首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Over a range of Reynolds numbers from 0·6 × 105 to 1·75 × 105 tests were made on a seven rows deep tube bank. These tests were made using a specially instrumented porous cylinder which could be located in any position within the bank. Mass transfer through the porous surface simulating the condensation process in a surface condenser, was applied, and its effect on local parameters investigated. The distribution of static pressure and skin friction was determined around tubes in different rows in the bank. From these measurements, the pressure drag and friction drag were estimated. The total pressure drop across the bank was also measured.

Results showed that, for typical steam condenser loadings, the contribution of the pressure drag to the total drag does not change appreciably with suction. However, the skin friction contribution does change considerably with suction.  相似文献   


2.
The experimental data for heat transfer during nucleate pool boiling of saturated liquid metals on plain surfaces are surveyed and a new correlation is presented. The correlation is h = Cq0.7prm, where C and m are, respectively, 13.7 and 0.22 pr < 0.001 and 6.9 and 0.12 for pr > 0.001 (h is in W/m2 K and q in W/m2). This correlation has been verified with data for K, Na, Cs, Li, and Hg from 17 sources over the reduced pressure (pr) range of 4.3 × 10−6 to 1.8 × 10−2. The correlation of Subbotin et al. was found unsatisfactory, but a modified correlation was developed that also gives good agreement with most of the data.  相似文献   

3.
An experimental investigation was carried out on the heat transfer due to a submerged slot jet of water impinging on a circular cylinder in crossflow. The cylinder diameter and the slot width are of the same order of magnitude, specifically Ds = 2.0 and 3.0 mm and Dc = 2.5 and 3.0 mm. The experimental apparatus allowed variation of the slot width, the cylinder diameter, and the distance from nozxle exit to heater. Conditions of impingement from the bottom (ascending flow) were taken into consideration as well as impingement from above (descending flow). The Nusselt number was determined as a function of Reynolds and Prandtl numbers in the range 1.5 × 103 < Re < 2.0 × 104, 2.7 < Pr < 7.0, and 1.5 ≤ z/Ds ≤ 10. The experimental data were correlated with a simple equation that fits 90% of the data with a precision of 20%.  相似文献   

4.
The structural character and steady-state statistics of the turbulence inside a rib-wall circular duct is investigated by the large-eddy simulation (LES) methodology. The impetus of this study is to gain an understanding of the principle physics attributing to minimizing the pressure recovered (or maximizing the pressure loss) within the core flow. For a rib periodicity with height (h) to pitch (p) ratio p/h=5, the computational results show that the majority of turbulence produced due to the rib’s presence is concentrated near the rib crest leading edge. Pairs of counter-rotating streamwise vortices form soon after the leading edge that are quickly convected radially toward the core flow. The turbulent activity within the duct trough region is negligible compared to the turbulence levels of the core flow. At this rib periodicity, the separated shear layers from the trailing edge of each rib nearly reattach to the trough floor before reaching the next rib. The resultant irrecoverable pressure loss in the form a centerline frictional coefficient is verified by an ‘at-sea’ test on board a US Navy submarine. Based on the duct diameter, their Reynolds numbers are ReDLES=8×103 and (ReDexp)avg=4×106, respectively.  相似文献   

5.
The condensation heat transfer of the ethanol–water mixtures on the vertical tube over a wide range of ethanol concentrations was investigated. The condensation curves of the heat flux and the heat transfer coefficients revealed nonlinear characteristics and had peak values, with respect to the change of the vapor-to-surface temperature difference. This characteristic applies to all ethanol concentrations under all experimental conditions. With the decrease of the ethanol concentrations, the condensation heat transfer coefficient increased notably, especially when the ethanol concentration was very low. The maximum heat transfer coefficient of the vapor mixtures increased to 9 times as compared with that of pure steam at ethanol vapor mass concentration of 1%. With the increase of the ethanol concentrations, the condensation heat transfer coefficient decreased accordingly. When the ethanol concentration reached 50%, the heat transfer coefficient was smaller than that of the pure steam.  相似文献   

6.
Heat transfer with steam condensation under moderate pressure on the surface of a horizontal tube immersed in a bubbling layer was experimentally investigated. A copper test section 16 mm in outer diameter and 400 mm in length was placed in a bubbling column 455 mm in diameter. Experiments were made under pressures of 0.14–0.8 MPa, with void fraction 0.04–0.23, vapor superficial velocities 0.05–0.42 m/s, liquid-wall temperature differences 47–105 K, and heat flux densities 0.12–0.8 MW/m2. The heat transfer process in the bubbling layer is shown to be of a high intensity: with moderate values of steam content, heat transfer coefficients reach 12–14 kW/(m2 · K). Data obtained showed that the known correlations do not consider the influence of pressure on heat transfer. For the first time, data on radial steam content distribution under pressures higher than atmospheric were obtained by an electroprobe method. A table of experimental data is presented.  相似文献   

