首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
A novel solid phase extraction technique for the speciation of trace dissolved Fe(II) and Fe(III) in environmental water samples was developed by coupling micro-column packed with N-benzoyl-N-phenylhydroxylamine (BPHA) loaded on microcrystalline naphthalene to electrothermal vaporization inductively coupled plasma-optical emission spectrometry (ETV-ICP-OES). Various influencing factors on the separation and preconcentration of Fe(II) and Fe(III), such as the acidity of the aqueous solution, sample flow rate and volume, have been investigated systematically, and the optimized operation conditions were established. At pH 3.0 Fe(III) could be selectively retained by micro-column (20 mm × 1.4 mm, i.d.) packed with BPHA immobilized on microcrystalline naphthalene, and Fe(II) passed through the micro-column. Both Fe(II) and Fe(III) could be adsorbed by the micro-column at pH 6.5. Thus, the total Fe could be determined without the need for preoxidation of Fe(II) to Fe(III). The retained Fe(III) or the Fe(II) and Fe(III) was subsequently eluted by 0.1 ml of 1 mol l−1 HCl. The adsorption capacity of the solid phase adsorption material was found to be 45.0 mg g−1 for Fe(III) at pH 3.0 and 65.3 mg g−1 for Fe(II) at pH 6.5, respectively. The detection limit (3σ) of 0.053 μg l−1 was obtained with a practical enrichment factor of 156 at a sample volume of 17 ml. The relative standard deviations of 4.2% and 4.6% (CFe(III) = CFe(II) = 10 μg l−1, n = 7) for Fe(III) and total iron were found, respectively. The method was successfully applied to the determination of trace Fe(II) and Fe(III) in environmental water samples (East Lake water, local tap water and mineral water). In order to validate the method, the developed method was applied to the determination of total iron in certified materials of NIES NO.10-b rice flour and GBW07605 tea leaves, and the results obtained were in good agreement with the certified values.  相似文献   

2.
A method for rapid speciation analysis of iron was developed by on-line coupling of short column capillary electrophoresis and inductively coupled plasma mass spectrometry. The collision cell technique was used to eliminate argon-based polyatomic interferences and a Micromist nebulizer was employed to increase the nebulization efficiency. Rapid speciation analysis of Fe(II) and Fe(III) was achieved within 1 min by short column capillary electrophoresis in a 14 cm x 50 microm id capillary at 28 kV voltage with a mixture of 15 mmol/L tris(hydroxymethyl)aminomethane + 1 mmol/L 1,10-phenanthroline + 1 mmol/L EDTA (pH 8.6) as running electrolyte. The precisions (RSD, n = 5) of migration time and peak area for Fe(II) and Fe(III) were in the range of 1.0 - 2.6 and 1.9 - 3.9%, respectively. The limits of detection (3sigma) of Fe(II) and Fe(III) were 10.0 and 8.3 microg/L, respectively.  相似文献   

3.
Kara D  Alkan M 《Talanta》2001,55(2):415-423
The synthesis and analytical applications of N,N'-bis(2-hydroxy-5-bromo-benzyl)1,2 diaminopropane (HBDAP) are described. This compound reacts with Fe(III) in the range of pH 3-6 to produce a red complex (2:3 mol ratio of Fe(III)/HBDAP) soluble in chloroform. The investigation included a study of the characteristics that are essential for solvent extraction and for spectrophotometric determination and speciation of iron. A highly sensitive, selective and rapid spectrophotometric method is described for the determination of trace amounts of iron(III) by HBDAP. The complex obeys Beer's law from 0.056 to 1.68 mg l(-1) with an optimum range. The detection limit (taken as three times the standard deviation of the reagent blank) is approximately 1.23x10(-7) M Fe(III) and the limit of quantitation (taken as ten times the standard deviation of the reagent blank) is about 4.11x10(-7) M Fe(III). A single extraction gave a good separation of iron(III) from iron(II). Good separation of Fe(III) from Ni(II), Fe(II), Co(II), Cd(II), Mn(II), Zn(II), Pb(II) was also achieved at pH 3-5.  相似文献   

