首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sun B  Macka M  Haddad PR 《Electrophoresis》2003,24(12-13):2045-2053
Stacking techniques used independently and also with a high-sensitivity cell (HSC) were employed to optimise sensitivity and detection limits in the direct photometric detection of the following eight arsenic species by capillary zone electrophoresis (CZE): arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), 4-hydroxy-3-nitrophenylarsonic acid (Roxarsone), p-aminophenylarsonic acid (p-ASA), 4-nitrophenylarsonic acid (4-NPAA), and phenylarsonic acid (PAA) (target analytes). The stacking mechanisms, optimised stacking and separation conditions, and concentration sensitivity enhancement factors were discussed and compared for (i) normal stacking mode (NSM, sometimes also referred to as field-amplified stacking) in an uncoated fused-silica capillary in the counter-electroosmotic flow (EOF) mode, (ii) large-volume sample stacking (LVSS) with polarity switching, and (iii) the less often applied stacking method of co-EOF NSM stacking with EOF reversal using a poly(diallydimethylammonium chloride) (PDDAC)-coated capillary. The optimal injection volumes were 7.4, 60 and 17.2% of the total capillary volume, for the above three methods, respectively. LVSS with polarity switching gave the lowest limit of detection (LOD). The use of the HSC further reduced the LOD of each target analytes by a factor of 5-8 times. By combining LVSS and HSC, LODs of the target analytes could be reduced by a factor of 218-311, to 5.61, 9.15, 11.1, and 17.1 microg/L for As(III), DMA, MMA, and As(V), respectively. The method was demonstrated to be applicable to the determination of the target analytes in tap water and lake water, with recoveries in the range of 89.4-103.3%.  相似文献   

2.
Tu C  Zhu L  Ang CH  Lee HK 《Electrophoresis》2003,24(12-13):2188-2192
Large-volume sample stacking (LVSS) is an effective on-capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low-conductivity matrix. NaOH solution is commonly used to back-extract acidic compounds from organic solvent in sample pretreatment. The effect of NaOH as sample matrix on LVSS of haloacetic acids was investigated in this study. It was found that the presence of NaOH in sample did not compromise, but rather help the sample stacking performance if a low pH background electrolyte (BGE) was used. The sensitivity enhancement factor was higher than the case when sample was dissolved in pure water or diluted BGE. Compared with conventional injection (0.4% capillary volume), 97-120-fold sensitivity enhancement in terms of peak height was obtained without deterioration of separation with an injection amount equal to 20% of the capillary volume. This method was applied to determine haloacetic acids in tap water by combination with liquid-liquid extraction and back-extraction into NaOH solution. Limits of detection at sub-ppb levels were obtained for real samples with direct UV detection.  相似文献   

3.
The reaction between α,α-dialkylated amino acids and amino acid N-carboxyanhydrides is slow leading to low concentrations of products (peptides). The detection by capillary electrophoresis of the analytes contained in such samples is therefore a challenging issue. In this work, on-line sample pre-concentration methods based on field-amplified sample stacking have been implemented and compared. Because of the high ionic strength present in the sample matrix, samples were diluted with an organic solvent prior to analysis to decrease the sample conductivity. Different modes of sample injection (field amplified sample injection (FASI), hydrodynamic normal sample stacking (NSS) or large volume sample stacking (LVSS)) were compared. Pre-concentration factors of 20 for FASI, about 30–40 for NSS and 60 for LVSS were obtained for the analysis of (l,l) dipeptide of valine in a large excess of isovaline and 0.2 M of ionic strength. For LVSS application and resolution optimisation, a new non-covalent coating based on the partial modification of the capillary surface was used to tune the electroosmotic flow magnitude and to pump the sample matrix out of the capillary. This on-line sample pre-concentration step allowed confirming that oligopeptides including α,α-dialkylated amino acids are formed during the reaction between α,α-dialkylated amino acids and N-carboxyanhydride amino acids.  相似文献   

4.
On-line sample concentration of fast moving inorganic anions by large volume sample stacking (LVSS) and field enhanced sample injection (FESI) with a water plug under acidic conditions is presented. Detection sensitivity enhancements were around 100 and 1000-fold for LVSS and FESI, respectively. However, reproducibility and linearity of response in the LVSS approach is superior compared to the FESI approach.  相似文献   

