首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
Zhong H  Yun D  Zhang C  Yang P  Fan H  He F 《Electrophoresis》2008,29(11):2372-2380
In this study, ampholyte-free liquid-phase IEF (LIEF) was combined with narrow pH range 2-DE and SDS-PAGE RP-HPLC for comprehensive analysis of mouse liver proteome. Because LIEF prefractionation was able to reduce the complexity of the sample and enhance the loading capacity of IEF strips, the number of visible protein spots on subsequent 2-DE gels was significantly increased. A total of 6271 protein spots were detected after integrating five narrow pH range 2-DE gels following LIEF prefractionation into a single virtual 2-DE gel. Furthermore, the pH 3-5 LIEF fraction and the unfractionated sample were separated by pH 3-6 2-DE and identified by MALDI-TOF/TOF MS, respectively. In parallel, the pH 3-5 LIEF fraction was also analyzed by SDS-PAGE RP-HPLC MS/MS. LIEF-2-DE and LIEF-HPLC could obviously improve the separation efficiency and the confidence of protein identification, which identified a higher number of low-abundance proteins and proteins with extreme physicochemical characteristics or post-translational modifications compared to conventional 2-DE method. Furthermore, there were 207 proteins newly identified in mouse liver in comparison with previously reported large-scale datasets. It was observed that the combination of LIEF-2-DE and LIEF-HPLC was effective in promoting MS-based liver proteome profiling and could be applied on similar complex tissue samples.  相似文献   

2.
Cerebrospinal fluid (CSF) is in close proximity to the brain and changes in the protein composition of CSF may be indicative of altered brain protein expression in neurodegenerative disorders. Analysis of brain-specific proteins in CSF is complicated by the fact that most CSF proteins are derived from the plasma and tend to obscure less abundant proteins. By adopting a prefractionation step prior to two-dimensional gel electrophoresis (2-DE), less abundant proteins are enriched and can be detected in complex proteomes such as CSF. We have developed a method in which liquid-phase isoelectric focusing (IEF) is used to prefractionate individual CSF samples; selected IEF fractions are then analysed on SYPRO-Ruby-stained 2-D gels, with final protein identification by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). To optimise the focusing of the protein spots on the 2-D gel, the ampholyte concentration in liquid-phase IEF was minimised and the focusing time in the first dimension was increased. When comparing 2-D gels from individual prefractionated and unfractionated CSF samples it is evident that individual protein spots are larger and contain more protein after prefractionation of CSF. Generally, more protein spots were also detected in the 2-D gels from prefractionated CSF compared with direct 2-DE separations of CSF. Several proteins, including cystatin C, IgM-kappa, hemopexin, acetyl-coenzyme A carboxylase-alpha, and alpha-1-acid glycoprotein, were identified in prefractionated CSF but not in unfractionated CSF. Low abundant forms of posttranslationally modified proteins, e.g. alpha-1-acid glycoprotein and alpha-2-HS glycoprotein, can be enriched, thus better resolved and detected on the 2-D gel. Liquid-phase IEF, as a prefractionation step prior to 2-DE, reduce sample complexity, facilitate detection of less abundant protein components, increases the protein loads and the protein amount in each gel spot for MALDI-MS analysis.  相似文献   

3.
Danos O  Svinartchouk F 《Electrophoresis》2006,27(17):3475-3479
2-DE is an important tool in proteomics research. However, intrinsic gel-to-gel variability of 2-DE often masks the biological differences between the samples and compromises quantitative comparison of protein expression levels. Here, we describe a modification of 2-DE that results in improved matching and quantification of proteins. This was accomplished by performing IEF of two samples in two IPG strips separated by a dialysis membrane. After IEF running, the strips were separated and the SDS-PAGE dimension was accomplished on two individual gels. After gel staining with CBB, ImageMaster 2D Platinum software (Amersham) was used for spot detection and quantification. Analysis of protein extracts from C2C12 myoblasts by this method resulted in 99% spot-matching efficiency and CV in stain intensity (% volume) was less than 0.5 for 98% of spots. We conclude that this technique, called dialysis-assisted gel electrophoresis, gives superior spot matching and quantitative reproducibility compared to IEF conducted on separate strips.  相似文献   