4.
An analytical method was developed for antimony speciation and antimony(III) preconcentration in water samples. The method is based on the selective retention of Sb(III) by modified Saccharomyces cerevisiae in the presence of Sb(V). Heat, caustic and solvent pretreatments of the biomass were investigated to improve the kinetics and thermodynamics of Sb(III) uptake process at room temperature. Heating for 30 min at 80 degrees C was defined as the optimal treatment. Antimony accumulation by the cells was independent of pH (5-10) and ionic strength (0.01-0.1 mol L(-1)). 140 mg of yeast and 2h of contact were necessary to ensure quantitative sequestration of Sb(III) up to 750 microg L(-1). In these conditions, Sb(V) was not retained. Sb(V) was quantified in sorption supernatant by inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma optical emission spectrometry (ICP-OES). Sb(III) was determined after elution with 40 mmol L(-1) thioglycolic acid at pH 10. A preconcentration factor close to nine was achieved for Sb(III) when 100mL of sample was processed. After preconcentration, the detection limits for Sb(III) and Sb(V) were 2 and 5 ng L(-1), respectively, using ICP-MS, 7 and 0.9 microg L(-1) using ICP-OES. The proposed method was successfully applied to the determination of Sb(III) and Sb(V) in spiked river and mineral water samples. The relative standard deviations (n=3) were in the 2-5% range at the tenth microg L(-1) level and less than 10% at the lowest Sb(III) and Sb(V) tested concentration (0.1 microg L(-1)). Corrected recoveries were in all cases close to 100%.  相似文献   

5.
A pneumatic flow injection-tandem spectrometer system, without a delivery pump was used for the speciation of iron. In this system, the suction force of a pneumatic nebulizer of a flame absorption spectrometer was used for solution delivery through the manifold. The Fe(III) and total Fe concentrations were determined using thiocyanate ion in a UV-Vis spectrometer and a FAAS, respectively. The Fe(II) was determined by the difference. The calibration curves were linear up to 18 microg mL(-1) and 25 microg mL(-1) with detection limits of 0.09 microg mL(-1) and 0.07 microg mL(-1) for Fe(III) and Fe(II), respectively. The mid-range precision and accuracy were <2.5% and +/-3% for the two species, respectively, at a sampling rate of 120 h(-1). This system was applied for the determination of Fe(III) and Fe(II) in industrial water, natural water and spiked samples.  相似文献   

6.
The use of 1-phenyl-3-methyl-4-benzoylpyrazolone (PMBP) as extractant for separation of Fe(III) and Fe(II) and low-temperature vaporization of the Fe(III)–PMBP chelate into ICP-AES for their speciation analysis was investigated. The factors affecting the formation of Fe(PMBP)3 chelate and its vaporization behavior were investigated in detail. PMBP was used not only as the extractant for the separation of Fe(III) and Fe(II) but also as the chemical modifier for the low-temperature ETV-ICP-AES determination of iron. Under the optimized conditions, the detection limit for iron(III) and iron(II) are both 3.2?ng/mL, with relative standard deviations of 3.9 and 4.5%, respectively. The proposed method was applied to the determination of trace iron in biological standard reference materials and the species in East Lake water samples, and the results obtained were satisfactory.  相似文献   

7.
Hoshino H  Yotsuyanagi T 《Talanta》1984,31(7):525-530
The ion-pair extraction equilibria of the iron(II) and iron(III) chelates of 4-(2-pyridylazo)resorcinol (PAR, H(2)L) are described. The anionic chelates were extracted into chloroform with benzyldimethyltetradecylammonium chloride (QC1) as counter-ion. The extraction constants were estimated to be K(ex1)(Fe(II)) = [Q{Fe(II)(HL)L}](0)/[Q(+)][{Fe(II)(HL)L}(-)] = 10(8.59 +/- 0.11), K(ex2)(Fe(II)) = [Q(2){Fe(II)L(2)}](o)/ [Q(+)](2)[{Fe(II)L(2)}(2-)] = 10(12.17 +/- 0.10) and K(ex1)(Fe(III)) = [Q{Fe((III))L(2)}](o)/(Q(+)][{Fe(III)L(2)}(-)] = 10(6.78 +/- 0.15) at I = 0.10 and 20 degrees , where [ ](o) is concentration in the chloroform phase. Aggregation of Q{Fe(III)L(2)} in chloroform was observed and the dimerization constant (K(d) = [Q(2){Fe(III)L(2)}(2)](o)/[Q{Fe(III)L(2)}](o)(2)) was evaluated as log K(d) = 4.3 +/- 0.3 at 20 degrees . The neutral chelates of {Fe(II)(HL)(2)} and {Fe(III)(HL)L}, and the ion-pair of the cationic chelate, {Fe(III)(HL)(2)}ClO(4), were also extracted into chloroform or nitrobenzene. The relationship between the forms and extraction properties of the iron(II) and iron(III) PAR chelates are discussed in connection with those of the nickel(II) and cobalt(III) complexes. Correlation between the extraction equilibrium data and the elution behaviour of some PAR chelates in ion-pair reversed-phase partition chromatography is also discussed.  相似文献   