5.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

6.
A capillary electrophoresis method is proposed to analyze the four most well-known growth hormone–releasing hormone (GHRH) analogs that are misused by athletes. Dimethyl-β-cyclodextrin used as a chiral selector allowed, for the first time, the separation of those basic peptide analogs, including enantiopeptides (sermorelin and CJC-1293) that differ by the chirality of only one amino acid. To increase the method sensitivity, electrokinetic preconcentration methods have been investigated. The large volume sample stacking with polarity switching (PS-LVSS) method with an injected sample volume corresponding to 80% of the capillary one was found superior to the sweeping in terms of signal enhancement factor (SEF). Acid and organic solvent addition to the sample (0.1 mM phosphoric acid with 30% methanol) led to a twofold signal improvement, when compared to water as a matrix. We increased capillary dimensions to provide a signal enhancement through the injection of a larger sample volume. Finally, using a combination of the optimized PS-LVSS preconcentration with the chiral capillary zone electrophoresis (CZE), the GHRH analogs were separated and limits of detection between 75 and 200 ng/mL were reached. This method was successfully applied to urine after a desalting step. An optimized C18 SPE was used for that purpose in order to provide low sample conductivity (<130 µS/cm) and preserve the efficiency of LVSS preconcentration. SEF of 640 was obtained with desalted urine spiked with sermorelin by comparison to the CZE (without preconcentration) method.  相似文献   

7.
Electrokinetic supercharging (EKS) combines field-amplified sample injection with transient isotachophoresis (tITP) to create a powerful on-line preconcentration technique for capillary electrophoresis. In this work, EKS is enhanced with a positive pressure (pressure-assisted EKS, or PA-EKS) during injection to improve stacking of non-steroidal anti-inflammatory drugs (NSAIDs). Several parameters, including buffer composition and concentration, terminating electrolyte, organic modifier, and injection voltage and injection time of both terminating electrolyte and sample were optimized. Detection limits for seven NSAIDs were determined and an enhancement in sensitivity of almost 50,000-fold was obtained. The PA-EKS method has the potential to be a simple MS compatible preconcentration method to improve the sensitivity of CE.  相似文献   

8.
DetectionofCatecholicCompoundswithField-ampilfiedCZE-AmperometryHUShen,PANGDai-wen,HUYong-gang,CHENGJie-ke(DepartmentofChemis...  相似文献   

9.
Liu S  Li Q  Chen X  Hu Z 《Electrophoresis》2002,23(19):3392-3397
A simple and rapid capillary zone electrophoresis method was developed for the separation of the main alkaloids from Sophora flavescens Ait. with the optimum buffer solution containing 110 mM NaH(2)PO(4) and 15% 2-propanol (pH 3.0). The field-amplified sample stacking (FASS) technique was applied to the on-line concentration of the alkaloids. The data presented in this work demonstrate that the use of a short water plug at the column inlet is essential for improving the reproducibility of FASS with electro-injection, and that the water plug injection time affected the sensitivity significantly. The sample concentration was further increased by about 2-3-fold by the introduction of a relatively longer water plug. With this stacking measure, the concentration sensitivity was about 3-4 orders of magnitude higher than in hydrodynamic injection.  相似文献   

10.
A new sample introduction method of capillary electrophoresis, in which field-amplified sample injection was combined with a pre-concentration of non-uniform field electrophoresis, is presented in this paper. With an additional pre-concentration voltage applied to sample solution, a non-uniform electric field was generated, with which analytical cations or anions were pre-concentrated around an electrode adjacent to the injection end of capillary. After the pre-concentration, analytical ions were injected into the capillary and stacked at the boundary between sample and buffer solution inside capillary by field-amplified injection technique. In contrast to the conventional field-amplified injection, larger concentration factor and higher analytical sensitivity were obtained with the improved pre-concentration method. Its concentration factor was about 10 approximately 15 fold as that of field-amplified sample injection.  相似文献   

11.
Kuo CY  Chiou SS  Wu SM 《Electrophoresis》2006,27(14):2905-2909
This paper describes approaches for large-volume sample stacking (LVSS) with an EOF pumpin CE for the determination of methotrexate (MTX) and its metabolites in human plasma. After pretreatment of plasma through a SPE cartridge, a large sample volume was loaded by hydrodynamic injection (3 psi, 70 s) into the capillary filled with phosphate buffer (70 mM, pH 6.0) containing 0.01% polyethylene oxide. Following removal of a large plug of sample matrix from the capillary using polarity switching (-25 kV), the separation of anionic analytes was subsequently performed without changing polarity again, achieving an improvement of sensitivity of around a 100-fold. The method was applied to therapeutic drug monitoring of MTX in one acute lymphoblastic leukemia patient. This study is one of very few applications showing the feasibility of LVSS in analysis of biological samples by CE.  相似文献   