4.
Proteomic approaches including high-resolution 2-DE are providing the tools needed to discover disease-associated biomarkers in complex biological samples. Although 2-DE is an extremely powerful approach to analyze the proteome, the separation of proteins with extreme molecular masses still remains an issue requiring improvement. Because high molecular mass (HMM) proteins larger than 150 kDa have already been observed to be differentially expressed in several pathologies such as cancer, we developed an original strategy to analyze this part of the proteome that is not easily separated by 2-DE in polyacrylamide gels. This strategy is based on the 2-DE separation of cyanogen bromide (CNBr) fragments of purified HMM protein fractions, and combines techniques including SEC fractionation, TCA precipitation, CNBr cleavage, 2-DE and MS analysis. The method was first tested on a model protein, the BSA. Preliminary results obtained using colonic tissues led to the identification of six HMM proteins with M(r) comprised between 163 and 533 kDa in their reduced state. These results demonstrated that our CNBr/2-DE approach should provide a powerful tool for identification of new biomarkers larger than 150 kDa.  相似文献   

5.
Despite the large number of papers dealing with bacterial proteomes, very few include information about proteins with alkaline pI's, because of the limits inherent in 2-DE technology. Nonetheless, analyses of in silico proteomes of many prokaryotes show a bimodal distribution of their proteins based on their pI's; the most crowded areas lying between pI 4-7 and 9-11. The aim of the present research was to set up a general, simple, and standardizable 2-DE protocol suitable for studying the alkaline proteome of Lactobacillus hilgardii, a Gram-positive bacillus isolated from wine. The method has also been tested on a Gram-negative bacterium able to degrade aromatic pollutants, Acinetobacter radioresistens S13. Optimization of the method was mainly focused on improving protein extraction and IEF (pI 6-11) separation protocols. Concerning IEF, different methods for sample loading (in-gel rehydration and cup loading), and different reducing agents (DTT and bis(2-hydroxyethyl) disulfide (HED)) were tested and compared. The proposed protocol was found to resolve efficiently alkaline proteins from both of our Lactobacillus and Acinetobacter strains, in spite of their different external layers, thus, enabling a more comprehensive study of their proteomes.  相似文献   

6.
J Asakawa 《Electrophoresis》1988,9(9):562-568
Two-dimensional electrophoresis (2-DE) with immobilized pH gradient (IPG) gels in capillary tubes was used in the first-dimensional isoelectric focusing (IEF) for the separation of human platelet polypeptides. Two types of IPG tube gels, pH ranges 4-8 and 7-10, containing 8 M urea, 1% Nonidet P-40 and 0.1% pH 3.5-10 Ampholine carrier ampholytes (CA) were prepared by a simple method not requiring special equipment. The addition of CA to both gel and sample solutions was essential in the tube gel IPG system. Proteins were visualized by a modification of Wray's silver-staining technique. The degree of resolution and the number of spots observed on an IPG 2-DE gel with pH 4-8 were comparable with those obtained with O'Farrell's high-resolution 2-DE. Approximately 200 basic polypeptides, which are difficult to separate by conventional CA-based IEF 2-DE or the non-equilibrium pH gradient system, were well resolved by 2-DE with a pH 7-10 IPG tube gel in the first-dimension. The gel patterns with either pH gradient 4-8 or 7-10 were highly reproducible among gels prepared and run simultaneously. These results demonstrated the potential and usefulness of the 2-DE system with IPG gels in capillary tubes.  相似文献   