8.
Jiankun Duan 《Talanta》2009,79(3):734-738
A flow injection online speciation procedure by using micro-column packed with Cu(II) loaded nanometer-sized Al2O3 coupled to inductively coupled plasma mass spectrometry (ICP-MS) for the separation and determination of selenomethionine (SeMet) and selenocystine (SeCys2) has been developed. The main factors affecting the separation and preconcentration of SeMet and SeCys2 including pH value, sample flow rate, eluent concentration, eluent volume and flow rate, and interfering ions have been investigated. It was found that SeCys2 could be selectively retained by micro-column packed with Cu(II) loaded nanometer-sized Al2O3 at pH 4.0, and the retained SeCys2 could be eluted by 1.0 mol L−1 HNO3, while SeMet was not retained and passed through the micro-column directly at this pH. Both SeMet and SeCys2 could be quantitatively adsorbed by the micro-column at pH 9.0, and the retained SeMet and SeCys2 could be easily eluted with 1.0 mol L−1 HNO3. The content of SeMet was obtained by subtracting the SeCys2 from the total content of seleno amino acids. With the enrichment factor of 7.8 and 7.7, the limits of detection (LODs) for SeMet and SeCys2 were found to be 24 pg Se mL−1 and 21 pg Se mL−1, respectively. The relative standard deviations (RSDs) for SeCys2 and SeMet with seven replicate determinations of 1.0 ng mL−1 SeMet and SeCys2, were 2.1% and 1.6%, respectively, the sampling frequency of 8 h−1 was obtained. The proposed method was applied to the speciation of SeMet and SeCys2 in selenized yeast, human urine and serum with satisfactory results.  相似文献   

9.
Ma ZL  Wang YP  Wang CX  Miao FZ  Ma WX 《Talanta》1997,44(5):743-748
The separation and determination of Co(III), Ni(II), V(V) and Fe(III) chelates with 2-(2-benzothiazolylazo)-5-(3-sulfopropyl)aminophenol (BTASPAP) by reversed-phase ion-pair HPLC was investigated. In the presence of the oxidant potassium iodate, BTASPAP reacts with Co(III), Ni(II), V(V) and Fe(III) to form stable, negatively charged, water-soluble chelates. The chelates were separated on a C(18) siloxane bonded phase and eluted within 7 min with acetonitrile-acetate-water (36:1:63 v/v) containing 0.2 mol 1(-1) acetic acid-sodium acetate buffer (pH 3.0) and 1.0 mmol 1(-1) tetrabutylammonium bromide. The detection limits of Co(III), Ni(II), V(V) and Fe(III) at 565 nm are 0.3, 0.8, 0.3 and 1.0 ng (signal-to-noise ratio = 2), respectively. The method was applied to the determination of Co, Ni, V and Fe in four samples of standard alloys.  相似文献   

10.
A novel absorbent was prepared by dimercaptosuccinic acid chemically modifying mesoporous titanium dioxide and was employed as the micro-column packing material for simultaneous separation/preconcentration of inorganic arsenic and antimony species. It was found that both trivalent and pentavalent of inorganic As and Sb species could be adsorbed quantitatively on dimercaptosuccinic acid modified TiO2 within a pH range of 4–7, and only As(III) and Sb(III) could be quantitatively retained on the micro-column within a pH range of 10–11 while As(V) and Sb(V) were passed through the micro-column without the retention. Based on this fact, a new method of flow injection on-line micro-column separation/preconcentration coupled to inductively coupled plasma optical emission spectrometry was developed for simultaneous speciation of trace inorganic arsenic and antimony in natural waters. Under the optimized conditions, an enrichment factor of 10 and sampling frequency of 10 h− 1 were obtained with on-line mode. The detection limits of As(III), As(V), Sb(III), and Sb(V) are 0.53, 0.49, 0.77 and 0.71 ng mL− 1 for on-line mode and as low as 0.11, 0.10, 0.15 and 0.13 ng mL− 1 for off-line mode due to its higher enrichment factor (50), respectively. The relative standard deviations of two modes are less than 6.7% (C = 20 ng mL− 1, n = 7). The concentration ratio of lower oxidation states/higher oxidation states changing from 1:10 to 10:1 has no obvious effect on the recoveries of As(III) and Sb(III). In order to validate the developed method, two certified reference materials of GSBZ5004-88 and GBW(E)080545 water sample were analyzed and the determined values are in good agreement with the certified values. The proposed method was successfully applied to the simultaneous speciation of inorganic arsenic and antimony in natural waters.  相似文献   

