decrement in the intensity of peaks and disappearance of peaks mainly related to carbonyl stretching at 1770?cm?1 and C–C stretching at 1500?cm?1. Scanning electron microscopy (SEM) of irradiated polymers showed the formation of pores. X-ray diffraction (XRD) analysis has showed decrease in the intensity indicating the decrease in crystallinity after irradiation. Mechanical studies revealed that the molecular weight and microhardness decrease with increase in ion fluence due to increase in chain scission. The contact angle increased with increase in ion fluence indicating the hydrophobic nature of polymer after irradiation. Antibiofilm activity test of irradiated films shows resistance to Salmonella typhi (S. typhi) pathogen responsible for typhoid. The study shows that Nitrogen ion induces more damage compared to Hydrogen ions and PC films get more modified than PET films.  相似文献   

5.
ZnO thin films, irradiated by 80 MeV Ni+ ions, were analysed with the help of different characterization techniques like X-ray diffraction, optical absorption, transmission, photoluminescence (PL), electrical resistivity, photosensitivity (PS) and thermally stimulated current (TSC) measurements. Crystallinity and absorption edge were hardly affected by irradiation. PL spectrum of pristine sample showed a broad peak at 517 nm, whereas irradiated film had two emissions at 517 and 590 nm. Intensity ratio between these two emissions (I517/I590) decreased with the fluence, and finally at a fluence of 3×1013 ions/cm2, the emission at 517 nm completely disappeared. Electrical resistivity of the sample irradiated with a fluence of 1×1013 ions/cm2 drastically increased. However, on increasing the fluence to 3×1013 ions/cm2, resistivity decreased, probably due the onset of hopping conduction through defects. PS also decreased due to irradiation. TSC measurements on pristine sample could reveal only one defect level at 0.6 eV, due to interstitia1 zinc (ZnI). But, irradiation at a fluence of 1×1012 ions/cm2, resulted in three different defect levels as per TSC studies. Interestingly, the sample irradiated at a fluence of 3×1013 ions/cm2 had only one defect level corresponding to a deep donor. The possible origin of these defect levels is also discussed in the paper.  相似文献   

6.
Makrofol-N polycarbonate was irradiated with carbon (70 MeV) and copper (120 MeV) ions to analyze the induced effects with respect to optical and structural properties. In the present investigation, the fluence for carbon and copper beams was kept in the range of 1×1011– 1×1013 ions/cm2 to study the swift heavy ion induced modifications. UV–VIS, FTIR and XRD techniques were utilized to study the induced changes. The analysis of UV–VIS absorption studies revealed that the optical energy gap was reduced by 17% on carbon irradiation, whereas the copper beam leads to a decrease of 52% at the highest fluence of 1×1013 ions/cm2. The band gap can be correlated to the number of carbon atoms, N, in a cluster with a modified Robertson's equation. In copper (120 MeV) ions irradiated polycarbonate, the number of carbon atoms in a cluster was increased from 63 to 269 with the increase of ion fluence from 0 to 1×1013 ions/cm2, whereas N is raised only up to 91 when the same polymer films were irradiated with carbon (70 MeV) ions under similar conditions. FTIR analysis showed a decrease in almost all characteristic absorption bands under irradiation. The formation of hydroxyl (? OH) and alkene (C?C) groups were observed in Makrofol-N at higher fluence on irradiation with both types of ions, while the formation alkyne end (R? C≡ CH) group was observed only after copper ions irradiation. The radii of the alkyne production of about 3.3 nm were deduced for copper (120 MeV) ions. XRD measurements show a decrease in intensity of the main peak and an increase of the average intermolecular spacing with the increase of ion fluence, which may be attributed to the structural degradation of Makrofol-N on swift ion irradiation.  相似文献   

7.
Vanadium dioxide thin films have been deposited on Corning glass substrates by a KrF laser ablation of V2O5 target at the laser fluence of 2 J?cm?2. The substrate temperature and the target-substrate distance were set to 500 °C and 4 cm, respectively. X-ray diffraction analysis showed that pure VO2 is only obtained at an oxygen pressure range of 4×10?3–2×10?2 mbar. A higher optical switching contrast was obtained for the VO2 films deposited at 4×10?3–10?2 mbar. The films properties were correlated to the plume-oxygen gas interaction monitored by fast imaging of the plume.  相似文献   