7.
Two-dimensional electrophoresis of membrane proteins   总被引:1,自引:0,他引:1  
One third of all genes of various organisms encode membrane proteins, emphasizing their crucial cellular role. However, due to their high hydrophobicity, membrane proteins demonstrate low solubility and a high tendency for aggregation. Indeed, conventional two-dimensional gel electrophoresis (2-DE), a powerful electrophoretic method for the separation of complex protein samples that applies isoelectric focusing (IEF) in the first dimension and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) in the second dimension, has a strong bias against membrane proteins. This review describes two-dimensional electrophoretic techniques that can be used to separate membrane proteins. Alternative methods for performing conventional 2-DE are highlighted; these involve replacing the IEF with electrophoresis using cationic detergents, namely 16-benzyldimethyl-n-hexadecylammonium chloride (16-BAC) and cetyl trimethyl ammonium bromide (CTAB), or the anionic detergent SDS. Finally, the separation of native membrane protein complexes through the application of blue and clear native gel electrophoresis (BN/CN-PAGE) is reviewed, as well as the free-flow electrophoresis (FFE) of membranes.  相似文献   

8.
A new isoelectric focusing (IEF) system for two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) has been proposed. In this system, a super-soft and tough IEF gel was achieved by casting polyacrylamide gel down to 2.0% T using a loose multifilament string (LMS) of nylon as a gel support. The IEF apparatus for the LMS-gel, fabricated from acrylic boards, had a cooling water chamber, and eliminated the need of electrode solutions by directly connecting the two ends of individual gels to platinum electrodes. The carrier ampholyte-generated pH gradients using the new IEF system was stable over a long duration of time and a wide range of voltages, and the IEF time became shorter using a 2.0% T gel than using a 4.0% T gel. Also, the LMS-gels prepared in different runs exhibited excellent reproducibility. The new IEF system was applied to 2-D PAGE of a chicken skeletal muscle extract, and it was found that the protein loading capacity, protein entry into the LMS-gels, and protein transfer efficiency from the first-dimensional to the second-dimensional gels were significantly improved by using a low-concentration (2.5% T) gel. Also, proteins of high molecular weight of more than 200 kDa were observed in the 2-D maps, and therefore the new IEF system has a very good potential to be applied for fast 2-D PAGE of high molecular-weight proteins.  相似文献   

9.
We describe a miniaturized instrument capable of performing 2-DE. Our miniaturized device is able to perform IEF and polyacrylamide slab gel electrophoresis (PASGE) in the same unit. It consists of a compartment for a first-dimensional IEF gel, which is connected to a second-dimensional PASGE gel. The focused samples are automatically transferred from the IEF gel to the PASGE gel by electromigration. Our preliminary experiments show that the device is able to focus and separate a mixture of proteins in approximately 1 h, excluding the time required for the staining procedure. On average, the gel-to-gel retardation factor (Rf) variation was 6.2% (+/-0.9%) and pI variation was 2.5% (+/-0.6%). Separated protein spots were excised from stained gels, digested with trypsin, and further identified by MS, thus enabling direct proteomic analysis of the separated proteins.  相似文献   

10.
Large-pore-size agarose gels provide excellent resolving capacity for high molecular weight biomolecules. Thin-layer agarose isoelectric focusing (IEF) gels on polyester support films are especially useful for the separation of large proteins based on their pI in native conformation, but the method has suffered from the lack of detection methods compatible with agarose gels in hydrated form. Recently, an acrylamide copolymerization method was reported to enable mass-spectrometry-compatible silver staining and in-gel digestion of proteins. In this study, the method was further applied by demonstrating successful reverse imidazole-zinc staining of thin-layer agarose IEF gels copolymerized with acrylamide. The sensitivity of the reverse staining method on the composite gel at its best equaled the sensitivity of the traditional dried agarose silver staining method. Owing to the increased durability and reversible detection, the reverse-stained first-dimension gel could be conveniently prepared for the second-dimension sodium dodecyl sulfate polyacrylamide gel electrophoresis by reduction and alkylation. In addition, the micropreparative generation of tryptic peptides of Coomassie brilliant blue R-250 stained proteins in the composite gel is demonstrated.  相似文献   