11.
Preconcentration, speciation and separation with solvent extraction of Fe(III) from samples of different origin, using methyl isobutyl ketone (MIBK) as a solvent and the sodium salt of 2-carboethoxy-1,3-indandione (CEIDNa) as a complexing agent for Fe(III), were studied. CEIDNa reacts with Fe(III) in the pH range 1.5–3.5 to produce a red colored complex of Fe(III)–CEIDNa (1:3 molar ratio) soluble in MIBK. The investigation includes a study of the characteristics that are essential for solvent extraction, spectrophotometric and flame atomic absorption spectrometric determination (AAS) of iron. A highly sensitive, selective and rapid spectrometric method is described for the trace analysis of iron(III) by CEIDNa. The complex formed obeys Beer's law from 0.06 to 1.8 mg l−1 with an optimum range. A single step extraction was efficiently used with a distribution ratio (D)=103.6. The extracted red colored (1:3) Fe–CEIDNa was measured spectrophotometrically at 500 nm with a molar absorptivity of 1.2×104 l mol−1 cm−1. In addition, the organic phase was directly aspirated to the flame for AAS determination and the signals related to Fe(III) concentration were recorded at 243.3 nm. The complexation of iron(III) with CEIDNa allows the separation of the analyte from alkali, alkaline earth and other elements, which are not complexed. The proposed preconcentration procedure was applied successfully to the determination of trace Fe(III) in soil, milk and natural water samples.  相似文献   

12.
A simple and rapid method is developed for the simultaneous determination of Cr(VI) and Cr(III) based on the formation of their different complexes with ammonium pyrrolidine-dithiocarbamate (APDC). Separation is performed using reversed-phase high-performance liquid chromatography coupled with UV detection. The conditions for complex formation and speciation are determined, such as solution pH, amount of APDC, temperature, and type of mobile phase. In order to substantially reduce the analysis time, the separation is carried out without extraction of chromium-APDC complexes from the mother liquor. Under the optimum analysis conditions, the chromatograms obtained show good peak separation, and the absolute detection limits (3s) are 2.2 microg/L for Cr(VI) and 4.5 microg/L for Cr(III). The calibration curves are linear from 3 to 5000 microg/L for Cr(VI) and 5 to 3000 microg/L for Cr(III). The relative standard deviations of peak areas in five measurements using a sample solution of 200 microg/L are less than 2% for Cr(VI) and 4% for Cr(III), indicating good reproducibility for this analytical method. Furthermore, simultaneous determination of Cr(VI) and Cr(III) is successful with the application of the proposed procedure in the synthetic wastewaters containing common heavy metal ions: Fe(III), Pb(II), Cd(II), Cu(II), and Zn(II).  相似文献   

13.
Speciation of arsenic in environmental samples gains increasingly importance, as the toxic effects of arsenic are related to its oxidation state. A method was developed for the determination of trace amounts of arsenic (III) and total arsenic by flow injection hydride generation coupled with an in-house made non-dispersive AAS device. The total arsenic is determined after prereduction of arsenic (V) to arsenic (III) with L-cysteine in a low concentration of hydrochloric, acetic or nitric acid. The conditions for the prereduction, hydride generation and atomization were systematically investigated. A quartz tube temperature of 800 degrees C was found to be optimum in view of peak shape and baseline stability. Pb(II), Ni(II), Fe(III), Cu(II), Ag(I), Al(III), Ga(II), Se(IV), Bi(III) were checked for interfering with the 2 microg/L As(V) signal. A serious signal depression was only observed for Se(IV) and Bi(III) at a 150-fold excess. With the above system, arsenic was determined at a sampling frequency of about 1/min with a detection limit (3sigma) of 0.01 microg/L using a 0.5 mL sample. The reagent blank was 0.001+/-0.0003 absorbance units and the standard deviation of 10 measurements of the 2 microg/l As signal was found to be 1.2%. Results obtained for standard reference materials and water samples are in good agreement with the certified values and those obtained by ICP-MS  相似文献   

