首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shi H  Yang Y  Huang J  Zhao Z  Xu X  Anzai J  Osa T  Chen Q 《Talanta》2006,70(4):852-858
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 × 10−7 M), short response time (within 10 s), high sensitivity (88.6 μA mM−1 cm−2) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 ± 0.001) ×10−3 M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method.  相似文献   

2.
We report on a novel hydrogen peroxide biosensor that was fabricated by the layer-by-layer deposition method. Thionine was first deposited on a glassy carbon electrode by two-step electropolymerization to form a positively charged surface. The negatively charged gold nanoparticles and positively charged horseradish peroxidase were then immobilized onto the electrode via electrostatic adsorption. The sequential deposition process was characterized using electrochemical impedance spectroscopy by monitoring the impedance change of the electrode surface during the construction process. The electrochemical behaviour of the modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. The effects of the experimental variables on the amperometric determination of H2O2 such as solution pH and applied potential were investigated for optimum analytical performance. Under the optimized conditions, the biosensor exhibited linear response to H2O2 in the concentration ranges from 0.20 to 1.6?mM and 1.6 to 4.0?mM, with a detection limit of 0.067?mM (at an S/N of 3). In addition, the stability and reproducibility of this biosensor was also evaluated and gave satisfactory results.
Figure
A novel hydrogen peroxide biosensor was fabricated via layer-by-layer depositing approach. Thionine was first deposited on a glassy carbon electrode by electropolymerization to form a positively charged surface (PTH). Negatively charged gold nanoparticles (NPs) and positively charged horseradish peroxidase (HRP) were then immobilized onto the electrode via electrostatic adsorption.  相似文献   

3.
A novel non-enzymatic electrochemical sensor based on a nanoporous gold electrode modified with platinum nanoparticles was constructed for the determination of hydrogen peroxide (H2O2). Platinum nanoparticles exhibit good electrocatalytic activity towards hydrogen peroxide. The nanoporous gold (NPG) increases the effective surface area and has the capacity to promote electron-transfer reactions. With electrodeposition of Pt nanoparticles (NPs) on the surface of the nanoporous gold, the modified Au electrode afforded a fast, sensitive and selective electrochemical method for the determination of H2O2. The linear range for the detection of H2O2 was from 1.0 × 10?7 M to 2.0 × 10?5 M while the calculated limit of detection was 7.2 × 10?8 M on the basis of the 3σ/slope (σ represents the standard deviation of the blank samples). These findings could lead to the widespread use of electrochemical sensors to detect H2O2.  相似文献   

4.
Wang Q  Yang L  Yang X  Wang K  He L  Zhu J 《Analytica chimica acta》2011,688(2):1157-167
An electrochemical method for point mutation detection based on surface ligation reaction and oligonucleotides (ODNs) modified gold nanoparticles (AuNPs) was demonstrated. Point mutation identification was achieved using Escherichia coli DNA ligase. This system for point mutation detection relied on a sandwich assay comprising capture ODN immobilized on Au electrodes, target ODN and ligation ODN. Because of the sequence-specific surface reactions of E. coli DNA ligase, the ligation ODN covalently linked to the capture ODN only in the presence of a perfectly complementary target ODN. The presence of ligation products on Au electrode was detected using chronocoulometry through hybridization with reporter ODN modified AuNPs. The use of AuNPs improved the sensitivity of chronocoulometry in this approach, a detection limit of 0.9 pM complementary ODN was obtained. For single base mismatched ODN (smODN), a negligible signal was observed. Even if the concentration ratio of complementary ODN to smODN was decreased to 1:1000, a detectable signal was observed. This work may provide a specific, sensitive and cost-efficient approach for point mutant detection.  相似文献   

5.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer.
Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum.  相似文献   

6.
The modification of carbon-paste electrodes by incorporation of the enzyme glucose oxidase (GOD) is described. The resulting probes can be operated as amperometric glucose sensors in the presence or absence of a mediator (1,1'-dimethylferrocene) mixed into the paste. Extended linear calibration ranges have been obtained up to 90 and 5OmM glucose respectively. The electrode responses were rapid, reaching steady-state values within 30-40 sec. Advantages of using a GOD-paste formulation are suggested. Plasma glucose assays were correlated with spectrophotometric determinations based on glucose oxidase (y = 1.07x - 0.16, r = 0.973, n = 17).  相似文献   