11.
Ruan Y  Wan M 《Electrophoresis》2007,28(18):3333-3340
The separation of integral and peripheral membrane proteins is still a challenge, although many achievements have been made in the 2-DE-based membrane proteomics. Using a human breast cancer cell line, MCF-7, we investigated the influences of Tris, reducing reagents, cup loading, and SDS on membrane protein solubilization and separation by 2-DE. The addition of Tris to the sample solution improved the solubilization of the membrane-enriched fraction, and the best-quality gel patterns were obtained at 20 mM Tris. Tributylphosphine (TBP), a reducing agent, was not optimum in the 2-DE process because it not only decreased the solubilization of hydrophobic proteins but also caused some proteins, such as hsp60, prohibitin, and actin, to be resolved to a string of spots. However, when combined with DTT, TBP could improve the resolution of 2-DE patterns. Cup loading significantly facilitated the entrance of membrane proteins into IPG strips and over 1000 protein spots with high resolution were visualized. Adopting this strategy, an ATP synthase alpha chain was resolved into two adjacent spots for the first time in 2-DE gel patterns through the adding DTT in the middle of the IEF. A high SDS concentration in the equilibration buffer enhanced the transfer and increased the staining intensity of 50% of the protein spots in the gels, but also resulted in losses of some spots.  相似文献   

12.
Human alpha-fetoprotein (AFP) from serum of patients with cirrhosis and hepatocellular carcinoma (HCC) was separated into several bands by IEF and by erythroagglutinating phytohemagglutinin (E-PHA) affinity electrophoresis. These AFP bands were directly compared in 2-D IEF and E-PHA affinity electrophoresis. IEF of serum AFP was run in 1% agarose IEF gel with 3% Pharmalyte 4.5-5.4. After IEF, a part of the gel was stained for AFP and another part of the gel corresponding to the area of separated AFP bands was cut in 1 mm x 39 mm along the focused direction and transferred to a trough in 1% agarose gel with 0.3 mg/mL E(4)-PHA for second-dimensional affinity electrophoresis. Separated 2-D AFP spots were visualized by antibody-affinity blotting and identified by combining the systems of Johnson et al.. (Johnson, P. J., Ho, S., Cheng, P., Chan, A. et al.., Cancer 1995, 75, 1663-1668) for AFP-I-+IV and of Taketa et al.. (Taketa, K., Ichikawa, E., Taga, H., Hirai, H., Electrophoresis 1985, 6, 492-497) for AFP-P1-5. AFP-P2, the major AFP glycoform, was composed of AFP-I, AFP+I, and AFP+II; AFP-P3, a nonspecific monosialo-AFP, was composed of AFP+II; AFP-P4, HCC-specific monosialo-AFP, was composed of AFP+II, AFP+III, and AFP+IV; and malignancy-related AFP-P5 was composed of AFP+I and AFP+II. Monosialo-AFP (AFP+II) was recovered in all the glycoforms of AFP-P2, -P3, -P4, and -P5; thus, AFP-P4 is more specific to HCC than monosialylated AFP+II.  相似文献   

13.
This paper investigates the preparation of Fasciola hepatica samples for two-dimensional electrophoresis (2-DE). Whole samples were prepared by both hot sodium dodecyl sulfate (SDS) solubilisation and precipitation using trichloroacetic acid (TCA) to remove nonprotein contaminants and to inactivate endogenous proteases. Sample preparation had a marked influence on the 2-DE gel profile. TCA precipitation resulted in no measurable improvement in the profile observed, compared to the untreated control. Solubilisation of sample with hot SDS increased the number of protein spots, as did TCA precipitation with the addition of phosphotungstic acid. The preparation of excretory-secretory (ES) products poses problems due to both high salt concentrations and low protein concentration. All precipitation methods used to overcome this gave similar profiles, except acetone alone, which caused depletion of the larger proteins. TCA in acetone gave the best result, similar to that obtained by centrifugal filtration of the sample. Overcrowding of spots in some regions of the 2-DE gel occurred in the whole Fasciola hepatica sample. This problem was alleviated by differential solubilisation, which also resulted in the enrichment of some proteins.  相似文献   