14.
Cloud point extraction (CPE) was applied as a preconcentration step for HPLC speciation of chromium in aqueous solutions. Simultaneous preconcentration of Cr(III) and Cr(VI) in aqueous solutions was achieved by CPE with diethyldithiocarbamate (DDTC) as the chelating agent and Triton X-114 as the extractant. Baseline separation of the DDTC chelates of Cr(III) and Cr(VI) was realized on a RP-C18 column with the use of a mixture of methanol-water-acetonitrile (65:21:14, v/v) buffered with 0.05 M NaAc-HAc solution (pH 3.6) as the mobile phase at a flow rate of 1.0 ml min(-1). The precision (R.S.D.) for eight replicate injections of a mixture of 100 microg l(-1) of Cr(III) and Cr(VI) were 0.6 and 0.5% for the retention time, 4.1 and 4.6% for the peak area measurement, respectively. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for HPLC separation and in the initial solution, was 65 for Cr(III) and 19 for Cr(VI). The linear concentration range was from 50 to 1000 microg l(-1) for Cr(III) and 50-2000 microg l(-1) for Cr(VI). The detection limits of Cr(III) and Cr(VI) were 3.4 and 5.2 microg l(-1), respectively. The developed method was applied to the speciation of Cr(III) and Cr(VI) in snow water, river water, seawater and wastewater samples.  相似文献   

15.
A flow injection procedure for the sequential spectrophotometric determination of iron(II) and iron(III) in pharmaceutical products is described. The method is based on the catalytic effect of iron(II) on the oxidation of iodide by bromate at pH = 4.0. The reaction was monitored spectrophotometrically by measuring the absorbance of produced triiodide ion at 352 nm. The activating effect for the catalysis of iron(II) was extremely exhibited in the presence of oxalate ions, while oxalate acted as a masking agent for iron(III). The iron(III) in a sample solution could be determined by passing through a Cd-Hg reductor column introduced in the FIA system to reduce iron(III) to iron(II), which allows total iron determination. Under the optimum conditions, iron(II) and iron(III) could be determined over the range of 0.05 - 5.0 and 0.10 - 5.0 microg ml(-1), respectively with a sampling rate of 17 +/- 5 h(-1). The experimental limits of detection were 0.03 and 0.04 microg ml(-1) for iron(II) and iron(III), respectively. The proposed method was successfully applied to the speciation of iron in pharmaceutical products.  相似文献   

16.
Solvent sublation has been studied for the separation and determination of trace iron(II) in various kinds of water samples. A strongly magenta-colored anionic [Fe(FZ)3](4-) complex was formed at pH 5.0 upon adding 3-(2-pyridyl)-5,6-bis(4-phenylsulfonic acid)-1,2,4-triazine (ferrozine, FZ) to the sample solution. Tetrabutylammonium bromide (TBAB) was added in the solution to form the (TBA)4[Fe(FZ)3)] ion pair, and an oleic acid (HOL) surfactant was added. Then, the (TBA)4[Fe(FZ)3] ion pairs were floated by vigorous shaking in the flotation cell and extracted into methyl isobutyl ketone (MIBK) on the surface of the aqueous solution. The iron collected in the MIBK layer was measured directly by spectrophotometry and/or flame atomic-absorption spectrophotometry. Different experimental variables that may affect the sublation efficiency were thoroughly investigated. The molar absorptivity of the (TBA)4[Fe(FZ)3] ion pair was 2.8 x 10(4) l mol(-1) cm(-1) in the aqueous layer. Beer's law held up to 1.0 mg L(-1) Fe(II) in the aqueous as well as in the organic layers. The adopted solvent sublation method was successfully applied for the determination of Fe(II) in natural water samples with a preconcentration factor of 200. The application was extended to determine iron in pharmaceutical samples.  相似文献   

17.
A simple spectrophotometric system, based on a prolonged pseudo-liquid drop device as an optical cell and a handheld charge coupled device (CCD) as a detector, was constructed for automatic liquid-liquid extraction and spectrophotometric speciation of trace Cr(VI) and Cr(III) in water samples. A tungsten halogen lamp was used as the light source, and a laboratory-constructed T-tube with two open ends was used to form the prolonged pseudo-liquid drop inside the tube. In the medium of perchloric acid solution, Cr(VI) reacted with 1,5-diphenylcarbazide (DPC); the formed complex was automatically extracted into n-pentanol, with a preconcentration ratio of about 5. The organic phase with extracted chromium complex was then pumped through the optical cell for absorbance measurement at 548 nm. Under optimal conditions, the calibration curve was linear in the range of 7.5 - 350 microg L(-1), with a correlation coefficient of 0.9993. The limit of detection (3sigma) was 7.5 microg L(-1). That Cr(III) species cannot react with DPC, but can be oxidized to Cr(VI) prior to determination, is the basis of the speciation analysis. The proposed speciation analysis was sensitive, yet simple, labor-effective, and cost-effective. It has been preliminarily applied for the speciation of Cr(VI) and Cr(III) in spiked river and tap water samples. It can also be used for other automatic liquid-liquid extraction-spectrophotometric determinations.  相似文献   