7.
Experiments were carried out to measure the base pressure distribution of a flow field induced by a potential vortex with its axis normal to a stationary disk. The center base pressure coefficient of the vortex, C0(0), was found to be proportional to Reynolds number from Re = 2.0 × 103 to Re > 2.5 × 104, where Re is based on the disk radius and azimuthal velocity at the disk edge. This behavior of C0(0) is at variance with the experimental results of Phillips (Phys. Fluids, 27, 2215, 1984) and Khoo (M. Eng. Thesis, Natl. Univ. Singapore, 1984), which showed vastly different trends depending on Re. Plausible reasons are suggested for the apparent discrepancies observed. Finally, the extent of the effusing core at the center, r1 (taken to be the radial position where departure from the outer potential flow took place), was found to be proportional to Re−1/2 for all Re values considered.  相似文献   

8.
Two-phase friction and heat transfer characteristics for R-22/R-407C inside a 6.5-mm smooth tube are reported in this study. The heat transfer results for G=100 and 400 kg/m2 s were reported in the present study, and the adiabatic frictional pressure drop was recorded in the range of 100 to 700 kg/m2 s. It is found that the development of flow pattern for R-407C falls behind R-22. This may explain the lower pressure drops for R-407C. The major heat transfer mechanism at low mass flux is nucleate boiling, and virtually becomes the convective evaporation as mass flux increase to G=400 krg/m2 s, Meanwhile, the reduction of heat transfer coefficients for R-407C mixtures are especially profound at low mass flux, and the reduction of heat transfer coefficient decreases with the increase of mass flux.  相似文献   

9.
An original experimental investigation of heat transfer with steam condensation on a surface of a horizontal cooled tube immersed in a bubbling layer was carried out. A copper test section 16 mm in diameter and 285 mm in length was placed in a bubbling column 295 mm in diameter. Experiments were made under a pressure of 0.72-3.8 MPa with volume steam content 0-0.18, steam superficial velocities 0-0.18 m/s, and liquid-wall temperature difference 38–106 K. The heat transfer process in a bubbling layer under high pressures is shown to be of considerably intensity; with moderate values of steam content heat transfer coefficients reach 10–12 kW/(m2·K). The use of the known correlations assumed for the case of air bubbling under atmospheric pressure results in systematically underestimating heat transfer by 30–80%. Data were obtained on heat transfer with film condensation of steam and natural convection of subcooled water at high temperature differences outside the range investigated earlier. Experimental data table is appended.  相似文献   

10.
Electrostatic effects on pressure drop in tube flows   总被引:1,自引:0,他引:1  
Electrohydrodynamic effects on forced convection in tubes may have significant implications for enhancement of heat exchanger performance in heat pumps and other devices. Of particular concern in such applications is the possibility of increased pressure drop associated with electrostatic discharge. Large frictional losses could substantially increase the required pumping power, offsetting performance gains associated with improved heat transfer rates.

This articles describes a series of experiments designed to determine the effects of corona discharge on pressure fields for air flow in cylindrical tubes. Experiments were performed with a single concentric electrode in the tube and with two nonconcentric electrodes. Measurements were performed at potentials from the onset of measurable current to near the spark-over point and at Reynolds numbers from 103 to 2 × 104. Friction factors were seen to increase as much as 250 percent over the values obtained in the absence of an applied electric field. Results suggest that the electrostatic effect on pressure drop is very sensitive to current density, Reynolds number, and electrode configuration.  相似文献   


11.
The results of an experimental study of a temperature field and its statistical characteristics in turbulent water flow upon a sudden change of heat generation in the channel wall are reported. Measurements were performed in 5 mm × 40 mm, 10 mm × 40 mm, and 20 mm × 40 mm channels in the regions of thermal stabilization and stabilized heat transfer at Reynolds numbers of (0.8–6.8) × 104. The measurement results are generalized using a dimensionless time scale. The results of the calculation of heat transfer coefficients at unsteady heat transfer are presented.  相似文献   