14.
2-DE proved to be a key technology in protein science since the two orthogonal separation dimensions are capable of protein isoform separation. Recently, Agilent introduced the OFFGEL 3100 fractionator for in solution IEF (off-gel) of proteins with the help of a 12- or 24-well frame. With this instrument also conventional focusing in IPG strips after passive in-tray rehydration can be performed. In this study, two novel IEF applications using the OFFGEL electrophoresis were developed. First, a sample cup was built and a cup-loading method for the OFFGEL device was implemented. Applying proteins via cup resulted in higher reproducibility and less protein loss compared with conventional in-tray rehydration loading. Especially, the recovery of basic and high-molecular-mass proteins seems to be favored by cup loading. These effects are more pronounced with low microgram sample amounts. Second, a 48-well OFFGEL frame was developed, which doubles the resolution of the commercially available 24-well frame. It is capable of separating proteins with small pI differences and shows potential for isoform/PTM separation.  相似文献   

15.
Despite its excellent resolving power, 2-DE is of limited use when analyzing cellular proteomes, especially in differential expression studies. Frequently, fewer than 2000 protein spots are detected on a single 2-D gel (a fraction of the total proteome) regardless of the gel platform, sample, or detection method used. This is due to the vast number of proteins expressed and their equally vast dynamic range. To exploit 2-DE unique ability as both an analytical and a preparative tool, the significant sample prefractionation is necessary. We have used solution isoelectric focusing (sIEF) via the ZOOM IEF Fractionator (Invitrogen) to generate sample fractions from complex bacterial lysates, followed by parallel 2-DE, using narrow-range IPG strips that bracket the sIEF fractions. The net result of this process is a significant enrichment of the bacterial proteome resolved on multiple 2-D gels. After prefractionation, we detected 5525 spots, an approximate 3.5-fold increase over the 1577 spots detected in an unfractionated gel. We concluded that sIEF is an effective means of prefractionation to increase depth of field and improve the analysis of low-abundance proteins.  相似文献   

16.
Jin Y  Manabe T 《Electrophoresis》2007,28(3):449-459
Previously, we have reported a high-efficiency method of protein extraction from CBB-stained polyacrylamide gels for molecular mass measurement with MALDI-TOF MS [1]. In the present work, the alkaline extraction method was applied to CBB-stained 2-DE gels on which human plasma proteins were separated in the absence of denaturant. In order to examine the performance of the method, ten spots with apparent molecular masses (MMapp) in the range of 65 to 1000 kDa were selected and the proteins were extracted from the gel pieces. The extracts were subjected to whole-mass measurement by MALDI-TOF MS, with and without DTT treatment. In addition, the extracts were subjected to in-solution trypsin digestion followed by MALDI-TOF MS and PMF analysis. Successful extraction of proteins from the ten spots, up to MMapp 1000 kDa, has been ascertained by the significant PMF assignment (MASCOT) with high sequence coverage of the respective proteins or polypeptides. When direct mass measurement of the extracted proteins was attempted, three spots in MMapp range 65-100 kDa provided mass peaks. Five spots in MMapp range 150-400 kDa did not give mass peaks of the intact proteins, but showed those of the constituent polypeptides after the DTT treatment. Extraction of proteins prior to trypsin digestion enabled the procedure of PMF analysis to be much simpler than the conventional in-gel digestion method, providing comparable protein scores and sequence coverage. The technique presented here suggests a new strategy for the characterization of proteins separated by nondenaturing 2-DE.  相似文献   