8.
ABSTRACT

ZnTe (Zinc Telluride) is a potential semiconducting material for many optoelectronic devices like solar cells and back contact material for CdTe-based solar cells. In the present study, ZnTe thin films were prepared by thermal evaporation technique and then irradiated with 120?MeV Si9+ ions at different fluences. These films are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and UV–Visible spectroscopy techniques. XRD study confirms increased crystallinity and grain growth for post-irradiated ZnTe thin films for fluences, up to 1?×?1011 ions cm?2. However, the grain size and crystallinity decreased for higher fluence-exposed samples. SEM images confirm the observed structural properties. Modification of the surface morphology of the film due to the ion irradiation with different fluences is studied. Optical band gap of film is decreased from 2.31?eV (pristine) to 2.17?eV after irradiation of Si9+ ions.  相似文献   

9.
Polyethylene terephthalate (PET) films of 50?μm thickness were exposed to swift-heavy 50?MeV copper and 84?MeV oxygen ions, with fluence varying from 1?×?1011 to 1?×?1013 ions cm?2. Differential scanning calorimetry (DSC), X-ray diffraction (XRD) and Fourier-transform infrared (FTIR) and UV-visible spectroscopic techniques were used to characterize the irradiated samples. The XRD and DSC analysis indicated the loss of crystallinity during/after the irradiation. The FTIR spectra revealed the formation of alkyne end groups, C═C groups and structural deformation with increase of ion fluence. Considerable reduction in the value of the optical bandgap was inferred from the study of the UV-visible absorption curves.  相似文献   

10.
The mixing of Au in Si induced by secondary and high-order recoil implantation was investigated using 350 keV Ar+ and 350 keV Kr+ ions to fluences from 1?×?1016 to 3?×?1016 ions/cm2 at room temperature. The thickness of the Au layer evaporated on Si substrate was ~2400 Å.The ranges of the Ar and Kr ions were chosen to be lower than the thickness of the Au layer in order to avoid the ballistic mixing produced by the primary knock-on atoms. Rutherford backscattering spectrometry (RBS) experiments were carried out to study the effects induced by Ar and Kr irradiation at the interface of Au–Si system. We observed that in the case of the irradiation with Ar+ ions, a broadening of the Au–Si interface occurred only at the fluence of 3?×?1016 Ar+/cm2 and it is attributed to the surface roughening induced by ion bombardment. In contrast, the RBS analysis of a sample irradiated with 2?×?1016 Kr+/cm2 clearly showed, in addition to the broadening effect, the formation of a mixed zone of Au and Si atoms at the interface. The mixing of Au in Si atoms can be explained by the secondary and high-order recoil implantation followed by subsequent collision cascades.  相似文献   

11.
The present work is devoted to investigation of optical absorption in pure and neodymium-doped YAlO3 (YAP) single crystals in the spectral range 0.2–1.1 μm induced by the influence of 12C ions irradiation with energy 4.50 MeV/u (MeV per nucleon) and a fluence 2 × 109 cm?2 or of 235U ion irradiation with energy 9.35 MeV/u and a fluence 5 × 1011 cm?2. The induced absorption in the case of 12C ions irradiation is caused by recharging of point growth defects and impurities under the radiation influence. After irradiation by 235U ions with fluence 5 × 1011 cm?2 the strong absorption rise is probably caused by contribution of the lattice destruction as a result of heavy ion bombardment.  相似文献   

12.
K.Y. Yu  C. Sun  Y. Chen  Y. Liu  H. Wang  M.A. Kirk 《哲学杂志》2013,93(26):3547-3562
Monolithic Ag and Ni films and Ag/Ni multilayers with individual layer thickness of 5 and 50?nm were subjected to in situ Kr ion irradiation at room temperature to 1 displacement-per-atom (a fluence of 2?×?1014?ions/cm2). Monolithic Ag has high density of small loops (4?nm in diameter), whereas Ni has fewer but much greater loops (exceeding 20?nm). In comparison, dislocation loops, ~4?nm in diameter, were the major defects in the irradiated Ag/Ni 50?nm film, while the loops were barely observed in the Ag/Ni 5?nm film. At 0.2?dpa (0.4?×?1014?ions/cm), defect density in both monolithic Ag and Ni saturated at 1.6 and 0.2?×?1023/m3, compared with 0.8?×?1023/m3 in Ag/Ni 50?nm multilayer at a saturation fluence of ~1?dpa (2?×?1014?ions/cm2). Direct observations of frequent loop absorption by layer interfaces suggest that these interfaces are efficient defect sinks. Ag/Ni 5?nm multilayer showed a superior morphological stability against radiation compared to Ag/Ni 50?nm film.  相似文献   