12.
Xu Y  Wang W  Li SF 《Electrophoresis》2007,28(10):1530-1539
This report describes a method to simultaneously determine 11 low-molecular-weight (LMW) organic acids and 16 chlorinated acid herbicides within a single run by a portable CE system with contactless conductivity detection (CCD) in a poly(vinyl alcohol) (PVA)-coated capillary. Under the optimized condition, the LODs of CE-CCD ranged from 0.056 to 0.270 ppm, which were better than for indirect UV (IUV) detection of the 11 LMW organic acids or UV detection of the 16 chlorinated acid herbicides. Combined with an on-line field-amplified sample stacking (FASS) procedure, sensitivity enhancement of 632- to 1078-fold was achieved, with satisfactory reproducibility (RSDs of migration times less than 2.2%, and RSDs of peak areas less than 5.1%). The FASS-CE-CCD method was successfully applied to determine the two groups of acidic pollutants in two kinds of environmental water samples. The portable CE-CCD system shows advantages such as simplicity, cost effectiveness, and miniaturization. Therefore, the method presented in this report has great potential for onsite analysis of various pollutants at the trace level.  相似文献   

13.
This paper describes two different approaches for increasing the sensitivity for the analysis of ceftiofur by capillary electrophoresis (CE). Two different techniques based on the introduction of an enlarged volume of sample, namely large volume sample stacking (LVSS) and in-line solid phase extraction (SPE) were studied and compared. LVSS allowed the on-column electrophoretic preconcentration of ceftiofur without modification of the separation capillary. In-line SPE-CE was developed by using a home-made microcartridge that was filled with a reversed-phase sorbent (C18). The microcartridge was coupled in-line near the inlet of the separation capillary. LVSS and in-line SPE-CE allowed automated operation and improved sensitivity for the analysis of ceftiofur with respect to conventional CE. When environmental water samples were analyzed, an additional pretreatment step based on off-line SPE was necessary in both cases to further decrease the detection limits. In terms of sensitivity for the determination of ceftiofur in river water samples, the combination of off-line SPE with in-line SPE-CE was found the most sensitive with a detection limit of 10 ng L−1, whereas the method based on the use of off-line SPE with LVSS presented a detection limit of 100 ng L−1.  相似文献   

14.
Field-enhanced sample stacking, field-enhanced sample injection as well as electrokinetic supercharging have been successfully integrated in carrier ampholyte-based capillary electrophoresis. Through the analysis of different test sample mixtures, it has been shown that the carrier ampholyte-based background electrolytes, in spite of their very low conductivity, allow efficient online preconcentration of analytes by field-amplified techniques. Sensitivity enhancement factors of the same magnitude as those usually encountered with classical conductive background electrolytes have been obtained in such carrier ampholyte-based buffers. Depending on the online preconcentration method that has been integrated, sensitivity enhancement factors between 50 and several thousands have been reached.  相似文献   

15.
New methods based on nonaqueous capillary electrophoresis (NACE) were developed as promising alternatives for the simultaneous separation and determination of p-hydroxybenzoic acid (PHBA) and a group of parabens (methyl, ethyl, propyl, butyl and benzyl p-hydroxybenzoates), with good resolution and excellent sensitivity. As an effective on-line preconcentration technique, large-volume sample stacking (LVSS) was successfully combined with NACE allowing significant sensitivity enhancement. Identification and quantification of the analytes were performed by diode array detection (DAD). The influence of different parameters, such as buffer apparent pH, concentration of electrolyte, temperature, applied voltage and sample volume, on the efficiency, resolution and sensitivity of the electrophoretic separation was studied. The analytical performance was evaluated, and both NACE-DAD and LVSS-NACE-DAD methods showed good linearity, precision and instrumental LODs at low ng/mL levels. These LODs were compared with those described in the literature, and it was found that NACE-DAD method was comparable to GC-MS, while LVSS-NACE-DAD procedure achieved sensitivity similar to LC-MS, LC-MS/MS and GC-MS/MS, even using conventional ultraviolet-visible absorption detection. To test their suitability, proposed methods were evaluated for the analysis of PHBA and parabens at low and sub-ng/mL levels in environmental water samples.  相似文献   