17.
The human milk fat globule membrane protein composition is still largely unknown, although it counts for 2-4% of the total milk protein content and contains several important biologically active components. The aim of this work was to create a two-dimensional electrophoresis (2-DE) map of the human milk fat globule membrane proteins, both integral and membrane-associated, and to identify and characterize as many protein components as possible. A new protocol for the solubilization and extraction of the human milk fat globule membrane proteins with a double extraction procedure is presented, and the results compared with the extraction methods reported in the literature. The proteins were separated, in the first dimension, by isoelectric focusing (IEF) in the pH range 3-10 on strips of 13 cm length and, in the second dimension, by Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) on 11.5% T homogeneous gels. A reproducible 2-DE map of integral and membrane-associated proteins was obtained and the first 23 spots, representing the major components, were identified by matrix assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometric analysis and/or by amino acid sequencing.  相似文献   

18.
Gao Y  Chen C  Chai Z  Zhao J  Liu J  Zhang P  Heb aW  Huang Y 《The Analyst》2002,127(12):1700-1704
Synchrotron radiation X-ray fluorescence (SRXRF) spectroscopy is an advanced method of quantitative multielemental analysis with space resolution of several microm and sensitivities in the microg g(-1) range. It can be used for keeping track of trace elements after an electrophoretic separation of biological samples. In this paper, proteins in human liver cytosol were separated with gel filtration chromatography and thin layer isoelectric focusing (IEF). The contents of metal ions in protein bands were determined by SRXRF. The results showed that in the molecular weight (MW) range of 10 approximately 25 kDa, there were at least 2 Zn-containing bands with isoelectric point (pI) of 5 approximately 6 and 6.2 approximately 7, respectively and about 11 Fe-containing proteins with pI of 4.4, 4.6, 4.8, 5.0, 5.2, 5.3, 5.5, 5.6, 6.6, 6.8, and 7.2, respectively, present in human liver cytosol. The Zn-containing band with pI of 5-6 is the dominant species of zinc in this MW range. In addition, the Cu-containing bands with pI of 5.0 and below 4.8 were also detected. It is demonstrated that the procedure could be widely used in further investigations of the chemical species of trace elements in biological samples.  相似文献   

19.
Due to their poor solubility during IEF membrane proteins cannot be separated and analyzed satisfactorily with classical 2-DE. A more efficient method for such hydrophobic proteins is the benzyldimethyl-n-hexadecylammonium chloride (16-BAC)/SDS-PAGE, but the corresponding protocol is intricate and time-consuming. We now developed an easy-to-handle electrophoresis method in connection with a novel device which enables reproducible separation of ionic solubilized membrane proteins using individually rehydrated plastic sheet gel strips. These strips are suitable for the first dimension in a 2-D 16-BAC/SDS system and can be handled easily; this is demonstrated by the separation of membrane proteins of human embryonic kidney (HEK293) cells.  相似文献   

20.
The use of cup-loading for sample application has become widely used in two-dimensional electrophoresis (2-DE) for resolution of basic proteins, but no side-by-side quantitative study has been published which compares cup-loading with the alternative passive and active rehydration methods to fully promote one type of loading method over another. Replicate 2-D gels from each loading method were quantitatively evaluated for gel-to-gel reproducibility using IPG 6-11 strips and semipreparative protein loads (300 microg). Gels were stained with SYPRO Ruby and analyzed with PDQuest. An inexpensive home-made assembly for cup-loading was used with the Protean IEF Cell for separation of whole cell extracts from the archaeon, Sulfolobus solfataricus. Cup-loading was determined to be far superior for IPG 6-11 separations than active or passive rehydration methods. Cup-loading consistently produced the greatest number of detectable spots, the best spot matching efficiency (56%), lowest spot quantity variations (28% coefficient of variation, CV), and the best-looking gels qualitatively. The least satisfactory results were obtained with active rehydration, followed closely by passive rehydration in off-line tubes. Passive rehydration experiments, performed using an on-line isoelectric focusing (IEF) tray, produced comparable spot numbers to cup-loading (84%), with 55% of the spots having higher intensity but 10% more spot quantity variance than cup-loading.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号