13.
The self-standing films of polymethyl methacrylate (PMMA) were irradiated under vacuum with 50?MeV lithium (Li3+) and 80?MeV carbon (C5+) ions to the fluences of 3?×?1014, 1?×?1015, 1?×?1016 and 1?×?1017 ions µm?2. The pristine and irradiated samples of PMMA films were studied by using ultraviolet–visible (UV–Vis) spectrophotometry, Fourier transform infrared, X-ray diffractrometer and atomic force microscopy. With increasing ion fluence of swift heavy ion (SHI), PMMA suffers degradation, UV–Vis spectra show a shift in the absorption band from the UV towards visible, attributing the formation of the modified system of bonds. Eg and Ea decrease with increasing ion fluence. The size of crystallite and crystallinity percentage decreases with increasing ion fluence. With SHI irradiation, the intensity of IR bands and characteristic bands of different functional groups are found to shift drastically. The change in (Eg) and (N) in carbon cluster is calculated. Shifting of the absorption band from the UV towards visible along with optical activity and as a result of irradiation, some defects are created in the polymer causing the formation of conjugated bonds and carbon clusters in the polymer, which in turn lead to the modification in optical properties that could be useful in the fabrication of optoelectronic devices, gas sensing, electromagnetic shielding and drug delivery.  相似文献   

14.
The free volume of the microvoids in the polyimide samples, irradiated with 6 MeV electrons, was measured by the positron annihilation technique. The free volume initially decreased the virgin value from ~13.70 to ~10.98 Å3 and then increased to ~18.11 Å3 with increasing the electron fluence, over the range of 5?×?1014 – 5?×?1015 e/cm2. The evolution of gaseous species from the polyimide during electron irradiation was confirmed by the residual gas analysis technique. The polyimide samples irradiated with 6 MeV electrons in AgNO3 solution were studied with the Rutherford back scattering technique. The diffusion of silver in these polyimide samples was observed for fluences >2?×?1015 e/cm2, at which microvoids of size ≥3 Å are produced. Silver atoms did not diffuse in the polyimide samples, which were first irradiated with electrons and then immersed in AgNO3 solution. These results indicate that during electron irradiation, the microvoids with size ≥3 Å were retained in the surface region through which silver atoms of size ~2.88 Å could diffuse into the polyimide. The average depth of diffusion of silver atoms in the polyimide was ~2.5 μm.  相似文献   

15.
A thin film of dilute Fe (0.008)-doped Sb0.95Se0.05 alloy was grown on silicon substrate using the thermal evaporation technique. This film was irradiated with swift heavy ions (SHIs) Ag+15 having 200?MeV energy at ion fluences of 1?×?1012 and 5?×?1012 ions per cm2, respectively. The thickness of the thin film was ~500?nm. We study the effect of irradiation on structural, electrical, surface morphology and magnetic properties of this film using grazing angle XRD (GAXRD), DC resistivity, atomic force microscopy (AFM) and magnetic force microscopy (MFM), respectively. GAXRD suggests that no significant change is observed in this system due to SHI irradiation. The average crystallite size increases with fluence, whereas the AFM image shows the rms roughness decreases due to irradiation with respect to the un-irradiated thin film. The MFM image shows that the magnetic interaction in irradiated film decreases due to the irradiation effect. Although the un-irradiated sample shows metal to semiconducting transition, but after irradiation with fluence of 5?×?1012 ions per cm2, the sharpness of the metal to semiconducting phase transition is observed to increase dramatically at ~300?K. This characteristic of the thin film makes it a promising candidate for an electrical switching device after irradiation.  相似文献   

16.
The effects of 200 MeV Au ions irradiation on the structural and magnetic properties of Ni–Mn–Sn ferromagnetic shape memory alloy (FSMA) thin films have been systematically investigated. In order to understand the role of initial microstructure and phase of the film with respect to high energy irradiation, the two types of Ni–Mn–Sn FSMA films having different phases at room temperature were irradiated, one in martensite phase (Ni58.9Mn28.0Sn13.1) and other in austenite phase (Ni50Mn35.6Sn14.4). Transmission electron microscope (TEM) and scanning electron microscope (SEM) images along with the diffraction patterns of X-rays and electrons confirm that martensite phase transforms to austenite phase at a fluence of 6×1012 ions/cm2 and a complete amorphization occurs at a fluence of 3×1013 ions/cm2, whereas ion irradiation has a minimal effect on the austenitic structure (Ni50Mn35.6Sn14.4). Thermo-magnetic measurements also support the above mentioned behaviour of Ni–Mn–Sn FSMA films with increasing fluence of 200 MeV Au ions. The results are explained on the basis of thermal spike model considering the core and halo regions of ion tracks in FSMA materials.  相似文献   