7.
Bismuth modified platinum electrodes are used for constant-potential amperometric determination of carbohydrates in flow systems. The monitored response is stable and reproducible over more than two days. An attempt is made to gain more detailed information about the characteristics of the modified layer by electrochemical methods and X-ray photoelectron spectroscopy. The response proved to be linear over the investigated concentration range (1.1–1200 mol/L) and detection limits for glucose and fructose were found to be 1.1 mol/L.  相似文献   

8.
Cubukçu M  Timur S  Anik U 《Talanta》2007,74(3):434-439
A composite electrode was prepared by modifying glassy carbon microparticles with gold nanoparticles (Au-nps) and xanthine oxidase enzyme (XOD) for xanthine (X) and hypoxanthine (Hx) detection. After the optimization of the system for X, the biosensor was characterized for X and Hx. A linearity was obtained in the concentration range between 5.00 × 10−7 and 1.00 × 10−5 M for X with equation of y = 0.24x + 0.712 and 5.00 × 10−6 to 1.50 × 10−4 M for Hx, with equation of y = 0.014x + 0.575, respectively. Obtained results were compared to X and/or Hx biosensors including/not including Au-np in the structure. The developed system was also applied for detection of Hx in canned tuna fish sample and very promising results were obtained.  相似文献   

9.
Xia Chu  Daxue Duan  Guoli Shen  Ruqin Yu 《Talanta》2007,71(5):2040-2047
A new amperometric biosensor for glucose was developed based on adsorption of glucose oxidase (GOx) at the gold and platinum nanoparticles-modified carbon nanotube (CNT) electrode. CNTs were covalently immobilized on gold electrode via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM). The fabricated GOx/Aunano/Ptnano/CNT electrode was covered with a thin layer of Nafion to avoid the loss of GOx in determination and to improve the anti-interferent ability. The immobilization of CNTs on the gold electrode was characterized by quartz crystal microbalance technique. The morphologies of the CNT/gold and Ptnano/CNT/gold electrodes have been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the gold, CNT/gold, Ptnano/gold and Ptnano/CNT/gold electrodes has also been studied by amperometric method. In addition, effects of electrodeposition time of Pt nanoparticles, pH value, applied potential and electroactive interferents on the amperometric response of the sensor were discussed.

The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for glucose in the absence of a mediator. The linear range was from 0.5 to 17.5 mM with correction coefficient of 0.996. The biosensor had good reproducibility and stability for the determination of glucose.  相似文献   


10.
11.
12.
Chai R  Yuan R  Chai Y  Ou C  Cao S  Li X 《Talanta》2008,74(5):1330-1336
Nano-Au and methylene blue (MB) were assembled layer-by-layer (LBL) into films on the glassy carbon electrode modified by thiourea for detection of human chorionic gonadotrophin (HCG). The electrode modification process was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron micrograph (SEM). The factors influencing the performance of the amperometric immunosensor were studied in detail. Tests performed with this immunosensor showed good linearity, the working range for the system was 1.0–100.0 mIU/mL with a detection limit of 0.3 mIU/mL at 3σ. Moreover, the studied immunosensor exhibited high sensitivity and long-term stability. The present work supplied a promising test method for clinical immunoassay.  相似文献   

13.
Wang  Huiqiang  Ma  Zhanfang 《Mikrochimica acta》2017,184(9):3247-3253
Microchimica Acta - A glassy carbon electrode was modified with a redox-active nanocomposite consisting of polyresorcinol, gold nanoparticles (NPs) and platinum NPs. This nanocomposite possesses...  相似文献   

14.
A facile strategy of an amperometric biosensor for hydrogen peroxide based on the direct electrocatalysis of hemoglobin (Hb) immobilized on gold nanoparticles (GNPs)/1,6-diaminohexane (DAH) modified glassy carbon electrode (GCE) has been described. A uniform monolayer film of DAH was initially covalently bound on a GCE surface by virtue of the electrooxidation of one amino group of DAH, and another amino group was modified with GNPs and Hb, successively. The fabrication process was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The proposed biosensor exhibited an effective and fast catalytic response to the reduction of H2O2 with good reproducibility and stability. A linear relationship existed between the catalytic current and the H2O2 concentration in the range of 1.5x10(-6) to 2.1x10(-3) M with a correlation coefficient of 0.998 (n=24). The detection limit (S/N=3) was 8.8x10(-7) M.  相似文献   