16.
Pan Q  Hong S  Zhu X  Zhao M  Lee LP 《Lab on a chip》2012,12(5):932-938
We report a novel on-line electrophoretic sample clean-up approach for highly sensitive and reproducible microchip electrophoretic (μCE) immunoassay of low-abundance proteins in human serum. The method takes advantage of the differential effect of field-amplified sample stacking on molecules with different electrophoretic mobility. Large interfering proteins are removed from the loading channel by simple voltage control, resulting in selective concentration and injection of smaller target analytes to the separation channel. As a proof of concept, an antibody-free injection mode was developed for direct μCE immunoassay of human insulin-like growth factor-I (IGF-I) in serum samples without any additional purification steps. Clear and sharp peaks were obtained for IGF-I with low background and excellent reproducibility. Besides, the assay sensitivity was further increased by addition of ethanol to the sample buffer at a concentration of 50% right before performing the μCE detection. The lower limit of detection of IGF-I achieved 0.68 ng mL(-1), with an overall signal enhancement factor of 2750. The established on-line electrophoretic sample clean-up approach may find wide applications in the development of other microchip-based high-throughput analytical platforms for clinical and biological use.  相似文献   

17.
Xu Y  Qin W  Lau YH  Li SF 《Electrophoresis》2005,26(18):3507-3517
This report describes a novel online field-amplified sample stacking (FASS) procedure to analyze 16 chlorinated acid herbicides. By using a poly(vinyl alcohol) (PVA)-coated capillary to reduce electroosmotic flow and introducing a methanol-water plug before sample loading, the sample injection time could be very long without loss of sample and separation efficiency. Under the optimized condition, the FASS procedure could provide great sensitivity enhancement (5000-10 000-fold) and satisfactory reproducibility (relative standard deviations of migration times less than 2.4%, relative standard deviations of peak areas less than 8.0%). Combined with cationic surfactant-assisted solid-phase extraction (CSA-SPE), the limit of detection of the herbicides ranged from 0.269 to 20.3 ppt, which are two orders lower than those of the US Environmental Protection Agency standard method 515.1. The CSA-SPE-FASS-CE method was successfully applied to the analysis of local pond water.  相似文献   

18.
Almeda S  Arce L  Valcárcel M 《Electrophoresis》2008,29(14):3074-3080
A reliable MEKC method for the identification and quantitation of traces of the nonsteroidal anti-inflammatory drugs (NSAIDs) ketoprofen, fenbufen and indomethacin in saliva is proposed. Using CE to analyze biological samples often requires suppressing the interferences and peak broadening typically resulting from high-conductivity sample matrices. We addressed this problem by using Microcon, a centrifugal filter device, to reduce the viscosity of saliva and exclude most higher-molecular-mass substances. This initial pretreatment was followed by the combined used of off-line SPE to isolate and concentrate the analytes, and large-volume stacking with polarity switching (LVSS) in the capillary. These two preconcentration steps allow the determination of NSAIDs at concentrations above 0.1 microg/L; therefore, the proposed SPE/LVSS/MEKC method affords a 500-fold sensitivity enhancement relative to conventional CE injection. The LODs obtained afford the determination of NSAIDs in saliva, where analytes can be present at the microgram-per-liter level.  相似文献   

19.
Liu S  Wang H 《色谱》2011,29(9):816-829
毛细管电泳以其分析速度快、分离效率高、操作简便、能够实现高通量而获得了广泛的应用,但由于检测窗口小而导致其检测灵敏度低。为了提高检测灵敏度,目前已发展了多种毛细管电泳在线聚焦和样品预浓缩技术,如场放大样品堆积、pH调节浓缩、胶束电动毛细管色谱、等速电泳等。这些技术由于能够在毛细管内同时实现样品的聚焦和分离、操作简便而获得了广泛的兴趣和关注。本文针对毛细管电泳的在线聚焦的原理、技术和应用做一简要的介绍和总结。  相似文献   

20.
《Electrophoresis》2018,39(19):2439-2445
An on‐line large volume sample stacking with polarity switching (LVSS) method was proposed for simultaneously determining lignanoids and ginsenosides in MEEKC. The parameters including the pH value and concentration of buffer solution, SDS, organic modifier, oil phase, running voltage, and temperature as well as injection time, sample matrix, stacking voltage, and time influencing separation and stacking were systematically optimized. The method was verified by performing precision, accuracy, stability, and recovery. Its reliability was proved by separating and quantifying two lignanoids and three ginsenosides in Shengmai injectionSMI. The sensitivity of these compounds was improved by MEEKC‐LVSS method for 6–11 times than conventional MEEKC. Thus, this developed on‐line MEEKC‐LVSS method was sensitive, practical, and reliable.  相似文献   