17.
ABSTRACT

Thermally grown SiO2 thin films on a silicon substrate implanted with 100?keV silicon negative ions with fluences varying from 1?×?1015 to 2?×?1017 ions cm?2 have been investigated using Electron spin resonance, Fourier transforms infrared and Photoluminescence techniques. ESR studies revealed the presence of non-bridging oxygen hole centers, E′-centers and Pb-centers at g-values 2.0087, 2.0052 and 2.0010, respectively. These vacancy defects were found to increase with respect to ion fluence. FTIR spectra showed rocking vibration mode, stretching mode, bending vibration mode, and asymmetrical stretching absorption bands at 460, 614, 800 and 1080?cm?1, respectively. The concentrations of Si–O and Si–Si bonds estimated from the absorption spectra were found to vary between 11.95?×?1021 cm?3 and 5.20?×?1021 cm?3 and between 5.90?×?1021 cm?3 and 3.90?×?1021 cm?3, respectively with an increase in the ion fluence. PL studies revealed the presence of vacancies related to non-bridging oxygen hole centers, which caused the light emission at a wavelength of 720?nm.  相似文献   

18.
Response of Zr–2.5 wt.% Nb alloy pressure tube, used in PHWR nuclear reactors, to 315 keV Ar9+ ion irradiation at room temperature was investigated in the fluence range of 3.1?×?1015–4.17?×?1016 Ar9+?cm?2. Changes in microstructural parameters, viz., the size of coherently scattering domains, microstrain and dislocation density, upon irradiation were ascertained through grazing incidence X-ray diffraction. In general, a decrease in domain size was observed with fluence with a corresponding increase in microstrain and dislocation density. Residual stress measurement showed the development of compressive stresses in place of tensile after irradiation. Transmission electron microscopy showed the formation of dislocation loops of ?a?-type and ?c?-type during irradiation. The hardness of irradiated samples, probed through nanoindentation technique, was found to be higher in comparison with unirradiated samples. The above findings have been rationalised on the basis of the defects generated during the Ar9+ ion irradiation.  相似文献   

19.
Gallium Selenide (GaSe) thin films were grown by the electrochemical deposition (ECD) technique on Indium tin oxide (ITO) and p-Si (100) substrates. The Electron paramagnetic resonance (EPR) spectrum of GaSe thin films’ growth on ITO was recorded at room temperature. According to EPR results, the g value of an EPR signal obtained for GaSe deposited on ITO is 2.0012?±?0.0005. In/GaSe/p-Si heterojunction was irradiated with high-energy (6?MeV) and low-dose (1.53?×?1010?e??cm?2) electrons. The ideality factor of the In/GaSe/p-Si device was calculated as 1.24 and barrier height was determined as 0.82?eV from I–V measurements before irradiation. Acceptor concentration, built-in potential and barrier height of the In/GaSe/p-Si device were also obtained as 0.72?×?1014?cm?3, 0.65?eV and 0.97?eV from C–V measurements, respectively. After irradiation, the ideality factor n and barrier height Φb values of the In/GaSe/p-Si device were calculated as 1.55 and 0.781?eV, respectively. Acceptor concentration, the built-in potential and barrier height values of the In/GaSe/p-Si device have also shown a decrease after 6?MeV electron irradiation. This change in heterojunction device parameters shows that current transport does not obey thermionic emission, and thus tunneling could be active due to the defects formed by irradiation at the In–GaSe interface.  相似文献   

20.
Polycarbonate (Makrofol‐N) thin films were irradiated with protons (3 MeV) under vacuum at room temperature with the fluence ranging from 1×1014 to 1×1015 protons cm?2. The change in surface morphology, optical properties, degradation of the functional groups, and crystallinity of the proton‐irradiated polymers were investigated with atomic force microscopy (AFM), UV‐VIS, and Fourier‐transform infrared (FTIR) spectroscopy, and X‐ray diffraction (XRD) techniques, respectively. AFM shows that the root mean square (RMS) roughness of the irradiated polycarbonate surface increases with the increment of ion fluence. The UV‐VIS analysis revealed that in Makrofol‐N the optical band gap decreased by 30% at highest fluence of 1×1015 protons cm?2. The band gap can be correlated to the number of carbon atoms, M, in a cluster with a modified Robertson's equation. The cluster size in the proton‐irradiated Makrofol‐N increased from 112 to 129 atoms with the increase of fluence from 1×1014 to 1×1015 protons cm?2. FTIR spectra of proton (3 MeV) irradiated Makrofol‐N showed a strong decrease of almost all absorption bands at about 1× 1014 protons cm?2. However, beyond a higher critical dose an increase in intensity of almost all characteristic bands was noticed. The appearance of a new peak at 3,500 cm?1 (‐OH groups) was observed at the higher fluences in the FTIR spectra of proton‐irradiated polycarbonate. XRD measurements showed an increase of full width at half maximum (FWHM) and the average intermolecular spacing of the main peak, which may be due to the increase of chain scission and the introduction of ‐OH groups in the proton irradiated polycarbonate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号