12.
Flow condensation heat transfer coefficients (HTCs) and pressure drop of R22, propylene, propane, DME and isobutane are measured on a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 8.8 mm inner diameter and 530 mm length. The refrigerant is cooled by passing cold water through the annulus surrounding the test section. Tests are performed at a fixed refrigerant saturation temperature of 40 ± 0.2 °C with mass fluxes of 100, 200, and 300 kg/m2 s and heat flux of 7.3–7.7 kW/m2. The heat transfer and pressure drop data are obtained in the vapor quality range of 10–90%. Test results show that for a given mass flux the flow condensation HTCs of propylene, propane, DME and isobutane are higher than those of R22 by up to 46.8%, 53.3%, 93.5% and 61.6%, respectively. Also well-known correlations developed based upon conventional fluorocarbon refrigerants predict the present data within a mean deviation of 33%. Finally, the pressure drop increases as the mass flux and quality increase and isobutane shows the highest pressure drop due to its lowest vapor pressure among the fluids tested.  相似文献   

13.
The condensation heat transfer of pure refrigerants, R-22, R-134a and a binary refrigerant R-410A flowing in small diameter tubes was investigated experimentally. The condenser is a countflow heat exchanger which refrigerant flows in the inner tube and cooling water flows in the annulus. The heat exchanger is smooth, horizontal copper tube of 1.77, 3.36 and 5.35 mm inner diameter, respectively. The length of heat exchanger is 1220, 2660 and 3620 mm, respectively. The experiments were conducted at mass flux of 200–400 kg/m2 s and saturation temperature of 40°C. The main results were summarized as follows: in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski and Wu and Little correlation. The new single-phase correlation based on the experimental data was proposed in this study. In case of two-phase flow, the condensation heat transfer coefficient of R-410A for three tubes was slightly higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. The condensation heat transfer coefficient for R-22, R-134a and R-410A increased with increasing mass flux and decreasing tube diameter. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensation heat transfer. Therefore, the new condensation heat transfer correlation based on the experimental data was proposed in the present study.  相似文献   

14.
Our purpose is to design a high heat flux micro-evaporator that can remove more than 100 W/cm2. For this purpose a thin liquid film is evaporized. The liquid film is stabilized in micro-channels by capillary forces. The micro-channels are fabricated by chemical etching on silicon to reduce thermal resistance. For the experiments, the channel plate is heated by an ITO thin film heater deposited on the opposite side of the channel plate. Influence of heat flux, coolant flow rate, and inlet temperature on the temperature of the heater element are investigated. Water is used as working fluid. A maximal heat flux of 125 W/cm2 could be achieved for water inlet temperature of 90 °C and flow rate of 1.0 mL/min. The temperature of the heater element is kept constant at about 120 °C with fluctuations within 8 °C. The measured pressure drop is less than 1000 Pa.  相似文献   

15.
The purpose of this study is to analyse the combined heat and mass transfer of liquid film condensation from a small steam–air mixtures flowing downward along a vertical tube. Both liquid and gas stream are approached by two coupled laminar boundary layer. An implicit finite difference method is employed to solve the coupled governing equations for liquid film and gas flow together with the interfacial matching conditions. The effects of a wide range of changes of three independent variables (inlet pressure, inlet Reynolds number and wall temperature) on the concentration at exit tube, local Nusselt and Sherwood numbers, film thickness, accumulated condensate rate and temperature are carefully examined. The numerical results indicate that in the case of condensing a small concentration of vapours from a mixture, the resistance to heat and mass transfer by non-condensable gas becomes very intense. The comparisons of average Nusselt number and local condensate heat transfer coefficient with the literature results are in good agreement.  相似文献   

16.
This paper reports on an experimental study of saturated flow boiling of R134a inside a circular vertical quartz tube coated with a transparent heater. The inner diameter of the tube was 1.33 mm and the heated length 235.5 mm. The flow pattern at high vapor qualities and the dryout of the liquid film were studied using a high speed CCD camera at the mass fluxes 47.4 and 124.4 kg/m2 s in up flow at 6.425 bar. The heat fluxes ranged from 5 to 13.6 kW/m2 for the lower mass flux and from 20 to 32.4 kW/m2 for the higher mass flux.

The behavior of the flow close to dryout was found to be different at low and high mass flux. At low mass flux the location of the liquid front fluctuated with waves passing high up in the tube. In between the waves, a thin film was formed, slowly evaporating without breaking up.