18.
Nano-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nano-ESI-FTICRMS) was employed for the analysis of the phytosiderophore 2'-deoxymugineic acid (DMA) and the candidate ligand for the intracellular iron transport in plants nicotianamine (NA). Due to the zwitterionic nature of NA and DMA, complementary mass spectra were obtained in positive and negative ionization modes. The technique was also used for speciation of their complexes with Fe(II) and Fe(III), respectively. The species observed at pH 7.3 are the 1:1 Fe-ligand complexes and no evidence for the existence of dimeric complexes was observed. NA and DMA differ only by one mass unit. Consequently, in the system NA + DMA + Fe(II)/Fe(III), there are pairs of iron species (i.e. NA-Fe(II) and DMA-Fe(III)) with the same nominal mass, which differ only by approximately 0.02 mass units. It is shown that high-resolution MS accompanied by accurate mass data analysis allows the unequivocal identification of all four iron species (NA-Fe(II), NA-Fe(III), DMA-Fe(II), DMA-Fe(III)) in one solution without separation. We also addressed the possible alteration of the oxidation state of chelated iron under nano-ESI conditions, but no redox reactions were observed under optimized conditions.  相似文献   

19.
A membrane filtration method was examined concerning the effective collection of iron(III) from a homogeneous aqueous solution with Chromazurol B (CAB), one of the triphenylmethane dyes, as a precipitating reagent in the presence of a non-ionic surfactant, polyethylene glycol mono[4-(1,1,3,3-tetramethylbutyl)phenyl]ether (Triton X-100). A formed blue Fe(III)-CAB complex was collected as a precipitate on a membrane filter by filtration under suction from a homogeneous aqueous solution in the pH range over about 2. The original solution was prepared at a concentration ratio of CAB to Fe(III) of to 10, and that of Triton X-100 to CAB of 10 to 100. It was then adjusted to a pH value of between 1.0 and 6.5. A linear relationship (r = 0.999) was obtained between the initial concentration and the found one of Fe(III) in the range of 2.0 x 10(-5) to 4.0 x 10(-4) mol dm(-3) at a fixed concentration ratio of CAB to Fe(III) of 3 and that of Triton X-100 to CAB of 20. This membrane filtration with CAB and Triton X-100 may be utilized for the separation of Fe(III) as a background species.  相似文献   

20.
Determination of iron speciation in water is one of the major challenges in environmental analytical chemistry. Here, we present and discuss a method for sampling and analysis of dissolved Fe(II), Fe(III), and Fetotal concentrations in natural thermal water covering a wide range of temperature, pH, chemical composition, and redox conditions. Various methods were tried in the collection, preservation, and storage of natural thermal water samples for the Fe(II) and Fe(III) determinations, yet the resultant Fe speciation determined was often found to be significantly affected by the methodology applied. Due to difficulties in preserving accurate Fe speciation in natural samples for later laboratory analysis, a field-deployed on-site method using ion-chromatography and spectrophotometry was developed and tested. The IC-Vis method takes advantage of ion chromatographic separation of Fe(II) and Fe(III), followed by post-column colour reaction and spectrophotometric detection, thus allowing analysis of Fe(II) and Fe(III) in a single 15-minute run. Additionally, Fetotal can be determined after sample oxidation. The analytical detection limits are ~2 µg L?1 (LOD) using 200–1000 µL injection volumes and depend on the blank and reagent quality. The power of this method relies on the capability to directly determine a wide range of absolute and relative concentrations of Fe(II) and Fe(III) in the field. The field-deployed IC-Vis method was applied for the determination of Fe(II) and Fe(III) concentrations in natural thermal water with discharge temperatures ranging from 12°C to 95°C, pH between 2.46 and 9.75, and Fetotal concentrations ranging from a few μg L?c up to 8.3 mg L?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号