15.
16.
Cai CX  Xue KH  Zhou YM  Yang H 《Talanta》1997,44(3):339-347
Alcohol dehydrogenase (ADH) has been immobilized on a nickel hexacyanoferrate modified microband gold electrode surface by a glutaraldehyde/bovine serum albumin (BSA) cross-linking procedure to provide a new amperometric sensor for the assay of ethanol. The resulting enzyme electrode exhibits excellent electrocatalysis for the oxidation of reduced nicotinamide-adenine dinucleotide (NADH). The amperometric determination is based on the electrochemical detection of NADH which is generated in the enzymatic reaction of ethanol with NAD(+) under catalysis of ADH. The influence of various experimental conditions was examined for the determination of the optimum analytical performance. The sensor responds rapidly to ethanol with a detection limit of (5.0 +/- 0.3) x 10(-7) mol 1(-1). The response current increases linearly with ethanol concentration up to 5 mmol 1(-1). The sensor remains relatively stable for about 1 week.  相似文献   

17.
The construction and response of an immobilized enzyme modified electrode as an amperometric sensor is described. Xanthine oxidase was adsorbed on a carbon paste electrode and physically entrapped with a semipermeable membrane. Uric acid, the product of the enzymatic reaction, was oxidized electrochemically at +0.4 V vs. Ag/AgCl, yielding a steady-state current directly related to the bulk concentration of the substrate. Hypoxanthine and xanthine were determined in the range 5–100 μM at Ph 7.2 with good precision. Interferences are discussed.  相似文献   

18.
Platinum nanoparticles were used in combination with multi-walled carbon nanotubes (MWCNTs) for fabricating sensitivity-enhanced electrochemical DNA biosensor. Multi-walled carbon nanotubes and platinum nanoparticles were dispersed in Nafion, which were used to fabricate the modification of the glassy carbon electrode (GCE) surface. Oligonucleotides with amino groups at the 5′ end were covalently linked onto carboxylic groups of MWCNTs on the electrode. The hybridization events were monitored by differential pulse voltammetry (DPV) measurement of the intercalated daunomycin. Due to the ability of carbon nanotubes to promote electron-transfer reactions, the high catalytic activities of platinum nanoparticles for chemical reactions, the sensitivity of presented electrochemical DNA biosensors was remarkably improved. The detection limit of the method for target DNA was 1.0 × 10−11 mol l−1.  相似文献   

19.
Kyoungseon Min 《Talanta》2009,80(2):1007-191
A novel 3-dimensional single wall carbon nanotubes (SWNTs)-polypyrrole (Ppy) composite was prepared as an electrode by chemically polymerizing polypyrrole onto SWNTs using a LiClO4 oxidant. This composite electrode was characterized by scanning electron microscopy (SEM) and cyclic voltammetry with 1 mM [Fe(CN)6]−3/[Fe(CN)6]−4. The SWNTs were thickly coated with chemically polymerized polypyrrole and the composite had many surface pores and crevices which could enhance mass transfer. The SWNTs-Ppy composite electrode showed a large specific surface area (30 m2/g) and a good reproducible current response, at about 100 times the peak current of a glassy carbon electrode (GCE). The diffusion coefficient was calculated to be 4.81 × 10−6 cm2/s. As a biosensor application, tyrosinase was immobilized on the functionalized SWNTs and tyrosinase-SWNTs-Ppy composite was prepared in the same manner. This tyrosinase-SWNT-Ppy composite electrode was used for amperometric detection of dopamine in the presence of ascorbic acid and showed high sensitivity (467 mA/M cm2) and lower detection limit (5 μM) compared to previous reports.  相似文献   

20.
Xu  Liang  Lian  Meiling  Chen  Xu  Lu  Yanluo  Yang  Wensheng 《Mikrochimica acta》2017,184(10):3989-3996
Microchimica Acta - An electrochemical sensor for hydrogen peroxide (H2O2) has been fabricated by electrodepositing gold nanoparticles (AuNPs) on an indium tin oxide (ITO) electrode modified with...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号