At high mass flux the location of the liquid front was more stable. In this case the liquid film was seen to break up into liquid streams and dry zones on the tube wall.  相似文献   


17.
In this paper, the heat/mass transfer analogy was used to investigate the heat transfer and pressure drop in a square channel with triangular ribs on its two opposite walls. Reynolds number varied from 1 × 104 to 7 × 104; the dimensionless heights of the triangular ribs H/W were 0.04, 0.07, and 0.1; and their dimensionless pitches S/W were 0.45, 0.63, 1.0, 1.37, 1.55, and 2.1. Experimental results showed that the heat transfer coefficients of the wall with triangular rib were about 1 to 2.3 times larger than those of a smooth-channel wall, and the pressure drops along this roughened channel were about 1 to 10 times larger than those for a smooth channel. Correlations of heat transfer and pressure drop were obtained, which are useful for practical designs.  相似文献   

18.
The over-tip casing of the high-pressure turbine in a modern gas turbine engine is subjected to strong convective heat transfer that can lead to thermally induced failure (burnout) of this component. However, the complicated flow physics in this region is dominated by the close proximity of the moving turbine blades, which gives rise to significant temporal variations at the blade-passing frequency. The understanding of the physical processes that control the casing metal temperature is still limited and this fact has significant implications for the turbine design strategy. A series of experiments has been performed that seeks to address some of these important issues. This article reports the measurements of time-mean heat transfer and time-mean static pressure that have been made on the over-tip casing of a transonic axial-flow turbine operating at flow conditions that are representative of those found in modern gas turbine engines. Time-resolved measurements of these flow variables (that reveal the details of the blade-tip/casing interaction physics) are presented in a companion paper. The nozzle guide vane exit flow conditions in these experiments were a Mach number of 0.93 and a Reynolds number of 2.7 × 106 based on nozzle guide vane mid-height axial chord. The axial and circumferential distributions of heat transfer rate, adiabatic wall temperature, Nusselt number and static pressure are presented. The data reveal large axial variations in the wall heat flux and adiabatic wall temperature that are shown to be primarily associated with the reduction in flow stagnation temperature through the blade row. The heat flux falls by a factor of 6 (from 120 to 20 kW/m2). In contrast, the Nusselt number falls by just 36% between the rotor inlet plane and 80% rotor axial chord; additionally, this drop is near to linear from 20% to 80% rotor axial chord. The circumferential variations in heat transfer rate are small, implying that the nozzle guide vanes do not produce a strong variation in casing boundary layer properties in the region measured. The casing static pressure measurements follow trends that can be expected from the blade loading distribution, with maximum values immediately upstream of the rotor inlet plane, and then a decreasing trend with axial position as the flow is turned and accelerated in the relative frame of reference. The time-mean static pressure measurements on the casing wall also reveal distinct circumferential variations that are small in comparison to the large pressure gradient in the axial direction.  相似文献   

19.
Experimental measurements of heat transfer are made from the inner peripheral surface of a rotating test rig designed to be similar to a gas turbine high pressure compressor internal air system. The test rig comprises a number of annular discs sealed at their periphery by a shroud. An axial throughflow of cooling air enters the test rig and flows through the annular section between the disc bores and a central shaft. Tests were carried out for the following range of rotational speeds and axial throughflow rates: 540 < NR < 10,800 rev/min and (corresponding to the range of rotational and axial Reynolds numbers 4 × 105 < Re < 7.7 × 106 and 3.3 × 104 < Rez < 2.2 × 105).

The shroud Nusselt numbers are found to depend on the shroud Grashof number. They are relatively insensitive to changes in axial Reynolds number and two geometrically similar cavities give similar values of Nusselt number. The heat transfer from the shroud is governed by the mechanism of free convection. It is recommended that a modified form of a correlation for Rayleigh–Bénard convection in a gravitational force field be used, with appropriate modification, to predict shroud heat transfer.  相似文献   


20.
Direct contact heat transfer between water and a heat transfer oil was investigated under non-boiling conditions in co-current turbulent flow through a horizontal concentric annulus. The ratio of the inner pipe diameter to the outer pipe diameter (aspect ratio) κ = 0.730−0.816; total liquid velocity (mixture velocity) VT = 0.42−1.1 m/s; inlet oil temperature Toi = 38−94°C; oil volume fraction in the flowing mixture φo = 0.25−0.75 were varied and their effects on the overall volumetric heat transfer coefficient Uv were determined at constant interfacial tension of 48 dynes/cm.

It was found that, in each concentric pipe set, the overall volumetric heat transfer coefficient increased with increasing dispersed phase volume fraction at each constant mixture velocity and reached a maximum at around φo = φw ≈ 0.5. The maximum Uv values increased with increasing total liquid velocity and decreasing aspect ratio of the annulus. The volumetric heat transfer coefficient was also found to increase with increasing inlet oil temperature and increasing total liquid velocity but to decrease with length along the test section keeping all other parameters constant. Empirical expressions for the volumetric heat transfer coefficient were obtained within the ranges of the experimental parameters.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号